1.Attention to the research about congenital cataract candidate gene
Chinese Journal of Experimental Ophthalmology 2014;32(6):481-484
Congenital cataracts is the leading cause of visual disability in children worldwide.With the evolution of molecular biological technique,the researches of inherited congenital cataract mainly focus on localization and fuction characterization of the disease-associated gene,including crystallin,connexin,major intrinsic protein gene,etc.And great progress has been made for such genes in eye development,age-related cataract,epigenetics study.Thus,great attention must be paid to the functional research about congenital cataract candidate gene.
2.The trend of intraocular lens design: aspheric or spherical?
Ophthalmology in China 1993;0(01):-
Spherical aberration is the major cause which affects the functional vision of the patients implanted with spherical intraocular lenses (IOLs). Aspheric IOLs are designed to eliminate the aberration like the nature lens, thus they can produce better visual quality. If it is feasible to customize IOL design to the individual cataract patient, aspheric IOLs may substitute the traditional spherical IOLs and become the trend of IOLs.
3.Decalcified bone matrix and bone cement compound at various proportions in repairing rabbit femoral defect
Chinese Journal of Tissue Engineering Research 2007;0(21):-
BACKGROUND:BACKGROUND:Present studies have shown that bone cement have less osteoinduction and slow degradation in the body,so the effect of alone application is not satisfactory. Therefore,people have modified them,hoping to research a new materials that can overcome all shortcomings above-mentioned. OBJECTIVE:To investigate the ability of decalcified bone matrix (DBM) and acrylic bone cement (ABC) compound in filling and repairing bone defect,and to determine the best component proportion of the composition. DESIGN,TIME AND SETTING:Randomized controlled animal experiments were performed at the Experimental Animal Center,Chongqing Medical University from May to September 2008. MATERIALS:ABC and DBM were prepared into compound material at various proportions (2:8,3:7,4:6,5:5,6:4). METHODS:The animal models of bilateral femur bone defects and fillers were established in the New Zealand White rabbits. The complex material was implanted on the bone defect; the ABC was used as blank control group. MAIN OUTCOME MEASURES:The complex and alone materials were examined by biomechanics and scan electron microscopes. Gross observation,histopathological and X-ray test were used at 4,8,12 weeks after operation respectively to observe the repaired and filled status of bone defect. RESULTS:DBM composite quality of the scope of 3:7 -6:4,the composite materials that existed in more cracks more than 100 ?m,when the DBM was less than 3:7,the material inside the aperture and the majority of material was similar to ABC,mass ratio greater than 6:4 when the DBM and the ABC could not effectively together solidification. When the mass ratio was increased,which matrix particles of demineralized bone and ABC,the compressive ultimate strength of composite materials was less than pure ABC (P
5.Clinical significance of APACHE Ⅱ score in patients with acute myocardial infarction
Jun KE ; Jianhui YAO ; Kaixuan FENG
Clinical Medicine of China 2014;30(10):1024-1026
Objective To explore the clinical significance of APACHE Ⅱ score on risk stratification in patients with acute myocardial infarction.Methods One hundred and forty-two patients with acute myocardial infarction were included in the study who were admitted to hospital consecutively from Jan.2011 to Dec.2012.High risk group and low risk group were divided by the APACHE Ⅱ score.Some clinical variables at the first 24 h after admitted to hospital and occurring during the following 1 year were recorded Results The age in high risk group was 78.9 ±8.1,significantly higher than that in low risk group (65.8 ± 10.2;t =6.835,P < 0.001).The cases with Killip Ⅲ and Ⅳ in high risk group were 10(29.4%) and 2(1.8%),lower than in low risk group (6 (1.8%) and 0 (0%) ; x2 =21.950,15.777 ; P < 0.005).The level of creatine kinase-MB (CK-MB) and cardiac troponin Ⅰ in high risk group were (147.7 ±21.5) U/L and (105.5 ± 17.6) U/L,higher than in low risk group((105.5 ± 17.6) U/L,(42.9 ± 6.3) U/L; t =11.541,5.785 ; P < 0.001).The incidence of severe cardiac events(malignant arrhythmia,heart failure,non fatal myocardial infarction and death from any cause in high risk group were 58.8% (20/34),47.0% (16/34),17.6% (6/34) and 17.6% (6/34),higher than in low risk group (29.6% (32/108),3.7% (4/108),6.4% (7/108) and 6.4% (7/108) ; x2 =8.274,36.665,3.876 and 3.876 ; P < 0.05).Conclusion APACHE Ⅱ score is likely to be a simple and practical tool for risk stratification in patients with acute myocardial infarction.
6.Autoimmune pancreatitis: report of a case.
Ke SUN ; Hong-tian YAO ; Mei KONG ; Xiao-dong TENG
Chinese Journal of Pathology 2012;41(2):140-141
Autoimmune Diseases
;
diagnosis
;
immunology
;
pathology
;
surgery
;
Humans
;
Immunoglobulin G
;
blood
;
Magnetic Resonance Imaging
;
Male
;
Middle Aged
;
Pancreatectomy
;
Pancreatitis
;
diagnosis
;
immunology
;
pathology
;
surgery
7.Investigation on an acute hydrogen arsenide poisoning incident in an electrolytic zinc factory in Guizhou Province.
