1.Design of a testing system for antithrombotic pressure circulatory equipment.
Xun ZHOU ; Haipo CUI ; Kun SHANG ; Zhelong LI ; Enqing CHENG
Journal of Biomedical Engineering 2014;31(1):192-195
A new type of testing system used for antithrombotic pressure circulatory equipment has been developed, which realized a new method for the calibration of pressure sensor. Multi-path control and acquisition functions are achieved by this method based on human-computer interaction testing system. The precision of pressure sensor is ob tained by polynomial fitting for each test point using linear interpolation method. The result showed that the precision test of pressure sensor could be realized easily and efficiently, using the developed testing system, and the parameters of pressure sensor could be calibrated effectively, so that it could be accurately used in the antithrombotic pressure circulatory equipment. The developed testing system has a prosperous future in the aspects of promotion and application.
Algorithms
;
Calibration
;
Equipment Design
;
Humans
;
Monitoring, Physiologic
;
instrumentation
;
Pressure
;
Thrombosis
;
diagnosis
2.Examination of binocular disparity information of normal vision children
Juanjuan CHENG ; Guohong ZHAO ; Wei LU ; Li YAN ; Kun LUO
Chinese Journal of General Practitioners 2014;13(11):938-939
To explore the binocular disparity information for children with a normal vision based on computer-assisted evaluation system.We examined the random dot zero-order disparity,line zero-order disparity,2nd-order disparity and random dot motion parallax for 97 children with normal vision.And 94 children reached 100″ vision disparity both in random dot zero-order disparity and line zero-order disparity (pass rate of 96.9%) ; all 94 cases passed the 2nd-order disparity and random dot motion parallax.Thus children with a normal vision develop their stereopsis.
3.Baseline survey and discussions for clinical engineering departments of Zhejiang province
Kun ZHENG ; Cheng YU ; Yan LI ; Long CHEN
Chinese Journal of Hospital Administration 2012;28(1):44-46
The survey aims at probing into the current development of medical instruments in hospitals and computerized quality control,upgrading the competence of hospital engineering departments and guiding the development of medical clinical engineering.Questionnaire surveys were made to the medical engineering departments of 195 hospitals above secondary hospitals in Zhejiang,totaling 1001 professionals.The results indicate significant differences among hospitals of various scales in terms of deployment of medical engineering Professionals,working conditions,and computerized applications,yet a consistency in academic title promotion and training requirements.In this consideration,it is imperative to build the team,maintain consistency in professional certification of medical engineering professionals,build a regular and systematic examination,promotion and certification system,enhance training in professional knowledge and equipment quality control,as well as promoting information and resources sharing.All these efforts are essential for better quality control and management of medical engineering departments,and promoting computerized management of medical instruments.
4.Value of ADAM12-S in early diagnosis of ectopic pregnancy of pregnant women
Jinmei CHENG ; Xiangxue TIAN ; Yonghong RAO ; Kun LI
Chinese Journal of Biochemical Pharmaceutics 2014;37(7):161-163,166
Objective To determine the values and variation tendency of a disintegrin and metalloprotease 12-S(ADAM12-S)of early pregnancy, and discuss the value of ADAM12-S to the ectopic pregnancy in the first trimester.Methods 150 early pregnancy cases (from the 5th to 10th week of pregnancy)were selected in Huanggang Women &Children's Healthcare Hospital.There were 102 cases of normal pregnancy,48 cases of ectopic pregnancy.The AutoDELFIA immunoassay platform was used to measure the value of ADAM12-S in the serum.Results Of the 102 normal pregnancies, the values of ADAM12-S in 5th-10th week of pregnancy linearly increase with gestationalage.The correlation coefficient was 0.9217 (P<0.05).While the values of ADAM12-S in the ectopic pregnancy group were significantly lower than the normal pregnancy group and not linearly increased with gestationalage.The correlation coefficient was 0.2817.There was statistically significant difference between the two groups (P<0.05).Conclusion The values of ADAM12-S is stable in the first trimester of normal pregnancy,while it is much more lower in abnormal pregnancy.ADAM12-S has great significance in the diagnosis of ectopic pregnancy of the first trimester.
5.Correlation of Platelet-Activating Factor Acetylhydrolas Gene Polymorphism and Bronchial Asthma in Children
hai-lin, LI ; fei, CHENG ; yong-kun, HUANG
Journal of Applied Clinical Pediatrics 2006;0(20):-
0.05).Conclusion PAF-AH-Ala379Val gene mutation is unrelated to bronchial asthma in children.
