1.Effect of Lights-Out at Night Time on Body Weight, Physiological Variables, and Behavioral Status in Premature Infants.
Kyeong Nam LEE ; Bo Min SEO ; Deog Hwan MOON ; Ga Won JEON ; Jong Beom SIN
Neonatal Medicine 2016;23(2):102-107
PURPOSE: This study was conducted to assess the effects of lights-out at nighttime on body weight, physiological variables, and behavioral status in premature infants and to provide basic data for applying lights-out at night time in premature infants. METHODS: Premature infants of over 32 weeks' corrected age were included in this study (January 2015-June 2015), and were allocated to two groups according to the lights-out at night for 5 hours: study group and control group. Lights-out was applied to the study group from midnight for five hours in a quiet environment. RESULTS: Fifty-two infants were included in the study: 26 in the study group and 26 in the control group. Growth rates of body weight, height, and head circumference were higher in the study group compared to the control group, but there were no statistical differences. In the physiological variables, heart rate decreased by 6.9 beats per minute in the study group, but it increased by 2.7 beats per minute in the control group (P<0.0001) during applied 5 hours at night. Anderson Behavioral State Score decreased in the study group compared to the control group (P=0.042). CONCLUSION: Lights-out at night decreased the heart rate and made the behavioral status more stable. To understand the effects of lights-out on long-term growth and development of premature infants at the highest risk of delayed growth and development, further studies with a larger number of premature infants are needed.
Body Weight*
;
Circadian Rhythm
;
Growth and Development
;
Head
;
Heart Rate
;
Humans
;
Infant
;
Infant, Newborn
;
Infant, Premature*
2.Confirmation of Supraorbital Nerve and Its Branch in the Supraorbital Notch with Ultrasound Guidance.
Ji Hee HONG ; Sung Mun LEE ; Kyeong Hwan SEO
Keimyung Medical Journal 2016;35(2):128-132
A 55-year-old female with severe herpes zoster related forehead pain radiating to anterior and posterior scalp visited our pain clinic. The right side forehead pain with numerical rating score of 7 had persisted in spite of antiviral and anticonvulsant medication. We blocked the right supraorbital nerve under ultrasound guidance, and obtained the proper pain relief. In this case, we would like to present the method to identify the supraorbital notch or foramen and possible visualization of the supraorbital nerve.
Female
;
Forehead
;
Herpes Zoster
;
Humans
;
Methods
;
Middle Aged
;
Pain Clinics
;
Scalp
;
Ultrasonography*
3.Power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow: A technical report
Song Hee OH ; Yu Kyeong SEO ; Gyu Tae KIM ; Yong Suk CHOI ; Eui Hwan HWANG
Imaging Science in Dentistry 2019;49(4):301-306
PURPOSE: This report presents a procedure for performing power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow and illustrates its application to practical patient cases.MATERIALS AND METHODS: The salivary gland was scanned using ultrasound equipment (GE LOGIQ5 Expert® device; GE Medical Systems, Milwaukee, WI, USA) to identify pathological findings related to the patient's chief complaint. To identify the orifice of the main duct, it should be cannulated using a lacrimal dilator. After inserting the catheter into the cannulated main duct, the position of the catheter within the duct was confirmed by ultrasound. A contrast agent was injected until the patient felt fullness, and ultrasound (B-mode) was used to confirm whether the contrast agent filled the main canal and secondary and tertiary ducts. Then, power Doppler ultrasound was performed to determine whether the salivary gland had increased blood flow.RESULTS: In 2 cases in this report, a power Doppler ultrasound scan showed a significant increase in blood flow after contrast medium injection, which was not observed on a preoperative scan.CONCLUSION: Power Doppler ultrasound was found to be a simple, safe, and effective tool for real-time sialography monitoring.
Catheters
;
Humans
;
Salivary Glands
;
Sialography
;
Ultrasonography
;
Vasodilation
4.Efficacy of transversus abdominis plane block in postoperative pain management of laparoscopic totally extraperitoneal inguinal hernia repair: a propensity score-matched analysis
Gimin LEE ; Sanghyuk MOON ; Nagyeong KIM ; Daeun BAEK ; Nak-Hoon SON ; Kyeong Hwan SEO ; Eunyoung JUNG
Annals of Surgical Treatment and Research 2025;108(1):57-63
Purpose:
Transversus abdominis plane (TAP) block is a promising technique for postoperative pain control. In this study, we aimed to evaluate the efficacy of the TAP block in managing postoperative pain after laparoscopic totally extraperitoneal (TEP) inguinal hernia repair.
Methods:
In this retrospective study, medical records of patients who had received ultrasonography-guided TAP blocks after surgery from January 2019 to August 2023 were reviewed and compared with those of patients who had not received. Propensity score matching was controlled for age as a confounder. Postoperative pain levels were measured using the numeric rating scale (NRS).
Results:
After matching, 95 patients were included in each group. The TAP block group (2.7 vs. 4.0, P < 0.001) had significantly lower NRS scores immediately and early postoperative pain than the control group (1.9 vs. 2.5, P < 0.001). However, there was no significant difference between the 2 groups in terms of postoperative complications (P > 0.05).
