1.Radius measurement and depth correction of veins in upper extremity venous ultrasound image
Keyou GUO ; Haijing JIA ; Yanqing WANG
Military Medical Sciences 2017;41(6):516-519
Objective To calculate and measure the depth and radius of the target vessel in the upper limb venous ultrasound image in order to contribute to automatic venipuncture.Methods Two methods of measuring the radius of veins in an ultrasonic vein cross section image were adopted.One method was to segment the vein based on the threshold selected after evaluation, and then scan the upper and lower edges of the vein to obtain the radius.The other method was based on Otsu method,which was to divide the vein and then morphologically process the binary image.The radius was calculated in a manner similar to the first method.After the radius was obtained, the depth of the vein was corrected in conjunction with the radius.Results The above two methods were tested on 500 upper limb venous ultrasound images.The accuracy rate of the first method was 93.0%, and that of the second method was 99.4%.Conclusion The method based on Otsu and morphological processing is more effective for radius measurement of veins in upper limb venous ultrasound image.
2.A report of 15 cases of intraductal papillomatosis
Keyou WANG ; Hongchuan JIANG ; Jie LI
Chinese Journal of Minimally Invasive Surgery 2001;0(04):-
Objective To discuss the diagnosis and treatment of intraductal papillomatosis. Methods Fifteen cases of intraductal papillomatosis were analyzed retrospectively. Results Of the 15 cases,preoperative diagnosis of intraductal papillomatosis was made in 8 cases who had received fiberoptic ductoscopy,while the rest of 7 cases who had not undergone ductoscopy were wrongly diagnosed.Postoperative pathological findings revealed 2 cases of partial malignant change and 1 case of contralateral infiltrating lobular carcinoma.Reoperation was required in 3 cases because of relapse,the relapse rate being 20%. Conclusions Intraductal papillomatosis is absolutely different from intraductal papilloma.It presents the potentiality of malignancy,and is subject to relapse after local resection.Fiberoptic ductoscopy may improve the diagnosis rate for this disease.
3.MORHPOLOGICAL AND HISTOCHEMICAL OBSERVATION OF MYOCARDIUM OF KESHAN DISEASE
Keyou GE ; Xiaoshu CHEN ; Anna XUE ; Jin BEI ; Shuqin WANG ; Guangshan MENG
Acta Nutrimenta Sinica 1956;0(02):-
Keshan disease was an endemic cardiomyopathy in China. The very low selenium intake of local people was considered to be an important causal factor. The main pathological characteristics of this disease was multifo-cal necrosis and fibrous replacement of myocardium that was scattered throughout the wall of all chambers.Two patterns of myocardial necrosis, myofibrillar pattern and mitochondrial pattern were distinguished in electron microscopy. The myofibrillar pattern was characterized by myofibril segmentation. It agreed well with the contraction band necrosis described in light microscopy. It was mainly seen in acute Keshan heart and might be related to circulatory disorders. Mitochondrial pattern was identical with myocytolysis of conventional pathology. It represented the typical lesion of Keshan disease.Mitochondria showed early and conspicuous changes in involved myo-cytes. Myofibrillar damage seemed to be secondary to the mitochondrial injury in the development of myocytolysis.Histochemical studies revealed that the acid phosphatase activity was obviously increased in muscle fibers surrounding the necrotic foci, and the succinic dehydrogenase activity was greatly reduced in damaged myocardio-cytes.
4.Application of mobile medical intelligence software combined with OBE-CBCL dual-track teaching method in standardized training of orthopaedic residents
Chen XU ; Chongchong CHU ; Zhaodong WANG ; Yajun LIU ; Keyou DUAN ; Jianzhong GUAN
Journal of Shenyang Medical College 2024;26(2):221-224
Objective:To explore the effect of mobile medical intelligent software combined with OBE-CBCL dual-track teaching method in standardized training of orthopaedic residents.Methods:The orthopedic residents who received resident standardized training in our hospital from Jan 2022 to Sep 2022 were selected as the study subjects.The orthopedic residents who received regular teaching method from Jan 2022 to Mar 2022 were group A,orthopedic residents who received mobile medical intelligent software + regular teaching method from Apr 2022 to Jun 2022 were group B,and the orthopedic residents who received mobile medical intelligent software + OBE-CBCL dual-track teaching method from Jul 2022 to Sep 2022 were group C.All three groups participated in the relevant professional theoretical knowledge assessment,Mini-CEX,and satisfaction survey at the time of discharge.Results:The scores of professional theoretical knowledge assessment in groups B and C were higher than that in groups A,and it was higher in group C than that in group B(P<0.05).The scores of each item of Mini-CEX in groups B and C were higher than those in group A(P<0.05).Except for clinical judgment ability,the scores of the other items of Mini-CEX in group C was higher than those in group B(P<0.05).In the satisfaction survey,the scores of deepening knowledge mastery in groups B and C were higher than that in group A,and that in group C was higher than that in group B(P<0.05).The scores of improving clinical thinking and stimulating learning interest in groups B and C were higher than those in group A(P<0.05),and the scores of improving team assistance and overall satisfaction in group C were higher than those in groups A and B(P<0.05).Conclusion:Mobile medical intelligent software combined with OBE-CBCL dual-track teaching can significantly improve teaching effect of orthopaedic resident standardized training.
5.Study on application of ultrasonic bone curette in anterior cervical spine surgery.
Chen XU ; Zhaodong WANG ; Yajun LIU ; Zhonglian ZHU ; Keyou DUAN ; Min WU ; Jianzhong GUAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(8):996-1001
OBJECTIVE:
To investigate the effect of ultrasonic bone curette in anterior cervical spine surgery.
