1.Lymphopenia and Elevated Blood C-Reactive Protein Levels at Four Days Postoperatively Are Useful Markers for Early Detection of Surgical Site Infection Following Posterior Lumbar Instrumentation Surgery.
Eiichiro IWATA ; Hideki SHIGEMATSU ; Munehisa KOIZUMI ; Hiroshi NAKAJIMA ; Akinori OKUDA ; Yasuhiko MORIMOTO ; Keisuke MASUDA ; Yasuhito TANAKA
Asian Spine Journal 2016;10(2):220-225
STUDY DESIGN: Case-control study. PURPOSE: To identify the characteristics of candidate indexes for early detection of surgical site infection (SSI). OVERVIEW OF LITERATURE: SSI is a serious complication of spinal instrumentation surgery. Early diagnosis and treatment are crucial for the welfare of the patient postoperation. METHODS: We retrospectively reviewed laboratory data of patients who underwent posterior lumbar instrumentation surgery for degenerative spine disease. The sensitivity and specificity of six laboratory markers for early detection of SSI were calculated: greater elevation of the white blood cell count at day 7 than at day 4 postoperatively, greater elevation of the C-reactive protein (CRP) level at day 7 than at day 4 postoperatively, a CRP level of >10 mg/dL at 4 days postoperatively, neutrophil percentage of >75% at 4 days postoperatively, a lymphocyte percentage of <10% at 4 days postoperatively, and a lymphocyte count of <1,000/µL at 4 days postoperatively. Statistical analysis was via Fisher's exact test and a p-value of <0.05 was considered significant. RESULTS: In total, 85 patients were enrolled. Of these, five patients developed deep SSI. The sensitivity and specificity of each index were as follows: index 1, 20.0% and 77.5%; index 2, 20.0% and 83.8%; index 3, 40.0% and 97.5%; index 4, 40.0% and 86.3%; index 5, 0% and 96.3%; and index 6, 80.0% and 80.0%. A significant difference was noted for indexes 3 and 6. CONCLUSIONS: A CRP level of >10 mg/dL at 4 days postoperatively would be useful for definitive diagnosis of SSI, and a lymphocyte count of <1,000/µL at 4 days postoperatively would be a useful screening test for SSI. Although laboratory markers for early detection of SSI have been frequently reported, we believe that it is important to understand the characteristics of each index for a precise diagnosis.
Biomarkers
;
C-Reactive Protein*
;
Case-Control Studies
;
Diagnosis
;
Early Diagnosis
;
Humans
;
Leukocyte Count
;
Lymphocyte Count
;
Lymphocytes
;
Lymphopenia*
;
Mass Screening
;
Neutrophils
;
Retrospective Studies
;
Sensitivity and Specificity
;
Spine
2.Lymphopenia and Elevated Blood C-Reactive Protein Levels at Four Days Postoperatively Are Useful Markers for Early Detection of Surgical Site Infection Following Posterior Lumbar Instrumentation Surgery.
Eiichiro IWATA ; Hideki SHIGEMATSU ; Munehisa KOIZUMI ; Hiroshi NAKAJIMA ; Akinori OKUDA ; Yasuhiko MORIMOTO ; Keisuke MASUDA ; Yasuhito TANAKA
Asian Spine Journal 2016;10(2):220-225
STUDY DESIGN: Case-control study. PURPOSE: To identify the characteristics of candidate indexes for early detection of surgical site infection (SSI). OVERVIEW OF LITERATURE: SSI is a serious complication of spinal instrumentation surgery. Early diagnosis and treatment are crucial for the welfare of the patient postoperation. METHODS: We retrospectively reviewed laboratory data of patients who underwent posterior lumbar instrumentation surgery for degenerative spine disease. The sensitivity and specificity of six laboratory markers for early detection of SSI were calculated: greater elevation of the white blood cell count at day 7 than at day 4 postoperatively, greater elevation of the C-reactive protein (CRP) level at day 7 than at day 4 postoperatively, a CRP level of >10 mg/dL at 4 days postoperatively, neutrophil percentage of >75% at 4 days postoperatively, a lymphocyte percentage of <10% at 4 days postoperatively, and a lymphocyte count of <1,000/µL at 4 days postoperatively. Statistical analysis was via Fisher's exact test and a p-value of <0.05 was considered significant. RESULTS: In total, 85 patients were enrolled. Of these, five patients developed deep SSI. The sensitivity and specificity of each index were as follows: index 1, 20.0% and 77.5%; index 2, 20.0% and 83.8%; index 3, 40.0% and 97.5%; index 4, 40.0% and 86.3%; index 5, 0% and 96.3%; and index 6, 80.0% and 80.0%. A significant difference was noted for indexes 3 and 6. CONCLUSIONS: A CRP level of >10 mg/dL at 4 days postoperatively would be useful for definitive diagnosis of SSI, and a lymphocyte count of <1,000/µL at 4 days postoperatively would be a useful screening test for SSI. Although laboratory markers for early detection of SSI have been frequently reported, we believe that it is important to understand the characteristics of each index for a precise diagnosis.
Biomarkers
;
C-Reactive Protein*
;
Case-Control Studies
;
Diagnosis
;
Early Diagnosis
;
Humans
;
Leukocyte Count
;
Lymphocyte Count
;
Lymphocytes
;
Lymphopenia*
;
Mass Screening
;
Neutrophils
;
Retrospective Studies
;
Sensitivity and Specificity
;
Spine
3.Lymphopenia at 4 Days Postoperatively Is the Most Significant Laboratory Marker for Early Detection of Surgical Site Infection Following Posterior Lumbar Instrumentation Surgery.
