1.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
2.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
3.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.The change in high-sensitivity troponin-T as a risk factor for significant coronary stenosis in patients with acute coronary syndrome
Min Chul KIM ; Seok OH ; Youngkeun AHN ; Keumyi MOON ; Joon Ho AHN ; Dae Young HYUN ; Kyung Hoon CHO ; Doo Sun SIM ; Young Joon HONG ; Ju Han KIM ; Myung Ho JEONG ; Jeong Gwan CHO ; Jong Chun PARK
The Korean Journal of Internal Medicine 2021;36(3):608-616
Background/Aims:
High-sensitivity cardiac troponin (hs-TnT) assays detect very low levels of cardiac troponin. This study examined the interval change between initial and subsequent hs-TnT levels and evaluated its ability to predict significant coronary stenosis.
Methods:
The study analyzed 163 patients who presented with acute coronary syndrome (ACS) and underwent coronary angiography (CAG) between April 2014 and May 2018. The 0 and 3-hour hs-TnT were checked. The patients were subdivided into positive (n = 32) and negative (n = 131) interval change groups. The presence of significant coronary artery stenosis on CAG in the two groups was compared.
Results:
The positive interval change group was older and had higher 0 and 3-hour hs-TnT and blood glucose levels than the negative interval change group. Significant coronary stenosis was more common in the positive interval change group than in the negative interval change group (68.8% vs. 23.7%, p = 0.001). However, vasospasm was more common in the negative interval change group (6.3% vs. 31.3%, p = 0.003). The positive interval change group had higher rates of bifurcation lesions and received more percutaneous coronary intervention. In multivariate analysis, age, interval change of serial hs-TnT and diabetes mellitus were independent predictors of significant coronary artery stenosis.
Conclusions
This study identified a relationship between the serial change in cardiac biomarkers and the presence of significant coronary stenosis in patients with ACS. Serial hs-TnT change was associated with real angiographic stenosis in patients with ACS.
6.The change in high-sensitivity troponin-T as a risk factor for significant coronary stenosis in patients with acute coronary syndrome
Min Chul KIM ; Seok OH ; Youngkeun AHN ; Keumyi MOON ; Joon Ho AHN ; Dae Young HYUN ; Kyung Hoon CHO ; Doo Sun SIM ; Young Joon HONG ; Ju Han KIM ; Myung Ho JEONG ; Jeong Gwan CHO ; Jong Chun PARK
The Korean Journal of Internal Medicine 2021;36(3):608-616
Background/Aims:
High-sensitivity cardiac troponin (hs-TnT) assays detect very low levels of cardiac troponin. This study examined the interval change between initial and subsequent hs-TnT levels and evaluated its ability to predict significant coronary stenosis.
Methods:
The study analyzed 163 patients who presented with acute coronary syndrome (ACS) and underwent coronary angiography (CAG) between April 2014 and May 2018. The 0 and 3-hour hs-TnT were checked. The patients were subdivided into positive (n = 32) and negative (n = 131) interval change groups. The presence of significant coronary artery stenosis on CAG in the two groups was compared.
Results:
The positive interval change group was older and had higher 0 and 3-hour hs-TnT and blood glucose levels than the negative interval change group. Significant coronary stenosis was more common in the positive interval change group than in the negative interval change group (68.8% vs. 23.7%, p = 0.001). However, vasospasm was more common in the negative interval change group (6.3% vs. 31.3%, p = 0.003). The positive interval change group had higher rates of bifurcation lesions and received more percutaneous coronary intervention. In multivariate analysis, age, interval change of serial hs-TnT and diabetes mellitus were independent predictors of significant coronary artery stenosis.
Conclusions
This study identified a relationship between the serial change in cardiac biomarkers and the presence of significant coronary stenosis in patients with ACS. Serial hs-TnT change was associated with real angiographic stenosis in patients with ACS.
7.Impact of Anticoagulation Intensity in Korean Patients with Atrial Fibrillation: Is It Different from Western Population?
