1.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
2.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
3.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
4.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
5.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
6.Analysis of Response and Progression Patterns of Tyrosine Kinase Inhibitors in Recurrent or Metastatic Adenoid Cystic Carcinoma: A Post Hoc Analysis of Two KCSG Phase II Trials
Youjin KIM ; Bhumsuk KEAM ; Eun Joo KANG ; Jin-Soo KIM ; Hye Ryun KIM ; Keun-Wook LEE ; Jung Hye KWON ; Kyoung Eun LEE ; Yaewon YANG ; Yoon Hee CHOI ; Min Kyoung KIM ; Jun Ho JI ; Tak YUN ; Moon Young CHOI ; Ki Hyeong LEE ; Sung-Bae KIM ; Myung-Ju AHN
Cancer Research and Treatment 2024;56(4):1068-1076
Purpose:
In this study, we evaluated 66 patients diagnosed with adenoid cystic carcinoma (ACC) enrolled in two Korean Cancer Study Group trials to investigate the response and progression patterns in recurrent and/or metastatic ACC treated with vascular endothelial growth factor receptor tyrosine kinase inhibitors (VEGFR-TKIs).
Materials and Methods:
We evaluated 66 patients diagnosed with ACC who were enrolled in the Korean Cancer Study Group trials. The tumor measurements, clinical data, treatment outcomes, and progression patterns of therapy were analyzed.
Results:
In the 66 patients (53 receiving axitinib and 13 receiving nintedanib), the disease control rate was 61%, and three patients achieved partial response. The median follow-up, median progression-free survival (PFS), overall survival, and 6-month PFS rate were 27.6%, 12.4%, and 18.1% months and 62.1%, respectively. Among 42 patients who experienced progression, 27 (64.3%) showed target lesion progression. Bone metastasis was an independent poor prognostic factor.
Conclusion
Overall, most patients demonstrated stable disease with prolonged PFS; however, prominent target lesion progression occurred in some patients. Thus, PFS may capture VEGFR-TKI efficacy better than the objective response rate.
7.Clinical Characteristics and Treatment Outcomes of Childhood Acute Promyelocytic Leukemia in Korea: A Nationwide Multicenter Retrospective Study by Korean Pediatric Oncology Study Group
Kyung Mi PARK ; Keon Hee YOO ; Seong Koo KIM ; Jae Wook LEE ; Nack-Gyun CHUNG ; Hee Young JU ; Hong Hoe KOO ; Chuhl Joo LYU ; Seung Min HAN ; Jung Woo HAN ; Jung Yoon CHOI ; Kyung Taek HONG ; Hyoung Jin KANG ; Hee Young SHIN ; Ho Joon IM ; Kyung-Nam KOH ; Hyery KIM ; Hoon KOOK ; Hee Jo BAEK ; Bo Ram KIM ; Eu Jeen YANG ; Jae Young LIM ; Eun Sil PARK ; Eun Jin CHOI ; Sang Kyu PARK ; Jae Min LEE ; Ye Jee SHIM ; Ji Yoon KIM ; Ji Kyoung PARK ; Seom Gim KONG ; Young Bae CHOI ; Bin CHO ; Young Tak LIM
Cancer Research and Treatment 2022;54(1):269-276
Purpose:
Acute promyelocytic leukemia (APL) is a rare disease in children and there are some different characteristics between children and adult. We aimed to evaluate incidence, clinical characteristics and treatment outcomes of pediatric APL in Korea.
Materials and Methods:
Seventy-nine pediatric APL patients diagnosed from January 2009 to December 2016 in 16 tertiary medical centers in Korea were reviewed retrospectively.
Results:
Of 801 acute myeloid leukemia children, 79 (9.9%) were diagnosed with APL. The median age at diagnosis was 10.6 years (range, 1.3 to 18.0). Male and female ratio was 1:0.93. Thirty patients (38.0%) had white blood cell (WBC) count greater than 10×109/L at diagnosis. All patients received induction therapy consisting of all-trans retinoic acid and chemotherapy. Five patients (6.6%) died during induction chemotherapy and 66 patients (86.8%) achieved complete remission (CR) after induction chemotherapy. The causes of death were three intracranial hemorrhage, one cerebral infarction, and one sepsis. Five patients (7.1%) suffered a relapse during or after maintenance chemotherapy. The estimated 4-year event-free survival and overall survival (OS) rates were 82.1%±4.4%, 89.7%±5.1%, respectively. The 4-year OS was significantly higher in patients with initial WBC < 10×109/L than in those with initial WBC ≥ 10×109/L (p=0.020).
Conclusion
This study showed that the CR rates and survival outcomes in Korean pediatric APL patients were relatively good. The initial WBC count was the most important prognostic factor and most causes of death were related to serious bleeding in the early stage of treatment.
8.Mixed- versus predilution hemodiafiltration effects on convection volume and small and middle moleculeclearance in hemodialysis patients: a prospective randomized controlled trial
Kyoung Sook PARK ; Ea Wha KANG ; Tae Ik CHANG ; Wonji JO ; Jung Tak PARK ; Tae-Hyun YOO ; Shin-Wook KANG ; Seung Hyeok HAN
Kidney Research and Clinical Practice 2021;40(3):445-456
Background:
The use of newly developed mixed-dilution hemodiafiltration (HDF) can supplement the weaknesses of pre- and postdilution HDF. However, it is unclear whether mixed-HDF performs well compared to predilution HDF.
