1.Pediatric and Parents' Attitudes Towards COVID-19 Vaccines and Intention to Vaccinate for Children
Soo-Han CHOI ; Yoon Hee JO ; Kyo Jin JO ; Su Eun PARK
Journal of Korean Medical Science 2021;36(31):e227-
Background:
Coronavirus disease 2019 (COVID-19) vaccination is necessary to reach herd immunity and essential for mitigating the spread of the pandemic. In May 2021, the US FDA and the EU have expanded the emergency use authorization for a COVID-19 vaccine to children aged 12 to 15. The aim of this study was to investigate parental acceptability of COVID-19 vaccination for their children, factors affecting their acceptability, and children's perceptions of COVID-19 vaccines in Republic of Korea.
Methods:
We conducted a questionnaire survey at two tertiary hospitals from May 25, 2021 to June 3, 2021. Subjects were parents having children under 18 years and children aged 10–18 years.
Results:
Two hundred twenty-six parents and 117 children aged 10–18 years were included in the final analysis. Overall, 76.5% and 64.2% of parents intended to get vaccinated against COVID-19 and intended to have their children vaccinated, respectively. However, only 49.6% of children responded that they would get COVID-19 vaccination. In the multivariate analysis, high confidence in the safety of COVID-19 vaccines (adjusted odds ratio [AOR], 4.87; 95% confidence interval [CI], 1.32–24.12), parents' willingness to vaccinate themselves (AOR, 19.42; 95% CI, 6.85–64.00), and awareness of the need to vaccinate children against COVID-19 (AOR, 13.15; 95% CI, 4.77–41.27) were associated with positive factors intention to vaccinate their children.
Conclusion
This study provides insight into how parents think about the COVID-19 vaccine for their children in South Korea. Our findings could be referenced in establishing a policy for childhood COVID-19 vaccination in the future.
2.Pediatric and Parents' Attitudes Towards COVID-19 Vaccines and Intention to Vaccinate for Children
Soo-Han CHOI ; Yoon Hee JO ; Kyo Jin JO ; Su Eun PARK
Journal of Korean Medical Science 2021;36(31):e227-
Background:
Coronavirus disease 2019 (COVID-19) vaccination is necessary to reach herd immunity and essential for mitigating the spread of the pandemic. In May 2021, the US FDA and the EU have expanded the emergency use authorization for a COVID-19 vaccine to children aged 12 to 15. The aim of this study was to investigate parental acceptability of COVID-19 vaccination for their children, factors affecting their acceptability, and children's perceptions of COVID-19 vaccines in Republic of Korea.
Methods:
We conducted a questionnaire survey at two tertiary hospitals from May 25, 2021 to June 3, 2021. Subjects were parents having children under 18 years and children aged 10–18 years.
Results:
Two hundred twenty-six parents and 117 children aged 10–18 years were included in the final analysis. Overall, 76.5% and 64.2% of parents intended to get vaccinated against COVID-19 and intended to have their children vaccinated, respectively. However, only 49.6% of children responded that they would get COVID-19 vaccination. In the multivariate analysis, high confidence in the safety of COVID-19 vaccines (adjusted odds ratio [AOR], 4.87; 95% confidence interval [CI], 1.32–24.12), parents' willingness to vaccinate themselves (AOR, 19.42; 95% CI, 6.85–64.00), and awareness of the need to vaccinate children against COVID-19 (AOR, 13.15; 95% CI, 4.77–41.27) were associated with positive factors intention to vaccinate their children.
Conclusion
This study provides insight into how parents think about the COVID-19 vaccine for their children in South Korea. Our findings could be referenced in establishing a policy for childhood COVID-19 vaccination in the future.
3.Effect of Cobalt-Chromium Alloy Surface Treatment When Bonding With 4-Meta/mma-Tbb Resin.
Jae Sik JIN ; Kyo Han KIM ; Cheong Hee LEE ; Kwang Hun JO
The Journal of Korean Academy of Prosthodontics 2000;38(4):510-525
The effects of pretreatment of Co-Cr alloy, including two adhesive primers that contain either MDP or MAC-10, and silicoating on the bond. The results obtained as follows : Strength of 4-META/MMA-TBB resin were investigated using FT-IR SEM, and EDAX. in the SEM observation of surface morphologies, the sandblasted specimen exibited a very rough surface, whereas the surfaces of the two groups primed with either MDR or MAC-10 were covered with a layer of primer, and the surface morphology of the silicoated specimen remained almost the same after sandblasting. Before the thermocycling tests, the group treated with MDP demonstrated the highest mean tensile bond strength and the sandblasted group showed the lowest bond strength. After 20,000 themocyling, the mean tensile bond strength of the sandblasted group exhibited a 50% reduction in bond strength, while the other showed a 20~30% reduction. Observation of the metal-resin interface revealed that in all groups the resin permeated the rough surface formed by sandblasting thereby producing a mechnical bond between the metal and the resin, It was also found that thermocycling resulted in a gap formation at the metal-resin interface of the specimens, and the sandblasted group exhibited a larger gap width than the other groups. in fracture mode, all specimens indicated a cohesive fracture within the resin before thermocycling. However, thermocyling produced adhesive failure at the edge of the resin-metal interface in most specimens, The sandblasted group, which exhibited the lowest bond strength after thermocycling, also demonstrated the largest area of adhexive failure.