Conclusion
TAP block is effective and safe for managing immediate and early postoperative pain in laparoscopic TEP inguinal hernia repair and does not increase the risk of complications.
5.Efficacy of transversus abdominis plane block in postoperative pain management of laparoscopic totally extraperitoneal inguinal hernia repair: a propensity score-matched analysis
Gimin LEE ; Sanghyuk MOON ; Nagyeong KIM ; Daeun BAEK ; Nak-Hoon SON ; Kyeong Hwan SEO ; Eunyoung JUNG
Annals of Surgical Treatment and Research 2025;108(1):57-63
Purpose:
Transversus abdominis plane (TAP) block is a promising technique for postoperative pain control. In this study, we aimed to evaluate the efficacy of the TAP block in managing postoperative pain after laparoscopic totally extraperitoneal (TEP) inguinal hernia repair.
Methods:
In this retrospective study, medical records of patients who had received ultrasonography-guided TAP blocks after surgery from January 2019 to August 2023 were reviewed and compared with those of patients who had not received. Propensity score matching was controlled for age as a confounder. Postoperative pain levels were measured using the numeric rating scale (NRS).
Results:
After matching, 95 patients were included in each group. The TAP block group (2.7 vs. 4.0, P < 0.001) had significantly lower NRS scores immediately and early postoperative pain than the control group (1.9 vs. 2.5, P < 0.001). However, there was no significant difference between the 2 groups in terms of postoperative complications (P > 0.05).
Conclusion
TAP block is effective and safe for managing immediate and early postoperative pain in laparoscopic TEP inguinal hernia repair and does not increase the risk of complications.
6.Efficacy of transversus abdominis plane block in postoperative pain management of laparoscopic totally extraperitoneal inguinal hernia repair: a propensity score-matched analysis
Gimin LEE ; Sanghyuk MOON ; Nagyeong KIM ; Daeun BAEK ; Nak-Hoon SON ; Kyeong Hwan SEO ; Eunyoung JUNG
Annals of Surgical Treatment and Research 2025;108(1):57-63
Purpose:
Transversus abdominis plane (TAP) block is a promising technique for postoperative pain control. In this study, we aimed to evaluate the efficacy of the TAP block in managing postoperative pain after laparoscopic totally extraperitoneal (TEP) inguinal hernia repair.
Methods:
In this retrospective study, medical records of patients who had received ultrasonography-guided TAP blocks after surgery from January 2019 to August 2023 were reviewed and compared with those of patients who had not received. Propensity score matching was controlled for age as a confounder. Postoperative pain levels were measured using the numeric rating scale (NRS).
Results:
After matching, 95 patients were included in each group. The TAP block group (2.7 vs. 4.0, P < 0.001) had significantly lower NRS scores immediately and early postoperative pain than the control group (1.9 vs. 2.5, P < 0.001). However, there was no significant difference between the 2 groups in terms of postoperative complications (P > 0.05).
Conclusion
TAP block is effective and safe for managing immediate and early postoperative pain in laparoscopic TEP inguinal hernia repair and does not increase the risk of complications.
7.Validation of the Korean Version of the Clinical Assessment Interview for Negative Symptoms.
Seon Kyeong JANG ; Seon Cheol PARK ; Kee Hong CHOI ; Jung Seo YI ; Joong Kyu PARK ; Jung Suk LEE ; Seung Hwan LEE
Psychiatry Investigation 2017;14(4):413-419
OBJECTIVE: Clinical Assessment Interview for Negative Symptoms (CAINS) has recently been developed to improve measurement of negative symptoms in schizophrenia. We performed a multi-center study to validate the Korean version of the CAINS (CAINS-K) and explore potential cultural variation. METHODS: One hundred eighty schizophrenia patients diverse in demographic and illness profile were recruited from four centers in Korea. Along with the CAINS-K, the Scale for the Assessment of Negative Symptoms (SANS), Brief Psychiatric Rating Scale (BPRS), Calgary Depression Scale for Schizophrenia (CDSS), a self-report measure of behavioral inhibition and activation (BIS/BAS) and neurocognitive tasks were administered to verify external validities. RESULTS: The CAINS-K showed high internal-consistency (0.92) and inter-rater reliability (0.77). Exploratory Factor Analysis replicated a two-factor structure of the original scale including motivation/pleasure and expression deficits dimensions. Korean patients tended to report lower pleasure compared to American patients in the prior study. The CAINS-K showed an adequate convergent validity with the SANS, negative symptoms of the BPRS, and BAS. A divergent validity was supported as the CAINS-K showed zero or only weak correlations with other symptoms of the BPRS, depression from the CDSS, and neurocognitive tasks. CONCLUSION: The CAINS-K demonstrated high internal consistency and adequate external validities, and is expected to promote studies on negative symptoms in Korean patients with schizophrenia.
Brief Psychiatric Rating Scale
;
Depression
;
Humans
;
Korea
;
Pleasure
;
Schizophrenia
8.Volumetric accuracy of cone-beam computed tomography.
