2.Discrepancy between radiological and pathological sizes of renal masses.
Ji-wei HUANG ; Bai-jun DONG ; Jin ZHANG ; Wen KONG ; Wei XUE ; Dong-ming LIU ; Yi-ran HUANG
Chinese Journal of Oncology 2013;35(6):429-433
OBJECTIVETo investigate the differences between tumor sizes measured by preoperative computed tomography (CT) imaging and pathologic examination of surgical specimens in Chinese patients who received extirpative surgery for renal tumors.
METHODSFrom September 2008 to September 2010, 204 patients with renal tumors treated in the Renji Hospital were enrolled in this study, and their clinicopathological data were collected and analyzed. The paired Student's t-test was used to compare the mean radiological tumor maximum diameter and the mean pathological tumor maximum diameter. All cases in which post-operative down-staging or up-staging occurred due to the discrepancy between radiological and pathological tumor maximum diameters were identified. In addition, the relationship between radiological and pathological tumor maximum diameters and histological subtypes was analyzed.
RESULTSOverall, the radiological mean maximum diameter of tumors on CT was 48.3 mm and the pathological mean maximum diameter was 47.0 mm. On average, CT overestimated pathological size by 1.3 mm (P = 0.018). CT overestimated pathological tumor size in 111 (54.4%) patients, underestimated in 71 (34.8%) patients and equal pathological size in 22 (10.8%) patients. Among the 190 patients with pT1 or pT2 tumors, there was a discrepancy between clinical and pathological staging in 35 (18.4%) patients. Of these, 29 (15.3%) patients were down-staged post-operatively and 6 (3.2%) were up-staged. When subjects were categorized according to radiographic tumor size associated with clinical stage, statistically significant difference (average of 1.76 mm) was observed between radiographic and pathologic maximum diameters ranging 41-70 mm (P = 0.035). For clear cell carcinoma, mean radiographic tumor maximum diameter was significantly larger than the pathologic maximum diameter by 1.69 mm (P = 0.003).
CONCLUSIONSThere is a statistically significant but small difference (1.3 mm) between mean radiological and mean pathological tumor maximum diameters. For some patients, this difference leads to a discrepancy between clinical and pathological staging, which may have implications on pre-operative clinical decision and prognosis prediction.
Diagnostic Imaging ; Humans ; Kidney ; diagnostic imaging ; pathology ; Kidney Neoplasms ; diagnostic imaging ; pathology ; Prognosis ; Retrospective Studies ; Tomography, X-Ray Computed
3.Three-dimensional reconstruction of human kidney based on UroMedix-3D system and its application in kidney surgery.
Jianfeng HUANG ; Shidong LÜ ; Zhengfei HU ; Chantao HUANG ; Yiwen LI ; Qiang WEI
Journal of Southern Medical University 2019;39(5):614-620
OBJECTIVE:
To explore the feasibility of rapid and accurate three-dimensional (3D) image reconstruction using Uromedix-3D software for urological surgery.
METHODS:
The original renal thin-slice enhancement CT data were obtained from patients with kidney lesions treated in our hospital between December, 2015 and October, 2018. The self-developed Uromedix- 3D system was used to reconstruct the normal kidney structures, blood vessels, collecting systems and the lesions. The spatial anatomic relationships of the structures were measured and digitized for surgical planning.
RESULTS:
3D reconstruction of the kidneys was performed in a total of 173 cases, and the mean time for reconstruction was 31.24±2.012 min. Of these cases, 147 (84.9%) had renal tumors, and 2 had renal tumors with tumor thrombus. In addition to renal tumors, the Uromedix-3D system was also used for reconstructing other lesions including UPJO, kidney stones and retroperitoneal masses. Renal artery reconstruction was performed in 170 cases, which allowed observation of the precise terminal branches (up to 7th grade arterial branch) of the artery; 109 (64%) cases showed the 5th grade arterial branch or above. Renal artery variations were detected in 37 cases, including accessory renal artery (24 cases) and multiple renal arteries (13 cases). The renal veins were reconstructed in 164 cases, and second grade or above (up to the 4th grade) vein branches were observed in 138 (84%) cases.
CONCLUSIONS
Uromedix-3D system can accurately and efficiently reconstruct the 3D structure of human kidneys and the renal lesions based on enhanced CT data. The reconstructed 3D model allows objective assessment of the spatial anatomical relationship of the lesions to provide assistance in surgical planning.
Humans
;
Imaging, Three-Dimensional
;
Kidney
;
Kidney Calculi
;
diagnostic imaging
;
surgery
;
Kidney Neoplasms
;
diagnostic imaging
;
surgery
;
Tomography, X-Ray Computed
4.Value of real-time contrast-enhanced ultrasound in diagnosis of renal solid renal lesions.