Adhesives
;
Alloys*
4.Effect of Stress on Cardiovascular Autonomic Nervous Activity in Recovering Myocardial Infarction Patients and Normal Controls Measured by Power Spectral Analysis.
Tae Il LEE ; Kyo Won CHOI ; Young Jin KIM ; Dong Gu SHIN ; Young Jo KIM ; Bong Sup SHIM ; Hyen Woo LEE ; Ki Ho LEE
Korean Circulation Journal 1994;24(1):24-37
BACKGROUND: Mental stress prebably leads to disease by the effect on autonomic nervous system, especially on cardiovascular nervous system it leads deleterious effects ranging from the apperarence or worsenig of ischemia to lethal arrhythmia or sudden death. Especially after myocardial infarction this risks were increased. PURPOSE & METHODS: In order to assess the effect of postural change and arithmetic test on the state of autonomic nervous system in patients with AMI(acute myocardial infarction) autoregressive power spectral analyses were applied to 21 healthy subjects(51.9+/-6.5 years) and 20 AMI patients(55.3+/-7.4 years) during supine, standing and arithmetic test. RESULTS: R-R interval and systolic blood pressure decreased during standing compared with during supine position but there were no remarkable changes during arithmetic test compared with during supine position. In two groups, both during standing and during arithmetic test, compared with during supine position, the remarkable increase of LF(low frequency) spectral parameters(Nu, p<0.001) and decrease of HF(high frequency) spectral parameter(Nu, p<0.001) were observed. And during arithmetic test, compared with during standing, the remarkable increase of LF spectral parameter(Nu, p<0.01) and decrease of HF spectral parameter(Nu, p<0.01) were observed. LF/HF ratio and LFCCV/HFCCV ratio, so an index of sympatho-vagal balance, significantly increased during standing and during arithmetic test compared with during supine position and the increase was more prominent during arithmetic test(p<0.05). There was no significant difference of spectral parameters beteen two groups. CONCLUSION: In conclusion, sympathetic activity increased during standing and during arithmetic test. Especially, during arithmetic test it induced only sympathetic activity to increase remarkably without significant hemodynamic changes. The state of autonomic nervous system 7-10 days after AMI was not different from that of healthy subjects. Among the spectral parameters, Nu was more useful than either PSD or CCV in assessing autonomic nervous activity.
Arrhythmias, Cardiac
;
Autonomic Nervous System
;
Autonomic Pathways
;
Blood Pressure
;
Death, Sudden
;
Hemodynamics
;
Humans
;
Ischemia
;
Myocardial Infarction*
;
Nervous System
;
Supine Position
5.Influence of Balloon Size and Morphology of Coronary Stenosis on Elastic Recoil after Percutaneous Transluminal Coronary Angioplasty.
Kyo Won CHOI ; Jun Young KWEON ; Young Jin KIM ; Tae Il LEE ; Dong Gu SHIN ; Young Jo KIM ; Bong Sup SHIM ; Hyun Woo LEE
Korean Circulation Journal 1995;25(2):459-468
BACKGROUND: The immediate result of coronary balloon angioplasty was influenced by plastic and elastic changes of the vessel wall. After successful coronary angioplasty, the minimal luminal diameter of the dilated coronary artery segment was generally smaller than the diameter of the largest balloon catheter at the maximal inflation pressure. Several mechanisms could explain this phenomenon, including vasoconstriction, subintimal or intraplaque bleeding or edema and platelet or thrombus deposition. In addition, whenever balloon inflation results in overdistension of elastic components of the arterial wall, some degree of elastic recoil may occur. METHODS: To evaluate magnitude of elastic recoil after percutaneous transluminal coronary angioplasty in relation to lesion morphology and other procedure-related variables, 141 coronary lesions were selected from patients with acute myocardial infarction, stable angina, unstable angina and post myocardial infarction angina undergoing successful coronary angioplasty. Coronary angiograms were recorded before and after angioplasty, and during dilatation of balloon. The computer measuring program was used for the assessment of balloon diameters and coronary luminal diameters. RESULTS: 1) Of all 141 coronary lesions, percent diameter stenosis before angioplasty averaged 74.2% and after angioplasty averaged 22.5%. 2) Residual diameter stenosis was directly related to the degree of elastic recoil, the greater the elastic recoil the more severe the residual lesion immediately after angioplasty. The increase in elastic recoil corresponded to a increase in the balloon/artery ratio(p<0.05). 3) The residual diameter stenosis tended to decrease in segments dilated with an oversized balloon than with an undersized balloon(p<0.05). 4) The elastic recoil increased significantly in the subgroups of coronary segments dilated with an oversized balloon, of eccentric lesion, and type C lesion(p<0.05). 5) Percent residual stenosis was more sever in eccentric stenosis dilated with undersized balloon than in concentric stenosis. 6) Elastic recoil was greater in type C coronary segment dilated with an oversized balloon than with an undersized balloon(<0.05). 7) The lesion dilated with oversize non-compliant balloon showed more elastic recoil than with oversize compliant balloon(p<0.05). CONCLUSION: Factors such as oversized balloon, eccentric lesion, type C lesion, and non-compliant balloon significantly affected increase of the elastic recoil.