Cheol Woo PARK ; Jin ho KIM ; Yu Kyeong SEO ; Sae Rom LEE ; Ju Hee KANG ; Song Hee OH ; Gyu Tae KIM ; Yong Suk CHOI ; Eui Hwan HWANG
Imaging Science in Dentistry 2017;47(3):165-174
PURPOSE: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. MATERIALS AND METHODS: Four geometric objects (cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. RESULTS: The mean VE ranged from −4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. CONCLUSION: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.
Americas
;
Colloids
;
Cone-Beam Computed Tomography*
;
Imaging, Three-Dimensional
;
Seoul
9.Spiral CT Findings of Chromophobe Renal Cell Carcinoma: Correlation with Pathologic Features and Prognosis.
Kyu Ran CHO ; Cheol Min PARK ; Hwan Hoon CHUNG ; Hyoung Rae KIM ; Bum Jin PARK ; Young Hen LEE ; Bo Kyeong SEO ; Sang Hoon CHA ; Chang Hee LEE ; Kyoo Byung CHUNG
Journal of the Korean Radiological Society 2002;46(1):57-62
PURPOSE: To describe the spiral CT findings of CRCC and to correlate these with the pathologic features, nuclear grading, tumor staging, and prognosis. MATERIALS AND METHODS: We encountered eleven cases of CRCC among 167 cases of histopathologically proven RCC, retrospectively evaluating the spiral CT findings of CRCC including tumor size, internal texture, attenuation, margin, and the involvement of veins or lymph nodes. In addition, the CT findings were correlated with the pathologic features, Fuhrman's nuclear grade, Robson's staging, and the prognosis. Between 27 and 80 (mean, 49.6) months later, the follow-up CT scans of tea patients were examined for tumor recurrence. RESULTS: All tumors, which ranged in size from 2.5 to 15 (mean, 7.7) cm, were solid and well demarcated from renal parenchyma. Pre-contrast CT scans showed that their attenuation was equal to (n=1) or slightly lower (n=10) than that of renal parenchyma, and on early and delayed phase post-contrast enhanced scans, attenuation was low in all cases. In three, focal areas in which attenuation was lower than in the rest of the tumor were observed; histopathologically, these represented hyalinization. There was neither venous nor lymph node involvement, and no distant metastasis. Histopathologic examination demonstrated cystic change (n=1), hemorrhage or necrosis (n=5), complete encapsulation (n=3) and perirenal fat infiltration (n=3). Nuclear grading was II (n=6) or III (n=5), and tumor staging was I (n=8) or II (n=3). Among the five cases in which the nuclear grade was III, three were stage I and two were stage II. Follow-up scans showed no evidence of tumor recurrence, and all patients survived. CONCLUSION: Pre-, early- and late-phase post-contrast enhonced spiral CT scans showed that the attenuation of a CRCC was lower than that of renal parenchyma. Even where the nuclear grade was higher, a well-demarcated soild mass was observed, the tumor stage was lower and the prognosis better.
Carcinoma, Renal Cell*
;
Follow-Up Studies
;
Hemorrhage
;
Humans
;
Hyalin
;
Lymph Nodes
;
Necrosis
;
Neoplasm Grading
;
Neoplasm Metastasis
;
Neoplasm Staging
;
Prognosis*
;
Recurrence
;
Retrospective Studies
;
Tea
;
Tomography, Spiral Computed*
;
Tomography, X-Ray Computed
;
Veins
10.Estimates of Radiation Doses and Cancer Risk from Food Intake in Korea.
Eun Kyeong MOON ; Wi Ho HA ; Songwon SEO ; Young Woo JIN ; Kyu Hwan JEONG ; Hae Jung YOON ; Hyoung Soo KIM ; Myung Sil HWANG ; Hoon CHOI ; Won Jin LEE
Journal of Korean Medical Science 2016;31(1):9-12
The aim of this study was to estimate internal radiation doses and lifetime cancer risk from food ingestion. Radiation doses from food intake were calculated using the Korea National Health and Nutrition Examination Survey and the measured radioactivity of 134Cs, 137Cs, and 131I from the Ministry of Food and Drug Safety in Korea. Total number of measured data was 8,496 (3,643 for agricultural products, 644 for livestock products, 43 for milk products, 3,193 for marine products, and 973 for processed food). Cancer risk was calculated by multiplying the estimated committed effective dose and the detriment adjusted nominal risk coefficients recommended by the International Commission on Radiation Protection. The lifetime committed effective doses from the daily diet are ranged 2.957-3.710 mSv. Excess lifetime cancer risks are 14.4-18.1, 0.4-0.5, and 1.8-2.3 per 100,000 for all solid cancers combined, thyroid cancer, and leukemia, respectively.
Adolescent
;
Adult
;
Cesium Radioisotopes/chemistry
;
Child
;
Child, Preschool
;
*Eating
;
Food Contamination, Radioactive/*analysis
;
Humans
;
Infant
;
Infant, Newborn
;
Iodine Radioisotopes/chemistry
;
Neoplasms, Radiation-Induced/*etiology
;
Nutrition Surveys
;
Radiation Dosage
;
Republic of Korea
;
Young Adult