1.A Case of Successful Repair with Aortic Tailoring for Chronic Type B Aortic Dissection.
Katsuhiko Matsuyama ; Yuichi Ueda ; Hitoshi Ogino ; Takaaki Sugita ; Tetsuro Sakai ; Yutaka Sakakibara ; Keiji Matsubayashi ; Takuya Nomoto
Japanese Journal of Cardiovascular Surgery 1998;27(4):260-262
A 64-year-old woman with dyspnea on exertion was referred to our hospital. CT revealed type B aortic dissection with 7cm of aneurysm including a thrombus in the false lumen at the distal aortic arch. Four intimal tears at the distal aortic arch were closed directly during hypothermic circulatory arrest, and the descending thoracic aorta was tailored without a prosthetic graft after fixation of the dissecting adventitia to the intima at the distal portion of the false lumen. The postoperative course was uneventful and this patient was discharged on the 22nd postoperative day. Three years after surgery, the postoperative CT revealed no evidence of dilatation of the descending thoracic aorta as far as the abdominal aorta although the dissection of thoracoabdominal aorta remained. This technique is effective as an surgical option for chronic type B aortic dissection to minimize operative stress and complications.
2.A Case of Ruptured Cryopreserved Homograft 7 Months after Implantation
Yosuke Inoue ; Ryoshi Maruyama ; Yukio Hasegawa ; Eiichiro Hata ; Akira Yamada ; Katsuhiko Nakanishi ; Keisuke Sakai
Japanese Journal of Cardiovascular Surgery 2013;42(2):128-131
Infectious abdominal aortic aneurysm is a relatively rare disease, and there is no consensus regarding its surgical treatment. Medical infectious control should be concerned comparison with surgical treatment if there is sepsis, however we sometimes have no other choice but emergency operation for uncontrollable cases. In many reports, cryopreserved homografts were used as in-situ alternative grafts for infectious aortic aneurysms because they had some merits such as anti-infectious effects, suitability and so on. However the number of in-situ cryopreserved homograft replacement cases are few, and the long term result is unclear. We encountered a ruptured cropreserved homograft case 7 months after urgent in-situ cryopreserved homograft replacement. We report the case and refer to the relevans literature.
3.A Case of Early Limb Stenosis after Endovascular Abdominal Aneurysm Repair with the Endurant Stent Graft System
Tsunehisa Yamamoto ; Katsuhiko Oka ; Osamu Sakai ; Hidetake Kawajiri ; Sachiko Yamazaki ; Taiji Watanabe ; Keiichi Kanda ; Hitoshi Yaku
Japanese Journal of Cardiovascular Surgery 2015;44(5):283-287
An 81-year-old man who had a saccular abdominal aortic aneurysm (AAA) with a narrow terminal aorta underwent endovascular aortic aneurysm repair (EVAR) with the Medtronic Endurant® stent graft system. After 4 days, computed tomography (CT) showed stenosis of the stent graft left limb, which was pressed flat against the right limb at the narrow terminal aorta. We performed re-intervention to dilate the narrow terminal aorta and bilateral limbs with kissing stenting using Express Vascular LD® (Boston Scientific). After operation his ankle brachial pressure index rose from 0.88 to 0.99 and there was no evidence of stenotic limbs at CT image. We need to be careful about the stenotic limb after EVAR with Medtronic Endurant stentgraft system for AAA with a narrow terminal aorta.
4.Three Cases of Infected Abdominal Aortic Aneurysm and In-Situ Repacement of the Affected Segment with a Prosthesis or Cryopreserved Arterial Homograft
Mayuko Uehara ; Ryushi Maruyama ; Akira Yamada ; Katsuhiko Nakanishi ; Yoshihiko Kurimoto ; Fumiyuki Okamoto ; Keisuke Sakai ; Tetuya Higami
Japanese Journal of Cardiovascular Surgery 2010;39(2):90-93
We encountered three cases of infra-renal infected abdominal aortic aneurysm in 2007 and 2008. Preoperative blood culture was positive in two of the three patients. All of the patients presented with fever of unknown origin. We replaced the affected segment of the abdominal aorta with a synthetic graft in 1 patient, and with a cryopreserved arterial homograft in the remaining 2 patients. An infected abdominal aortic aneurysm is a life-threatening condition. Diagnosis is often difficult, and emergency surgery may be necessitated by rupture of the aneurysm. Our experience suggests that computed tomography is effective for the diagnosis of infected aneurysms. The most effective surgical technique consists of complete resection of the aneurysm, in-situ replacement of the affected aortic segment with a synthetic graft or homograft, and omental coverage.
5.Cerebral Embolism Following Attempted Balloon Occlusion of a Ruptured Abdominal Aortic Aneurysm.
