1.A research on the shear stress for“myocardial bridge-coronary artery”analog device
Hao DING ; Hailian LAN ; Kun SHANG
Chinese Journal of Tissue Engineering Research 2014;(7):1033-1038
BACKGROUND:It is difficult to make an exact conclusion about the correlation between atherosclerosis and hemodynamic wal shear stress because of the complexity of the hemodynamic environment in the field of atherosclerosis research.
OBJECTIVE:To analyze the relationship between characteristics of mural coronary artery hemodynamics parameters and atherosclerosis through myocardial bridge-coronary artery analog device.
METHODS:Myocardial bridge-coronary artery analog device was used to simulate experiments in vitro. In the condition of keeping any related parameters unchanged, such as system temperature, the average flow rate and heart rate, we observed and recorded the changes of proximal and distal mean value and oscil atory value of shear stress of mural coronary artery by regulating the oppression level of myocardial bridge to mural coronary artery.
RESULTS AND CONCLUSION:Under 0%oppression, there was no significant difference in distal and proximal mean value and oscil atory value of shear stress of mural coronary artery. Under 50%oppression, the proximal oscil atory value of shear stress was significantly larger than that in the distal end. Under 80%oppression, mean shear stress in the distal end was larger than that in the proximal end. Oscil atory value of shear stress in the proximal end was larger than that in the distal end. With increased oppression, the mean shear stress in the distal end was higher than that in the proximal end, but oscil atory value in the proximal end was higher than that in the distal end. These results indicated that the increase of the oscil atory value of the proximal shear stress of mural coronary artery is an important factor for the occurrence of atherosclerosis.
2.Clinic application of the allogenic skin for the cut of the compartment syndrome
Xiaopeng SHANG ; Haiying LIU ; Kun WANG
Orthopedic Journal of China 2006;0(18):-
[Objective]To observe the therapeutic efficacy of low temperature deposited allogenic skin for cutting of the compartment syndrome.[Method]sixty-eight patients suffering from the fracture of limb or electrical injuries and complicated compartment syndrome were elected.The patients were divided into experimental group and control group.Low temperature deposited allogenic skin was used for the cutting of the open decompression in the experimental group.Petrolatum gauze was used in the control group.The analgesic effect,dressing times,local effusion and wound ihealing time were observed after operation.[Result]The pain value,dressing times and local exudation in the experimental group had a significant decrease when compared with the control group(P
3.Design of a testing system for antithrombotic pressure circulatory equipment.
Xun ZHOU ; Haipo CUI ; Kun SHANG ; Zhelong LI ; Enqing CHENG
Journal of Biomedical Engineering 2014;31(1):192-195
A new type of testing system used for antithrombotic pressure circulatory equipment has been developed, which realized a new method for the calibration of pressure sensor. Multi-path control and acquisition functions are achieved by this method based on human-computer interaction testing system. The precision of pressure sensor is ob tained by polynomial fitting for each test point using linear interpolation method. The result showed that the precision test of pressure sensor could be realized easily and efficiently, using the developed testing system, and the parameters of pressure sensor could be calibrated effectively, so that it could be accurately used in the antithrombotic pressure circulatory equipment. The developed testing system has a prosperous future in the aspects of promotion and application.
Algorithms
;
Calibration
;
Equipment Design
;
Humans
;
Monitoring, Physiologic
;
instrumentation
;
Pressure
;
Thrombosis
;
diagnosis
4.Testing system design and analysis for the execution units of anti-thrombotic device.
Zhelong LI ; Haipo CUI ; Kun SHANG ; Yuehua LIAO ; Xun ZHOU
Journal of Biomedical Engineering 2015;32(1):187-191
In an anti-thrombotic pressure circulatory device, relays and solenoid valves serve as core execution units. Thus the therapeutic efficacy and patient safety of the device will directly depend on their performance. A new type of testing system for relays and solenoid valves used in the anti-thrombotic device has been developed, which can test action response time and fatigue performance of relay and solenoid valve. PC, data acquisition card and test platform are used in this testing system based on human-computer interaction testing modules. The testing objectives are realized by using the virtual instrument technology, the high-speed data acquisition technology and reasonable software design. The two sets of the system made by relay and solenoid valve are tested. The results proved the universality and reliability of the testing system so that these relays and solenoid valves could be accurately used in the antithrombotic pressure circulatory equipment. The newly-developed testing system has a bright future in the aspects of promotion and application prospect.
Equipment Design
;
Humans
;
Monitoring, Ambulatory
;
instrumentation
;
Pressure
;
Reproducibility of Results
;
Software
;
Thrombosis
;
diagnosis
5.Design of Military Certificated Doctors Management System Based on No.1 Military Medical Porject
Kun PENG ; Xiaoxiang LIU ; Yao ZHANG ; Jiansong SHANG
Chinese Medical Equipment Journal 1989;0(04):-
Objective To manage the information of examination, certification and registration of doctors in the organizations of medical treatment, prevention and health care. Methods A software was developed by using the client/server model and object-oriented technique on the basis of experiences from many years of hard working in military hospital. Results Because of the successful design and application of the software, the whole military certificated doctors information database was established for trends tracking management of all military certificated doctors' information by general departments. Conclusion The database management and developing technique are the same as those of No.1 Military Medical System. It is very practical.
