1.Relationship Between Mobility and Self-Care Activity in Children With Cerebral Palsy.
Kyeongwon KIM ; Jin Young KANG ; Dae Hyun JANG
Annals of Rehabilitation Medicine 2017;41(2):266-272
OBJECTIVE: To investigate the factors influencing the development of self-care activity, and the association between mobility and self-care activity in children with cerebral palsy (CP). METHODS: A total of 63 CP children aged ≥4 years, were studied retrospectively. Children with severe intellectual disability or behavioral problems were excluded. The relationship between the Gross Motor Function Classification System (GMFCS), the Manual Ability Classification System (MACS), and the Pediatric Evaluation of Disability Inventory (PEDI) was analyzed. Simple and multiple linear regression analyses were conducted for continuous variables, such as verbal intelligence quotient (IQ) and PEDI subscales. RESULTS: Final evaluation was done for 25 children, ranging from 4 to 11 years of age. According to GMFCS levels, the differences in PEDI-self-care scores, showed statistically borderline significance (p=0.051). Conversely, differences in PEDI-self-care scores according to CP types and MACS levels were not statistically significant. Simple linear regression analysis showed that PEDI mobility and PEDI social function significantly influence the PEDI self-care. Multiple linear regression analysis showed that PEDI mobility was the only factor significantly influencing PEDI self-care in children aged ≥7 years (R²=0.875, p=0.03). CONCLUSION: Mobility is important for the acquisition of self-care abilities in children with CP aged ≥7 years.
Activities of Daily Living
;
Cerebral Palsy*
;
Child*
;
Classification
;
Humans
;
Intellectual Disability
;
Intelligence
;
Linear Models
;
Mobility Limitation
;
Problem Behavior
;
Retrospective Studies
;
Self Care*
2.Ultrasonography Detected Missed Lunate Volar Dislocation Associated With Median Neuropathy: A Case Report.
Annals of Rehabilitation Medicine 2017;41(4):709-714
Lunate and perilunate dislocations are uncommon, but they have clinical importance because complications, such as median neuropathy and avascular necrosis of the lunate, can occur. Although early diagnosis enabling early surgical treatment is crucial for preventing long-term sequelae, these dislocations are frequently missed in the initial assessment. Imaging tools, such as plain radiography, magnetic resonance imaging, ultrasonography, and electrodiagnostic studies, have been used for diagnosis. The proper choice of initial evaluation tools is important for making an accurate early diagnosis. Here we present a case of lunate dislocation associated with median neuropathy in which ultrasonography, along with the electrodiagnostic study and plain radiography, played an important diagnostic role in detecting structural abnormalities. This case report reveals the complementary diagnostic role of ultrasonography in initial assessment and provides ultrasonographic images of lunate dislocation as a cause of median neuropathy.
Diagnosis
;
Dislocations*
;
Early Diagnosis
;
Lunate Bone
;
Magnetic Resonance Imaging
;
Median Neuropathy*
;
Necrosis
;
Radiography
;
Ultrasonography*
3.Ultrasound Dimensions of the Rotator Cuff and Other Associated Structures in Korean Healthy Adults.
Kyeongwon KIM ; Hong Geum KIM ; Daeheon SONG ; Jung Yoon YOON ; Myung Eun CHUNG
Journal of Korean Medical Science 2016;31(9):1472-1478
In evaluating patients complaining of shoulder pain, ultrasonography is an emerging imaging tool due to convenience, low cost, high sensitivity and specificity. However, normative values of ultrasound dimensions of the shoulder to be compared with pathologic findings in Korean adults are not provided yet. We evaluated the ultrasound dimensions of the rotator cuff, long head of biceps tendon, deltoid muscle and acromioclavicular joint in Korean healthy adults. Shoulder ultrasonography was performed on 200 shoulders from 100 healthy adults. The dimensions of the thickness of rotator cuff (supraspinatus, infraspinatus, subscapularis tendon), deltoid muscle, long head of biceps tendon, subacromial subdeltoid bursa, and acromioclavicular joint interval were measured in a standardized manner. Differences in measurements among sex, age, and dominant arms were compared. The thickness of rotator cuff tendons (supraspinatus, infraspinatus, subscapularis) and deltoid muscle were significantly different between men and women. The thickness of subacromial subdeltoid bursa was significantly different between men and women for non-dominant side. In rotator cuff tendon measurements, the differences between dominant and non-dominant shoulders were not significant, which means the asymptomatic contralateral shoulder can be used to estimate the normal reference values. When stratified by age divided by 10 years, the measurements of supraspinatus, subscapularis and deltoid thickness showed tendency of increase with the age. The acromioclavicular joint interval, on the other hand, revealed decreasing tendency. This report suggests normative values of ultrasound dimensions of healthy Korean population with varying age, and can be useful as reference values in evaluating shoulder pathology, especially in rotator cuff tendon pathology.
