1.CAD/CAM splint based on soft tissue 3D simulation for treatment of facial asymmetry.
Kazuhiro TOMINAGA ; Manabu HABU ; Hiroki TSURUSHIMA ; Osamu TAKAHASHI ; Izumi YOSHIOKA
Maxillofacial Plastic and Reconstructive Surgery 2016;38(1):4-
BACKGROUND: Most cases of facial asymmetry involve yaw deformity, and determination of the yaw correction level is very difficult. METHODS: We use three-dimensional soft tissue simulation to determine the yaw correction level. This three-dimensional simulation is based on the addition of cephalometric prediction to gradual yaw correction. Optimal yaw correction is determined visually, and an intermediate splint is fabricated with computer-aided design and computer-aided manufacturing. Application of positioning devices and the performance of horseshoe osteotomy are advisable. RESULTS: With this procedure, accurate repositioning of jaws was confirmed and patients obtained fairly good facial contour. CONCLUSIONS: This procedure is a promising method for a widespread, predictable treatment of facial asymmetry.
Computer-Aided Design
;
Congenital Abnormalities
;
Facial Asymmetry*
;
Humans
;
Jaw
;
Methods
;
Orthognathic Surgery
;
Osteotomy
;
Splints*
2.Successful Treatment for Persistent Air Leaks with an Autologous “Blood Patch” Pleurodesis after the Norwood Procedure
Hideki Tatewaki ; Toshihide Nakano ; Kazuhiro Hinokiyama ; Noriyoshi Ebuoka ; Hidekazu Matsumae ; Daisuke Machida ; Takahiro Shoujima ; Jin Ikarashi ; Ryuji Tominaga ; Hideaki Kado
Japanese Journal of Cardiovascular Surgery 2014;43(6):340-343
Persistent massive air leak after pediatric cardiac surgery is a rare and possibly life-threatening complication which is difficult to treat. We report a 3-month-old boy with hypoplastic left heart syndrome that underwent Glenn take-down, suffered from pulmonary hemorrhage during surgery and needed mechanical ventilation with high airway pressure that caused bilateral pneumothorax. After pulmonary hemorrhage improved, pneumothorax with persistent air leaks did not resolve under prolonged chest tubes. This patient underwent an autologous “blood patch” pleurodesis on postoperative day 32. The procedure was repeated a second time 48 h after the application of the first blood patch. After these procedures, air leaks dramatically ceased. The patient was successfully weaned from the ventilator on postoperative day 70. Pleurodesis with an autologous blood patch is a safe and an effective technique for the treatment of persistent air leaks, even for a 3-month-old boy with hypoplastic left heart syndrome.
3.Combined Method of Antegrade and Retrograde Cardioplegia in Double Valve Replacement.
Kazuhiro KURISU ; Kazuhiko KINOSHITA ; Masato SAKAMOTO ; Yoshikazu TSURUHARA ; Fumio FUKUMURA ; Atsuhiro NAKASHIMA ; Yasuo KANEGAE ; Manabu HISAHARA ; Ryuji TOMINAGA ; Yoshito KAWACHI ; Hisataka YASUI ; Kouichi TOKUNAGA
Japanese Journal of Cardiovascular Surgery 1992;21(2):159-163
The combined method of antegrade and retrograde administration of cardioplegic solution has been established for coronary bypass surgery. We applied this technique in patients undergoing aortic and mitral valve surgery. Between January 1989 and December 1990, 28 patients underwent both aortic and mitral valve replacements. To compare the myocardial protective effect according to the method of cardioplegic administration, they were divided into two groups; Ante group (antegrade, n=15) and Retro group (combined method of antegrade and retrograde, n=13). Aortic occlusion time and cardiopulmonary bypass time were shorter in Retro group. The mean interval of each cardioplegic administration was significantly shorter in Retro group (Ante group, 29.2±4.8min vs Retro group, 24.0±3.8min; p<0.01). These results suggest that retrograde cardioplegia method never disturbs ongoing operation during each delivery while antegrade method often does. Serum CPK-MB at 6hr of reperfusion tended to be less in Retro group (Ante group, 120±80IU/l vs Retro group, 78±50IU/l; p=0.09). The results of postoperative cardiac functions were the same in both groups. We therefore believe that this method is an optimal strategy even in patients with valvular heart disease.