1.Continuation of Enteral Nutrition and Relief from Vomiting by Administration of a New Formula: a Case Report.
Tetsuro AKASHI ; Kazuhide MATSUMOTO ; Risa HASHIMOTO
Clinical Nutrition Research 2017;6(4):306-309
Gastro-esophageal reflux (GER) is a common and serious complication in patients receiving enteral nutrition, making continuation of enteral nutrition difficult. Semi-solid enteral nutrients were developed to prevent feeding-related GER. Semi-solid enteral nutrients have high viscosity and, therefore, are typically administered through a large-diameter percutaneous endoscopic gastrostomy (PEG) tube. Recently, a new formula (Mermed®, Mermed Plus®) was introduced that uses alginate, which behaves like a gelatin in acidic conditions. This formula improved GER during enteral feedings. Our case report shows that this new formula enables the continuation of enteral nutrition via a nasogastric tube (NGT) in patients with difficulty tolerating enteral nutrition secondary to vomiting. An 86-year-old woman with an atherothrombotic cerebral infarction vomited during tube feeding, resulting in aspiration pneumonia. After 1 week, we introduced a viscosity regulator and restarted enteral feeding using a 100 mL liquid diet, but vomiting persisted. Because of the continued difficulty in tolerating enteral nutrition, the patient was transferred to our hospital. From hospital day 4, Mermed Plus® (300 mL/225 kcal, administered for 1 hour, 3 times a day) was started, eventually increasing to 535 mL/400 kcal at hospital day 5. After this, vomiting ceased. Mermed Plus® was easily administered via NGT, and its effects were immediate. This treatment appeared to improve the patient's quality of life while reducing the burden on medical staff.
Aged, 80 and over
;
Alginates
;
Cerebral Infarction
;
Diet
;
Enteral Nutrition*
;
Female
;
Gastroesophageal Reflux
;
Gastrostomy
;
Gelatin
;
Humans
;
Medical Staff
;
Pneumonia, Aspiration
;
Quality of Life
;
Viscosity
;
Vomiting*
2.Continuation of Enteral Nutrition and Relief from Vomiting by Administration of a New Formula: a Case Report.
Tetsuro AKASHI ; Kazuhide MATSUMOTO ; Risa HASHIMOTO
Clinical Nutrition Research 2017;6(4):306-309
Gastro-esophageal reflux (GER) is a common and serious complication in patients receiving enteral nutrition, making continuation of enteral nutrition difficult. Semi-solid enteral nutrients were developed to prevent feeding-related GER. Semi-solid enteral nutrients have high viscosity and, therefore, are typically administered through a large-diameter percutaneous endoscopic gastrostomy (PEG) tube. Recently, a new formula (Mermed®, Mermed Plus®) was introduced that uses alginate, which behaves like a gelatin in acidic conditions. This formula improved GER during enteral feedings. Our case report shows that this new formula enables the continuation of enteral nutrition via a nasogastric tube (NGT) in patients with difficulty tolerating enteral nutrition secondary to vomiting. An 86-year-old woman with an atherothrombotic cerebral infarction vomited during tube feeding, resulting in aspiration pneumonia. After 1 week, we introduced a viscosity regulator and restarted enteral feeding using a 100 mL liquid diet, but vomiting persisted. Because of the continued difficulty in tolerating enteral nutrition, the patient was transferred to our hospital. From hospital day 4, Mermed Plus® (300 mL/225 kcal, administered for 1 hour, 3 times a day) was started, eventually increasing to 535 mL/400 kcal at hospital day 5. After this, vomiting ceased. Mermed Plus® was easily administered via NGT, and its effects were immediate. This treatment appeared to improve the patient's quality of life while reducing the burden on medical staff.