Acromioclavicular Joint
;
Adult*
;
Arm
;
Deltoid Muscle
;
Female
;
Hand
;
Head
;
Humans
;
Male
;
Pathology
;
Reference Values
;
Rotator Cuff*
;
Sensitivity and Specificity
;
Shoulder
;
Shoulder Pain
;
Tendons
;
Ultrasonography*
4.Preferred Compression Threshold and Release Time in Quiet and Noisy Conditions for Elderly Korean Hearing Aid Users.
Woojae HAN ; Junghak LEE ; Jinsook KIM ; Kyeongwon LEE ; Dongwook KIM
Journal of Audiology & Otology 2017;21(3):133-139
BACKGROUND AND OBJECTIVES: Listeners with sensorineural hearing loss want to compensate for their narrow dynamic range from appropriate compression functions of hearing aids. The present study aimed to determine which compression threshold and release time of nonlinear hearing aids might affect speech recognition and speech quality judgments. SUBJECTS AND METHODS: Ten elderly listeners with symmetrical moderate-to-severe sensorineural hearing loss participated in the study. To compare two compression threshold (31 dB SPL vs. 61 dB SPL) and two release time (50 ms vs. 500 ms) conditions, subjects’ speech recognition was measured using the Korean version of the Hearing in Noise Test in both quiet and noisy situations. All subjects were also asked to rate the degree of speech quality in terms of loudness, sharpness, clarity, and background noise immediately after completing the speech recognition test. RESULTS: Although no significant difference emerged in speech recognition thresholds between the two compression thresholds in the quiet situation, the compression threshold of 31 dB SPL showed a lower (or better) signal-to-noise ratio of speech recognition compared to that of 61 dB SPL. The release times of 50 and 500 ms did not statistically differ in both quiet and noisy situations. Subjective categories were found to be louder and clearer in the 50 ms release time for quiet and noisy, respectively. CONCLUSIONS: We expect that these patterns of current results will apply for better-fitting protocol of elderly Korean hearing aid users.
Aged*
;
Hearing Aids*
;
Hearing Loss, Sensorineural
;
Hearing*
;
Humans
;
Judgment
;
Noise
;
Signal-To-Noise Ratio
5.Preferred Compression Threshold and Release Time in Quiet and Noisy Conditions for Elderly Korean Hearing Aid Users.
Woojae HAN ; Junghak LEE ; Jinsook KIM ; Kyeongwon LEE ; Dongwook KIM
Journal of Audiology & Otology 2017;21(3):133-139
BACKGROUND AND OBJECTIVES: Listeners with sensorineural hearing loss want to compensate for their narrow dynamic range from appropriate compression functions of hearing aids. The present study aimed to determine which compression threshold and release time of nonlinear hearing aids might affect speech recognition and speech quality judgments. SUBJECTS AND METHODS: Ten elderly listeners with symmetrical moderate-to-severe sensorineural hearing loss participated in the study. To compare two compression threshold (31 dB SPL vs. 61 dB SPL) and two release time (50 ms vs. 500 ms) conditions, subjects’ speech recognition was measured using the Korean version of the Hearing in Noise Test in both quiet and noisy situations. All subjects were also asked to rate the degree of speech quality in terms of loudness, sharpness, clarity, and background noise immediately after completing the speech recognition test. RESULTS: Although no significant difference emerged in speech recognition thresholds between the two compression thresholds in the quiet situation, the compression threshold of 31 dB SPL showed a lower (or better) signal-to-noise ratio of speech recognition compared to that of 61 dB SPL. The release times of 50 and 500 ms did not statistically differ in both quiet and noisy situations. Subjective categories were found to be louder and clearer in the 50 ms release time for quiet and noisy, respectively. CONCLUSIONS: We expect that these patterns of current results will apply for better-fitting protocol of elderly Korean hearing aid users.