6.Changes and significance of aquaporin 4 expression in mice models of fat embolism syndrome
Xi LIU ; Jiawei SHANG ; Kun TIAN ; Aizhong WANG
Chinese Journal of Trauma 2014;30(8):848-852
Objective To investigate the role of aquaporin 4 (AQP4) in partial pathologic process of lung injury in rat models of fat embolism syndrome (FES).Methods A total of 120 healthy male C57BL/6J mice were assigned to control group and FES group which was subgrouped at 4,6,12,24,and 48 hours with 20 mice per group,according to the random number table.Allogeneic perinephric fat was injected to rat caudal veins in FES groups.Lung samples were harvested from each group to examine pathological morphology and lung weight to dry ratio (W/D) to verify the FES models and observe the pathologic process.Expression of AQP4 was detected by western blot and immunohistochemistry.Additional 36 C57BL/6J mice were divided into control group,DMSO group,FES 12-hour group,and AQP4 inhibitor group according to the random number table,with 9 mice per group.Pathologic process of FES-induced lung injury was detected after the inhibition of AQP4.Results Damage to lung tissues was notable in FES group compared with control group.Lung W/D value was 5.06 ± 1.23,5.22 ± 1.58,6.18 ± 1.65,and 5.07 ± 0.31 at 6,12,24,and 48 hours respectively,which was higher than 3.16 ± 1.58 in control group (F =3.62,P < 0.05).Expression of AQP4 was 1.71 ± 1.05 at 12 hours and 1.28 ± 0.68 at 24 hours in FES group,which showed significantly increase when compared with 0.65 ±0.08 in control group (F =4.12,P <0.01),whereas at 4 hours (0.76 ± 0.36),6 hours (1.17 ± 0.60),and 48 hours (0.85 ±0.45) in FES group,no statistical difference was observed when compared to control group.W/D value in FES 12-hour group (5.22 ± 1.17),DMSO group (4.96 ±1.66),and AQP4 inhibitor group (3.25 ± 1.19) was higher than 3.03 ± 1.68 in control group (F =3.69,P < 0.05).Meanwhile,there was no statistical difference between DMSO and FES 12-hour groups,but significantly lowered W/D value was observed in AQP4 inhibitor group than in FES 12-hour group.Conclusion AQP4 may be implicated in mitigating lung injury induced by FES.
8.The pathological findings and inflammatory responses in the lung tissue of neonatal rats following lipopolysaccharide treatment.
Xu-xu CAI ; Yue DU ; Xiao-hua HAN ; Yun-xiao SHANG ; Yu-kun HAN
Chinese Journal of Pediatrics 2003;41(8):617-618
Animals
;
Animals, Newborn
;
Bronchoalveolar Lavage Fluid
;
chemistry
;
cytology
;
Female
;
Lipopolysaccharides
;
toxicity
;
Lung
;
drug effects
;
enzymology
;
pathology
;
Male
;
Neutrophils
;
cytology
;
Peroxidase
;
analysis
;
Rats
;
Rats, Wistar
9.Screening of Pim kinase inhibitors by the establishment of high-throughput ELISA system
Kun SHANG ; Peng ZHANG ; Lu ZHOU ; Zhen WANG ; Yue CAO ; Yingyi LI
China Oncology 2013;(4):260-266
10.3969/j.issn.1007-3969.2013.04.004
10.Effects of gender on incidence of intraventricular hemorrhage in very low and extremely low birth weight infants
Si CHEN ; Su LIN ; Hao ZHANG ; Qingqing JIE ; Kun SHANG ; Li WANG ; Zhenlang LIN
Chinese Journal of Perinatal Medicine 2014;17(5):317-322
Objective To examine the relationship between gender and intraventricular hemorrhage (IVH) in very low birth weight infants (VLBWI) and extremely low birth weight infants (ELBWI).Methods From January 1,1999 to December 31,2012,data on VLBWI and ELBWI,who were admitted to the neonatal intensive care unit of Yuying Children's Hospital within 14 d after birth,were retrospectively collected.The Chi-square test and t test were used to compare neonatal outcomes between male and female infants.The Logistic model was used to analyze the risk factors for IVH.Results A total of 1 008 cases were enrolled,including 615 males and 393 females,895 VLBWI and 113 ELBWI.The incidence of IVH was 15.1% (152/1 008) and the incidence of severe IVH was 8.4% (85/1 008).Compared with females,males had a higher total incidence of IVH [17.2% (106/615) vs 11.7% (46/393),x2=5.728,P<0.05] and severe IVH [9.8% (60/615) vs 6.4% (25/393),x2=3.896,P<0.05].These differences were also seen in VLBWI with a birth weight of 1 250 to 1 499 g [IVH:13.7% (47/344) vs 7.8% (17/217),x2=4.473,P=0.034; severe IVH:7.6% (26/344) vs 2.8% (6/217),x2=5.684,P=0.017].Logistic regression analysis showed that the risk factors for IVH were as follows:gestational age <28 weeks (aOR=2.012,95%CI:1.288-3.143,P<0.05),neonatal respiratory distress syndrome (aOR=l.584,95%CI:1.007-2.492,P<0.05),invasive mechanical ventilation (aOR=2.743,95%CI:1.826-4.121,P<0.05),electrolyte disturbance (aOR=2.128,95%CI:1.092-4.149,P<0.05) and periventricular leukomalacia (aOR=2.901,95%CI:1.312-6.416,P<0.05),but not male sex (aOR=1.351,95%CI:0.917-1.991,P=0.128).The risk factors for severe IVH were gestational age <28 weeks (aOR=2.200,95%CI:1.305-3.708,P<0.05),invasive mechanical ventilation (aOR=4.714,95%CI:2.809-7.911,P<0.05) and electrolyte disturbance (aOR=2.232,95%CI:1.047 4.759,P<0.05),but not male sex (aOR=1.361,95%CI:0.823 2.252,P=0.247).Conclusions Male VLBWI and ELBWI have a higher incidence of IVH and severe IVH,but male sex is not a risk factor for IVH or severe IVH.