Hong LI ; Dan-cheng YAO ; Ke-feng CHEN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2008;26(3):160-160
Accidents, Occupational
;
Acute Disease
;
Adolescent
;
Adult
;
Arsenic Poisoning
;
Chemical Industry
;
China
;
Female
;
Humans
;
Male
;
Middle Aged
;
Young Adult
;
Zinc
8.Comparison of ocular anterior segment parameters measured by three kinds of biometric measuring methods in myopic eyes
Hongying, JIN ; Ke, YAO ; Yabo, YANG ; Xinhua, DU ; Peijin, QIU
Chinese Journal of Experimental Ophthalmology 2014;32(12):1097-1101
Background It is essential to measure and assess the parameters of ocular anterior segment for refractive surgery in myopic eyes.Some different imaging devices can be used for biometric measurement of ocular anterior segment,but which is more accurate and convenient is still under investigation.Objective This study was to compare the anterior segment parameters in myopic eyes measured by anterior segment optical coherence tomography (AS-OCT),Orbscan topography and ultrasonic pachymetry (US).Methods One hundred and forty eyes of 70 myopic subjects with the diopter of-0.75 to-10.25 D,who intended to receive corneal refractive surgery in the Second Affiliated Hospital of Zhejiang University School of Medicine from November 2011 to May 2012,were retrospectively analyzed.Central corneal thickness (CCT) was measured using AS-OCT,Orbscan Ⅱ and US,respectively,and anterior chamber depth (ACD) was measured by AS-OCT and Orbscan Ⅱ,and the angle to angle (ATA) distance and corneal white-to-white corneal distance (WTW) were measured by AS-OCT and Orbscan Ⅱ,respectively.The parameters from different apparatuses were statistically compared.Results The mean CCT were (516.57±30.25) μm in AS-OCT,(523.68±31.87) μm in US and (514.69±38.40) μm in Orbscan Ⅱ,without significant difference among them (F =2.775,P =0.063).Then the patients were divided into three groups based on the US measurement of CCT (<500 μm group,500-569 μm group,and ≥ 570 μm group).In the <500 μm group,there was a significant difference in the CCT among the three methods (F =22.236,P =0.000),significant differences were found between AS-OCT and Orbscan Ⅱ,or Orbscan Ⅱ and US(both at P<0.05).In the 500-569 μm group,there was no significant difference in the CCT among the three methods (F =3.011,P =0.051).In the ≥ 570 μm group,there was a significant difference in the CCT among the three methods (F =4.133,P =0.021),a significant difference was found between AS-OCT and US(P<0.05),but there was no significant difference between AS-OCT and Orbscan Ⅱ (P>0.05).The ACD values measured by AS-OCT was (3.83±0.21) mm,which was higher than (3.75 ± 0.21) mm by Orbscan Ⅱ,with a significant difference between them (t =-8.520,P =0.000).In addition,the ATA value by AS-OCT (12.43 mm±0.74 mm) was higher than the WTW value (11.42 mm±0.33 mm) by OrbscanⅡ,with a significant difference between them(t=-18.088,P=0.000).Conclusions AS-OCT,US and Orbscan Ⅱ can offer accurate CCT value,and they can provide references to one another before refractive surgery.However,the ACD,ATA and WTW values by AS-OCT and Orbscan]Ⅱ have large differences.
9.Inhibitory effect of endothelin receptor antagonist on increased vascular endothelial growth factor level of retina in diabetic rats
ke-bo, CAI ; yao-hua, SHENG ; chang-bin, QIU
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(04):-
Objective To observe the inhibitory effect of endothelin receptor antagonist on increased vascular endothelial growth factor(VEGF) level of retina in diabetic rats. Methods Male Wistar rats were randomly divided into three groups: normal control group,diabetic group(diabetes without treatment) and treated group(diabetes treated with endothelin receptor antagonist).The rats were killed after 24 weeks.Levels of VEGF in retina of rats were detected by ELISA. Results Levels of VEGF were significantly lower in treated group than diabetic group(P
10.Effect of liposomal transfection of cyclin D1 antisense oligodeoxynucleotide on A549 cell proliferation and apoptosis
Li JIANG ; Jiaxin MIN ; Xuechang LI ; Ke YAO
Journal of Third Military Medical University 2003;0(10):-
Objective To explore the effect of liposomal transfection of cyclin D1 antisense oligodeoxynucleotide (ASON) on A549 cell proliferation and apoptosis. Methods By liposomal transfection technique, cyclin D1 ASON was co-cultured with A549 cells. The cell growth curve was determined by MTT assay. The protein and mRNA of cyclin D1 were measured by FACS and RT-PCR. Results In the cyclin D1 ASON liposomal transfection group, the proliferation of A549 cells was significantly inhibited as compared to that in cyclin D1 ASON group (P