Aged*
;
Hearing Aids*
;
Hearing Loss, Sensorineural
;
Hearing*
;
Humans
;
Judgment
;
Noise
;
Signal-To-Noise Ratio
6.Investigation of Filamentous Fungi Producing Safe, Functional Water-Soluble Pigments.
Young Mok HEO ; Kyeongwon KIM ; Sun Lul KWON ; Joorim NA ; Hanbyul LEE ; Seokyoon JANG ; Chul Hwan KIM ; Jinho JUNG ; Jae Jin KIM
Mycobiology 2018;46(3):269-277
The production of water-soluble pigments by fungal strains indigenous to South Korea was investigated to find those that are highly productive in submerged culture. Among 113 candidates, 34 strains that colored the inoculated potato dextrose agar medium were selected. They were cultured in potato dextrose broth and extracted with ethanol. The productivity, functionality (radical-scavenging activities), and color information (CIELAB values) of the pigment extracts were measured. Five species produced intense yellowish pigments, and two produced intense reddish pigments that ranked the highest in terms of absorbance units produced per day. The pigment extracts of Penicillium miczynskii, Sanghuangporus baumii, Trichoderma sp. 1, and Trichoderma afroharzianum exhibited high radical-scavenging activity. However, the S. baumii extract showed moderate toxicity in the acute toxicity test, which limits the industrial application of this pigment. In conclusion, P. miczynskii KUC1721, Trichoderma sp. 1 KUC1716, and T. afroharzianum KUC21213 were the best fungal candidates to be industrial producers of safe, functional water-soluble pigments.
Agar
;
Colorimetry
;
Efficiency
;
Ethanol
;
Fungi*
;
Glucose
;
Korea
;
Penicillium
;
Solanum tuberosum
;
Toxicity Tests, Acute
;
Trichoderma
7.Anatomical Localization of Motor Points of the Abductor Hallucis Muscle: A Cadaveric Study.
Asayeon CHOI ; Na Yeon KWON ; Kyeongwon KIM ; Youngkook KIM ; Jeehae OH ; Hyun Mi OH ; Joo Hyun PARK
Annals of Rehabilitation Medicine 2017;41(4):589-594
OBJECTIVE: To identify the anatomical motor points of the abductor hallucis muscle in cadavers. METHODS: Motor nerve branches to the abductor hallucis muscles were examined in eight Korean cadaver feet. The motor point was defined as the site where the intramuscular nerve penetrates the muscle belly. The reference line connects the metatarsal base of the hallux (H) to the medial tubercle of the calcaneus (C). The x coordinate was the horizontal distance from the motor point to the point where the perpendicular line from the navicular tuberosity crossed the reference line. The y coordinate was the perpendicular distance from the motor point to the navicular tuberosity. RESULTS: Most of the medial plantar nerves to the abductor hallucis muscles divide into multiple branches before entering the muscles. One, two, and three motor branches were observed in 37.5%, 37.5%, and 25% of the feet, respectively. The ratios of the main motor point from the H with respect to the H-C line were: main motor point, 68.79%±5.69%; second motor point, 73.45%±3.25%. The mean x coordinate value from the main motor point was 0.65±0.49 cm. The mean value of the y coordinate was 1.43±0.35 cm. All of the motor points of the abductor hallucis were consistently found inferior and posterior to the navicular tuberosity. CONCLUSION: This study identified accurate locations of anatomical motor points of the abductor hallucis muscle by means of cadaveric dissection, which can be helpful for electrophysiological studies in order to correctly diagnose the various neuropathies associated with tibial nerve components.
Cadaver*
;
Calcaneus
;
Electromyography
;
Foot
;
Hallux
;
Metatarsal Bones
;
Muscles
;
Tibial Nerve