1.Estimation of Young's Modulus and Apparent Density of Human Trabecular Bone by Spherical Indentatin Test and CT.
Tae Soo BAE ; Tae Soo LEE ; Seung Baik KANG ; Young Min KIM ; Kui Won CHOI
Journal of Korean Orthopaedic Research Society 1999;2(2):155-163
We intended to evaluate the Young's modulus of trabecular bone and apparent density from Computed Tomography(CT) and Spherical Indentation test and to quantify relation ship between them. The distal femurs(31 age, male, left and right) were prepared for exprimentatin and were embedded with repect to anatomical orientation. Then the specimens were scnned at 1 mm intervals on GE9800 CT scanner and the Hounsfield Units(HU, or CT number) were extracted from each CT image. After scanning, the bones were sectioned with diamond saw, producing 8 mm cubes of trabecular bone(72 eachs) from the metaphyseal region of both distal femur. The cubes were mechanically tested in inferior-superior(IS), anteriorposterior(AP), and medial-lateral(ML) direction with custom-made device, Spherical Indentatin Tester. After testing, the real apparent density of specimens were measured. The results of this study showed that the IS modulus was singificantly greater than both the AP and ML modulus and the AP modulus was also greater than ML modulus significantly(p<0.01). A linear relation ship between HU and real apparent density was found to be significant(R2=0.68) and significant power relationship between the apparent density and the tangent moduli(either by CT or physical measures) was also found.
Diamond
;
Elastic Modulus*
;
Femur
;
Humans*
;
Male
;
Ships
2.Development of Spine Motion Analyzer and Comparison of Motion in Normal and Lumbar Fusion Cases.
Bong Soon CHANG ; Young Eun KIM ; Jin Sup YEOM ; Kui Won CHOI ; Choon Ki LEE
The Journal of the Korean Orthopaedic Association 1997;32(2):359-369
Many kinds of lumbar diseases cause lumbar segmental instability and/or limitation of motion. But, there is no reliable method for measuring accurate trunk motion. In order to measure relative trunk motion respect to the pelvis in vitro, external linkage type of spine motion analyzer was developed. Special programs for calculation of the relative angular motion and graphical display were also developed. The developed device was tested to compare spine motion pattern between 15 normal volunteers and 18 lumbar fusion patients in flexion, extension, lateral bending and axial rotation. It was rather simple and reliable method for spine motion analysis. And it was possible to measure not only angular displacement but also angular velocity and angular acceleration. There were more coupling motions in lateral bending and axial rotation than in flexion and extension. Compared to the normal subjects, patients showed different angular motion, especially in the angular acceleration. Optimal trajectory of the trunk motion derived from mathematical model in flexion and extension matched well with measurement for normal subjects.
Acceleration
;
Healthy Volunteers
;
Humans
;
Models, Theoretical
;
Pelvis
;
Spine*
3.Wear Properties of Surface Modified Ultra-high Molecular Weight Polyethylene.
Kyung Tae KIM ; Jae Bong CHOI ; Kui Won CHOI
Journal of Korean Orthopaedic Research Society 1998;1(2):167-173
The wear debris of ultra-high molecular weight polyethylene (UHMWPE) used as a bearing material in total joint arthroplasty evokes a serious adverse biological reaction (osteolysis). In this study, therefore, the wear resistance of UHMWPE is enhanced by attaching a hydrophilic graft on the UHMWPE surface and by improving surface hardness without deteriorating the mechanical properties, which may result in the formation of lubrication film and the increased resistance to penetration, scratching or deformation during articulation. This was done by ion-implantation technique. The results showed that the wettability and the surface hardness of the modified UHMWPE by the above treatments increased due to the increased cross-linking density and hydrophilic graft attachment on the surface. The wear test was performed by a wear testing machine of pin-on-disk type. The modified UHMWPE revealed about 30~50% less volumetric wear than the control specimen. It was also shown that the volumetric wear depended not only on the optimal treatment condition but on the applied load and the sliding speed.
Arthroplasty
;
Hardness
;
Joints
;
Lubrication
;
Molecular Weight*
;
Osteolysis
;
Polyethylene*
;
Transplants
;
Wettability
4.Improved stress analyses of dental systems implant by homogenization technique.