Ki Hong LEE ; Jeong Gwan CHO ; Nuri LEE ; Kyung Hoon CHO ; Hyung Ki JEONG ; Hyukjin PARK ; Yongcheol KIM ; Jae Yeong CHO ; Min Chul KIM ; Doo Sun SIM ; Hyun Ju YOON ; Namsik YOON ; Kye Hun KIM ; Young Joon HONG ; Hyung Wook PARK ; Youngkeun AHN ; Myung Ho JEONG ; Jong Chun PARK
Korean Circulation Journal 2020;50(2):163-175
BACKGROUND AND OBJECTIVES: Although anticoagulation with warfarin is recommended as an international normalized ratio (INR) of prothrombin time between 2.0 and 3.0 and mean time in the therapeutic range (TTR) ≥70%, little has been proven that universal criteria might be suitable in Korean atrial fibrillation (AF) patients.METHODS: We analyzed 710 patients with non-valvular AF who took warfarin. INR value and clinical outcomes were assessed during 2-year follow-up. Intensity of anticoagulation was assessed as mean INR value and TTR according to target INR range. Primary net-clinical outcome was defined as the composite of new-onset stroke and major bleeding. Secondary net-clinical outcome was defined as the composite of new-onset stroke, major bleeding and death.RESULTS: Thromboembolism was significantly decreased when mean INR was over 1.6. Major bleeding was significantly decreased when TTR was over 70% and mean INR was less than 2.6. Mean INR 1.6–2.6 significantly reduced thromboembolism (adjusted hazard ratio [HR], 0.40; 95% confidence interval [CI], 0.19–0.85), major bleeding (HR, 0.43; 95% CI, 0.23–0.81), primary (HR, 0.50; 95% CI, 0.29–0.84) and secondary (HR, 0.45; 95% CI, 0.28–0.74) net-clinical outcomes, whereas mean INR 2.0–3.0 did not. Simultaneous satisfaction of mean INR 1.6–2.6 and TTR ≥70% was associated with significant risk reduction of major bleeding, primary and secondary net-clinical outcomes.CONCLUSIONS: Mean INR 1.6–2.6 was better than mean INR 2.0–3.0 for the prevention of thromboembolism and major bleeding. However, INR 1.6–2.6 and TTR ≥70% had similar clinical outcomes to INR 2.0–3.0 and TTR ≥70% in Korean patients with non-valvular AF.
Atrial Fibrillation
;
Follow-Up Studies
;
Hemorrhage
;
Humans
;
International Normalized Ratio
;
Prothrombin Time
;
Risk Reduction Behavior
;
Stroke
;
Thromboembolism
;
Warfarin
8.Impact of Anticoagulation Intensity in Korean Patients with Atrial Fibrillation: Is It Different from Western Population?
Ki Hong LEE ; Jeong Gwan CHO ; Nuri LEE ; Kyung Hoon CHO ; Hyung Ki JEONG ; Hyukjin PARK ; Yongcheol KIM ; Jae Yeong CHO ; Min Chul KIM ; Doo Sun SIM ; Hyun Ju YOON ; Namsik YOON ; Kye Hun KIM ; Young Joon HONG ; Hyung Wook PARK ; Youngkeun AHN ; Myung Ho JEONG ; Jong Chun PARK
Korean Circulation Journal 2020;50(2):163-175
BACKGROUND AND OBJECTIVES:
Although anticoagulation with warfarin is recommended as an international normalized ratio (INR) of prothrombin time between 2.0 and 3.0 and mean time in the therapeutic range (TTR) ≥70%, little has been proven that universal criteria might be suitable in Korean atrial fibrillation (AF) patients.
METHODS:
We analyzed 710 patients with non-valvular AF who took warfarin. INR value and clinical outcomes were assessed during 2-year follow-up. Intensity of anticoagulation was assessed as mean INR value and TTR according to target INR range. Primary net-clinical outcome was defined as the composite of new-onset stroke and major bleeding. Secondary net-clinical outcome was defined as the composite of new-onset stroke, major bleeding and death.
RESULTS:
Thromboembolism was significantly decreased when mean INR was over 1.6. Major bleeding was significantly decreased when TTR was over 70% and mean INR was less than 2.6. Mean INR 1.6–2.6 significantly reduced thromboembolism (adjusted hazard ratio [HR], 0.40; 95% confidence interval [CI], 0.19–0.85), major bleeding (HR, 0.43; 95% CI, 0.23–0.81), primary (HR, 0.50; 95% CI, 0.29–0.84) and secondary (HR, 0.45; 95% CI, 0.28–0.74) net-clinical outcomes, whereas mean INR 2.0–3.0 did not. Simultaneous satisfaction of mean INR 1.6–2.6 and TTR ≥70% was associated with significant risk reduction of major bleeding, primary and secondary net-clinical outcomes.
CONCLUSIONS
Mean INR 1.6–2.6 was better than mean INR 2.0–3.0 for the prevention of thromboembolism and major bleeding. However, INR 1.6–2.6 and TTR ≥70% had similar clinical outcomes to INR 2.0–3.0 and TTR ≥70% in Korean patients with non-valvular AF.
9.Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets
Kyung Chun KIM ; Doo Hyun KIM ; Sung Chul KIM ; Jae Ho KIM
Safety and Health at Work 2020;11(4):405-417
Background:
Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years.
Methods:
Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets’ conductor surface and content, insulator weight, and thermal deformation temperature.
Results:
Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 °C. In relation to the installation year (30 years), insulation resistance decreased from 70 °C, which is as much as 40 °C lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased.
Conclusion
The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 °C of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 °C. It is necessary to manage electrical socket outlets that have been installed for a long time.
10.Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets
Kyung Chun KIM ; Doo Hyun KIM ; Sung Chul KIM ; Jae Ho KIM
Safety and Health at Work 2020;11(4):405-417
Background:
Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years.
Methods:
Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets’ conductor surface and content, insulator weight, and thermal deformation temperature.
Results:
Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 °C. In relation to the installation year (30 years), insulation resistance decreased from 70 °C, which is as much as 40 °C lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased.
Conclusion
The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 °C of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 °C. It is necessary to manage electrical socket outlets that have been installed for a long time.

Result Analysis
Print
Save
E-mail