1.Moyamoya disease in Korea.
Kyoung Hwa PARK ; Byoung Ho CHA ; Jun Su LEE ; Chang Jun COE
Journal of the Korean Child Neurology Society 1993;1(2):56-63
No abstract available.
Korea*
;
Moyamoya Disease*
2.Development of Computerized Surveillance Programs based on a Hospital Electronic Medical Records System.
Ja Hyun KANG ; Hong Bin KIM ; Ho Jun CHIN ; Kyoung Un PARK ; Eun Hwa CHOI
Korean Journal of Nosocomial Infection Control 2004;9(2):107-116
BACKGROUND: As information technology evolves rapidly computer-based surveillance systems for nosocomial infection have been developed. Well designed computerized system could provide an opportunity for improving, enlarging, and conducting hospital-wide surveillance more efficiently in the situation with limited resources. Recently, we launched a new computerized monitoring system in a hospital where digital medical information system has been operated without paper chart. METHODS: We developed a new surveillance program based on the total Electronic Medical Record (EMR) system. Numerous critical medical information can be easily accessible through this system without further work. This includes major demographic data, essential information from the inpatient medical record, the laboratory information system, and the pharmacy information, Comprehensive Clinical Data Repository (CDR) system was also developed. CDR is potentially very useful to conduct a hospital-wide surveillance by integrating all the available information. RESULTS: This system consists of several programs in the EMR and the CDR environment. In the EMR system, inquiry for patients with fever, case ascertainment and registration of nosocomial infections, inquiry for patients with indwelling devices, microbiological reports, and data on antibiotic prescriptions were included. The CDR has integrated comprehensive inquiries for frequency of major pathogens in clinical isolates and their trends of antibiotic resistance, nosocomial infection rates based on the duration of the devices or hospitalization, and the history of antimicrobial usage based on defined daily dosage. Data obtained from the EMR and the CDR systems could be easily accessed by infectious diseases specialists and healthcare workers of infection control services at any place within the hospital. A new reporting system has been built up to facilitate identification of notifiable diseases among the list of diagnoses on the EMR. In addition, the "Alert" notice was designed to highlight isolation precautions for indicated cases. CONCLUSION: This new computerized surveillance program might be a valuable model to which other hospitals can refer to develop newer version of programs in the future.
Clinical Laboratory Information Systems
;
Communicable Diseases
;
Cross Infection
;
Delivery of Health Care
;
Diagnosis
;
Drug Resistance, Microbial
;
Electronic Health Records*
;
Fever
;
Hospitalization
;
Humans
;
Infection Control
;
Information Systems
;
Inpatients
;
Medical Records
;
Pharmacy
;
Prescriptions
;
Specialization
3.Neuropathic thoracic spine due to fractured of ankylosing spondylitis and tabes dorsalis: A case report.
Seung Ho YUNE ; June Kyu LEE ; Jun Young YANG ; Kyoung Tai KIM
The Journal of the Korean Orthopaedic Association 1993;28(7):2355-2359
No abstract available.
Spine*
;
Spondylitis, Ankylosing*
;
Tabes Dorsalis*
4.Plate Designed for Wiring ( CHO Plate ).
Woo Shin CHO ; Jun O YOON ; Soo Ho LEE ; Kyoung Min NOH ; Yong Gab JEONG
The Journal of the Korean Orthopaedic Association 1998;33(5):1460-1467
Although intramedullary nailing is mostly used in the management of fractures in the long bone shaft, plate fixation is still alternative option in periprosthetic or metaphyseal fractures. For the rigid fixation during plating, sometimes we need wiring. Many surgeons experience slippage of wire resulting in loss of rigid fixation because plate and wire is so slippery and the diameter of bone is changing by level especially in the metaphyseal area. Wiring plate(CHO plate) was designed to prevent slippage. This plate has transverse holes for wires between screw holes on traditionally used dynamic compression plate. Sixteen fractures of long bone shaft were fixed with wiring plate and 11 cases which were followed up for more than one year were evaluated. There were periprosthetic fractures(4 cases), spiral or butterfly fractures(4 cases) and fractures of poor bone quality(two cases of malignancy and one case of osteoporosis). Nine cases were successfully reduced and the healed without loss of fixation. In two cases, delayed union and nonunion were observed due to wire breakage with plate loosening. Preliminarily, wiring plate fixation can be used for the periprosthetic fracture and one of alternative option in butterfly or spiral fracture and fracture in osteoporotic bone or pathologic fracture.
Butterflies
;
Fracture Fixation, Intramedullary
;
Fractures, Spontaneous
;
Periprosthetic Fractures
5.Intraoperative versus Postoperative Measurement in Total Knee Arthroplasty using Computer-Assisted Orthopaedic Surgery (CAOS): Accuracy of CAOS.