6.Cloning and Expression of a Bradyzoite-Specific Gene of Toxoplasma gondii and Immunoreactive Analysis on the Recombinant Antigen
Qiong WANG ; Kun WU ; Xiaoguang CHEN ; Li HAO ; Lu CHENG
Chinese Journal of Parasitology and Parasitic Diseases 1987;0(04):-
Objective To clone and express bradyzoite antigen 1(BAG1) gene of T. gondii,and analyze the immunoreactivity of the recombinant product. Methods The differentiation of T. gondii RH strain tachyzoites into bradyzoites was induced in vitro,and the coding sequence of BAG1 was amplified from bradyzoites by RT-PCR. The PCR product was analyzed by sequencing. The BAG1 coding sequence was further subcloned into the plasmid pET32a(+). The plasmid pET32a(+)-BAG1 was then transformed into BL21(DE3) to express after IPTG induction. The expression product was purified with Ni-NTA agarose and the purified BAG1 was further analyzed by Western blotting and ELISA. Results BAG1 cDNA was amplified from bradyzoites. After IPTG induction,BAG1 was expressed in a fusional form in E. coli. Western blotting showed that the purified recombinant protein could be specifically recognized by sera from mice chronically infected by T. gondii B36 strain. ELISA showed that the positive rate of T. gondii IgG antibodies of 350 human sera detected by the recombinant BAG1(17.4%) was higher than by recombinant SAG1 (12.6%)(P
7.The establishment of an arterialized liver transplantation model in mice
Yujun ZHANG ; Geng CHEN ; Xiaowu LI ; Cheng YANG ; Shuguang WANG ; Ping BIE ; Kun LI ; Jiahong DONG
Chinese Journal of General Surgery 2008;23(7):503-506
Objective To establish a stable orthotopic liver transplantation(OLT)model with hepatic artery reconstruction in mice.Methods Of the 66 OLT mice,33 recipient mice underwent conventional 'two cuff' technique without hepatic artery reconstruction(control group),33 with hepatic artery reconstruction using 'stent' technology(experimental group).Results The 2 week posttransplant survival rate was 84.85%(28/33)and 81.82%(27/33)in the arterialized and nonarterialized groups respectively.Serum γ-GT and ALP level of arterialized recipient were much lower than those of nonarterialized animals.The pathology of the donor liver showed that rearterialization helps to relieve bile duct injury of liver allograft.Conclusions The hepatic artery supply plays a central role in preventing bile duct injury after transplantation.This mouse OLT model may meet the need for the study of problems associated with liver transplantation.
8.Study and evaluation of preparation of silybin PLGA microspheres by stainless steel membrane emulsification technique.
Kun RONG ; Bin-Li LIU ; Mu-Zi LI ; Liang-Liang XU ; Xin YI ; Cheng-Ke CAI
China Journal of Chinese Materia Medica 2014;39(7):1229-1233
OBJECTIVEThe aim of the present study was to prepare uniform-sized silybin loaded poly (lactic-co-glycolic acid) (PLGA) microspheres in study of silybin with stainless steel membrane.
METHODSilybin PLGA microspheres were prepared by stainless steel membrane emulsification. The preparation conditions were optimized by single-factor test and orthogonal experiment, and evaluating the mean diameters, the particle size distribution, drug loading, entrapment efficiency and morphology of microsphere.
RESULTPrepared microspheres were round and surface was smooth. The mean diameter was (4.961 +/- 0.56) microm. The span was (1.75 +/- 0.18). The entrapment efficiency was (54.997 +/- 4.05)% and the average drug loading was (23.6 +/- 1.70)%.
CONCLUSIONThe stainless steel membrane emulsification can be used to prepare the silybin PLGA microspheres. The mean diameters of the silybin PLGA microspheres can be controlled in certain level. Stainless steel membrane emulsification has great potentiality exploitation and utilization.
Drug Compounding ; methods ; Emulsions ; chemistry ; Lactic Acid ; chemistry ; Microspheres ; Particle Size ; Polyglycolic Acid ; chemistry ; Silymarin ; chemistry ; Stainless Steel ; chemistry
9.Effects of ezetimibe and simvastatin on transient outward potassium current in ischemia-reperfused ventricular myocytes in rats
Kun ZHANG ; Guangping LI ; Jian LI ; Lijun CHENG ; Wansong YANG ; Yanxun CHEN
Tianjin Medical Journal 2015;(11):1296-1299
Objective To observe the impact of alone or combined use of ezetimibe and simvastatin on transient outward potassium current (Ito) in ventricular myocytes of rat model of ischemia and reperfusion (IR). Methods Seventy-five male SD rats were randomly divided into five groups, control group (CON), control-IR group (CIR), ezetimibe treatment group (EIR), simvastatin treatment group (SIR) and combined ezetimibe and simvastatin treatment group (ESIR). After two weeks of treat?ment with intragastic normal saline or drugs (ezetimibe or simvastatin), myocytes were isolated from right ventricular with colla?genaseⅡ, and Ito was recorded by whole-cell patch clamp technique. Results (1) The Ito current density at+60 mV was sig?nificantly decreased in CIR group than that of CON group (P<0.05). There was no significant difference in Ito current density between SIR group and ESIR group (P>0.05). The Ito current densities were higher in SIR group and ESIR group compared to those of CIR group. There was no significant difference in Ito current density between SIR group and ESIR group (P>0.05). (2) There was a significant increase in the half-inactivation (V1/2) in CIR group than that of CON group, but no significant differ?ence between EIR group and CIR group (P >0.05). There was a significant difference in the half-inactivation (V1/2) in SIR group and ESIR group compared to that of CIR group (P<0.05), but no significant difference between SIR group and ESIR group (P>0.05). There was no significant difference in the slope factor (K) between five groups (P>0.05). (3) The time-con?stant (τ) of Ito recovery curves from inactivation was significantly higher in CIR group than that of CON group (P<0.05), which was no significant difference between EIR group and CIR group (P>0.05). There was a significant difference in the time-con?stant (τ) of Ito recovery curves from inactivation in SIR group and ESIR group compared to that of CIR group (P<0.05), but no significant difference between SIR group and ESIR group (P>0.05). Conclusion Simvastatin pre-treatment or ezetimibe+simvastatin pre-treatment can reverse the effect of IR on Ito of ventricular myocytes, but ezetimibe shows no such effects.
10.The application of the reduced dosage of the contrast medium with saline flush in cerebral and carotid angiography with 64-slice spiral CT
Li-Zhen CAO ; Kun-Cheng LI ; Xiang-Ying DU ; Xiao-Lian ZHU ;
Chinese Journal of Radiology 2001;0(08):-
0. 05). Conclusion On the CTA exams with 64-slice spiral CT, good CTA image quality can be acquired with reduced contrast dose and saline flush, thereby we can afford reliable diagnostic information for the clinicians.