Chul Su KOH ; Man Sup LEE ; Kui Won CHOI
The Journal of the Korean Academy of Periodontology 1997;27(1):263-290
Homogenization technique is employed to investigate the series of stress analyses of mandible for three different types of dental implants. This technique helps to make proper material model of bone and analyze such a non homogeneous structure at the level of individual microstructural unit. The stress analyses with homogenization technique show much higher stress level in the sponge bone, compared to those of conventional FEM. It also manifested that even a minor lateral force results in crucial stresses in the dental implant system and that the macroscale model should take the shape and size after real mandible to produce reasonable solution in the analyses of dental implant systems. The shapes of dental implants simulated in this study are rectangularcross-sectioned type, hemi-sphere rooted type, and wedge type implant. The stress states of mandible with hemisphere rooted type implant and wedge type implant show similar levels, while those with sectioned rectangular implant results in higher stresses. It is suggested that the distance between the implant tip and cortical bone be kept far enough to prevent stress concentrations in the mandible.
Dental Implants
;
Mandible
;
Porifera
5.Transplantation of Cultured Allogenic Chondrocyte-Collagen Gel Composite into the Articular Cartilage Defect of Rats.
In Ho SEONG ; Sang Cheol SEONG ; Myung Chul LEE ; Hyun Cheol OH ; Kye Yong SONG ; Kui Won CHOI
Journal of Korean Orthopaedic Research Society 1999;2(2):87-101
As one of many cell-many cell-based cartilage repairing methods, transplantation of chondrocyte-embedded-collagen gels in cartilage defect was performed for more satisfactory regeneration of cartilage. The authors performed this study to investigate whether the TGF-beta1 treatment of chondrocytes can do some additional synergistic effect on the transplantation of chondrocyte-embedded-collagen gels for crtilage repair. Chondrocytes were isolated from the articular cartilage of newborn Sprague-Dawley rats. Chondrocytes cultured for 10 days in monolayer were embedded in the 0.45% type I collagen gel. Full-thickness cartilage defect was made in the patellar groove of adult Sprague-Dawley rats. Chondrocytes culdefect was made in the patellar groove of adult Sprague-Dawley rats. The cartilage defects were treated with the following methods in a total of 200 animals, which were assigned to 5 different groups of 40 rats. In the control group, the deffect was left without any treatment, in group I, the defect was filled with collagen gel only, in group II, with collagen gel coontaining 10 ng/ml concentration of TGF-beta1, in group III, with collagen gel containing chondrocytes, and in group IV, with collagen gel containing chondrocytes and TGF-beta1. At 1, 2, 4, 8, 12 weeks after the operation, eight rats of each group were sacrificed, and their distal femurs were harvested for the histologic and biomechanical tests. The section s were stained with hematoxilin and eosin. Alcian-blue, and Safranin-O. Regenerated cartilage was analyzed by the semiquantitative histological grading system. Point indentation test was performed as a biomechanical evaluation, and the stiffness was calculated. The results of the histological grading system revealed that the scores gradually increased with time in all groups, and the scores of group III and IV were higher than those of control, group I and II. The biomechanical study showed that the stiffness gradually increased to reach a plateau level in each group. In control, group I and II, the stiffness increased up to the eighth week and remained around the increased level at the twelfth week, and did not show any statistically significant difference between the groups. In group III and IV, the stiffness was higher than in control group, and increased markedly at the fourth week and the increased level was maintained onwards. The results of this study showed that the transplantation of chondrocyte-embedded-collagen gels enhanced the healing process, and the treatment of TGF-beta1 demonstrated at least partially significant improvement.
Adult
;
Animals
;
Cartilage
;
Cartilage, Articular*
;
Chondrocytes
;
Collagen
;
Collagen Type I
;
Eosine Yellowish-(YS)
;
Femur
;
Gels
;
Humans
;
Infant, Newborn
;
Rats*
;
Rats, Sprague-Dawley
;
Regeneration
;
Transforming Growth Factor beta1
6.The Effect of the Cross-pins on the Fixation Stiffness using Finite Element Method in Fracture of Femoral Shaft.