Aged, 80 and over
;
Alginates
;
Cerebral Infarction
;
Diet
;
Enteral Nutrition*
;
Female
;
Gastroesophageal Reflux
;
Gastrostomy
;
Gelatin
;
Humans
;
Medical Staff
;
Pneumonia, Aspiration
;
Quality of Life
;
Viscosity
;
Vomiting*
3.Puncture angle on an endoscopic ultrasound image is independently associated with unsuccessful guidewire manipulation of endoscopic ultrasound-guided hepaticogastrostomy: a retrospective study in Japan
Akihisa OHNO ; Nao FUJIMORI ; Toyoma KAKU ; Kazuhide MATSUMOTO ; Masatoshi MURAKAMI ; Katsuhito TERAMATSU ; Keijiro UEDA ; Masayuki HIJIOKA ; Akira ASO ; Yoshihiro OGAWA
Clinical Endoscopy 2024;57(5):656-665
Background/Aims:
Although endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is performed globally, the procedure remains challenging. Guidewire manipulation is the most difficult step, and there are few reports on the factors associated with unsuccessful guidewire manipulation. This study aimed to assess the significance of the puncture angle on EUS images and identify the most effective guidewire rescue method for patients with unsuccessful guidewire manipulation.
Methods:
We retrospectively enrolled 115 patients who underwent EUS-HGS between May 2016 and April 2022 at two centers. The puncture angle between the needle and the intrahepatic bile duct was measured through EUS movie records.
Results:
Guidewire manipulation was unsuccessful in 28 patients. Receiver operating characteristic (ROC) curves identified an optimal puncture angle cutoff value of 85° (cutoff value, 85°; area under the ROC curve, 0.826; sensitivity, 85.7%; specificity, 81.6%). Multivariate analysis demonstrated that a puncture angle <85° was a significant risk factor for unsuccessful guidewire manipulation (odds ratio, 19.8; 95% confidence interval, 6.42–61.5; p<0.001). Among the 28 unsuccessful cases, 24 patients (85.7%) achieved successful guidewire manipulation using various rescue methods.
Conclusions
The puncture angle observed on EUS is crucial for guidewire manipulation. A puncture angle of <85° was associated with unsuccessful guidewire manipulation.
4.Puncture angle on an endoscopic ultrasound image is independently associated with unsuccessful guidewire manipulation of endoscopic ultrasound-guided hepaticogastrostomy: a retrospective study in Japan
Akihisa OHNO ; Nao FUJIMORI ; Toyoma KAKU ; Kazuhide MATSUMOTO ; Masatoshi MURAKAMI ; Katsuhito TERAMATSU ; Keijiro UEDA ; Masayuki HIJIOKA ; Akira ASO ; Yoshihiro OGAWA
Clinical Endoscopy 2024;57(5):656-665
Background/Aims:
Although endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is performed globally, the procedure remains challenging. Guidewire manipulation is the most difficult step, and there are few reports on the factors associated with unsuccessful guidewire manipulation. This study aimed to assess the significance of the puncture angle on EUS images and identify the most effective guidewire rescue method for patients with unsuccessful guidewire manipulation.
Methods:
We retrospectively enrolled 115 patients who underwent EUS-HGS between May 2016 and April 2022 at two centers. The puncture angle between the needle and the intrahepatic bile duct was measured through EUS movie records.
Results:
Guidewire manipulation was unsuccessful in 28 patients. Receiver operating characteristic (ROC) curves identified an optimal puncture angle cutoff value of 85° (cutoff value, 85°; area under the ROC curve, 0.826; sensitivity, 85.7%; specificity, 81.6%). Multivariate analysis demonstrated that a puncture angle <85° was a significant risk factor for unsuccessful guidewire manipulation (odds ratio, 19.8; 95% confidence interval, 6.42–61.5; p<0.001). Among the 28 unsuccessful cases, 24 patients (85.7%) achieved successful guidewire manipulation using various rescue methods.
Conclusions
The puncture angle observed on EUS is crucial for guidewire manipulation. A puncture angle of <85° was associated with unsuccessful guidewire manipulation.
