1.Hepatitis B e antigen perturbs the LPS-stimulated production of inflammatory cytokines by mononuclear-derived dendritic cells.
Yong-zhi TANG ; Fei YAN ; Ke-chuan PAN ; Jian-sheng ZHU ; Hua-zhong CHEN ; Min ZHU ; Xi LIN ; Hai-hong ZHAO ; Ming XIAO
Chinese Journal of Hepatology 2013;21(8):590-593
OBJECTIVETo investigate whether hepatitis B e antigen (HBeAg) can modulate the ability of dendritic cells (DCs) to produce inflammatory cytokines (IL-12/IL-6) upon stimulation in vitro.
METHODSPurified adherent mononuclear cells isolated by Ficoll-hypaque density gradient centrifugation were cultured in complete medium containing granulocyte macrophage colony-stimulating factor plus interleukin (IL)-4 to generate immature (i)DCs. Microscopic analysis and flow cytometry were performed to define the phenotypic characteristics of the iDCs. Then, different concentrations (1, 2 and 5 mug/ml) of HBeAg were added to the culture medium and for 24 hrs of incubation. To induce iDCs' maturation, the various groups of cells were incubated for 24 hrs in differentiation culture with lipopolysaccharide (LPS). Effects on secreted inflammatory cytokines were determined by enzyme-linked immunosorbent assay of the cells' supernatants.
RESULTSAll concentrations of HBeAg led to significant reductions in IL-6 (all P less than 0.05). Similar significant reduction trends were seen for IL-12 at the HBeAg concentrations of 2 and 5 mug/ml (both P less than 0.05), but not at the 1 mug/ml concentration.
CONCLUSIONHBeAg may suppress the production of cytokines from DCs; this mechanism may contribute to the immune escape of HBV that supports persistent infection.
Cells, Cultured ; Dendritic Cells ; immunology ; metabolism ; Hepatitis B e Antigens ; immunology ; Humans ; Interleukin-12 ; metabolism ; Interleukin-6 ; metabolism ; Lipopolysaccharides ; adverse effects
2.Prognostic value of soluble MICA levels in the serum of patients with advanced hepatocellular carcinoma.
Jian-Jun LI ; Ke PAN ; Mo-Fa GU ; Min-Shan CHEN ; Jing-Jing ZHAO ; Hui WANG ; Xiao-Ting LIANG ; Jian-Cong SUN ; Jian-Chuan XIA
Chinese Journal of Cancer 2013;32(3):141-148
Serum levels of soluble MHC class I-related chain A (sMICA) are related with the prognosis of various types of cancer; however, few studies on the prognostic value of sMICA in hepatocellular carcinoma (HCC) have been reported. In this study, we retrospectively investigated the relationship between sMICA levels and clinical features of advanced HCC, and we assessed the prognostic value of sMICA in advanced HCC. Furthermore, the relationship of serum sMICA levels and natural killer group 2, member D (NKG2D) expression on natural killer (NK) cells was also evaluated. We detected sMICA levels in the serum of 60 advanced HCC patients using enzyme-linked immunosorbent assay (ELISA) and measured expression levels of NKG2D on NK cells using flow cytometry. We found that serum sMICA levels in HCC patients were in the range of 0.10-6.21 ng/mL. Chi-square analyses showed that sMICA level was significantly related with only tumor size. Survival analysis showed that a high sMICA level was significantly related with poor prognosis among HCC patients. Multivariate analyses indicated that sMICA was an independent prognostic factor. In addition, the levels of CD56+NKG2D+ NK cells were within the range of 11.2%-55.4%, and correlation analyses indicated that sMICA level was negatively correlated with the level of NKG2D+ NK cells. Our results suggest that serum sMICA levels may be an independent prognostic factor for advanced HCC.
Adult
;
Carcinoma, Hepatocellular
;
blood
;
immunology
;
pathology
;
Female
;
Histocompatibility Antigens Class I
;
blood
;
Humans
;
Killer Cells, Natural
;
immunology
;
metabolism
;
Liver Neoplasms
;
blood
;
immunology
;
pathology
;
Male
;
Middle Aged
;
Multivariate Analysis
;
NK Cell Lectin-Like Receptor Subfamily K
;
metabolism
;
Neoplasm Staging
;
Retrospective Studies
;
Survival Rate
;
Tumor Burden
3.Comparative study on anti-tumor immune response of autologous cytokine-induced killer (CIK) cells, dendritic cells-CIK (DC-CIK), and semi-allogeneic DC-CIK.