Moon Kyu LEE ; Jung Kyu KIM ; Kui Won CHOI ; In Ho CHOI ; Gon KHANG
Journal of Korean Orthopaedic Research Society 2002;5(1):26-33
PURPOSE: A compression plate fixation was generally used in the fracture of a femoral diaphysis but it produced the stress shielding problem which resulted in a decrease of bone mass and impaired mechanical properties. This study was designed to compare with the stiffnesses of three different internal fixation types ; fixation with only plate, with only cross-pins, and with both a plate and cross-pins. MATERIALS AND METHODS: To compare the stress distribution and stiffness of three types of fixation devices, the device-bone system are analyzed under axial compression(70Kg) and 3-point bending(500Nmm) in planes using the 2-D finite element method(ABAQUS 5.8). Also the stiffness of each device was evaluated at seven different time points during fracture healing by increasing Young's modulus of callus. RESULTS: The plate fixation model had the highest stress distribution and occurred the stress concentration in the cortex beneath the plate. During the healing of bone fracture, the fixation with cross-pins relatively had a higher compression and bending stiffness. The fixation with only cross-pins was as stiff as that with an only plate in bending but less stiff than in compression. CONCLUSION: The internal fixation added to cross-pins may decrease the stress shielding problems due to dispersing the stress concentration and also improve the stiffness of a device-bone system.
Bony Callus
;
Diaphyses
;
Elastic Modulus
;
Finite Element Analysis
;
Fracture Healing
;
Fractures, Bone
7.The Effect of Cyclic Compressive Strain on the Differentiation of Osteoblast-Like Cells (MC3T3-E1) in 3-D Scaffold.
Jung Kyu KIM ; Tae Soo LEE ; Eun Hee BAE ; Yang Sook PARK ; Kui Won CHOI
Journal of Korean Orthopaedic Research Society 2002;5(1):69-75
We examined the effect of an applied cyclic compressive strain on the growth and differentiation of MC3T3-E1 cultured in a three-dimensional chitosan scaffold. The specially designed testing apparatus for mechanical stimulus was developed for uniaxial cyclic compressive strain. Cyclic compressive strain was applied over a period of 17 days with 150 cycles per day at a frequency of 0.5hz. Strain magnitude was 2.5% of the scaffold length. Control group and mechanically stimulated group were incubated and harvested at the indicated times. (day 3, 7, 10, 14, 17) The total amount of protein and alkaline phosphatase activity were examined. The total amount of protein of the control group was higher than that of the mechanically stimulated group. This was due to cell death for the nodule formation and calcium deposit of the mechanical stimuli group which resulted in cell differentiation. The alkaline phosphatase activity increased slightly in the control group. However, in the mechanical stimuli group, it increased significantly and reached its peak level on day 7 and subsequently its activity dropped to a level that was higher than the level at day 4(p < 0.05). Conclusively, it can be noted that the mechanical stimulus significantly accelerated the differentiation of MC3T3-E1 cells.
Alkaline Phosphatase
;
Calcium
;
Cell Death
;
Cell Differentiation
;
Chitosan
8.Biomechanical Analysis of Unilateral-Ring Hybrid External Fixation.
In Ho CHOI ; Kui Won CHOI ; Ki Seok LEE ; Chin Youb CHUNG ; Tae Joon CHO ; Duk Yong LEE
Journal of Korean Orthopaedic Research Society 1998;1(2):135-144
The mechanical stiffness of Unilateral-Ring Hybrid External Fixation(URHEF) was analyzed and compared with conventional Ilizarov circular external fixation system and unilateral fixation with DynaExtor(R). Our URHEF is basically a unilateral external fixation system which affords easier incorporation and removal of the Ilizarov rings(200mm in diameter) coupled with connecting clamps at anytime, if needed. It allows controlled axial micromotion in due time. For mechanical test, URHEF system was constructed using a DynaExtor(R) fixed with two or three half pins(6 mm in diameter) attached with two proximal and distal Ilizarov rings fixed with an olive pin and a half pin on each ring. Unilateral fixation system was constructed with a DynaExtor(R) fixed with 2 or 3 half pins. Ring fixation system was constructed with four Ilizarov rings(140mm in diameter). Ilizarov system were assembled into 90degrees-90degrees and 45degrees-13 5degrees configurations with 2 olive pins, respectively. The distance between the center of pylon and the pin-clamp interface was equalized, being 70mm, in all the systems. Stiffness in axial compression, anteroposterior and lateral bending was measured. On axial compression and lateral bending tests, URHEF was stiffer than DynaExtor(R) and Ilizarov systems. On anteroposterior bending test, URHEF was less stiff than 90degrees-50degrees configuration of the Ilizarov system but stiffer than 45degrees-135degrees configuration. Considering the fact that instead of 90degrees-90degrees transfixing pin fixatin system, 45degrees-135degrees configuration system is generally used in clinical practice, URHEF appears to be significantly stiffer than unilateral(DynaExtor(R)) and circular (Ilizarov)fixation systems. This mechanical study implicates that URHEF can be beneficially applied in the clinical use with assurance of mechanical stability.
