1.Reconstruction of Allen's type IV fingertip amputation via bilateral unequal-sized hallux osteo-onychocutaneous free flaps: A retrospective study with 5-year follow-up
Xiu-Zhong LI ; Xiu-Yun WANG ; Yi-Min ZHOU ; Da-Zhi YU ; Hua-Gang ZHANG ; Shu-Jian HOU ; Ke-Cheng LAO ; Xiao FAN
Chinese Journal of Traumatology 2024;27(6):403-409
Purpose::The reconstruction of Allen's type IV fingertip amputation is a clinical challenge. Our team designed bilateral unequal-sized hallux osteo-onychocutaneous free flaps for the long-term reconstruction of Allen's type IV fingertip amputation and conducted a retrospective study with a 5-year follow-up aims to evaluate the effects of this technique.Methods::A retrospective analysis with a 5-year follow-up including 13 patients with Allen's type IV fingertip amputation who were admitted to our hospital from January 2010 to January 2017 was conducted. The patients were treated with bilateral unequal-sized hallux osteo-onychocutaneous free flaps. The operation time, intraoperative blood loss, and complications were recorded, and the survival rate of the transplanted flaps was calculated. During the 5-year follow-up after operation, the nail growth time was recorded and the finger appearance was observed. At the last follow-up appointment, the length, width, and girth of the reconstructed fingertip and contralateral normal fingertip, range of motion of the reconstructed fingertip and contralateral normal fingertip, Semmes-Weinstein test (for the evaluation of tactile sensation), and two-point discrimination testing results were recorded. SPSS 22.0 software was used for the statistical analysis and the data are presented as mean ± SD.Results::The mean operation time was (5.62 ± 0.51) h, the mean intraoperative blood loss was (34.15 ± 3.13) mL, and the survival rate of the transplanted flaps was 100%. During the 5-year follow-up, the average nail growth time was (10.14 ± 1.98) months and the average bone union time was (3.78 ± 0.91) months. The length, width, and girth of the reconstructed fingertip were (31.52 ± 3.73) mm, (17.82 ± 1.74) mm, and (59.75 ± 3.04) mm, respectively, which did not differ from those of the contralateral normal fingertip. The range of motion of the reconstructed fingertip was (12.15 ± 2.79) degrees which is different from that of the contralateral normal fingertip. The average tactile sensation evaluated via the Semmes-Weinstein test and the average two-point discrimination test of the reconstructed fingertip were (0.39 ± 0.17) g and (7.46 ± 1.14) mm, respectively, which were not different from those of the contralateral normal fingertip. The average Maryland score of feet in the donor area was 87.66 ± 7.39, which was satisfactory.Conclusion::Bilateral unequal-sized hallux osteo-onychocutaneous free flaps are an effective method to reconstruct Allen's type IV fingertip amputations with a satisfactory appearance and good sensory function.
2.CO Laser Moxibustion for Knee Osteoarthritis: Study Protocol for A Multicenter, Double-blind, Randomized Controlled Trial.
Meng-Hu GUO ; Ling ZHAO ; Fan WU ; Jiong DU ; Chen-Huan DING ; Jing-Hua GE ; Ming T TAN ; Li-Xing LAO ; Xue-Yong SHEN ; Ke CHENG
Chinese journal of integrative medicine 2020;26(8):568-576
BACKGROUND:
Knee osteoarthritis (OA) is a major cause of disability among the older adults. Few treatments are safe and effective. Moxibustion is commonly used in treating knee OA in Chinese medicine (CM). CO Laser moxibustion device is a substitute for traditional moxibustion, which mimics the effects of traditional moxibustion. More data are needed to support its application in knee OA.
OBJECTIVE:
ObjectiveThe trial aims to assess the effect and safety of CO laser moxibustion in patients with knee osteoarthritis compared with a sham control.
METHODS:
This is a protocol for a multicenter, randomized, double-blind, placebo-controlled trial. A total of 392 participants were recruited and assigned to the CO laser moxibustion group and sham laser moxibustion group with a 1:1 ratio at 6 outpatient clinics in Shanghai, China. Participants in both groups received treatment at the affected knee(s) at the acupuncture point Dubi (ST 35) and an Ashi point. There were 3 sessions per week for 4 weeks, and an additional 20-week follow-up. Primary outcomes were changes in the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain scores at week 4. Secondary outcomes were WOMAC function score, stiffness score and overall score, VAS pain, Short-Form heath survey (SF-36), and patients' global assessment. The serum levels of cytokines involved in progress of knee OA were explored. Safety was assessed during the whole trial. Masking effectiveness was assessed by both participants and treatment providers.This is a protocol for a multicenter, randomized, double-blind, placebo-controlled trial. A total of 392 participants were recruited and assigned to the CO laser moxibustion group and sham laser moxibustion group with a 1:1 ratio at 6 outpatient clinics in Shanghai, China. Participants in both groups received treatment at the affected knee(s) at the acupuncture point Dubi (ST 35) and an Ashi point. There were 3 sessions per week for 4 weeks, and an additional 20-week follow-up. Primary outcomes were changes in the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain scores at week 4. Secondary outcomes were WOMAC function score, stiffness score and overall score, VAS pain, Short-Form heath survey (SF-36), and patients' global assessment. The serum levels of cytokines involved in progress of knee OA were explored. Safety was assessed during the whole trial. Masking effectiveness was assessed by both participants and treatment providers.
DISCUSSION
CO laser moxibustion device, designed as a substitute for CM moxibustion, is easy to use and control with no choking smoke and smell, and is a plausible method for double-blind research. This study would provide rigorous evidence for the effect and safety of CO laser moxibustion in treating knee OA (Trial registration No.: ISRCTN15030019).