1.Sources and Influencing Factors of Children Blood Lead in China
Journal of Environment and Health 2007;0(07):-
Lead is a kind of poisonous heavy metal which is widely existed in our environment. It is so harmful for children’s health. The whole society has paid much attention to this problem all the time. Blood lead level is an important index which can measure how seriously children have been exposed to lead. By consulting the papers on the studies of children's blood lead levels,the sources and influencing factors of blood lead levels of children in China were reviewed in the present paper,meanwhile,some suggestions were provided to decrease the lead contact probability and improve children's health.
2.Acute liver injury and expression of P-selectin in serum of mice induced by agkistrodon halys pallas venom
Zhefeng ZHONG ; Lipu DENG ; Kun CHEN
Chinese Journal of Emergency Medicine 2012;21(5):503-506
Objective To explore the relationship between pathological changes of liver,serum ALT,expression of P-selectin in serum of mice and different dose of venom,the poisoning time induced by Agkistrodon Halys Pallas venom.Methods Using two -factor factorial design,72 male Kunming mice of clean grade were randomly ( random number) divided into 9 groups (n =8).As per the different doses of snake venom injected and different lengths of time after venom injected,the 9 groups were 0-dose (0.0 mg/kg) 3 hours after saline given group,0-dose 8 hours after saline given group,0-dose 24 hours after saline given group,low-dose (0.5 mg/kg) 3 hours after venom given group,low-dose 8 hours after venom given group,low-dose 24 hours after venom given,high-dose ( 1.0 mg/kg) 3 hours after venom given group,high-dose 8 hours after venom given group and high-dose 24 hours after venom given group.The pathological change of liver tissue was determined,and ALT and expression of P-selectin in serum were detected.Results In the venom given groups,the liver histopathologic scores,serum ALT value and expression of Pselectin in serum were significantly higher than those in control group ( P < 0.05 ),and those in high-dose group were higher than those in low-dose group (P < 0.05 ),and those in 8h groups were higher than those in 3h groups (P<0.05),and those in 24 h groups were higher than those in 8 h groups (P <0.05).As the dose of venom increased and the length of time after venom given extended,the liver histopathologic scores,serum ALT and expression of P-selectin in serum were higher.A positive correlation between Pselectin expression and liver histopathologic scores was found after correlation analysis ( r =0.98,P <0.05 ).Conclusions Agkistrodon snake venom can cause acute liver injury with elevated ALT and Pselectin in mice.As higher dose of venom given and longer length of time after venom given extended,more serum ALT and P-selectin are produced.Between acute liver injury and high expression of P-selectin exists a correlation,suggesting overexpression of P-selectin is one of the mechanisms of acute liver injury induced by Agkistrodon Halys Pallas venom.
3.Protective mechanism of hepatic ischemic postconditioning
Fei SONG ; Kun LI ; Zhong ZENG
International Journal of Surgery 2008;35(12):826-828
lschemic postconditioning(IPo)is a way that after long ischemia on liver graft,animals are given one or several brief reperfusion-ischemia before persistent reperfusion to improve the hepatic tolerance and relieve the ischemie reperfusion injury.It has been proved an effective and controlled method to attenuate the ischemic reperfusion injury.Protective mechanism of ischemic postconditioning on hepatic graft is related with protecting sinus hepaticus endotheliocyte and hepatic microcirculation,relieving hepatic cells injury and inflammatory reaction induced by oxygen free radicals,relieving calcium ovedoad in hepatic cells and mitochondria,regulating apoptosis genes,transforming ion channels condition in mitochondria.This article will makes a brief review on protective mechanism ofhepatic ischemic posteanditioning.
4.Concentration Determination of Voriconazole in Human Plasma by UPLC-MS/MS and Its Clinical Application
Jiao ZHONG ; Kun HAO ; Zejun PEI
China Pharmacy 2016;27(29):4064-4066,4067
OBJECTIVE:To develop a method for concentration determination of voriconazole in human plasma and apply it in the clinic. METHODS:UPLC-MS/MS method was adopted. Using ketoconazole as internal standard,the determination was per-formed on Shim-pack VP-ODS column with mobile phase consisted of water(containing 1‰ formic acid and 2 mmol/L ammonium acetate)-acetonitrile(gradient elution)at flow rate of 0.3 ml/min and column temperature of 40℃.The electrospray ion source,pos-itive ionizing pattern and multiple reaction monitoring were used;the mass transition ion-pairs of voriconazole and internal standard were m/z 351.2→282.2 and m/z 532.1→490.2. RESULTS:The linear range of voriconazole were 1-10 000 ng/ml (r=0.999 5,n=5),and the limit of quantitation was 1 ng/ml;RSDs of inter-day and intra-day were all lower than 10%;method recovery was higher than 90%(RSD<8%),and extraction recovery was higher than 70%(RSD<8%). The plasma concentrations of voriconazole in 10 patients with invasive fungal infection determined by this method were 507.33-7 011.24 ng/ml,and those of 3 patients were outside the recommended treatment concentration range. CONCLUSIONS:The established method is fast,accurate and sensitive,and can be applied for the therapeutic drug monitoring of voriconazole.