Angina, Stable
;
Angina, Unstable
;
Angioplasty
;
Angioplasty, Balloon, Coronary*
;
Blood Platelets
;
Catheters
;
Constriction, Pathologic
;
Coronary Stenosis*
;
Coronary Vessels
;
Dilatation
;
Edema
;
Hemorrhage
;
Humans
;
Inflation, Economic
;
Myocardial Infarction
;
Phenobarbital
;
Plastics
;
Thrombosis
;
Vasoconstriction
6.A case of free-floating left atrial ball thrombus in mitral stenosis.
Young Jin KIM ; Tea Il LEE ; Kyo Won CHOI ; Seung Ho KANG ; Dong Gu SIN ; Young Jo KIM ; Bong Sup SHIM ; Hyun Woo LEE ; Eun Pyo HONG
Yeungnam University Journal of Medicine 1993;10(1):237-244
A free-floating ball thrombus in the left atrium is a rare complication of the mitral valvular disease. A 53-year-old man was admitted for pain and paresthesia on both legs. On admission he had auscultatory sign of mitral stenosis and mitral regurgitation, and the roentgenogram of his chest revealed a slight pulmonary ve..ous congestion, enlargement of the pulmonary conus and cardiomegaly. Laboratory findings including complete blood counts, coagulation studies and blood chemistry were normal. An echocardiographic examination revealed a mitral stenosis and a free-floating ball thrombus in the left atrium. We performed the emergent open heart surgery for removal of the ball thrombus and mitral replacement successfuly with Duromedics 29 mm valve. The size of thrombus was 39 X 32 X 30 mm.
Blood Cell Count
;
Cardiomegaly
;
Chemistry
;
Conus Snail
;
Echocardiography
;
Estrogens, Conjugated (USP)
;
Heart Atria
;
Humans
;
Leg
;
Middle Aged
;
Mitral Valve Insufficiency
;
Mitral Valve Stenosis*
;
Paresthesia
;
Thoracic Surgery
;
Thorax
;
Thrombosis*
7.Determinants of Successful Percutaneous Transluminal Coronary Angioplasty.
Kyo Won CHOI ; Jun Young KWEON ; Yeung Jin KIM ; Tae Il LEE ; Dong Gu SHIN ; Young Jo KIM ; Bong Sup SHIM ; Hyun Woo LEE ; Sam Beom LEE
Yeungnam University Journal of Medicine 1994;11(2):230-239
In Order to evaluate determinants of successful percutaneous transluminal coronary angioplasty (PTCA), PTCA was performed for 172 coronary arterial lesions in 120 patients(89 male, 31 female) at Yeungnam university hospital from Sep. 1992 to Aug 1993. The corinary artery luminal diameter at the site of the original stenosis was eveluated from end-diastolic frames of identical projections of the preangioplasty and immediate post angioplasty. The coronary luminal and balloon diameters were measured with using of computer measuring system. Overall success rate of 172 attempted lesions was 87.2%. Success rate of female patients was 93.5% and higher than those of male patients. According to the clinical diagnosis, success rate in stable angina was 93.7% and higher than those of post myocardial infarction angina, unstable angina and acute myocardial infarcrion. Success rate of American Heart Association type C lesion was 65.5% and lower those of type A(95.7%), type B (89.%). There was significantly difference in preangioplasty luminal stenosis, elastic recoil and length of lesion between successful PTCA group and failed PTCA group. Success rate of lesion location at a bed >45° and presence of intracoronary thrombus were lower than than those of other angiographic findings. In coclusion, primary angioplasty success was affected by specific angiographic factors, Stenosis severity, thrombus, lesion location at a bend >45°, elastic recoil, and length of lesion were the principle of determinants of coronary angioplasty success rate.
