1.Risk factors of primary lung cancer and spirometry.
Yang Keun RHEE ; Keum Man HWANG ; Yong Chul LEE
Tuberculosis and Respiratory Diseases 1993;40(6):646-652
No abstract available.
Lung Neoplasms*
;
Lung*
;
Risk Factors*
;
Spirometry*
2.Clinical studies on acute drug intoxication.
Keum Man HWANG ; Yong Chul LEE ; Soo Teik LEE ; Seung Ryeol LEE ; Yang Keun RHEE
Journal of the Korean Society of Emergency Medicine 1993;4(1):43-52
No abstract available.
4.Nutrition of Low Birth Weight Infants and Infant Formula for Low Weight Infants.
Gyoung Hee KIM ; Choong Hee KIM ; Soo Jee MOON ; Sang Man SHIN ; Dong Gawn HAN ; Keun LEE ; Keun Soo LEE
Journal of the Korean Pediatric Society 1985;28(10):953-959
No abstract available.
Humans
;
Infant Formula*
;
Infant*
;
Infant, Low Birth Weight*
;
Infant, Newborn
5.Ethnic identity of Koreans in the Jilin province of China.
Seung Chul SHIN ; Dong Keun LEE ; Man Kwon KIM ; Ho Young LEE
Journal of Korean Neuropsychiatric Association 1992;31(2):384-414
No abstract available.
China*
6.Cysticercosis and taeniasis in Chollapukdo Province.
Keun Tae LEE ; Chong Hwan KIM ; Chong Tae PARK ; Man Yong LEE
The Korean Journal of Parasitology 1966;4(1):39-45
From 1960 through 1965, 39 cases with epileptic seizure caused by the Cystricercus cellulosae were experienced at Kaejong Mental Hospital, Okku-Gun, Chollapukdo province. The present study was carried on at the area of Chollapukdo province where Cysticercus cellulosae cases were frequently reported. Thrity-nine Cystricercus cellulosae cases(35 male and 4 female) with epileptic seizure visited Kaejong Mental Hospital . Okku-Gun, Chollapukdo during the years of 1960-1965 from various Gun(county): Okku-Gun 13, Kimje-Gun 7, and Soonchang-Gun 6. The high incidence was found at the age group of 20-49 years and the distribution of 214 subcutaneous nodules were as follows: Trunk 56.6 percent, upper extremities 26.6 percent, head and neck 9.3 percent, lower extremities 7.5 percent. According to the address of above 39 cases, taenia infestation of the inhabitants in the area was examined by questionaire form. Plain rural area (Maryong-Ri, Okku-Gun); Among 803 persons interviewed, 4.0 percent or 32 complained the output of Taenia segments. The male group showed higher incidence (6.4 percent) than the female(1.5 percent) . The highest incidence was observed at the age group of 30-39 years. Most of the inhabitants of the area had the eating habit of raw beef and pork. Mountainous rural area(Bok-Heung-Myun, Soonchang-Gun); Among 542 persons interviewed, 33 or 6.1 percent complained Taenia infection. The higher incidence was observed in the male group(8.7 percent) than in the female group(3.1 percent) , and also at the age group of 20-49 years. They had eating habit of raw beef and pork. The species of adult worm were identified by morphological examination. Totally 36 adult worms(Taenia saginata 21, T. solium 15) were obtained from 26 cases, and it was experienced that 5 T. solium were eliminated from one person.
parasitology-helminth-cestoda
;
Taenia solium
;
cysticercus
;
epidemiology
7.Efficacy of capsaicin sensitive nerve on goblet cells and submucosal glands in rats.
Sang Hag LEE ; Heung Man LEE ; Keun JUNG ; Chung Sik CHOI ; Soon Jae HWANG
Korean Journal of Otolaryngology - Head and Neck Surgery 1993;36(2):264-273
No abstract available.
Animals
;
Capsaicin*
;
Goblet Cells*
;
Rats*
8.Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients
Keun-Woo PARK ; Ji-Man PARK ; Keun-Woo LEE
The Journal of Korean Academy of Prosthodontics 2021;59(1):79-87
The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient’s visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an ‘A.I. abutment matching algorithm’ the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner’s advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.
9.Cauda Equina Syndrome in the Lumbar Disc Herniation.