Dae Kyung BAE ; Kyoung Ho YOON ; Sang Jun SONG ; Seon Goo KIM ; Kyoung Jun PARK
The Journal of the Korean Orthopaedic Association 2005;40(2):168-173
PURPOSE: The purpose of this research was to compare the intra-operative and post-operative measured angle in total knee arthroplasty (TKA) and to evaluate the postoperative improvement in the mechanical axis. MATERIALS AND METHODS: Forty TKAs were performed using CAOS between February and May 2004. We measured the mechanical axis in the preoperative orthograms. After inserting the implant, we measured the femoral component angle (FCA), tibial component angle (TCA) and tibial component slope (TCS) using the verification tool in CAOS, on the post-operative orthogram and X-ray of the lateral tibial view, 2 observers measured the FCA, TCA, TCS and mechanical axis. RESULTS: The mean FCA, TCA and TCS using the verification tool in CAOS, were valgus 0.03+/-0.85degrees, valgus 0.49+/-1.02degrees, nd 4.26+/-1.64degrees. The mean FCA, TCA and TCS by observer 1 were valgus 0.67+/-1.24degrees, varus 0.54+/-1.54degrees, and 4.57+/-1.74degrees and those by observer 2 were valgus 0.48+/-1.17degrees, varus 0.52+/-1.44degrees, and 4.24+/-2.83degrees. There was a positive correlation between the measured angle by respective observers and the angle measured by the CAOS (p<0.05). The mechanical axis by observers 1 and 2 improved from varus 13.96degrees to valgus 0.04degrees and from varus 14.12degrees to valgus 0.08degrees respectively. CONCLUSION: CAOS affords the possibility of precisely placing the femoral and tibial components. The angles measured by the respective observers and in the CAOS were significantly correlated.
Arthroplasty*
;
Axis, Cervical Vertebra
;
Knee*
6.Clinical Evaluation of Depressed Newborns Following Cesarean Sections.
Ho Kyoung SONG ; Jong Ho LEE ; Jun Seuk CHEA ; Young Taek KIM
Korean Journal of Anesthesiology 1987;20(6):788-793
Between january 1, 1981 and December 31, 1986, 1,310 Cesarean sections (26.7%) were performed among 4,898 paturient women at St. Mary's pospital, Catholic Medical College. The perioperative condition of the newborns along with morbidity and mortality after Cesarean section wha analyzed. The incidencea of Cesarean sections between 1981 and 1986 were 25.0% 27 .6%, 23.4%, 29.5%, 31.2% and 27.1%, respectively. The anesthetic methods employed were inhalation anesthesia with thiopental sodium for induction and nitrous oxide-oxygen-halothane for maintenance of anesthesia. This study did net include the 76 cases of lumbar epidural or spinal technique performed during this Period. Based on one minute Apgar scores, 82 infants (6.26%) were assessed as moderately (score 4-6) depressed, and 44 infants (3.36%) were rated as severely (score 0~3) depressed. Twenty (45.5%) of the severely depressed newborns were promptly resuscitated and given ade- quate treatement, but 11 infants (25.0%) did not survive. The incidence of idiopathic respiratory distress syndrome (IRDS) in this study was 9 cases (0.79%) Ammong 7he total 1,310 cases; this induded 7 cases of premature birth or low birth weight and 2 cases of aspiration pneumonia. The mortality of the IRDS group was 4 of 9 cases (44.4%). Among the severely depressed group, the time from induction to delivery was five minutes in 8 case? (18.2%) , six to ten minutes in 22 cases (57.777) and more than 11 minutes in 14 cases (31.8%) . The pro7n7stic status of newborn babies was evaluated with respect to the anesthetic procedure and the outcome of deliveries by Cesarean sections performed between 1981 and 1986 at St. Mar's Hospital, Catholic Medical College, Seoul, Korea.
Anesthesia
;
Anesthesia, Inhalation
;
Cesarean Section*
;
Female
;
Humans
;
Incidence
;
Infant
;
Infant, Low Birth Weight
;
Infant, Newborn*
;
Korea
;
Mortality
;
Pneumonia, Aspiration
;
Pregnancy
;
Premature Birth
;
Seoul
;
Thiopental
7.Clinical evaluation of lung cancer in patients younger than 40 years.
Jun Ho MOON ; Kyoung Tae CHA ; Yong HUR ; Wook Su AHN ; Byung Yul KIM ; Jung Ho LEE
The Korean Journal of Thoracic and Cardiovascular Surgery 1993;26(11):861-865
No abstract available.
Humans
;
Lung Neoplasms*
;
Lung*
8.Detection of Antibody to Candida albicans Proteinase in Sera from C. albicans - Cultured Patients and Healthy Controls.