American Heart Association
;
Angina, Stable
;
Angina, Unstable
;
Angioplasty
;
Angioplasty, Balloon, Coronary*
;
Arteries
;
Constriction, Pathologic
;
Diagnosis
;
Female
;
Humans
;
Male
;
Myocardial Infarction
;
Phenobarbital
;
Thrombosis
8.Electrohydaulic Lithotripsy (EHL) of Retained Common Hile Duct Stone with Choledochoscopy.
Dong Wan LEE ; Dae Hwan KANG ; Jin Do KIM ; Chang Ho DO ; Mong JO ; Ung Suk YANG ; Yuoon HUE ; Han Kyo MOON
Korean Journal of Gastrointestinal Endoscopy 1990;10(2):355-357
Electrohydraulic lithotripsy (EHL) is a method used to breakup the stone by electric discharge in the presence of liquid medium. Recently we experienced a case of successful common bile duct stone removal after EHL during choledochoscopy via T-tube tract, which was the first case of EHL in biliary tract stone in Korea. A 65-year-old female patient was admitted to our hospital because of generalized pruritus after cholcystectomy with T-tube insertion. Obtained cholangiogram showed retained CBD stone which was implssible to remove by Dormian basket and tto dissolute by monooctanoin. After only one session of EHL, we can disintergrat CBD stone into several small pieces and removal of stone was easily done by Basket. After Small cut endoscopic sphincterotomy (EST) remained distal impacted stone was freely passed and control choledochoscopy and cholangiogram showed no remained stone. We think that EHL may be play a potential role in removal of biliary tract stones as in urinary tract stones.
Aged
;
Biliary Tract
;
Common Bile Duct
;
Female
;
Humans
;
Korea
;
Lithotripsy*
;
Pruritus
;
Sphincterotomy, Endoscopic
;
Urinary Calculi
9.Change of working length in curved canals by various instrumentation techniques.
Jeong Im JO ; Myoung Uk JIN ; Young Kyung KIM ; Sung Kyo KIM
Journal of Korean Academy of Conservative Dentistry 2006;31(1):30-35
To evaluate the change of working length with various instrumentation techniques in curved canals, working length and canal curvature were determined before and after canal instrumentation in buccal or mesial canals of extracted human molars. Stainless steel K-files (MANI(R), Matsutani Seisakusho Co. Takanezawa, Japan), nickel-titanium K-files (Naviflex NT(TM), Brassler, Savannah, USA), ProFile(R), and ProTaper(TM) (Dentsply-Maillefer, Ballaigues, Switzerland) were used to prepare the canals with crown-down technique. In two hand instrumentation groups, coronal flaring was made with Gates Glidden burs. Apical canals were instrumented until apical diameter had attained a size of 30. Positional relation between the tooth apex and the #10 K-file tip was examined by using AutoCAD 2000 (Autodesk Corp., San Rafael. CA, USA) under a stereomicroscope before and after coronal flaring, and after apical instrumentation. Degree of canal curvature was also measured with Schneider's method in radiographs. Data of working length and canal curvature changes were statistically analyzed with one-way ANOVA and Tukey's studentized range test. Working length and canal curvature were decreased significantly in each step in all instrumentation groups. Coronal flaring using Gates Glidden burs in hand instrument groups and whole canal instrumentation using stainless steel hand K-files caused significantly more working length change than in ProFile instrumentation group (p < 0.05). The result of this study demonstrates that all of the above kinds of instrumentation in curved canals cause reduction of working length and canal curvature at each instrumentation steps, and hand instrumentation causes more working length change than ProFile.
Dental Instruments
;
Hand
;
Humans
;
Molar
;
Stainless Steel
;
Tooth Apex
10.Diagnostic Performance of Blood Culture Bottles for Abscess Culture in Patient with Abdominal Soft Tissue Abscess
Kyo Jin JO ; Chulhun L. CHANG ; Jae-Yeon HWANG ; Su Eun PARK
Pediatric Infection & Vaccine 2021;28(2):118-123
Culture tests are very important in choosing the appropriate antibiotics for bacterial infections. In some cases, bacteria that could not be identified in standard culture bottles could be detected using blood culture bottles. A previously healthy 13-year-old boy visited our emergency room. He experienced pain, redness, and hardness of periumbilical skin and a fever for five days. There was no history of abdominal surgery and penetrating trauma.Computed tomography showed abscess with cellulitis at the periumbilical soft tissue with no congenital anomaly. Ultrasonography-guided aspiration was performed, and about 8.5 mL of the purulent abscess was aspirated. The abscess was cultured using blood culture bottle. The pus grew Actinomyces radingae and Clostridium ramosum. When performing the pus culture, using blood culture bottles can be more effective and rapid than the standard culture method for the detection of bacterial pathogens.