METHODS:
A clinical data of 63 patients with cervical spondylosis who were admitted between September 2019 and June 2021 and met the selection criteria was retrospectively analyzed. Among them, 32 cases were operated with conventional instruments (group A) and 31 cases with ultrasonic bone curette (group B). There was no significant difference between the two groups (P>0.05) in gender, age, surgical procedure, surgical segment and number of occupied cervical space, disease type and duration, comorbidities, and preoperative Japanese Orthopaedic Association (JOA) score, cervical dysfunction index (NDI), and pain visual analogue scale (VAS) score. The operation time, intraoperative bleeding, postoperative drainage, postoperative hospital stay, and the occurrence of postoperative complications were recorded in both groups. Before operation and at 1, 3, and 6 months after operation, the JOA score and NDI were used to evaluate the function and the postoperative JOA improvement rate was calculated, and VAS score was used to evaluate the pain improvement. The anteroposterior and lateral cervical X-ray films were taken at 1, 3, and 6 months after operation to observe whether there was any significant loosening and displacement of internal fixators.
RESULTS:
Compared with group A, group B had shorter operation time and postoperative hospital stay, less intraoperative bleeding and postoperative drainage, and the differences were significant (P<0.05). All incisions healed by first intention in the two groups, and postoperative complications occurred in 5 cases (15.6%) in group A and 2 cases (6.5%) in group B, showing no significant difference (P>0.05). All patients were followed up 6-12 months (mean, 7.9 months). The JOA score and improvement rate gradually increased in groups A and B after operation, while the VAS score and NDI gradually decreased. There was no significant difference in VAS score between 3 months and 1 month in group B (P>0.05), and there were significant differences between the other time points of each indicator in the two groups (P<0.05). At 1, 3, and 6 months after operation, the JOA score and improvement rate in group B were better than those in group A (P<0.05). X-ray films examination showed that there was no screw loosening or titanium plate displacement in the two groups after operation, and the intervertebral cage or titanium mesh significantly sank.
CONCLUSION
Compared with traditional instruments, the use of ultrasonic bone curette assisted osteotomy in anterior cervical spine surgery has the advantages of shorter operation time, less intraoperative bleeding, less postoperative drainage, and shorter hospital stay.
Humans
;
Ultrasonics
;
Retrospective Studies
;
Titanium
;
Postoperative Complications/epidemiology*
;
Bone Plates
;
Cervical Vertebrae/surgery*
6.Early effectiveness of Ti-Robot assisted femoral neck system for minimally invasive treatment of elderly Garden type Ⅱ and Ⅲ femoral neck fractures.
Yajun LIU ; Zhaodong WANG ; Chen XU ; Zhonglian ZHU ; Keyou DUAN ; Jianzhong GUAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(12):1471-1476
OBJECTIVE:
To investigate the early effectiveness of the Ti-Robot assisted femoral neck system (FNS) in the treatment of elderly Garden type Ⅱ and Ⅲ femoral neck fractures.
METHODS:
A retrospective analysis was conducted on the clinical data of 41 elderly patients with Garden type Ⅱ and Ⅲ femoral neck fractures who were admitted between December 2019 and August 2022 and met the selection criteria. Among them, 21 cases were treated with Ti-Robot assisted FNS internal fixation (study group), and 20 cases were treated solely with FNS internal fixation (control group). There was no significant difference in baseline data, including gender, age, side, cause of injury, time from injury to surgery, fracture Garden classification, and fracture line classification, between the two groups ( P>0.05). Surgical effectiveness was evaluated based on parameters such as operation time (including incision time and total operation time), reduction level, number of dominant pin insertions, intraoperative fluoroscopy frequency, incision length, whether to extend the incision, need for assisted reduction, postoperative hospital stay, fracture healing time, incidence of osteonecrosis of the femoral head, postoperative visual analogue scale (VAS) score at 1 day, and Harris hip score at last follow-up.
RESULTS:
The study group showed significantly shorter incision time, fewer dominant pin insertions, fewer instances of extended incisions, fewer intraoperative fluoroscopy frequency, and smaller incisions than the control group ( P<0.05). There was no significant difference in total operation time, reduction level, and assisted reduction frequency between the two groups ( P>0.05). Both groups achieved primary wound healing postoperatively, with no complications such as incision leakage or skin infection. All patients were followed up 12-24 months with an average of 14.6 months. Fractures healed in both groups, with no significant difference in healing time ( P>0.05). There was no significant difference in postoperative hospital stay between the two groups ( P>0.05). The study group showed significantly better VAS score at 1 day after operation and Harris hip score at last follow-up when compared to the control group ( P<0.05). No complication such as internal fixation failure, fracture displacement, or hip joint varus occurred in both groups during the follow-up. Osteonecrosis of the femoral head occurred in 1 patient of the control group, while no was observed in the study group, and the difference in the incidence of osteonecrosis of the femoral head between the two groups was not significant ( P=0.488).
CONCLUSION
Compared to sole FNS internal fixation treatment, Ti-Robot assisted FNS internal fixation for elderly Garden typeⅡ and Ⅲ femoral neck fractures can reduce incision time, achieve minimally invasive and accurate nail implantation, and decrease intraoperative fluoroscopy frequency, leading to improved postoperative hip joint function recovery.
Humans
;
Aged
;
Femur Neck
;
Robotics
;
Retrospective Studies
;
Treatment Outcome
;
Titanium
;
Femoral Neck Fractures/surgery*
;
Fracture Fixation, Internal
;
Osteonecrosis
;
Surgical Wound