Xin LI ; Ping LIANG ; Xiaoling YU ; Jie YU ; Zhigang CHENG ; Zhiyu HAN ; Fangyi LIU ; Mengjuan MU
Journal of Southern Medical University 2014;34(6):890-895
OBJECTIVETo investigate the value of real-time contrast-enhanced ultrasound (CEUS) in the diagnosis and differential diagnosis of renal solid renal lesions (RSLs).
METHODSWe retrospectively analyzed 140 cases of 152 RSLs with a mean diameter 3.1∓1.9 cm. CEUS was performed and the perfusion characteristics were analyzed using contrast pulse sequences (CPS) technique. CEUS findings were compared with biopsy histopathologic findings.
RESULTSA total of 137 malignant lesions (including 127 renal clear cell carcinomas, 8 renal papillary carcinomas and 2 chromophobe cell carcinomas) and 15 benign lesions (13 angiomyolipomas and 2 renal oncocytomas) were detected. Of the 137 malignant lesions, 98 (71.5%) showed contrast agent fast perfusion and hyper-enhancement or iso-enhancement in cortical phase, 104 (75.9%) showed hypo-enhancement in later corticalmedullary and late phase, and 125 (91.2%) showed rim-like enhancement. Tumors with a diameter ≤2 cm presented with homogeneous enhancement, and those ranging from 2 to 4 cm showed heterogeneous enhancement with a honeycomb feature; tumors greater than 4 cm featured heterogeneous enhancement with large no-enhancement necrotic areas. Of the benign lesions, 13 angiomyolipomas and 2 renal oncocytomas showed slow wash-in and slow wash-out mode. The diagnostic specificity, accuracy and positive predictive value of CEUS for RSLs were 94.9%, 96.1%, and 73.7%, as compared to 72.3%, 71.1%, and 19.1% with conventional US, respectively (P<0.001). The sensitivity and negative predictive value of CEUS were 93.3% and 99.2%, respectively, significantly higher than those of conventional US (60% and 94.3%, P=0.084, and 0.062, respectively).
CONCLUSIONReal-time CEUS can provide valuable information for improving the diagnosis and differential diagnosis of RSLs.
Adenoma, Oxyphilic ; diagnostic imaging ; Carcinoma, Renal Cell ; diagnostic imaging ; Contrast Media ; Diagnosis, Differential ; Humans ; Kidney Diseases ; diagnostic imaging ; Kidney Neoplasms ; diagnostic imaging ; Retrospective Studies ; Sensitivity and Specificity ; Ultrasonography
5.Monitoring of graft flow with color Doppler in simultaneous pancreas-kidney transplant recipients.
Ying TANG ; Xin LI ; Xiang-Yu HU ; Hong-Tao WU ; Peng MAO ; Yu-Hong WANG ; Zhong-Yang SHEN
Acta Academiae Medicinae Sinicae 2008;30(1):54-57
OBJECTIVETo evaluate the clinical value of color Doppler in monitoring graft flow in patients who underwent simultaneous pancreas-kidney (SPK) transplantation.
METHODSTotally 18 patients received color Doppler ultrasonography on day 1, 3, and 7 after SPK. Volumes and arteriovenous velocities of the kidney and pancreas grafts were recorded, and resistance index (RI) was calculated.
RESULTSColor Doppler ultrasound clearly displayed the modality, size, and flow of the kidney and pancreas grafts. Compared with the single kidney grafts, the modality, volume, and arteriovenous velocity of kidney grafts in SPK was not significantly different. Although the volume of pancreas graft was remarkably larger than the normal control pancreas early after transplantation, no difference in artery velocity was found between pancreas graft and normal pancreas. The spectrum of the portal vein in pancreas grafts showed the typical spectrum of iliac veins.
CONCLUSIONColor Doppler ultrasound is sensitive in monitoring the graft flow of SPK recipients and can be used to identify postoperative vascular complications and evaluate tissue perfusion.
Humans ; Iliac Vein ; diagnostic imaging ; Kidney ; blood supply ; diagnostic imaging ; Kidney Transplantation ; Pancreas ; blood supply ; diagnostic imaging ; Pancreas Transplantation ; Portal Vein ; diagnostic imaging ; Ultrasonography, Doppler, Color
6.Fetal anteroposterior renal pelvic diameter for predicting antenatal hydronephrosis requiring postnatal surgery.
Zhan WANG ; Daxing TANG ; Hongjuan TIAN ; Fang YANG ; Hong WEN ; Junmei WANG ; Chang TAO
Journal of Zhejiang University. Medical sciences 2019;48(5):493-498
OBJECTIVE:
To assess the value of fetal anteroposterior renal pelvic diameter (APD) in predicting antenatal hydronephrosis requiring surgical treatment after birth.
