1.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
2.Ectopic Mediastinal Thyroid Successfully Removed by Surgical Excision via Transcervical Approach
Seung Yup SON ; Se Hyeon JIN ; Jong Hwan LEE ; Su Il KIM
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(4):168-171
Ectopic thyroid is thyroid tissue found in places other than the anterolateral aspect of the second to fourth tracheal ring. Mediastinal ectopic thyroid is rare and only few cases have been reported. The authors experienced a case of 41-year-old female patient with an anterior neck mass. The patient had mild chest discomfort when breathing with no other symptoms. Imaging studies suggested tumor of thymic tissue origin and surgical excision was done. The mass was successfully removed and histopathologically determined to be thyroid tissue. We hereby report with a review of literature a case of ectopic thyroid found in the mediastinum, which was successfully removed by transcervical incision.
3.Radiologic evolution of biopsy-proven acute interstitial nephritis: a multimodal imaging case report
Euljo JEONG ; Bong Soo PARK ; Il Hwan KIM ; Jung Hee SON ; Kyung Han NAM ; Yoon Ho LEE ; Yoo Jin LEE
Kosin Medical Journal 2025;40(1):72-79
This report presents radiologic changes after clinical improvement in a patient with acute interstitial nephritis (AIN). A 45-year-old female patient was referred for decreased renal function. Eight months prior, she had undergone hysterectomy and received chemotherapy. At the start of chemotherapy, her baseline creatinine level was 0.55 mg/dL, which rose to 1.46 mg/dL. Multiple imaging modalities performed when decreased renal function was observed revealed bilateral renal enlargement with increased cortical attenuation on computed tomography (CT), cortical hyperechogenicity on ultrasonography, and diffusion restriction in the renal cortices on magnetic resonance imaging. A renal biopsy was performed, and AIN was diagnosed. Follow-up laboratory tests showed that kidney function had improved to normal levels, and CT at that time showed a reduction in the size of both kidneys. Radiologic changes can serve as clues for the diagnosis of AIN. This is the first report to confirm radiological changes after the clinical improvement of AIN, thereby providing novel information about the course of AIN.
4.Ectopic Mediastinal Thyroid Successfully Removed by Surgical Excision via Transcervical Approach
Seung Yup SON ; Se Hyeon JIN ; Jong Hwan LEE ; Su Il KIM
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(4):168-171
Ectopic thyroid is thyroid tissue found in places other than the anterolateral aspect of the second to fourth tracheal ring. Mediastinal ectopic thyroid is rare and only few cases have been reported. The authors experienced a case of 41-year-old female patient with an anterior neck mass. The patient had mild chest discomfort when breathing with no other symptoms. Imaging studies suggested tumor of thymic tissue origin and surgical excision was done. The mass was successfully removed and histopathologically determined to be thyroid tissue. We hereby report with a review of literature a case of ectopic thyroid found in the mediastinum, which was successfully removed by transcervical incision.
5.Radiologic evolution of biopsy-proven acute interstitial nephritis: a multimodal imaging case report
Euljo JEONG ; Bong Soo PARK ; Il Hwan KIM ; Jung Hee SON ; Kyung Han NAM ; Yoon Ho LEE ; Yoo Jin LEE
Kosin Medical Journal 2025;40(1):72-79
This report presents radiologic changes after clinical improvement in a patient with acute interstitial nephritis (AIN). A 45-year-old female patient was referred for decreased renal function. Eight months prior, she had undergone hysterectomy and received chemotherapy. At the start of chemotherapy, her baseline creatinine level was 0.55 mg/dL, which rose to 1.46 mg/dL. Multiple imaging modalities performed when decreased renal function was observed revealed bilateral renal enlargement with increased cortical attenuation on computed tomography (CT), cortical hyperechogenicity on ultrasonography, and diffusion restriction in the renal cortices on magnetic resonance imaging. A renal biopsy was performed, and AIN was diagnosed. Follow-up laboratory tests showed that kidney function had improved to normal levels, and CT at that time showed a reduction in the size of both kidneys. Radiologic changes can serve as clues for the diagnosis of AIN. This is the first report to confirm radiological changes after the clinical improvement of AIN, thereby providing novel information about the course of AIN.
