1.Correlation factors for and clinical characteristics of urosepsis shock after endourology surgery
Yi LIU ; Wen NI ; Xiaolin WANG ; Yan MENG ; Xiaojian WAN ; Jinbao LI ; Keming ZHU ; Xiaoming DENG
Chinese Journal of Anesthesiology 2012;32(6):724-726
ObjectiveTo identify the correlation factors for urosepsis shock after endourology surgery and analyze its clinical characteristics.MethodsFifty-eight patients with urosepsis without shock and 15 patients with shock were studied.Factors which may be correlated with the development of sepsis were analyzed including age,sex,ASA physical status,history of urinary tract infection,preoperative leukocyturia,urine bacteria culture,prophylactic antimicrobial treatment,pyonephrosis,type of surgery,duration of operation,blood leukocyte count and concentration of creactive protein at the end of surgery,the time when the signs of infection (shivering,agitation,nausea or vomiting) first appeared.Changes in BP in patients with urosepsis shock,scores for multiple organ dysfunction syndrome as well as treatment and prognosis were also recorded.ResultsFemale sex and early emergence of signs of infection after surgery were correlated with urosepsis shock.Abrupt hypotension was usually the first manifestation of urosepsis shook.The lowest systolic BP was positively correlated with the time when diagnosis of shock was made and negatively correlated with the length of ICU stay and the highest multiple organ dysfunction syndrome scores but not correlated with shock correction time.All patients with urosepsis shock recovered completely when discharged from hospital.ConclusionFemale sex and patients with early emergence of signs of infection are prone to develop urosepsis shock after endourology operation.The prognosis of urosepsis shock is good if diagnosed and treated in time.
2.Study on Effects of Saikosaponin-d on TPA,PAI,MDA and NO in Rats with Liver Fibrosis
Fang WAN ; Jingzhen GUO ; Xin LI ; Ping LI ; Yuwu CHEN ; Keming LI ; Chen WANG ; Yun ZHANG ; Jing LI ; Yan LIU
China Pharmacy 2005;0(24):-
OBJECTIVE:To investigate the effects of saikosaponin-d(SSd) on tissue plasminogen activator(TPA),plasminogen activator inhibitor(PAI),malonaldehyde(MDA) and NO in rats with liver fibrosis induced by dimethylnitrosamine(DMN).METHODS:Eighteen SD healthy rats were randomized to control group(NS ip qd for 4 weeks),model group(10mg? kg-1 DMN ip 3 times per week for 4 weeks) and SSd-treated group(10mg? kg-1 DMN ip 3 times per week + SSd 1.8 mg? kg-1 ip for 28 consecutive days).All rats were killed 1h after the last time of administration,blood samples were taken from abdominal aorta and liver samples were taken for the observation of pathology and detection of indices of TPA,PAI,MDA and NO etc.RESULTS:SSd could lessen the degree of liver fibrosis and improve the fibrinolytic activities of TPA and PAI,meanwhile,it showed clearance effect on MDA and marked protective effect on hepatic cells.There were significant differences between SSd-treated group and the model group.CONCLUSION:SSd exhibited protective function on experimental hepatic fibrosis in rats,which may be attributed to the improving of fibrinolytic activity,eliminating of lipid peroxidation and enhancing of NO level.
3.Application of U-shaped transdermal surgical navigator based on three-dimensional reverse design in cannulated screwing for femoral neck fracture
Liang CHEN ; Dawei GAO ; Yufeng WU ; Jinwu WANG ; Huiliang ZHANG ; Haihong CHEN ; Jianlong HUANG ; Keming WAN
Chinese Journal of Orthopaedic Trauma 2017;19(11):966-972
Objective To explore application of our self-designed U-shaped transdermal surgical navigator based on three-dimensional reverse design in cannulated screwing for femoral neck fracture Methods A retrospective study was done of 5 patients with femoral neck fracture who had been treated from August 2016 to March 2017.They were 3 men and 2 women,aged from 33 to 60 years (average,46.5 years).Thin layer CT scanning was conducted on the patients' affected hip (at the left side in 2 cases and at the right side in 3).Based on their CT data,3D design software and 3D printing technique were used to manufacture the U-shaped transdermal surgical navigator and a real-sized model of the fracture.Operations were simulated using the U-shaped transdermal surgical navigator on the fracture model to determine the angle,depth and location of the screwing.Fixation of the fracture with cannulated screws was conducted after confirmation of satisfactory surgical parameters.The postoperative X-ray films of the patients were reviewed.Evaluations were conducted of the screw position,operating time,volume of operative bleeding,and number of intraoperative X-ray shots.Results The screw positions in the 5 patients were consistent with their preoperative design.Four patients had only one shot of fluoroscopy and one patient 3 shots.Their operating time ranged from 15 to 30 minutes,averaging 22.5 minutes;their bleeding ranged from 5 to 10 mL,averaging 7.5 mL.The 5 patients were followed up for an average of 4.5 months (from 3 to 6 months).By the Harris scoring at their final follow-ups,one was excellent,3 good and one fair.No complications like pain,functional impairment of the joint,or collapse or necrosis of the femoral head occurred during the follow-up.Conclusions Our self-designed U-shaped transdermal surgical navigator based on three-dimensional reverse design can significandy improve the accuracy and safety of the cannulated screwing for femoral neck fractures.The operation is minimally invasive,reducing operating time and intraoperative blood loss.