5.Impact of Cold Wave on Mortality of Cerebra-cardiovascular Diseases in Beijing:a Case-crossover Study
Kun ZHONG ; Ling LIU ; Jinliang ZHANG
Journal of Environment and Health 1992;0(02):-
Objective To estimate the impact of cold wave on daily death of cerebra-cardiovascular diseases in Beijing by using case-crossover design. Methods The data of death counts was provided by Beijing Center for Disease Control and Prevention while the meteorological data was provided by Institute of Urban Meteorology,China Meteorological Administration (CMA),Beijing. The impact of six cold waves from Jan 1,1998 to Jun 30,2000 on daily death of cerebra-cardiovascular diseases were analyzed by using 1∶1 one-directional retrospective design and 1∶2 bi-directional symmetry control design. The cases were the people who dead during winter. Controls were the seventh day before or after the date of cases (or the fourteenth day). Results There were six cold waves in the investigation duration. The third cold wave in which minimum temperature declined obviously with decreasing humidity and increasing air pressure had significantly statistical significance in OR and the lag time of this cold wave was 0 day,the OR values were 1.500 (95%CI:1.032-2.181) for cardiovascular disease (CVD),respectively 1.913 (95%CI:1.066-3.432) for acute myocardial infarction,1.679 (95%CI:1.139-2.474) for cerebra-vascular disease(CBD) respectively. The other five cold waves do not have significant impact on cerebra-cardiovascular diseases. Conclusion Most cold waves studied in Beijing do not impact the daily death counts caused by cerebra-cardiovascular diseases. The cold wave with significant increased air pressure may increase the risk of death of cerebra-cardiovascular diseases without any lag time in Beijing.
6.The application of quality specifications derived from biological variation in routine chemistry external quality assessment and internal quality control
Falin HE ; Yu BAI ; Wei WANG ; Kun ZHONG ; Zhiguo WANG
Chinese Journal of Laboratory Medicine 2012;35(6):531-537
Objective To discuss the application of allowable total error (Tea) and allowable imprecision derived from biological variation in routine chemistry external quality assessment ( EQA) and internal quality control (IQC) and set up quality specifications of routine chemistry in our country.Methods Data of test items including K,Na,CI,Ca,P,Glu,Urea,UA,Cre,Alb,TP,TC,TG,AST,ALT,Tbil,ALP,AMY,CK,LDH,Fe,Mg,Cu,Zn and GGT was collected and evaluated by a nationwide EQA.At the same time the coefficients of variation (CVs) of these test items during the month were acquired from the IQC reports of each laboratory and then the results were analyzed.Results Percent of pass was different in these test items based on Tea derived from biological variation in EQA results.Except for items of CI,Mg,Cu and Zn,about 80% of participant laboratories could achieve the minimum performance of biological variation.About 80% of participant laboratories could achieve the desired performance of biological variation for K,P,Glu,Urea,UA,Cre,TC,TG,ALT,AST,Tbil,AMY,CK,LDH,Fe and GGT.About 80% of participant laboratories could achieve the optimum performance of biological variation for Urea,UA,TC,TG,ALT,AST,Tbil,C K,and GGT.And the IQC results showed that acceptable percents of different items based on three allowable imprecision were different.More than 80% of participant laboratories could achieve the minimum allowable imprecision for K,P,Glu,Urea,UA,TC,TG,ALT,AST,Tbil,AMY,CK,LDH,Dbil,Fe,GGT,the desirable imprecision for P,Urea,UA,TG,ALT,AST,Tbil,CK,Dbil,Fe,GGT and the optimum imprecision for TG,ALT,CK,Dbil,Fe.Conclusions The quality specifications derived from biological variation can be as evaluation criteria for EQA and IQC in order to know the detection ability of each laboratory more completely and objectively,set up quality specifications derived from allowable total error and allowable imprecision in routine chemistry and to provide basis for mutual recognition of routine chemistry test results.