Kyoung Ho LEE ; Woon Seob SHIN ; Hyun Sook PARK ; Young UH ; In Ho JANG ; Kap Jun YOON ; Choon Myung KOH
Journal of the Korean Society for Microbiology 1997;32(3):307-314
To investigate whether anti-Candida proteinase antibody could be a diagnostic marker, we examined seroreactivity to proteinase in sera from 90 healthy controls and 8 of C. albicans culture-positive patients. Previously we purified proteinases of C. albicans, C. tropicalis, and C. parapsilosis using a series of chromatographic steps consisting of DEAE- Sepharose, Sephacryl S-200, and size-exclusion HPLC. ELISA and Western blot technique were adopted to examine seroreactivity of C. albicans proteinase with sera. On ELISA, the seroreactivities of healthy controls and C. albicans-cultured patients were 0.601 +- 0.014 (mean+SEM), and 0.695 +- 0.079, respectively (P=0.084, t-test). In C. albicans-cultured patients, the positive rate was 62.5% (5/8) and the positive rate of healthy controls was 39% (35/90). On Western blot analysis, C. albicans proteinase molecule was blotted by all sera tested. But the intensity of blotted band was different with the same dilution of sera; the intensity of C. albicans proteinase molecule band blotted by 2 sera of 3 healthy control's sera was distinctively lower than that by C. albicans-cultured patients sera. However, all sera including C. albicans-cultured patient's sera did not blot the proteinase secreted by C. tropicalis and C. parapsilosis. It is necessary to collect sequential sera of patients with candidiasis and to establish a cut-off value for ELISA or serum dilution for Western blot analysis that will give reliable test sensitivity and specificity.
Blotting, Western
;
Candida albicans*
;
Candida*
;
Candidiasis
;
Chromatography, High Pressure Liquid
;
Enzyme-Linked Immunosorbent Assay
;
Humans
;
Peptide Hydrolases
;
Sensitivity and Specificity
;
Sepharose
9.Pseudohydronephrosis in Two-Phase Spiral CT of the Abdomen.
Kyoung Ho LEE ; Seung Hyup KIM ; Jeong Yeon CHO ; Young Jun KIM ; Kyoung Mo YEON
Journal of the Korean Radiological Society 1997;37(5):889-892
PURPOSE: To assess the incidence and causes of pseudohydronephrosis in the abdominal two-phase (arterial and portal) spiral CT. MATERIALS AND METHODS: This study included 115 renal pelvises of 62 patients (hepatocellular carcinoma in 36, gastric carcinoma in 10 and others in 16 patients) whose entire renal pelvises were imaged in both phases of abdominal spiral CT. Arterial and portal phase scans were obtained 30 and 65-70 seconds after the injection of 100 mL of non-ionic contrast media (370mg I/mL) at a rate of 2.5 mL/sec, respectively. The renal pelvis was considered to be dilated when the shortest diameter of renal pelvis exceeded 1cm as seen on CT. In each patient, a plain film was obtained 5-10 minutes after the injection of contrast media for CT to confirm the hydronephrosis. RESULTS: Seven renal pelvises were dilated on spiral CT. All of them were pseudohydronephrosis with prominent renal pelvis and two of them were extrarenal pelvises. In 115 renal pelvises, there was one case of true hydronephrosis due to a ureteral stone not suspected clinically. CONCLUSION: A 6% incidence of pseudohydronephrosis due to prominent renal pelvis should be considered in interpreting the abdominal two-phase spiral CT.
Abdomen*
;
Contrast Media
;
Humans
;
Hydronephrosis
;
Incidence
;
Kidney Pelvis
;
Pelvis
;
Tomography, Spiral Computed*
;
Ureter
10.Efficacy of Computer Assisted Surgery in Revision Total Knee Arthroplasty.
Dae Kyung BAE ; Kyoung Ho YOON ; Seon Goo KIM ; Kyoung Jun PARK
The Journal of the Korean Orthopaedic Association 2006;41(6):974-980
PURPOSE: The purpose of this study was to analyze the accuracy of the mechanical axis and implant positions postoperatively and to evaluate the radiology results of computer assisted navigation surgery for bone cutting and ligament balancing in revision TKA. MATERIALS AND METHODS: 13 consecutive revision TKAs were performed by a single surgeon with use of computer assisted surgery (CAS) from July 2004 to August 2005. At the revision, the mean age was 64.7 years. The mean interval from the index arthroplasty was 9.8 years. The cause of the revision included 11 cases of polyethylene wear and 2 cases of loosening. Two observers measured the mechanical axis, position of the implants, and level of joint lines. RESULTS: By observer I, the mechanical axis improved from varus 11.9degrees to valgus 1.5degrees, and the mean alpha, bets, gamma and delta angles were 95.3, 90.8, 3.9 and 87.6degrees respectively. From observer II, the mechanical axis improved from varus 11.6degrees to valgus 1.6degrees, and mean alpha, beta, gamma and delta angles were 95.5, 90.5, 4.1 and 87.9degrees respectively. The measured angles from observers I and II showed a good correlation. CONCLUSION: Accurate bone cutting and verification in each step are possible using real time information provided by the CAS. The mechanical axis, component positions, joint line could be checked and adjusted with feedback of navigation system. Information about flexion and extension gap and ligament balancing could be verified during revision surgery.
Arthroplasty*
;
Axis, Cervical Vertebra
;
Joints
;
Knee*
;
Ligaments
;
Polyethylene
;
Surgery, Computer-Assisted*