1.Assessment of thickness of in vivo autograft tendons around the knee and its correlation with anthropometric data, thickness of patella and anterior cruciate ligament tibial foot print diameter
Balgovind S RAJA ; Kshitij GUPTA ; Abdusamad V ; Sukhmin SINGH ; Subhajit MAJI
Anatomy & Cell Biology 2021;54(1):18-24
Inadequate diameters of the autograft tendons are known to be a major cause of graft failure in ligament reconstruction. The purpose of the study was to measure the in-vivo thickness of the available autograft options around the knee and to seek a correlation between the thickness of the tendons and the anthropometric data, patellar thickness and anterior cruciate ligament (ACL) footprint sagittal diameter. Magnetic resonance imaging of 104 consecutive patients with suspected knee injuries were utilized for measurement of the in vivo thickness of pes anserinus tendon (diameter and cross-sectional area [CSA]), patellar tendon (PT) and quadriceps tendon (QT). Pearson’s coefficient was used to find out the relationship between the tendon thickness and anthropometric data, thickness of patella and ACL tibial foot print sagittal diameter. The mean diameters and CSA of the semitendinosus tendon (ST) and gracilis tendon (GT) were 3.77±0.49 mm, 11.62±1.62 mm2 and 2.87±0.27 mm, 6.64±1.18 mm2 respectively. QT and PT thicknesses were 7.36±0.87 mm and 4.50±0.62 mm respectively. Height and the patellar thickness were seen to have moderate correlation with ST and PT thickness. Weak correlation was seen between the other anthropometric variables and tendon thickness. Magnetic resonance imaging (MRI) assessment of tendon sizes is a reliable method with good inter and intra-rater agreement. Assessment of these anatomical structures with help of MRI would be helpful in preoperative planning and can help in identifying those patients at risk of having smaller tendons.
2.Assessment of thickness of in vivo autograft tendons around the knee and its correlation with anthropometric data, thickness of patella and anterior cruciate ligament tibial foot print diameter
Balgovind S RAJA ; Kshitij GUPTA ; Abdusamad V ; Sukhmin SINGH ; Subhajit MAJI
Anatomy & Cell Biology 2021;54(1):18-24
Inadequate diameters of the autograft tendons are known to be a major cause of graft failure in ligament reconstruction. The purpose of the study was to measure the in-vivo thickness of the available autograft options around the knee and to seek a correlation between the thickness of the tendons and the anthropometric data, patellar thickness and anterior cruciate ligament (ACL) footprint sagittal diameter. Magnetic resonance imaging of 104 consecutive patients with suspected knee injuries were utilized for measurement of the in vivo thickness of pes anserinus tendon (diameter and cross-sectional area [CSA]), patellar tendon (PT) and quadriceps tendon (QT). Pearson’s coefficient was used to find out the relationship between the tendon thickness and anthropometric data, thickness of patella and ACL tibial foot print sagittal diameter. The mean diameters and CSA of the semitendinosus tendon (ST) and gracilis tendon (GT) were 3.77±0.49 mm, 11.62±1.62 mm2 and 2.87±0.27 mm, 6.64±1.18 mm2 respectively. QT and PT thicknesses were 7.36±0.87 mm and 4.50±0.62 mm respectively. Height and the patellar thickness were seen to have moderate correlation with ST and PT thickness. Weak correlation was seen between the other anthropometric variables and tendon thickness. Magnetic resonance imaging (MRI) assessment of tendon sizes is a reliable method with good inter and intra-rater agreement. Assessment of these anatomical structures with help of MRI would be helpful in preoperative planning and can help in identifying those patients at risk of having smaller tendons.
3.Total Hip Arthroplasty in Protrusio Acetabuli: A Systematic Review
Sajid ANSARI ; Kshitij GUPTA ; Tushar GUPTA ; Balgovind S. RAJA ; Pranav J. ; Roop Bhushan KALIA
Hip & Pelvis 2024;36(1):12-25
Protrusio acetabuli, or abnormal protrusion of the femoral head into the acetabulum, requires performance of a total hip arthroplasty (THA) for which various reconstruction techniques and outcomes have been described. The aim of this systematic review is to provide a comprehensive analysis of the current evidence, evaluate treatment efficacy, compare surgical techniques, and identify topics for future research along with improving evidence-based decision-making, improving patient outcomes in the management of this condition. A thorough systematic review of the PubMed, Embase, Cochrane Library databases, and Scopus library was conducted, and articles describing techniques of THA for treatment of protrusion acetabuli were extracted. The initial search generated 751 results. After exclusion, 18 articles were included. Of these, eight were prospective studies and 10 were retrospective. Surgery was performed on 783 hips with a mean age of 60 years; 80% of females who mostly had inflammatory arthritis were followed up for 8.86 years (range, 2-15.4 years). Good outcomes have been achieved with THA using uncemented cups with bone graft; however, no conclusion could be drawn with regard to the femoral side. It can be concluded that the concept of restoration of the anatomical hip center of rotation is paramount for good outcome and better survival of the implant is important when using uncemented cups with a bone graft. In addition, screw augmentation for fixation is not recommended unless absolutely necessary. The most common complications were aseptic loosening and heterotopic ossification. While the former required revision, conservative management was administered for the latter.