7.Assessment of longitudinal systolic ventricular function in children with single ventricle using velocity vector imaging
Lijun CHEN ; Yuqi ZHANG ; Kun SUN ; Shuwen ZHONG ; Zhifang ZHANG
Chinese Journal of Ultrasonography 2010;19(7):557-560
Objective To investigate the longitudinal systolic ventricular function of children with single ventricle, and to appraise the feasibility and clinical value of velocity vector imaging (VVI) on assessing it. Methods The study group consisted of 30 patients with functional single ventricle. The control group consisted of 30 age- and gender-matched normal children. Using Sequoia C512 echocardiography machine,the peak velocity(V),peak displacement(D) ,strain(S) ,and strain rate(SR) were measured. Results Basel and median velocities,as well as basel and median displacements of rudimentary chamber side(RCS), were lower than those of septum[Basel velocity (1. 93 ± 0. 71)cm/s vs (3. 53 ± 1. 07)cm/s;Median velocity (1.19±0. 57)cm/s vs (2. 03 ± 0. 90) cm/s; Basel displacement (2. 53 ± 1.65) mm vs (6.21 ± 2. 12)mm;Median displacement(1. 26 ± 1. 06)mm vs (3. 21 ± 1.37)mm]. The values of strain of all the six segments of single ventricle were significantly lower than Corresponding segments of the control group [ basel nonrudimentary chamber side(NRCS) ( - 16. 17 ± 4. 37) % vs ( - 19. 66 ± 3. 47) % ; Median NRCS ( - 15. 23 +4.36)% vs (-19.64± 4. 75)%; Apical NRCS (-13.84 ± 5.79)% vs ( - 16. 7 ± 4. 15)%; Basel RCS(-10. 54±5.35)% vs (-19.49±3. 74)%;Median RCS ( - 10. 16 ± 5. 26)% vs ( -20. 83 ± 3. 82)% ;Apical RCS ( - 10. 97 ± 5. 22) % vs C - 18. 11 ± 4.43) %]. Aside from basel strain rates of NRCS, strain rates of all the other five segments of single ventricle were significantly lower than Corresponding segments of the control group [Median NRCS ( - 1. 21 ± 0. 42)s-1 vs (- 1.49 ± 0. 24)s-1 ;Apical NRCS ( - 1.10 ±0.41)s-1 vs (-1.47 ± 0.24)s-1;Basel RCS ( - 1.07 ± 0. 35) s-1 vs (- 1. 49 ± 0. 22) s-1; Median RCS (-0.97± 0.34)s-1 vs ( -1.48 ± 0. 20)s-1 (Apical RCS ( - 0. 93 ± 0. 39)s-1 vs ( - 1. 48 ± 0. 22)s-1]. Conclusions Longitudinal systolic ventricular function is impaired in children with functionally single ventricle. VVI can be used to asses ventricular systolic performance in children with functionally single ventricular.
8.Investigation and Analysis of the Coefficient of Variation of Internal Quality Control of Homocysteine
Lu ZHANG ; Wei WANG ; Falin HE ; Kun ZHONG ; Zhiguo WANG
Journal of Modern Laboratory Medicine 2015;(4):132-134
Objective To carry out the current status of internal quality control by statistical analysis of the Internal Quality Control (IQC)data of homocysteine in 2014 March.Methods Web-based External Quality Assessment (EQA)system was used to collect IQC data of homocysteine from 292 EQA participant laboratories nationwide.The data include thecoefficient of variation (CV)of IQC data under control in March 2014 and long-term cumulative data.Acceptable rates of CVs of two-lot internal quality controls in homocysteine were calculated according to 5 criteria,that were 1/3TEa,1/4TEa and the speci-fications based on biological variation including the minimal,appropriate and optimal allowable imprecision.The instrument the participant laboratories used were sorted into 6 groups and the passing rate of each group were calculated by the 5 crite-ria.Results 292 laboratories reported the data of level 1 IQC for homocysteine,106 of which reported the data of level 2 IQC.The passing rate was different according to different criteria.The passing rate had few difference by the criteria of 1/3TEa and the minimal allowable imprecision based on biological variation,which were from 63.36% to 76.42%.It was also true for 1/4TEa and the appropriate allowable imprecision based on biological variation,which were from 34.25% to 57.55. The passing rate was only 10.62%~16.98% by the criteria of appropriate allowable imprecision based on biological varia-tion.Statistical results showed that instruments the participant mainly used were HITACHI (77/292),Olympus (61/292), Roche (19/292),Beckman (14/292),Abbott (10/292)and Simens (10/292).The passing rates of all the instrument group had few difference except Simens group.Conclusion Most of the laboratories could meet the criteria of 1/3TEa and the min-imal allowable imprecision based on biological variation.But less than half of the laboratories could meet the criteria of 1/4TEa and the appropriate and optimal allowable imprecision based on biological variation.The precision performance of ho-mocysteine among laboratories needs further improvement.