Qi-Jing WANG ; Hui WANG ; Ke PAN ; Yong-Qiang LI ; Li-Xi HUANG ; Shi-Ping CHEN ; Jia HE ; Miao-La KE ; Jing-Jing ZHAO ; Jian-Jun LI ; Jian-Cong SUN ; Xiao-Ting LIANG ; Hai-Qing MA ; Yi-Bing CHEN ; Jian-Chuan XIA
Chinese Journal of Cancer 2010;29(7):641-648
BACKGROUND AND OBJECTIVECytokine-induced killer (CIK) cells and autologous dendritic cells-CIK (DC-CIK) cells co-cultured with autologous dendritic cells (DCs) and CIK cells are commonly used for immunotherapy recently. We compared the anti-tumor immune response of CIK cells, autologous DC-CIK cells, and semi-allogeneic DC-CIK cells to explore a more effective anti-tumor adoptive immunotherapy approach.
METHODSPeripheral monocytes were isolated from patients with renal carcinoma, lung cancer, or maxillary squamous cell carcinoma and their healthy adult children. Isolated cells were cultured and induced as DCs and CIK cells in vitro. CIK cells from patients were co-cultured with autologous DCs and DCs from their children respectively, generating DC-CIK cells and semi-allogeneic DC-CIK cells. The anti-tumor activities of autologous CIK cells, autologous DC-CIK cells, and semi-allogeneic DC-CIK cells were measured by LDH assay. Intracellular staining was used to test the secretion of cytokines. Flow cytometry was applied for detecting the phonotype changes of these three types of cells. Cell proliferation and cell apoptosis were detected by 5,6-carboxyfluorescein diacetate succinimidyl ester (CFSE) and Annexin V/PI respectively.
RESULTSCompared with autologous CIK cells and DC-CIK cells, semi-allogeneic DC-CIK cells significantly enhanced the anti-tumor activity and IFN-gamma secretion, reduced IL-4 secretion, increased the ratio of CD3(+)CD56(+) cells and CD3(+)CD8(+) cells, decreased the number of CD4(+)CD25(+) cells, promoted cell proliferation, and lessened cell apoptosis.
CONCLUSIONSSemi-allogeneic DC-CIK cells had a stronger anti-tumor effect than did autologous CIK cells and DC-CIK cells. Our results provided experimental evidence for clinical application of DC-CIK cells.
Apoptosis ; Carcinoma, Squamous Cell ; metabolism ; pathology ; Cell Line, Tumor ; Cell Proliferation ; Cells, Cultured ; Coculture Techniques ; Cytokine-Induced Killer Cells ; cytology ; immunology ; metabolism ; Cytokines ; metabolism ; Cytotoxicity, Immunologic ; Dendritic Cells ; cytology ; immunology ; metabolism ; Hep G2 Cells ; Humans ; Immunotherapy, Adoptive ; Interferon-gamma ; secretion ; Interleukin-4 ; secretion ; K562 Cells ; Kidney Neoplasms ; metabolism ; pathology ; L-Lactate Dehydrogenase ; metabolism ; Lung Neoplasms ; metabolism ; pathology ; Maxillary Neoplasms ; metabolism ; pathology
4.Effect of anti-asthma Chinese medicine Chuankezhi on the anti-tumor activity of cytokine-induced killer cells.
Jing-Jing ZHAO ; Ke PAN ; Qi-Jing WANG ; Zheng-Di XU ; De-Sheng WENG ; Jian-Jun LI ; Yong-Qiang LI ; Jian-Chuan XIA
Chinese Journal of Cancer 2013;32(10):553-560
Chuankezhi (CKZ), a new Chinese medicine, plays an important role in immunoregulation. Cytokine-induced killer (CIK) cells have been commonly used for immunotherapy in recent years. In this study, we aimed to investigate the immunoregulatory effect of CKZ on CIK cells. Peripheral blood monocytes were isolated from healthy donors, and CIK cells were generated by culturing monocytes with interferon-gamma (IFN-γ) and interleukin 2. Different concentrations of CKZ were added on day 2. After incubation for 14 days in culture, the antitumor effects of CIK cells were measured by cytotoxicity assay. Flow cytometry was used to explore the effect of CKZ on CIK cell immunophenotype, intracellular cytokine production, and apoptosis. The effect of CKZ on the antitumor activity of CIK cells in nude mice was also investigated. CKZ increased the percentage of CD3+CD56+ CIK cells but did not significantly change the percentage of CD4+, CD8+, or CD4+CD25+ CIK cells. CKZ-conditioned CIK cells showed a greater ability to kill tumor cells, as well as a higher frequency of IFN-γ and TNF-α production, compared with the CIK cells in the control group. CKZ also suppressed the apoptosis of CIK cells in vitro. Furthermore, CKZ combined with CIK cells had a stronger suppressive effect on tumor growth in vivo than the CIK, CKZ, or normal saline control groups. Our results indicate that CKZ enhances the antitumor activity of CIK cells and is a potential medicine for tumor immunotherapy.