External Fixators
;
Olea
9.Estimating Age-Specific Mean Sojourn Time of Breast Cancer and Sensitivity of Mammographic Screening by Breast Density among Korean Women
Eunji CHOI ; Mina SUH ; So-Youn JUNG ; Kyu-Won JUNG ; Sohee PARK ; Jae Kwan JUN ; Kui Son CHOI
Cancer Research and Treatment 2023;55(1):136-144
Purpose:
High breast cancer incidence and dense breast prevalence among women in forties are specific to Asian. This study examined the natural history of breast cancer among Korean women.
Materials and Methods:
We applied a three-state Markov model (i.e., healthy, preclinical, and clinical state) to fit the natural history of breast cancer to data in the Korean National Cancer Screening Program. Breast cancer was ascertained by linkage to the Korean Central Cancer Registry. Disease-progression rates (i.e., transition rates between three states), mean sojourn time (MST) and mammographic sensitivity were estimated across 10-year age groups and levels of breast density determined by the Breast Imaging, Reporting and Data System.
Results:
Overall prevalence of dense breast was 53.9%. Transition rate from healthy to preclinical state, indicating the preclinical incidence of breast cancer, was higher among women in forties (0.0019; 95% confidence interval [CI], 0.0017 to 0.0021) and fifties (0.0020; 95% CI, 0.0017 to 0.0022), than women in sixties (0.0014; 95% CI, 0.0012 to 0.0017). The MSTs, in which the tumor is asymptomatic but detectable by screening, were also fastest among younger age groups, estimated as 1.98 years (95% CI, 1.67 to 2.33), 2.49 years (95% CI, 1.92 to 3.22), and 3.07 years (95% CI, 2.11 to 4.46) for women in forties, fifties, and sixties, respectively. Having dense breasts increased the likelihood of the preclinical cancer risk (1.96 to 2.35 times) and decreased the duration of MST (1.53 to 2.02 times).
Conclusion
This study estimated Korean-specific natural history parameters of breast cancer that would be utilized for establishing optimal screening strategies in countries with higher dense breast prevalence.
10.Influence of metabolic and other clinicopathologic factors on the prognosis of patients with hepatocellular carcinoma undergoing hepatic resection.
Kui Sun CHOI ; Dong Sik KIM ; Sung Won JUNG ; Young Dong YU ; Sung Ock SUH
Korean Journal of Hepato-Biliary-Pancreatic Surgery 2014;18(4):105-111
BACKGROUNDS/AIMS: The prognosis of hepatic resection for hepatocellular carcinoma (HCC) in patients with cirrhosis is worse than in those without cirrhosis. In Korea, the hepatitis B virus prevalence rate is higher than in other countries. Therefore, we investigated patients' clinicopathologic and metabolic factors that affect the postoperative outcomes of hepatic resection for HCC in our hospital in Korea. METHODS: From August 2000 to December 2012, 171 HCC patients underwent hepatic resections at our institution. Two operative mortality cases and two short-term follow up cases were excluded. Data was collected from a retrospective chart review. There were 133 males (79.6%) and 34 females (20.3%), with a mean age of 58.2+/-10.2 years (range, 22-81 years), and the relationship between clinicopathologic and metabolic factors and the prognosis of patients with HCC undergoing hepatic resection were evaluated by univariate and multivariate analysis. RESULTS: Hypertension, major surgery, perioperative transfusion, resection with radiofrequency ablation (RFA) or cryoablation, and resection margin were risk factors for overall survival, and hypertension, albumin, resection with RFA or cryoablation, perioperative transfusion, and tumor size were risk factors for disease-free survival. CONCLUSIONS: We found that hypertension, perioperative transfusion, and resection with RFA or cryoablation were risk factors for both disease-free and overall survival after hepatic resection in HCC patients. Further study is required to clarify the influence of metabolic and other clinicopathologic factors on the prognosis of HCC.
Carcinoma, Hepatocellular*
;
Catheter Ablation
;
Cryosurgery
;
Disease-Free Survival
;
Female
;
Fibrosis
;
Follow-Up Studies
;
Hepatitis B virus
;
Humans
;
Hypertension
;
Korea
;
Male
;
Mortality
;
Multivariate Analysis
;
Prevalence
;
Prognosis*
;
Retrospective Studies
;
Risk Factors