5.Puncture angle on an endoscopic ultrasound image is independently associated with unsuccessful guidewire manipulation of endoscopic ultrasound-guided hepaticogastrostomy: a retrospective study in Japan
Akihisa OHNO ; Nao FUJIMORI ; Toyoma KAKU ; Kazuhide MATSUMOTO ; Masatoshi MURAKAMI ; Katsuhito TERAMATSU ; Keijiro UEDA ; Masayuki HIJIOKA ; Akira ASO ; Yoshihiro OGAWA
Clinical Endoscopy 2024;57(5):656-665
Background/Aims:
Although endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is performed globally, the procedure remains challenging. Guidewire manipulation is the most difficult step, and there are few reports on the factors associated with unsuccessful guidewire manipulation. This study aimed to assess the significance of the puncture angle on EUS images and identify the most effective guidewire rescue method for patients with unsuccessful guidewire manipulation.
Methods:
We retrospectively enrolled 115 patients who underwent EUS-HGS between May 2016 and April 2022 at two centers. The puncture angle between the needle and the intrahepatic bile duct was measured through EUS movie records.
Results:
Guidewire manipulation was unsuccessful in 28 patients. Receiver operating characteristic (ROC) curves identified an optimal puncture angle cutoff value of 85° (cutoff value, 85°; area under the ROC curve, 0.826; sensitivity, 85.7%; specificity, 81.6%). Multivariate analysis demonstrated that a puncture angle <85° was a significant risk factor for unsuccessful guidewire manipulation (odds ratio, 19.8; 95% confidence interval, 6.42–61.5; p<0.001). Among the 28 unsuccessful cases, 24 patients (85.7%) achieved successful guidewire manipulation using various rescue methods.
Conclusions
The puncture angle observed on EUS is crucial for guidewire manipulation. A puncture angle of <85° was associated with unsuccessful guidewire manipulation.
6.Puncture angle on an endoscopic ultrasound image is independently associated with unsuccessful guidewire manipulation of endoscopic ultrasound-guided hepaticogastrostomy: a retrospective study in Japan
Akihisa OHNO ; Nao FUJIMORI ; Toyoma KAKU ; Kazuhide MATSUMOTO ; Masatoshi MURAKAMI ; Katsuhito TERAMATSU ; Keijiro UEDA ; Masayuki HIJIOKA ; Akira ASO ; Yoshihiro OGAWA
Clinical Endoscopy 2024;57(5):656-665
Background/Aims:
Although endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is performed globally, the procedure remains challenging. Guidewire manipulation is the most difficult step, and there are few reports on the factors associated with unsuccessful guidewire manipulation. This study aimed to assess the significance of the puncture angle on EUS images and identify the most effective guidewire rescue method for patients with unsuccessful guidewire manipulation.
Methods:
We retrospectively enrolled 115 patients who underwent EUS-HGS between May 2016 and April 2022 at two centers. The puncture angle between the needle and the intrahepatic bile duct was measured through EUS movie records.
Results:
Guidewire manipulation was unsuccessful in 28 patients. Receiver operating characteristic (ROC) curves identified an optimal puncture angle cutoff value of 85° (cutoff value, 85°; area under the ROC curve, 0.826; sensitivity, 85.7%; specificity, 81.6%). Multivariate analysis demonstrated that a puncture angle <85° was a significant risk factor for unsuccessful guidewire manipulation (odds ratio, 19.8; 95% confidence interval, 6.42–61.5; p<0.001). Among the 28 unsuccessful cases, 24 patients (85.7%) achieved successful guidewire manipulation using various rescue methods.
Conclusions
The puncture angle observed on EUS is crucial for guidewire manipulation. A puncture angle of <85° was associated with unsuccessful guidewire manipulation.