4.Total Hip Arthroplasty in Protrusio Acetabuli: A Systematic Review
Sajid ANSARI ; Kshitij GUPTA ; Tushar GUPTA ; Balgovind S. RAJA ; Pranav J. ; Roop Bhushan KALIA
Hip & Pelvis 2024;36(1):12-25
Protrusio acetabuli, or abnormal protrusion of the femoral head into the acetabulum, requires performance of a total hip arthroplasty (THA) for which various reconstruction techniques and outcomes have been described. The aim of this systematic review is to provide a comprehensive analysis of the current evidence, evaluate treatment efficacy, compare surgical techniques, and identify topics for future research along with improving evidence-based decision-making, improving patient outcomes in the management of this condition. A thorough systematic review of the PubMed, Embase, Cochrane Library databases, and Scopus library was conducted, and articles describing techniques of THA for treatment of protrusion acetabuli were extracted. The initial search generated 751 results. After exclusion, 18 articles were included. Of these, eight were prospective studies and 10 were retrospective. Surgery was performed on 783 hips with a mean age of 60 years; 80% of females who mostly had inflammatory arthritis were followed up for 8.86 years (range, 2-15.4 years). Good outcomes have been achieved with THA using uncemented cups with bone graft; however, no conclusion could be drawn with regard to the femoral side. It can be concluded that the concept of restoration of the anatomical hip center of rotation is paramount for good outcome and better survival of the implant is important when using uncemented cups with a bone graft. In addition, screw augmentation for fixation is not recommended unless absolutely necessary. The most common complications were aseptic loosening and heterotopic ossification. While the former required revision, conservative management was administered for the latter.
5.Total Hip Arthroplasty in Protrusio Acetabuli: A Systematic Review
Sajid ANSARI ; Kshitij GUPTA ; Tushar GUPTA ; Balgovind S. RAJA ; Pranav J. ; Roop Bhushan KALIA
Hip & Pelvis 2024;36(1):12-25
Protrusio acetabuli, or abnormal protrusion of the femoral head into the acetabulum, requires performance of a total hip arthroplasty (THA) for which various reconstruction techniques and outcomes have been described. The aim of this systematic review is to provide a comprehensive analysis of the current evidence, evaluate treatment efficacy, compare surgical techniques, and identify topics for future research along with improving evidence-based decision-making, improving patient outcomes in the management of this condition. A thorough systematic review of the PubMed, Embase, Cochrane Library databases, and Scopus library was conducted, and articles describing techniques of THA for treatment of protrusion acetabuli were extracted. The initial search generated 751 results. After exclusion, 18 articles were included. Of these, eight were prospective studies and 10 were retrospective. Surgery was performed on 783 hips with a mean age of 60 years; 80% of females who mostly had inflammatory arthritis were followed up for 8.86 years (range, 2-15.4 years). Good outcomes have been achieved with THA using uncemented cups with bone graft; however, no conclusion could be drawn with regard to the femoral side. It can be concluded that the concept of restoration of the anatomical hip center of rotation is paramount for good outcome and better survival of the implant is important when using uncemented cups with a bone graft. In addition, screw augmentation for fixation is not recommended unless absolutely necessary. The most common complications were aseptic loosening and heterotopic ossification. While the former required revision, conservative management was administered for the latter.
6.Comparative Evaluation of Several Gene Targets for Designing a Multiplex-PCR for an Early Diagnosis of Extrapulmonary Tuberculosis.
Ankush RAJ ; Netrapal SINGH ; Krishna B GUPTA ; Dhruva CHAUDHARY ; Aparna YADAV ; Anil CHAUDHARY ; Kshitij AGARWAL ; Mandira VARMA-BASIL ; Rajendra PRASAD ; Gopal K KHULLER ; Promod K MEHTA
Yonsei Medical Journal 2016;57(1):88-96
PURPOSE: Diagnosis of extrapulmonary tuberculosis (EPTB) poses serious challenges. A careful selection of appropriate gene targets is essential for designing a multiplex-polymerase chain reaction (M-PCR) assay. MATERIALS AND METHODS: We compared several gene targets of Mycobacterium tuberculosis, including IS6110, devR, and genes encoding MPB-64 (mpb64), 38kDa (pstS1), 65kDa (hsp65), 30kDa (fbpB), ESAT-6 (esat6), and CFP-10 (cfp10) proteins, using PCR assays on 105 EPTB specimens. From these data, we chose the two best gene targets to design an M-PCR. RESULTS: Among all gene targets tested, mpb64 showed the highest sensitivity (84% in confirmed cases and 77.5% in clinically suspected cases), followed by IS6110, hsp65, 38kDa, 30kDa, esat6, cfp10, and devR. We used mpb64+IS6110 for designing an M-PCR assay. Our M-PCR assay demonstrated a high sensitivity of 96% in confirmed EPTB cases and 88.75% in clinically suspected EPTB cases with a high specificity of 100%, taking clinical diagnosis as the gold standard. CONCLUSION: These M-PCR results along with the clinical findings may facilitate an early diagnosis of EPTB patients and clinical management of disease.
Bacteriological Techniques/methods
;
DNA Transposable Elements/genetics
;
DNA, Bacterial/analysis/genetics
;
Early Diagnosis
;
Female
;
Gene Amplification
;
Humans
;
Male
;
Multiplex Polymerase Chain Reaction/*methods
;
Mycobacterium tuberculosis/genetics/*isolation & purification
;
Polymerase Chain Reaction/*methods/standards
;
Sensitivity and Specificity
;
Tuberculosis/*diagnosis