Eiichiro IWATA ; Hideki SHIGEMATSU ; Akinori OKUDA ; Yasuhiko MORIMOTO ; Keisuke MASUDA ; Hiroshi NAKAJIMA ; Munehisa KOIZUMI ; Yasuhito TANAKA
Asian Spine Journal 2016;10(6):1042-1046
STUDY DESIGN: Case control study. PURPOSE: To identify the most significant laboratory marker for early detection of surgical site infection (SSI) using multiple logistic regression analysis. OVERVIEW OF LITERATURE: SSI is a serious complication of spinal instrumentation surgery. Early diagnosis and treatment are crucial. METHODS: We retrospectively reviewed the laboratory data of patients who underwent posterior lumbar instrumentation surgery for degenerative spinal disease from January 2003 to December 2014. Six laboratory markers for early SSI detection were considered: renewed elevation of the white blood cell count, higher at 7 than 4 days postoperatively; renewed elevation of the C-reactive protein (CRP) level, higher at 7 than 4 days postoperatively; CRP level of >10 mg/dL at 4 days postoperatively; neutrophil percentage of >75% at 4 days postoperatively; lymphocyte percentage of <10% at 4 days postoperatively; and lymphocyte count of <1,000/µL at 4 days postoperatively. RESULTS: Ninety patients were enrolled; five developed deep SSI. Multivariate regression analysis showed that a lymphocyte count of <1,000/µL at 4 days postoperatively was the sole significant independent laboratory marker for early detection of SSI (p=0.037; odds ratio, 11.9; 95% confidence interval, 1.2–122.7). CONCLUSIONS: A lymphocyte count of <1,000/µL at 4 days postoperatively is the most significant laboratory marker for early detection of SSI.
Biomarkers*
;
C-Reactive Protein
;
Case-Control Studies
;
Early Diagnosis
;
Humans
;
Leukocyte Count
;
Leukocytes
;
Logistic Models
;
Lymphocyte Count
;
Lymphocytes
;
Lymphopenia*
;
Neutrophils
;
Odds Ratio
;
Retrospective Studies
;
Spinal Diseases
;
Surgical Wound Infection*
4.Reliability Comparison between “Distal Radius and Ulna” and “Simplified Tanner–Whitehouse III” Assessments for Patients with Adolescent Idiopathic Scoliosis
Akinori OKUDA ; Hideki SHIGEMATSU ; Hiromasa FUJII ; Eiichiro IWATA ; Masato TANAKA ; Yasuhiko MORIMOTO ; Keisuke MASUDA ; Yusuke YAMAMOTO ; Yasuhito TANAKA
Asian Spine Journal 2020;14(3):280-286
Methods:
We retrospectively evaluated 54 hands of 40 girls with AIS who visited Nara Medical University Hospital from 2000 to 2015 using previously collected radiographs. The examiners included a spine surgeon and a pediatric orthopedic surgeon, each with over 10 years of experience. The reliability of the DRU and sTW3 was evaluated using the kappa coefficient.
Results:
The left-hand radiographs of 40 female patients with AIS (mean age, 13.9±1.7 years; N=54 hands) were evaluated by two blinded examiners using the sTW3 and DRU methods. The highest inter-observer and intra-observer reliabilities (kappa, 0.64 and 0.62, respectively) for radius evaluation were determined. Radius evaluation by the DRU showed the highest agreement rate and smallest error between the inter- and intra-observer examinations.
Conclusions
The DRU was the most reliable assessment tool, and it has the potential to be useful for precisely determining the stage of skeletal maturity in outpatient clinics.
5.Comparison of 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma using endoscopic ultrasound fine-needle aspiration
Mitsuru OKUNO ; Keisuke IWATA ; Tsuyoshi MUKAI ; Yusuke KITO ; Takuji TANAKA ; Naoki WATANABE ; Senji KASAHARA ; Yuhei IWASA ; Akihiko SUGIYAMA ; Youichi NISHIGAKI ; Yuhei SHIBATA ; Junichi KITAGAWA ; Takuji IWASHITA ; Eiichi TOMITA ; Masahito SHIMIZU
Clinical Endoscopy 2024;57(3):364-374
Background/Aims:
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using a 19-gauge needle is an efficient sampling method for the diagnosis of lymphadenopathy. This study compared 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma (ML).
Methods:
Patient characteristics, number of needle passes, puncture route, sensitivity, specificity, and accuracy of cytology/histology for lymphadenopathy were analyzed in patients diagnosed with lymphadenopathy by EUS-FNA using conventional or Franseen needles.
Results:
Between 2012 and 2022, 146 patients met the inclusion criteria (conventional [n=70] and Franseen [n=76]). The median number of needle passes was significantly lower in the conventional group than in the Franseen group (3 [1–6] vs. 4 [1–6], p=0.023). There were no significant differences in cytological/histological diagnoses between the two groups. For ML, the immunohistochemical evaluation rate, sensitivity of flow cytometry, and cytogenetic assessment were not significantly different in either group. Bleeding as adverse events (AEs) were observed in three patients in the Franseen group.
Conclusions
Both the 19-gauge conventional and Franseen needles showed high accuracy in lymphadenopathy and ML classification. Considering sufficient tissue collection and the avoidance of AEs, the use of 19-gauge conventional needles seems to be a good option for the diagnosis of lymphadenopathy.