Methods:
We conducted a prospective, open-labeled, randomized controlled trial from two hemodialysis centers in Korea. Between January 2017 and September 2019, 60 patients who underwent chronic hemodialysis were randomly assigned at a 1:1 ratio to receive either predilution HDF (n = 30) or mixed-HDF (n = 30) for 6 months. We compared convection volume, changes in small- and medium-sized molecule clearance, high-sensitive C-reactive protein (hs-CRP) level, and dialysis-related parameters between the two dialysis modalities.
Results:
A mean effective convection volume of 41.0 ± 10.3 L/session in the predilution HDF group and 51.5 ± 9.0 L/session in the mixed-HDF group was obtained by averaging values of three time-points. The difference in effective convection volume between the groups was 10.5 ± 1.3 L/session. This met the preset noninferiority criteria, suggesting that mixed-HDF was noninferior to predilution HDF. Moreover, the β2-microglobulin reduction rate was greater in the mixed-HDF group than in the predilution HDF group, while mixed-HDF provided greater transmembrane pressure. There were no significant between-group differences in Kt/V urea levels, changes in predialysis hs-CRP levels, proportions of overhydration, or blood pressure values. Symptomatic intradialytic hypotension episodes and other adverse events occurred similarly in the two groups.
Conclusion
Use of mixed-HDF was comparable to predilution HDF in terms of delivered convection volume and clinical parameters. Moreover, mixed-HDF provided better β2-microglobulin clearance than predilution HDF.
9.Erratum: Correction of Affiliations in the Article “Clinical Characteristics and Treatment Outcomes in Children, Adolescents, and Young-adults with Hodgkin's Lymphoma: a KPHOG Lymphoma Working-party, Multicenter, Retrospective Study”
Jae Min LEE ; Jung Yoon CHOI ; Kyung Taek HONG ; Hyoung Jin KANG ; Hee Young SHIN ; Hee Jo BAEK ; Hoon KOOK ; Seongkoo KIM ; Jae Wook LEE ; Nack-Gyun CHUNG ; Bin CHO ; Seok-Goo CHO ; Kyung Mi PARK ; Eu Jeen YANG ; Young Tak LIM ; Jin Kyung SUH ; Sung Han KANG ; Hyery KIM ; Kyung-Nam KOH ; Ho Joon IM ; Jong Jin SEO ; Hee Won CHO ; Hee Young JU ; Ji Won LEE ; Keon Hee YOO ; Ki Woong SUNG ; Hong Hoe KOO ; Kyung Duk PARK ; Jeong Ok HAH ; Min Kyoung KIM ; Jung Woo HAN ; Seung Min HAHN ; Chuhl Joo LYU ; Ye Jee SHIM ; Heung Sik KIM ; Young Rok DO ; Jae Won YOO ; Yeon Jung LIM ; In-Sang JEON ; Hee won CHUEH ; Sung Yong OH ; Hyoung Soo CHOI ; Jun Eun PARK ; Jun Ah LEE ; Hyeon Jin PARK ; Byung-Kiu PARK ; Soon Ki KIM ; Jae Young LIM ; Eun Sil PARK ; Sang Kyu PARK ; Eun Jin CHOI ; Young Bae CHOI ; Jong Hyung YOON ;
Journal of Korean Medical Science 2021;36(4):e37-
10.Volumetric Assessment of Fusion Mass and Its Clinical Correlations in Posterior Lumbar Interbody Fusion Depending on the Type of Bone Graft
Jae Won LEE ; Quan You LI ; Kyoung-Tak KANG ; Bong-Soon CHANG ; Choon-Ki LEE ; Jin S. YEOM ; Ho-Joong KIM
Journal of Korean Society of Spine Surgery 2020;27(2):39-47
Objectives:
This study was conducted to analyze associations between the volume of the fusion mass and clinical outcomes 1 year after posterior lumbar interbody fusion (PLIF).Summary of Literature Review: No study has investigated associations between the size of the fusion mass and clinical outcomes after PLIF.
Materials and Methods:
The volume of the fusion mass and its clinical correlations after PLIF were analyzed in all patients and in subgroups. When a sufficient amount of local bone was available for grafting, only local bone without a graft extender was used (LbG group, n=20). If an inadequate amount of local bone was present for grafting, a local bone graft with porous hydroxyapatite bone chips was used (LbHa group, n=20). The same amount of demineralized bone matrix was used in both groups. The primary outcome was the relationship between the size of the fusion mass and clinical outcomes in all patients 1 year after surgery. The secondary outcome was a comparison of the size of the fusion mass and clinical outcomes by group.
Results:
The volume of the fusion mass was not correlated with any clinical outcomes 1 year after surgery, either in the overall group of patients or in the subgroup analysis.
Conclusions
The volume of the interbody fusion mass was not related to any clinical outcomes 1 year after surgery. Furthermore, in cases with an insufficient amount of local bone for grafting, porous hydroxyapatite could be a relatively good alternative as a graft extender.

Result Analysis
Print
Save
E-mail