Hong Tae KIM ; Soon Man HONG ; Keun Il LEE ; Jin Wook JUNG ; Yeon Min PARK
Journal of Korean Society of Spine Surgery 1998;5(1):116-121
STUDY DESIGN: A retrospective analysis of the patients who had cauda equina syndrome caused by a herniated lumbar disc. OBJECTIVES: To assess the clinical debates concerning the diagnosis, treatment, and results of treatment. SUMMARY OF LITERATURE REVIEW: This syndrome has been considered as an absolute indication of surgical treatment in the herniated lumbar disc and poor prognosis after surgery were reported. Although there are debates on the timing of surgery, early recognition early surgical treatment are recommended for a better results of treatment. MATERIALS AND METHODS: 23 consecutive patients having a cauda equina syndrome caused by herniated lumbar disc were reviewed retrospectively. They were 14 males and 9 females having ages of 41.6 in average. The incidence of this syndrome was 3.8% of the patients who had surgical treatment of herniated lumbar disc. RESULTS: All patients had bladder dysfunction in addition to the low back pain and radicular pain in the leg, but five patient did not recognize their urinary retention which were shaded by severe leg pain. A surgical treatment were performed for all patients at 6.8 days in average after onset of the bladder dysfunction. At follow-up of 3 years and 3 months in average after surgery, 20 patients(86.9%) had satisfactory resolution of the low back pain and leg pain, and all patients had complete recovery of motor weakness except one patients who had residual foot drop. Bladder function recovered satisfactorily in 18 patients (78.3%), but 4 patients had some difficulty of urination and one patient needed a sphinterotomy for urination. CONCLUSIONS: The cauda equine syndrome in herniated lumbar disc was often not recognized early and a poor result of treatment was not rare, particularly in the patients who had acute onset and severe bladder dysfunction. So, early diagnosis and active surgical treatment are recommended for a better results of treatment.
Cauda Equina*
;
Diagnosis
;
Early Diagnosis
;
Female
;
Follow-Up Studies
;
Foot
;
Humans
;
Incidence
;
Leg
;
Low Back Pain
;
Male
;
Polyradiculopathy*
;
Prognosis
;
Retrospective Studies
;
Urinary Bladder
;
Urinary Retention
;
Urination
10.Fixation Failure of Instrumentation for the Spinal Fusion in Lumbar Region.
Hong Tae KIM ; Soon Man HONG ; In Hak CHOI ; Keun ll LEE ; Jin Wook JUNG
Journal of Korean Society of Spine Surgery 1997;4(2):319-328
STUDY DESIGN: A retrospective review of the patients who have a fixation failure of instrumentalion for the spinal fusion in lumbar region. OBJECTIVES: To assess the incidence and different types of the mechanical failure of fixation and to evaluate their managements and their influences on the progression of a spinal fusion and to the clinical outcomes. SUMMARY OF LITERATURE REVIEW: Most of the spine surgeons have been experiencing the mechanical failures after instrumentations for a spinal fusion, eden though the incidence is decreasing with a modification of the implants. Reports on this problem are sporadic in conjunction with the other topics, rarely focusing on their management and their influences on the final outcomes. MATERIALS AND METHODS: 338 consecutive patients who had a lateral fusion in the lumbar region with an instrumentation of pedicle screws and rods, mostly with decompression, were reviewed to analyse the fixation failures of instrumentation after surgery. RESULTS: There were 26 patients (7.7%) who had the fixation failures of instrumentation, in terms of loosening around the pedicle screws in 18 patients (5.3%), the breakage of the pedicle screws in fide patients (1.5%), and the migration of a rod in three patients (0.9%). They were managed by prolonged use of brace and ergonomic back cares. Even with the fixation failures, 19 patients (73.1%) disclosed solid union uneventfully, but one patient had re-operation to obtain solid fusion. The final outcomes were satisfactory in 22 patients (84.6%), including four of six patients who had pseudoarthrosis. CONCLUSIONS: The fixation failure of instrumentation after a spinal fusion in lumbar region was not rare, but the progression of a spinal fusion usually quite well achieved and the final outcomes were not so bad, even with the implant failures and pseudoarthrosi s. Except for the persistently symptomatic pseudoarthrosis, only a prolonged use of brace and the ergonomic back cares are recommended for symptomatic patients.
Braces
;
Decompression
;
Humans
;
Incidence
;
Lumbosacral Region*
;
Pseudarthrosis
;
Retrospective Studies
;
Spinal Fusion*
;
Spine