6.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
7.Complete or incomplete revascularization in patients with left main culprit lesion acute myocardial infarction with multivessel disease: a retrospective observational study
Sun Oh KIM ; Hong-Ju KIM ; Jong-Il PARK ; Kang-Un CHOI ; Jong-Ho NAM ; Chan-Hee LEE ; Jang-Won SON ; Jong-Seon PARK ; Sung-Ho HER ; Ki-Yuk CHANG ; Tae-Hoon AHN ; Myung-Ho JEONG ; Seung-Woon RHA ; Hyo-Soo KIM ; Hyeon-Cheol GWON ; In-Whan SEONG ; Kyung-Kuk HWANG ; Seung-Ho HUR ; Kwang-Soo CHA ; Seok-Kyu OH ; Jei-Keon CHAE ; Ung KIM
Journal of Yeungnam Medical Science 2025;42(1):18-
Background:
Complete revascularization has demonstrated better outcomes in patients with acute myocardial infarction (AMI) and multivessel disease. However, in the case of left main (LM) culprit lesion AMI with multivessel disease, there is limited evidence to suggest that complete revascularization is better.
Methods:
We reviewed 16,831 patients in the Korea Acute Myocardial Infarction Registry who were treated from July 2016 to June 2020, and 399 patients were enrolled with LM culprit lesion AMI treated with percutaneous coronary intervention. We categorized the patients as those treated with complete revascularization (n=295) or incomplete revascularization (n=104). The study endpoint was major adverse cardiac and cerebrovascular events (MACCE), a composite of all-cause death, myocardial infarction, ischemia-driven revascularization, stent thrombosis, and stroke. We performed propensity score matching (PSM) and analyzed the incidence of MACCE at 1 year.
Results:
After PSM, the two groups were well balanced. There was no significant difference between the two groups in MACCE at 1 year (12.1% vs. 15.2%; hazard ratio, 1.28; 95% confidence interval, 0.60–2.74; p=0.524) after PSM. The components of MACCE and major bleeding were also not significantly different.
Conclusion
There was no significant difference in clinical outcomes between the groups treated with complete or incomplete revascularization for LM culprit lesion AMI with multivessel disease.
8.Ectopic Mediastinal Thyroid Successfully Removed by Surgical Excision via Transcervical Approach
Seung Yup SON ; Se Hyeon JIN ; Jong Hwan LEE ; Su Il KIM
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(4):168-171
Ectopic thyroid is thyroid tissue found in places other than the anterolateral aspect of the second to fourth tracheal ring. Mediastinal ectopic thyroid is rare and only few cases have been reported. The authors experienced a case of 41-year-old female patient with an anterior neck mass. The patient had mild chest discomfort when breathing with no other symptoms. Imaging studies suggested tumor of thymic tissue origin and surgical excision was done. The mass was successfully removed and histopathologically determined to be thyroid tissue. We hereby report with a review of literature a case of ectopic thyroid found in the mediastinum, which was successfully removed by transcervical incision.
9.Radiologic evolution of biopsy-proven acute interstitial nephritis: a multimodal imaging case report
Euljo JEONG ; Bong Soo PARK ; Il Hwan KIM ; Jung Hee SON ; Kyung Han NAM ; Yoon Ho LEE ; Yoo Jin LEE
Kosin Medical Journal 2025;40(1):72-79
This report presents radiologic changes after clinical improvement in a patient with acute interstitial nephritis (AIN). A 45-year-old female patient was referred for decreased renal function. Eight months prior, she had undergone hysterectomy and received chemotherapy. At the start of chemotherapy, her baseline creatinine level was 0.55 mg/dL, which rose to 1.46 mg/dL. Multiple imaging modalities performed when decreased renal function was observed revealed bilateral renal enlargement with increased cortical attenuation on computed tomography (CT), cortical hyperechogenicity on ultrasonography, and diffusion restriction in the renal cortices on magnetic resonance imaging. A renal biopsy was performed, and AIN was diagnosed. Follow-up laboratory tests showed that kidney function had improved to normal levels, and CT at that time showed a reduction in the size of both kidneys. Radiologic changes can serve as clues for the diagnosis of AIN. This is the first report to confirm radiological changes after the clinical improvement of AIN, thereby providing novel information about the course of AIN.
10.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.

Result Analysis
Print
Save
E-mail