1.Digital subtraction angiography vs. real-time fluoroscopy for detection of intravascular injection during transforaminal epidural block
Yeungnam University Journal of Medicine 2019;36(2):109-114
BACKGROUND: Transforaminal epidural block (TFEB) is an effective treatment option for radicular pain. To reduce complications from intravascular injection during TFEB, use of imaging modalities such as real-time fluoroscopy (RTF) or digital subtraction angiography (DSA) has been recommended. In this study, we investigated whether DSA improved the detection of intravascular injection during TFEB at the whole spine level compared to RTF.METHODS: We prospectively examined 316 patients who underwent TFEB. After confirmation of final needle position using biplanar fluoroscopy, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under RTF; 30 s later, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under DSA.RESULTS: Thirty-six intravascular injections were detected for an overall rate of 11.4% using RTF, with 45 detected for a rate of 14.2% using DSA. The detection rate using DSA was statistically different from that using RTF (p=0.004). DSA detected a significantly higher proportion of intravascular injections at the cervical level than at the thoracic (p=0.009) and lumbar (p=0.011) levels.CONCLUSION: During TFEB at the whole spine level, DSA was better than RTF for the detection of intravascular injection. Special attention is advised for cervical TFEB, because of a significantly higher intravascular injection rate at this level than at other levels.
Analgesia
;
Angiography, Digital Subtraction
;
Fluoroscopy
;
Humans
;
Needles
;
Prospective Studies
;
Radiculopathy
;
Spine
2.Digital subtraction angiography vs. real-time fluoroscopy for detection of intravascular injection during transforaminal epidural block
Yeungnam University Journal of Medicine 2019;36(2):109-114
BACKGROUND:
Transforaminal epidural block (TFEB) is an effective treatment option for radicular pain. To reduce complications from intravascular injection during TFEB, use of imaging modalities such as real-time fluoroscopy (RTF) or digital subtraction angiography (DSA) has been recommended. In this study, we investigated whether DSA improved the detection of intravascular injection during TFEB at the whole spine level compared to RTF.
METHODS:
We prospectively examined 316 patients who underwent TFEB. After confirmation of final needle position using biplanar fluoroscopy, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under RTF; 30 s later, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under DSA.
RESULTS:
Thirty-six intravascular injections were detected for an overall rate of 11.4% using RTF, with 45 detected for a rate of 14.2% using DSA. The detection rate using DSA was statistically different from that using RTF (p=0.004). DSA detected a significantly higher proportion of intravascular injections at the cervical level than at the thoracic (p=0.009) and lumbar (p=0.011) levels.
CONCLUSION
During TFEB at the whole spine level, DSA was better than RTF for the detection of intravascular injection. Special attention is advised for cervical TFEB, because of a significantly higher intravascular injection rate at this level than at other levels.
3.2 Cases of Reduction of Orbital Floor Fracture Using Fibrin Glue for Securing Bioresorbable Panel.
Taejung PARK ; Boyoung KIM ; Kibeom BAE
Journal of Rhinology 2014;21(1):51-54
Many surgical methods for the reconstruction of orbital floor fractures have been reported, and theseinclude transorbital, transantral and transnasal endoscopic approaches, among others. The choice of surgical approach and materials for the reduction of orbital blowout fractures depends on the surgeon's experience and preference. For the cases of large orbital floor fractures, reduction has beenperformed most frequently through the transantral approach, and the herniated orbital tissue generally has been supported by asilastic block, silastic tube or urethral balloon catheter. However, the transantral approach has significant drawbacks that includethe requirement of removal surgery, displacement of materials, and inflammation of the maxillary sinus. To overcome these negative effects, the authors used fibrin glue tosecure the reduction through the transantral approach in two cases of patients with orbital floor fractures.
Catheters
;
Fibrin Tissue Adhesive*
;
Humans
;
Inflammation
;
Maxillary Sinus
;
Orbit*
;
Orbital Fractures
4.Spinal orexin A attenuates opioid-induced mechanical hypersensitivity in the rat
Dong-ho YOUN ; Jiyeon JUN ; Tae Wan KIM ; Kibeom PARK
The Korean Journal of Pain 2022;35(4):433-439
Background:
Repeated administration of opioid analgesics for pain treatment can produce paradoxical hyperalgesia via peripheral and/or central mechanisms. Thus, this study investigated whether spinally (centrally) administered orexin A attenuates opioid-induced hyperalgesia (OIH).