Animals
;
Apoptosis
;
drug effects
;
CD3 Complex
;
metabolism
;
CD56 Antigen
;
metabolism
;
Cell Line, Tumor
;
drug effects
;
Cytokine-Induced Killer Cells
;
cytology
;
drug effects
;
immunology
;
Cytotoxicity, Immunologic
;
Drugs, Chinese Herbal
;
isolation & purification
;
pharmacology
;
Epimedium
;
chemistry
;
Female
;
Humans
;
Interferon-gamma
;
metabolism
;
Mice
;
Mice, Inbred BALB C
;
Mice, Nude
;
Morinda
;
chemistry
;
Neoplasm Transplantation
;
Plants, Medicinal
;
chemistry
;
Tumor Burden
;
Tumor Necrosis Factor-alpha
;
metabolism
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Safety of in vitro amplified HLA-haploidentical donor immune cell infusions for childhood malignancies.
Fei ZHANG ; Xiao-Fei SUN ; Yong-Qiang LI ; Zi-Jun ZHEN ; Hai-Xia ZHENG ; Jia ZHU ; Qi-Jing WANG ; Su-Ying LU ; Jia HE ; Juan WANG ; Ke PAN ; Rui-Qing CAI ; Yan CHEN ; De-Sheng WENG ; Fei-Fei SUN ; Jian-Chuan XIA
Chinese Journal of Cancer 2013;32(12):661-666
In vitro amplified human leukocyte antigen (HLA)-haploidentical donor immune cell infusion (HDICI) is not commonly used in children. Therefore, our study sought to evaluate its safety for treating childhood malignancies. Between September 2011 and September 2012, 12 patients with childhood malignancies underwent HDICI in Sun Yat-sen University Cancer Center. The median patient age was 5.1 years (range, 1.7-8.4 years). Of the 12 patients, 9 had high-risk neuroblastoma (NB) [7 showed complete response (CR), 1 showed partial response (PR), and 1 had progressive disease (PD) after multi-modal therapies], and 3 had Epstein-Barr virus (EBV)-positive lymphoproliferative disease (EBV-LPD). The 12 patients underwent a total of 92 HDICIs at a mean dose of 1.6×10(8) immune cells/kg body weight: 71 infusions with natural killer (NK) cells, 8 with cytokine-induced killer (CIK) cells, and 13 with cascade primed immune cells (CAPRIs); 83 infusions with immune cells from the mothers, whereas 9 with cells from the fathers. Twenty cases (21.7%) of fever, including 6 cases (6.5%) accompanied with chills and 1 (1.1%) with febrile convulsion, occurred during infusions and were alleviated after symptomatic treatments. Five cases (5.4%) of mild emotion changes were reported. No other adverse events occurred during and after the completion of HDIDIs. Neither acute nor chronic graft versus host disease (GVHD) was observed following HDICIs. After a median of 5.0 months (range, 1.0-11.5 months) of follow-up, the 2 NB patients with PR and PD developed PD during HDICIs. Of the other 7 NB patients in CR, 2 relapsed in the sixth month of HDICIs, and 5 maintained CR with disease-free survival (DFS) ranging from 4.5 to 11.5 months (median, 7.2 months). One EBV-LPD patient achieved PR, whereas 2 had stable disease (SD). Our results show that HDICI is a safe immunotherapy for childhood malignancies, thus warranting further studies.
Child
;
Child, Preschool
;
Cytokine-Induced Killer Cells
;
immunology
;
Epstein-Barr Virus Infections
;
therapy
;
Female
;
Follow-Up Studies
;
Graft vs Host Disease
;
etiology
;
Hematopoietic Stem Cell Transplantation
;
adverse effects
;
Humans
;
Immunotherapy, Adoptive
;
Infant
;
Killer Cells, Natural
;
immunology
;
Lymphoproliferative Disorders
;
therapy
;
virology
;
Male
;
Neuroblastoma
;
therapy
;
Transplantation, Homologous
;
Treatment Outcome