1.Evaluation of functional suitable digital complete denture system based on 3D printing technology
Kehui DENG ; Hu CHEN ; Yong WANG ; Yongsheng ZHOU ; Yuchun SUN
The Journal of Advanced Prosthodontics 2021;13(6):361-372
PURPOSE:
To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done. MATERIALS AND METHODS Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit.To evaluate accuracy of impression made by diagnostic denture, the final denture was used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients.
RESULTS:
Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups.
CONCLUSION
FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.
2.A preliminary investigation of relations of fat mass and leptin to the bone mineral density in ovariectomic rats.
Lin QIAO ; Liangzhi XU ; Dingzhuo YANG ; Liang LI ; Li DENG ; Kehui XU ; Jing ZHUANG
Journal of Biomedical Engineering 2011;28(4):744-747
The present paper is aimed to investigate the correlation between the fat mass and the bone mass, and to investigate the effect of leptin on bone metabolism in female ovariectomic rats. Forty Wistar female rats, 6-month-old, were randomly divided into the sham surgical (Sham) group and ovariectomic (OVX) group. The body weight, the fat mass inside the abdominal cavity, the bone mineral density (BMD) were determined by DEXA method, and the concentration of leptin was measured by ELISA after operation. The Rats' body mass in ovariectomized group increased significantly (P < 0.05), while the fat mass in abdominal cavity was not increased obviously in ovariectomized group (P = 0.499). The concentration of leptin was no difference between the two groups (P = 0.166). Bone mineral content (BMC)/weight in ovariectomized group was decreased significantly than the sham group (P = 0. 003). The weight at 8th week post-operation was negative correlation with BMC/weight in Sham group and was positive with BMD in OVX group. The fat mass and the leptin concentration were negative correlation with BMC/ weight in Sham group. It was concluded that the fat mass and the leptin were raleted to the BMC/weight.
Adipose Tissue
;
metabolism
;
Animals
;
Bone Density
;
Female
;
Leptin
;
blood
;
Osteoporosis
;
etiology
;
Ovariectomy
;
Random Allocation
;
Rats
;
Rats, Wistar
3. Quantitative evaluation of printing accuracy and tissue surface adaptation of mandibular complete denture polylactic acid pattern fabricated by fused deposition modeling technology
Kehui DENG ; Yong WANG ; Hu CHEN ; Yijiao ZHAO ; Yongsheng ZHOU ; Yuchun SUN
Chinese Journal of Stomatology 2017;52(6):342-345
Objective:
To quantitatively evaluate the adaptation of polylactic acid (PLA) pattern of mandibular complete denture fabricated by fused deposition modeling (FDM) technology.
Methods:
A mandibular complete denture digital model was designed through a complete denture design software based on a pair of standard maxillomandibular edentulous plaster model and their occlusion bases. Ten PLA mandibular complete dentures were printed with a FDM machine. The dentures were scanned with and without the plaster model using a three-dimensional (3D) scanner. In Geomagic software, the scanning data of printed dentures were registered to its computer aided design (CAD) data, and the printing error was analyzed using the multipoint registration command. For quantitatively evaluating the adaptation of the denture, the data of plaster model and PLA denture were registered to the whole data of denture located in the plaster model using the best-fit alignment command, the 3D deviation of the plaster model and tissue surface of the denture represent the space between them. The overall area was separated into three parts: primary stress-bearing area, secondary stress-bearing area and border seal area, and the average deviations of these three parts were measured. The values were analyzed using analysis of variance.
Results:
Compared with the CAD data, the printing error was (0.013±0.004) mm. The overall 3D deviation between PLA denture and plaster model was (0.164±0.033) mm, in which the primary stress-bearing area was (0.165± 0.045) mm, the secondary stress-bearing area was (0.153 ± 0.027) mm, the border seal area was (0.186 ± 0.043) mm. These showed a good fit in the majority parts of the FDM denture to the plaster model. No statistically significant difference was observed between the three areas (
4. Research and development of digital design and fabrication of complete denture
Yuchun SUN ; Ru SUN ; Kehui DENG ; Yong WANG ; Yongsheng ZHOU
Chinese Journal of Stomatology 2018;53(1):60-65
Removable complete denture are still the primary prosthetic solution for edentulous patients. Functional pressure impression obtaining, jaw relation recording, personalized balance occlusion and highly precise fabrication of denture are difficult. The digital restoration technique represented by intraoral three-dimensional scanning and three-dimensional (3D) printing compensates for the shortages of the manual techniques, but there are still many limitations in the application of complete dentures. At present, a few computer aided design and computer aided manufacture (CAD/CAM) complete denture systems have been developed both domestically and abroad, and these system are mainly focused on the digital design and manufacture of denture, and are seldom used for the recording of impression and jaw relation. This review is based on the main clinical procedures of the traditional complete denture restoration, elaborating the research and application status of digital technique in each steps, in order to provide reference for clinical application.