1.Double-Orifice Tricuspid Valve Visualized by Three-Dimensional Transthoracic Echocardiography.
Kikuko OBASE ; Karima ADDETIA ; Kazue TAKAHASHI ; Katsunori YAMAMOTO ; Ai KAWAMURA ; Tomoko TAMADA ; Koichiro IMAI ; Shiro UEMURA
Journal of Cardiovascular Ultrasound 2016;24(3):253-255
No abstract available.
Echocardiography*
;
Echocardiography, Three-Dimensional
;
Tricuspid Valve*
2.Validity and Reliability of Seattle Angina Questionnaire Japanese Version in Patients With Coronary Artery Disease.
Satomi SEKI ; Naoko KATO ; Naomi ITO ; Koichiro KINUGAWA ; Minoru ONO ; Noboru MOTOMURA ; Atsushi YAO ; Masafumi WATANABE ; Yasushi IMAI ; Norihiko TAKEDA ; Masashi INOUE ; Masaru HATANO ; Keiko KAZUMA
Asian Nursing Research 2010;4(2):57-63
PURPOSE: The aim of this study was to evaluate the validity and reliability of the Seattle Angina Questionnaire, Japanese version (SAQ-J) as a disease-specific health outcome scale in patients with coronary artery disease. METHODS: Patients with coronary artery disease were recruited from a university hospital in Tokyo. The patients completed self-administered questionnaires, and medical information was obtained from the subjects' medical records. Face validity, concurrent validity evaluated using Short Form 36 (SF-36), known group differences, internal consistency, and test-retest reliability were statistically analyzed. RESULTS: A total of 354 patients gave informed consent, and 331 of them responded (93.5%). The concurrent validity was mostly supported by the pattern of association between SAQ-J and SF-36. The patients without chest symptoms showed significantly higher SAQ-J scores than did the patients with chest symptoms in 4 domains. Cronbach's alpha ranged from .51 to .96, meaning that internal consistency was confirmed to a certain extent. The intraclass correlation coefficient of most domains was higher than the recommended value of 0.70. The weighted kappa ranged from .24 to .57, and it was greater than .4 for 14 of the 19 items. CONCLUSIONS: The SAQ-J could be a valid and reliable disease-specific scale in some part for measuring health outcomes in patients with coronary artery disease, and requires cautious use.
Asian Continental Ancestry Group
;
Coronary Artery Disease
;
Coronary Vessels
;
Humans
;
Informed Consent
;
Medical Records
;
Reproducibility of Results
;
Thorax
;
Tokyo
;
Surveys and Questionnaires
3.Diagnosis of Myocardial Viability by Fluorodeoxyglucose Distribution at the Border Zone of a Low Uptake Region.
Eiji TOYOTA ; Teruki SONE ; Kunihiko YOSHIKAWA ; Hiroaki MIMURA ; Akihiro HAYASHIDA ; Nozomi WADA ; Kikuko OBASE ; Koichiro IMAI ; Ken SAITO ; Tomoko MAEHAMA ; Masao FUKUNAGA ; Kiyoshi YOSHIDA
Yonsei Medical Journal 2010;51(2):178-186
PURPOSE: In cardiac 2-[F-18]fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) examination, interpretation of myocardial viability in the low uptake region (LUR) has been difficult without additional perfusion imaging. We evaluated distribution patterns of FDG at the border zone of the LUR in the cardiac FDG-PET and established a novel parameter for diagnosing myocardial viability and for discriminating the LUR of normal variants. MATERIALS AND METHODS: Cardiac FDG-PET was performed in patients with a myocardial ischemic event (n = 22) and in healthy volunteers (n = 22). Whether the myocardium was not a viable myocardium (not-VM) or an ischemic but viable myocardium (isch-VM) was defined by an echocardiogram under a low dose of dobutamine infusion as the gold standard. FDG images were displayed as gray scaled-bull's eye mappings. FDG-plot profiles for LUR (= true ischemic region in the patients or normal variant region in healthy subjects) were calculated. Maximal values of FDG change at the LUR border zone (a steepness index; S(max) scale/pixel) were compared among not-VM, isch-VM, and normal myocardium. RESULTS: S(max) was significantly higher for n-VM compared to those with isch-VM or normal myocardium (ANOVA). A cut-off value of 0.30 in Smax demonstrated 100% sensitivity and 83% specificity for diagnosing n-VM and isch-VM. S(max) less than 0.23 discriminated LUR in normal myocardium from the LUR in patients with both n-VM and isch-VM with a 94% sensitivity and a 93% specificity. CONCLUSION: S(max) of the LUR in cardiac FDG-PET is a simple and useful parameter to diagnose n-VM and isch-VM, as well as to discriminate thr LUR of normal variants.
Aged
;
Aged, 80 and over
;
Echocardiography
;
Female
;
Fluorodeoxyglucose F18/*metabolism
;
Humans
;
Male
;
Middle Aged
;
Myocardial Infarction/metabolism/pathology
;
Myocardium/*metabolism/*pathology
;
Positron-Emission Tomography
;
Young Adult