7.Diffusion Tensor Imaging of the Spinal Canal in Quantitative Assessment of Patients with Lumbar Spinal Canal Stenosis
Masaki NORIMOTO ; Yawara EGUCHI ; Hirohito KANAMOTO ; Yasuhiro OIKAWA ; Koji MATSUMOTO ; Yoshitada MASUDA ; Takeo FURUYA ; Sumihisa ORITA ; Kazuhide INAGE ; Satoshi MAKI ; Yasuhiro SHIGA ; Hideyuki KINOSHITA ; Koki ABE ; Masahiro INOUE ; Tomotaka UMIMURA ; Takashi SATO ; Masashi SATO ; Masahiro SUZUKI ; Keigo ENOMOTO ; Seiji OHTORI
Asian Spine Journal 2021;15(2):207-215
Methods:
Study participants comprised five healthy volunteers (mean age, 27.2 years) and 27 patients with LSS (mean age, 58.4 years) who were individually assessed using 3.0 Tesla magnetic resonance imaging. Intraspinal ADC and FA values of 10 intervertebral discs from healthy volunteers and 52 intervertebral discs from LSS patients were measured. Also, intraspinal canal area, Schizas classification (A: normal, B: mild stenosis, C: severe stenosis) and correlations with symptoms were investigated. Clinical symptoms were checked for the presence of low back pain (LBP), intermittent claudication (IMC), and bladder and bowel dysfunction (BBD).
Results:
Compared to healthy individuals, LSS patients had significantly lower ADC (
8.Diffusion Tensor Imaging of the Spinal Canal in Quantitative Assessment of Patients with Lumbar Spinal Canal Stenosis
Masaki NORIMOTO ; Yawara EGUCHI ; Hirohito KANAMOTO ; Yasuhiro OIKAWA ; Koji MATSUMOTO ; Yoshitada MASUDA ; Takeo FURUYA ; Sumihisa ORITA ; Kazuhide INAGE ; Satoshi MAKI ; Yasuhiro SHIGA ; Hideyuki KINOSHITA ; Koki ABE ; Masahiro INOUE ; Tomotaka UMIMURA ; Takashi SATO ; Masashi SATO ; Masahiro SUZUKI ; Keigo ENOMOTO ; Seiji OHTORI
Asian Spine Journal 2021;15(2):207-215
Methods:
Study participants comprised five healthy volunteers (mean age, 27.2 years) and 27 patients with LSS (mean age, 58.4 years) who were individually assessed using 3.0 Tesla magnetic resonance imaging. Intraspinal ADC and FA values of 10 intervertebral discs from healthy volunteers and 52 intervertebral discs from LSS patients were measured. Also, intraspinal canal area, Schizas classification (A: normal, B: mild stenosis, C: severe stenosis) and correlations with symptoms were investigated. Clinical symptoms were checked for the presence of low back pain (LBP), intermittent claudication (IMC), and bladder and bowel dysfunction (BBD).
Results:
Compared to healthy individuals, LSS patients had significantly lower ADC (
9.Evaluating Spinal Canal Lesions Using Apparent Diffusion Coefficient Maps with Diffusion-Weighted Imaging
Hirohito KANAMOTO ; Masaki NORIMOTO ; Yawara EGUCHI ; Yasuhiro OIKAWA ; Sumihisa ORITA ; Kazuhide INAGE ; Koki ABE ; Masahiro INOUE ; Hideyuki KINOSHITA ; Tomotaka UMIMURA ; Koji MATSUMOTO ; Yoshitada MASUDA ; Takeo FURUYA ; Masao KODA ; Yasuchika AOKI ; Atsuya WATANABE ; Kazuhisa TAKAHASHI ; Seiji OHTORI
Asian Spine Journal 2020;14(3):312-319
Methods:
We performed 3T MRI in 10 healthy volunteers and 13 patients with LSS. The ADC values in the spinal canal were evaluated at 46 vertebrae (L4/5 and L5/S1 for each participant), and the reduced and conventional fields of view were compared.
Results:
The ADC values were 2.72±0.12 at L4/5 in healthy volunteers, 2.76±0.19 at L5/S1 in healthy volunteers, 1.77±0.58 at L4/5 in patients with LSS, and 2.35±0.29 at L5/S1 in patients with LSS. The ADC value at L4/5 in patients with LSS was significantly lower than that at L5/S1 in patients with LSS and that at L4/5 and L5/S1 in healthy volunteers (p <0.05). With an ADC cutoff value of 2.46 to identify LSS, this approach provided an area under the curve of 0.81, sensitivity of 0.92, and specificity of 0.76 (p <0.05).
Conclusions
Preoperative examination using ADC maps permits visualization and quantification of spinal canal lesions, thus proving the utility of ADC maps in the selection of decompression surgery for LSS.