METHODS:
A total of 525 cases of antenatal hydronephrosis detected by prenatal ultrasonography (ultrasound index APD ≥ 4 mm in the second trimester and APD ≥ 7 mm in the third trimester) in Zhejiang Prenatal Diagnosis Center from June 2007 to June 2018 were retrospectively analyzed. ROC curve was used to analyze the relationship between these ultrasound indicators and the requirement for surgical treatment after birth.
RESULTS:
There were 162 cases (30.9%) diagnosed in the second trimester and 363 cases (69.1%) diagnosed in the third trimester; 131 cases were diagnosed pathologically after birth, of which 121 finally underwent surgical treatment. The area under ROC curve (AUC) of APD in middle pregnancy for prediction of requiring surgery 1-12 years after birth was 0.910; the cut-off value of APD was 8.45 mm with a sensitivity of 97.1%, specificity of 70.9%, positive predictive value (PPV) of 47.9%, and negative predictive value (NPV) of 98.9%. The AUC of APD in late pregnancy for prediction of requiring surgery 1-12 years after birth was 0.800; the cut-off value of APD was 12.25 mm with a sensitivity of 66.7%, specificity of 81.2%, PPV of 51.7%, and NPV of 89.1%.
CONCLUSIONS
APD in pregnancy can be used to predict whether the fetus with hydronephrosis needs surgical treatment after birth, and the prediction value of APD in the middle pregnancy is better.
Female
;
Fetus
;
diagnostic imaging
;
Humans
;
Hydronephrosis
;
diagnostic imaging
;
surgery
;
Kidney Pelvis
;
diagnostic imaging
;
Pregnancy
;
Retrospective Studies
;
Ultrasonography
7.CT differential diagnosis of cystic nephroma and multilocular cystic renal cell carcinoma.
Jinkun ZHAO ; Zhaoxiang YE ; Renju BAI ; Xusheng CHEN ; Yi PAN
Chinese Journal of Oncology 2015;37(11):845-849
OBJECTIVETo study the CT findings of cystic nephroma (CN) and multilocular cystic renal cell carcinoma (MCRCC) and to improve the accuracy of preoperative diagnosis of these two diseases.
METHODSThe CT findings of nine CN cases and 19 MCRCC cases confirmed by pathology were blindly reviewed and compared with their pathological results. Fisher's exact test and independent-samples T test were applied to statistically analyze some of the CT features of the CN and MCRCC lesions.
RESULTSThe thickness of cystic walls and partitions in the nine CN cases ranged from 0.5 to 5 mm. Cystic walls and partitions were slightly thicker in some parts without visible mural nodules. Varying amounts of solid tissue could be found in all the 19 MCRCC tumors, and the cystic walls and partitions were found partially thickened ranging from 3 mm to 13 mm. Eight cases were with mural nodules (nodule diameter: 4.5-16 mm). Nine cases of CN tumors were lobulated and 7 protruded into the renal sinus. Three out of the 19 MCRCC presented shallow lobulation, and 7 tumors protruded into the renal sinus. The CT contrast-enhancement scanning displayed moderate delayed enhancement in the cystic walls and partitions in 8 cases. The enhanced scanning revealed that all the nine cases showed enhancement of the cystic walls and partitions, while 8 cases of them had mild to moderate delayed enhancement. The cystic walls, partitions and nodules were enhanced in 19 MRCC cases, among them 17 cases displayed obvious enhancement in the cortical phase. Among the differences of CT findings between MC and MRCC, the shallow lobulation, protruding into the renal sinus, mural nodules, cystic wall and partition thickness, and net growth in the cortical and nephrographic phase were statistically significantly different (P<0.05 for all).
CONCLUSIONSCT scan can provide significant evidence for CN and MCRCC diagnosis. CN cases usually present relatively thin and even cystic walls and partitions without mural nodules and with shallow lobulation and protruding into the renal sinus. The enhancement is mild to moderate, dynamic and delayed, while the opposite CT findings may indicate a higher possibility of MCRCC.
Adenocarcinoma, Clear Cell ; diagnostic imaging ; Carcinoma, Renal Cell ; diagnostic imaging ; Diagnosis, Differential ; Humans ; Kidney ; diagnostic imaging ; Kidney Diseases, Cystic ; diagnostic imaging ; Kidney Neoplasms ; diagnostic imaging ; Tomography, X-Ray Computed
9.Imaging manifestations of renal primary neuroectodermal tumors.
Xi-Wen NAN ; Guang-Jian TANG ; Jian-Guo XU ; Tai-Song PENG ; Lai-Sheng MIAO ; Zhi-Gao XU ; Cong BAI ; Ping YU ; Yong-Li GAO ; Bao-Tang HAO
Chinese Medical Journal 2012;125(19):3595-3597