Takafumi Tahata ; Shigehito Miki ; Yuichi Ueda ; Hitoshi Ogino ; Koichi Morioka ; Tetsuro Sakai ; Katsuhiko Matsuyama ; Keiji Matsubayashi ; Takuya Nomoto
Japanese Journal of Cardiovascular Surgery 1996;25(5):337-339
The case presented is a 76-year-old woman with a ruptured abdominal aortic aneurysm. We tried to pass a Fogarty balloon catheter from the left subclavian artery for proximal occlusion of the ruptured aneurysm but failed to inset the balloon into the descending aorta. Although the aneurysm was safely replaced with a gelatine coated dacron graft, she developed cerebral embolism and never regained consciousness and died two months later. Balloon insertion through the subclavian artery may cause complication through dislodgement of atheromatous plaque and may induce cerebral embolism.
6.Quercetin Enhances Tumorigenicity Induced by N-Ethyl-N'-Nitro-N-Nitrosoguanidine in the Duodenum of Mice*
Yoshizumi MATSUKAWA ; Hoyoku NISHINO ; Mitsunori YOSHIDA ; Hiroyuki SUGIHARA ; Kanade KATSURA ; Tetsurou TAKAMATSU ; Junichi OKUZUMI ; Katsuhiko MATSUMOTO ; Fumiko SATO-NISHIMORI ; Toshiyuki SAKAI
Environmental Health and Preventive Medicine 2001;6(4):235-239
Quercetin, a flavonoid, widely distributed in many fruits and vegetables, is well known to have an anti-tumor effect despite its mutagenicity. In this study, we examined the effect of dietary quercetin on duodenum-tumorigenicity of mice induced by a chemical carcinogen, N-ethyl-N'-nitro-N-nitrosoguanidine (ENNG). Eight-week-old male C57BL/6 mice were divided into 4 groups; ENNG without quercetin (group A), ENNG with 0.2% quercetin (group B), ENNG with 2% quercetin (group C), and 2% quercetin without ENNG (group D). ENNG was given in drinking water for the first 4 weeks, and thereafter quercetin was given in a mixed diet. At week 20, the average number of duodenal tumors per mouse was significantly higher in group C (mean±SE, 7.26±1.75, p<0.05) than in group A (2.32±0.31). The size of the duodenal tumors increased significantly in group B (1.79±0.09 mm, p<0.001) compared with group A (1.43±0.09 mm). In contrast, no duodenal tumor was induced in group D. The present findings suggest that excessive intake of quercetin occasionally is a risk factor for carcinogenesis of some specific organs such as the upper intestine.
Quercetin
;
Upper Case En
;
ENNG
;
week
;
Laboratory mice
7.Quercetin enhances tumorigenicity induced by N-ethyl-N'-nitro-N-nitrosoguanidine in the duodenum of mice.
Yoshizumi MATSUKAWA ; Hoyoku NISHINO ; Mitsunori YOSHIDA ; Hiroyuki SUGIHARA ; Kanade KATSURA ; Tetsurou TAKAMATSU ; Junichi OKUZUMI ; Katsuhiko MATSUMOTO ; Fumiko SATO-NISHIMORI ; Toshiyuki SAKAI
Environmental Health and Preventive Medicine 2002;6(4):235-239
Quercetin, a flavonoid, widely distributed in many fruits and vegetables, is well known to have an antitumor effect despite its mutagenicity. In this study, we examined the effect of dietary quercetin on duodenum-tumorigenicity of mice induced by a chemical carcinogen, N-ethyl-N'-nitro-N-nitrosoguanidine (ENNG). Eight-week-old male C57BL/6 mice were divided into 4 groups; ENNG without quercetin (group A), ENNG with 0.2% quercetin (group B), ENNG with 2% quercetin (group C), and 2% quercetin without ENNG (group D). ENNG was given in drinking water for the first 4 weeks, and thereafter quercetin was given in a mixed diet. At week 20, the average number of duodenal tumors per mouse was significantly higher in group C (mean±SE, 7.26±1.75, p<0.05) than in group A (2.32±0.31). The size of the duodenal tumors increased significantly in group B (1.79±0.09 mm, p<0.001) compared with group A (1.43±0.09 mm). In contrast, no duodenal tumor was induced in group D. The present findings suggest that excessive intake of quercetin occasionally is a risk factor for carcinogenesis of some specific organs such as the upper intestine.
8.The Survey of The Urinary Complaints of The Outpatients in Acupuncture Clinics.