9.Investigation and analysis of reference intervals of tumor markers testing in China
Yaling XIAO ; Wei WANG ; Falin HE ; Kun ZHONG ; Zhiguo WANG
Chinese Journal of Laboratory Medicine 2015;(5):349-352
Objective To describe the reference intervals and their sources of tumor markers in clinical laboratories all over China.And make a comparison of difference between different testing systems.Methods The questionnaires about reference intervals of tumor markers testing were distributed to participants.The information was collected by external quality assessment software system based on website, which including upper and lower limits, sources, validation information and testing systems.The analytes were AFP, CEA, total-PSA, CA125, CA153, CA199, ferritin and free-PSA. The participants were classified according to the testing systems they used.The mean, median, maximum and minimum of each group were calculated using Microsoft Excel 2007.The difference of reference intervals between different testing systems were compared by Kruskal-Wallis test.Results The main source of reference intervals was instructions of testing system manufactures ( 83.1% for mean of 8 ratios ) .The next in sequence were instructions of reagent manufactures(8.4% for mean), National Guide to Clinical Laboratory Procedures (4.6%for mean), determined by their own laboratory(2.0% for mean) and the rest (1.9% for mean). There were 48.0% ( 1 906/3 967 ) of analytes whose reference intervals had been validated.Difference of reference intervals which was with P value of Kruskal-Wallis test with <0.05 was found between different testing system groups except the upper limit of free prostate specific antigen ( PSA ) .Conclusions Most clinical laboratories establish the reference intervals of tumor markers on the basis of instructions of testing system manufactures.The reference intervals among different testing systems have statistically significance.
10.Survey and Analysis for Maternal Serum Marker of Prenatal Screening in Second Trimester in 2 0 1 5
Falin HE ; Wei WANG ; Kun ZHONG ; Shuai YUAN ; Zhiguo WANG
Journal of Modern Laboratory Medicine 2017;32(1):154-156,164
Objective To investigate the dates of 477 Chinese prenatal screening centers for previous half year analyse prena-tal screening status and provide recommendations for quality control.Methods All China prenatal screening centers were sent the data via the National Quality Assessment Scheme.This covered the software used,the risk cut-offs,monthly sample throughput,monthly median MoM of AFP,hCG,β-HCG,freeβ-HCG and uE3,monthly screening positive rate for trisomy 21,trisomy 18 and Open Neural Tube Defect.Results Screening protocol were versatile,with 73.48% (133/181)used two-marker model,24.31% (44/181)used three-marker model and 2.21% used four-marker model.About the software used, 350 laboratories never updated the screening parameters,89 laboratories had updated their median or parameter by manufac-turers,24 laboratories had updated the parameters by themselves.Cut-offs differed between laboratories.59.91% (275/459) used 1/270 as their cutoffs for trisomy 21.66.22% (296/447)used 1/350 as their cutoff for trisomy 18 and 96.52% (361/374)used cutoffs between 2.0~2.5 MOM for ONTD.Results of monthly median MOM:the percentage of laboratories that all six monthly median MOM within the target of 0.90~1.10 was 46.69% (155/332)for AFP,20.0% (4/20)for hCG, 29.17% (28/96)forβ-HCG,15.66% (31/198)for freeβ-HCG and 4.82% (11/228)for uE3.The percentage of laborato-ries that all six monthly median MOM within the target of 0.95~1.05 was 14.16% (47/332)for AFP,0% (0/20)for hCG,4.17% (4/96)forβ-HCG,12.63% (25/198)for freeβ-HCG and 4.82% (11/228)for uE3.About screening positive rate,there were difference of trisomy 2 1 positive rate in the same laboratory within the six month.Conclusion There were variations types of screening protocol,different kinds of soft platform,randomness of choice or update of medians or other important parameters and great difference in awareness of quality control.It would be taken effective and practical quality control measures to help laboratories improve quality control.