Methods:
[D-Ala2 , N-Me-Phe4 , Gly5 -ol]-enkephalin (DAMGO), a selective µ-opioid receptor agonist, was used to induce mechanical hypersensitivity and was administered intradermally (4 times, 1-hour intervals) on the rat hind paw dorsum. To determine whether post- or pretreatments with spinal orexin A, dynorphin A, and antidynorphin A were effective in OIH, the drugs were injected through an intrathecal catheter whose tip was positioned dorsally at the L3 segment of the spinal cord (5 µg for all). Mechanical hypersensitivity was assessed using von Frey monofilaments.
Results:
Repeated intradermal injections of DAMGO resulted in mechanical hypersensitivity in rats, lasting more than 8 days. Although the first intrathecal treatment of orexin A on the 6th day after DAMGO exposure did not show any significant effect on the mechanical threshold, the second (on the 8th day) significantly attenuated the DAMGO-induced mechanical hypersensitivity, which disappeared when the type 1 orexin receptor (OX1R) was blocked. However, intrathecal administration of dynorphin or an anti-dynorphin antibody (dynorphin antagonists) had no effect on DAMGO-induced hypersensitivity. Lastly, pretreatment with orexin A, dynorphin, or anti-dynorphin did not prevent DAMGO-induced mechanical hypersensitivity.
Conclusions
Spinal orexin A attenuates mechanical hyperalgesia induced by repetitive intradermal injections of DAMGO through OX1R. These data suggest that OIH can be potentially treated by activating the orexin A-OX1R pathway in the spinal dorsal horn.
5.In Vivo Vibration Measurement of Middle Ear Structure Using Doppler Optical Coherence Tomography: Preliminary Study
Doekmin JEON ; Nam Hyun CHO ; Kibeom PARK ; Kanghae KIM ; Mansik JEON ; Jeong Hun JANG ; Jeehyun KIM
Clinical and Experimental Otorhinolaryngology 2019;12(1):40-49
OBJECTIVES: Doppler optical coherence tomography (DOCT) is useful for both, the spatially resolved measurement of the tympanic membrane (TM) oscillation and high-resolution imaging. We demonstrated a new technique capable of providing real-time two-dimensional Doppler OCT image of rapidly oscillatory latex mini-drum and in vivo rat TM and ossicles. METHODS: Using DOCT system, the oscillation of sample was measured at frequency range of 1–4 kHz at an output of 15 W. After the sensitivity of the DOCT system was verified using a latex mini-drum consisting of a 100 μm-thick latex membrane, changes in displacement of the umbo and contacted area between TM and malleus in normal and pathologic conditions. RESULTS: The oscillation cycles of the mini-drum for stimulus frequencies were 1.006 kHz for 1 kHz, 2.012 kHz for 2kHz, and 3.912 kHz for 4 kHz, which means that the oscillation cycle of the mini-drum become short in proportional to the frequency of stimuli. The oscillation cycles of umbo area and the junction area in normal TM for frequencies of the stimuli showed similar integer ratio with the data of latex mini-drum for stimuli less than 4 kHz. In the case of middle ear effusion condition, the Doppler signal showed a tendency of attenuation in all frequencies, which was prominent at 1 kHz and 2 kHz. CONCLUSION: The TM vibration under sound stimulation with frequencies from 1 kHz to 4 kHz in normal and pathologic conditions was demonstrated using signal demodulation method in in vivo condition. The OCT technology could be helpful for functional and structural assessment as an optional modality.
Animals
;
Ear, Middle
;
Latex
;
Malleus
;
Membranes
;
Methods
;
Otitis Media with Effusion
;
Rats
;
Tomography, Optical Coherence
;
Tympanic Membrane
;
Vibration
6.Treatment of Low Back Pain and Sciatica by Local Anesthetic Injection through Epidural Catheter in Pregnant Woman
Jiseob KIM ; Hyo-jin LEE ; Najeong HA ; Insu KIM ; Kibeom PARK
Keimyung Medical Journal 2021;40(2):125-128
Lower back pain and sciatica are common symptoms in pregnancy. Treatment options for these conditions include physical therapy, medication, interventional treatment, and surgery. This case report involved a 32 weeks pregnant woman, who visited the emergency room with a three day history of lower back and right leg pain and a visual analogue scale (VAS) score of 9 - 10. Spinal computed tomography revealed lumbar 4/5 and 5/S1 disc protrusions. An epidural catheter was placed around the L3/4 vertebrae, and 6 ml of 0.15% ropivacaine was administered for pain control. Subsequently, her VAS score reduced to 2 - 3 and she was discharged five days later.