Hiroshi KITAKOJI ; Daisaku KUDO ; Shuichi KATAI ; Takao SAKAI ; Yukiko SUZUKI ; Masaki TSUDA ; Hideo OSAWA ; Takashi TSUJIMOTO ; Hisashi HONJO ; Tomoe MATSUYAMA ; Sigeru MASAGAKI ; Yoshinobu ODAHARA ; Tadashi YANO ; Tatsuzo NAKAMURA ; Kazushi NISIJO ; Katsuhiko MATSUMOTO
Journal of the Japan Society of Acupuncture and Moxibustion 1993;43(3):99-108
The frequencies of the urinary complaints oa the outpatients (male 188, female 339, average age 59.2+14.9) of the five acupuncture clinics were surveyed. The elder patients showed the higher frequencies of the urinary complaints. The frequencies of the complaints were as follows: nocturia (25.8%), urinary urgency (17.7%), stress incontinence (16.3%), sense of residual urine (15.2%), protracted micturition (12.0%), and retarded micturition (11.3%), respectively. The nocturia was accompanied with the majority of the other urinary complaints. These results suggest that the survey of the patient's complaint of nocturia is useful.
9.Advancements and Challenges in Robot-Assisted Bone Processing in Neurosurgical Procedures
Yoshihiro KITAHAMA ; Hiroo SHIZUKA ; Yuto NAKANO ; Yukoh OHARA ; Jun MUTO ; Shuntaro TSUCHIDA ; Daisuke MOTOYAMA ; Hideaki MIYAKE ; Katsuhiko SAKAI
Neurospine 2024;21(1):97-103
Objective:
Practical applications of nerve decompression using neurosurgical robots remain unexplored. Our ongoing research and development initiatives, utilizing industrial robots, aim to establish a secure and efficient neurosurgical robotic system. The principal objective of this study was to automate bone grinding, which is a pivotal component of neurosurgical procedures.
Methods:
To achieve this goal, we integrated an endoscope system into a manipulator and conducted precision bone machining using a neurosurgical drill, recording the grinding resistance values across 3 axes. Our study encompassed 2 core tasks: linear grinding, such as laminectomy, and cylindrical grinding, such as foraminotomy, with each task yielding unique measurement data.
Results:
In linear grinding, we observed a proportional increase in grinding resistance values in the machining direction with acceleration. This observation suggests that 3-axis resistance measurements are a valuable tool for gauging and predicting deep cortical penetration. However, problems occurred in cylindrical grinding, and a significant error of 10% was detected. The analysis revealed that multiple factors, including the tool tip efficiency, machining speed, teaching methods, and deflection in the robot arm and jig joints, contributed to this error.
Conclusion
We successfully measured the resistance exerted on the tool tip during bone machining with a robotic arm across 3 axes. The resistance ranged from 3 to 8 Nm, with the measurement conducted at a processing speed approximately twice that of manual surgery performed by a surgeon. During the simulation of foraminotomy under endoscopic grinding conditions, we encountered a -10% error margin.
10.Advancements and Challenges in Robot-Assisted Bone Processing in Neurosurgical Procedures
Yoshihiro KITAHAMA ; Hiroo SHIZUKA ; Yuto NAKANO ; Yukoh OHARA ; Jun MUTO ; Shuntaro TSUCHIDA ; Daisuke MOTOYAMA ; Hideaki MIYAKE ; Katsuhiko SAKAI
Neurospine 2024;21(1):97-103
Objective:
Practical applications of nerve decompression using neurosurgical robots remain unexplored. Our ongoing research and development initiatives, utilizing industrial robots, aim to establish a secure and efficient neurosurgical robotic system. The principal objective of this study was to automate bone grinding, which is a pivotal component of neurosurgical procedures.
Methods:
To achieve this goal, we integrated an endoscope system into a manipulator and conducted precision bone machining using a neurosurgical drill, recording the grinding resistance values across 3 axes. Our study encompassed 2 core tasks: linear grinding, such as laminectomy, and cylindrical grinding, such as foraminotomy, with each task yielding unique measurement data.
Results:
In linear grinding, we observed a proportional increase in grinding resistance values in the machining direction with acceleration. This observation suggests that 3-axis resistance measurements are a valuable tool for gauging and predicting deep cortical penetration. However, problems occurred in cylindrical grinding, and a significant error of 10% was detected. The analysis revealed that multiple factors, including the tool tip efficiency, machining speed, teaching methods, and deflection in the robot arm and jig joints, contributed to this error.
Conclusion
We successfully measured the resistance exerted on the tool tip during bone machining with a robotic arm across 3 axes. The resistance ranged from 3 to 8 Nm, with the measurement conducted at a processing speed approximately twice that of manual surgery performed by a surgeon. During the simulation of foraminotomy under endoscopic grinding conditions, we encountered a -10% error margin.