4. HIV and syphilis infection and related medical treatment status of low-fee female sex workers in three provinces of China, 2012-2015
Wei DONG ; Chu ZHOU ; Manhong JIA ; Yuejiao ZHOU ; Xi CHEN ; Jun KANG ; Ganggang FANG ; Chunwei QIN ; Jiayu WEI ; Xiaoling MI ; Yanbo WAN ; Zunyou WU ; Keming ROU
Chinese Journal of Preventive Medicine 2018;52(12):1239-1242
Objective:
To understand the HIV and syphilis infection and related treatment status of low-fee female sex workers (FSWs) in 3 provinces of China.
Methods:
Four cross-sectional survey data of low-fee FSWs from six cities (counties) in Guangxi, Yunnan and Hunan Province between October 2012 and July 2015 were obtained from the national science and technology major special project intervention study for reducing sexually transmitted diseases (STDs) and acquired immunodeficiency syndrome (AIDS) in low-fee FSWs' database, which included social demographic characteristics, sexual service characteristics and related medical care seeking behaviors, etc. A total of 2 050 subjects were included in the database.
Results:
The age of the subjects was (35.16±9.76) years old, with a minimum age of 15 and a maximum age of 67. Those who use condoms every time in commercial sex accounted for 58.9% (
5.Multi-criteria decision model in treatment of adolescent scoliosis with three-dimensional printed scoliosis orthosis
Hongsheng ZHANG ; Hanwei HUANG ; Jinwu WANG ; Junwei ZHENG ; Rixin LIU ; Zijie LIAO ; Peng WANG ; Yuanjing XU ; Zanbo WANG ; Keming WAN
Chinese Journal of Tissue Engineering Research 2024;28(30):4806-4811
BACKGROUND:Traditional scoliosis orthosis has some disadvantages,such as complex manufacturing process,long processing cycle,poor fit and so on.Three-dimensional printed scoliosis orthosis has the advantages of high manufacturing precision and personalization. OBJECTIVE:To evaluate the efficacy of three-dimensional printed scoliosis orthosis for scoliosis based on multi-criteria decision model. METHODS:Clinical data of 72 patients with scoliosis admitted to Chen Xinghai Hospital of Integrated Traditional Chinese and Western Medicine from January 2019 to October 2022 were retrospectively collected and divided into two groups according to the treatment of orthosis.Study group(n=23)received three-dimensional printed scoliosis orthosis.Traditional group(n=49)received the traditional polypropylene spine brace treatment.The clinical efficacy and complications were compared between the two groups.A multi-criteria decision model for the treatment of scoliosis with three-dimensional printed scoliosis orthosis was established,and the stability of the benefit value,risk value and decision model of the two groups were evaluated. RESULTS AND CONCLUSION:(1)Compared with the traditional group,there were significant differences in the top vertebral offset distance,Cobb angle,top vertebral rotation,Functional Movement Screen score,visual analog scale score and total effective rate in the study group at 6 months after surgery(P<0.05).(2)Among the benefit indexes,Cobb angle had the greatest impact on the condition of patients,while the risk indexes had the greatest impact on dyspnea.(3)The benefit values of the study group and the traditional group for scoliosis were 79 and 64,and the risk values were 74 and 57,respectively.The combined benefit and risk values found that the benefit-risk value of the study group was 16 higher than that of the traditional group.(4)In the range of 0-100%relative risk weight,the benefit-risk value of the study group was always higher than that of the traditional group,which proved that the multi-criteria decision-making model had good stability.(5)It is indicated that three-dimensional printed scoliosis orthosis can better restore the physiological curvature of scoliosis and improve the efficiency of treatment.
6. Accuracy evaluation for 3D bone reconstruction based on medical 3D reconstruction software
Yuanjing XU ; Zhiyuan LIU ; Yihao LIU ; Zezheng YANG ; Keming WAN ; Fei LIU ; Jinwu WANG ; Kerong DAI
Chinese Journal of Orthopaedic Trauma 2019;21(10):894-900
Objective:
To investigate the feasibility of an accuracy evaluation method for 3D reconstructed bone model based on 3D reconstruction software Arigin3D Pro.
Methods:
Pig femurs were used as solid models which were scanned by CT and MRI respectively. The scan data were imported into software Arigin3D Pro for 3D model reconstruction by 3 operators with different reconstruction experience (≤1 year, 2 to 3 years, and ≥4 years, respectively). Each operator reconstructed the femurs 3 times and in each reconstruction measured the diameter of the femoral head, the length of the femur and the width of the knee joint at the distal end of the femur 3 times respectively using software Geomagic Wrap. The above parameters of the solid models were measured using a vernier caliper. The parameter values of reconstructed models and solid models were compared and the differences were analyzed.
Results:
The measurements by Geomagic Wrap showed deviations between the CT and MRI reconstruction models and the solid models, and the maximum deviation percentages were 1.47% and 1.08%, respectively. The percentages of intra-operater difference ranged from 0.29% to 1.53%; the 3D models reconstructed by operators with different reconstruction experience were not identical.
Conclusions
It is a feasible accuracy evaluation method to compare key parameters between the 3D bone model reconstructed by software Arigin3D Pro and the real animal bone. The deviations of 3D reconstructed bone model based on CT and MRI images are acceptable. The accuracy of 3D bone construction is related to the difference in operators.