1.Angular dose dependency of MatriXX and its calibration
Qixin LI ; Penggang BAI ; Xiuchun ZHANG ; Kaiqiang CHEN ; Sisi ZHANG
Chinese Journal of Radiological Medicine and Protection 2011;31(2):229-232
Objective To characterize angular dependency of MatfiXX and develop a method for its calibration in order to verify treatment plan with original gantry angles.Methods Absolute dose calibration was carried with thimble ionization chamber on the linear accelerator.so as to make sure 1 MU=1 cGy at the depth of maximum dose(dmax).A MatriXX was put into a Mutlicube phantom,and the ionization chamber matrix was calibrated with absolute dose.In order to determine a correction factor CF as a function of gantry angle θ.open beam fields of 10 cm×10 cm size were irradiated for gantry angles θ=0°-180°(every 5°)and every 1°for lateral angles θ in the range of 85°-95°.CF was defined as the ratio of the dose measured with ionization chamber and the dose from MatriXX.Results Relatively large discrepancies in response to posterior VS.anterior fields for MatriXX detectors(up to 10%)were found during the experiment and relatively large variability of response as a function of gantry angle.The pass rate of treatment plan in lateral beams was lower than that of other beams.The isodose distribution of corrected MatriXX matched well with the outcome from the treatment planning system. Conclusions The angular dose dependency of MatriXX must be considered when it is used to verify the treatment plan with original gantry angles.
2.Dosimetric study of different intensity-modulated modalities in the radiotherapy for mid and upper thoracic esophageal carcinoma
Cairong HU ; Xiaojuan YIN ; Xiuchun ZHANG ; Kaiqiang CHEN ; Ming CHEN ; Junqiang CHEN
Chinese Journal of Radiological Medicine and Protection 2014;34(3):220-224
Objective To compare the static intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) for mid and upper thoracic esophageal cancer.Method The data of twenty esophageal cancer patients were retrospectively re-planned with VMAT(single arc and double arcs) modality using Pinnacle treatment plan system.Five of these patients were selected again to simulate single arc plans with different segment intervals (4°,3°,2°) and re-planned on other treatment planning systems (Monaco and MasterPlan).Differences of dose distribution and treatment parameters were compared.Results In comparison to IMRT and single-VMAT (S-VMAT),Double-VMAT (D-VMAT) significantly improves the dosimetric parameters for targets(P < 0.05),dose homogeneity(P < 0.05) and conformity(P < 0.05).Though VMAT plans were slightly better than IMRT in reducing the doses to the organs at risk (OARs),no advantage was observed in the low-dose protection of lung and E-P (P < 0.05).For the VMAT plans with different segment intervals,lower OAR doses were observed using an interval of 2°(P < 0.05),except for the mean dose of the heart.For the VMAT plans on different treatment planning systems,Monaco-based plans protected OARs better (P < 0.05).The number of monitor units (MU) and treatment time were less in VMAT cases.Conclusions VMAT plans perform better in target coverage,dose homogeneity and conformity,and can reduce the radiation dose to the spinal cord,lungs,heart and other normal tissue than IMRT plans.The VMAT plan quality could be further improved by using double arcs and smaller segment interval.Monaco-based plans provide better OAR protections under the same conditions of physical and optimization parameters.
3.A study of changes in volume and location of target areas and organs at risk in intensity-modulated radiotherapy for cervical cancer
Jianwu CHEN ; Ping LIU ; Wenjuan CHEN ; Penggang BAI ; Jiangshan LI ; Xiaolei NI ; Kaiqiang CHEN ; Qixin LI
Chinese Journal of Radiation Oncology 2015;(4):395-399
Objective To investigate the changes in volume and spatial location of target areas and normal tissues before and during intensity?modulated radiotherapy (IMRT) for cervical cancer by quantitative means. Methods Forty patients with cervical cancer who were treated with IMRT were enrolled as subjects. Computed tomography ( CT) was performed before IMRT and during IMRT when a dose of 27 Gy ( 15 fractions) was reached. Clinicians delineated the target areas and organs at risk in the two groups of CT images. The target areas and organs at risk in one group of images were mapped to the other group of CT image by image registration using the Pinnacle treatment planning system. Volume changes in target areas and organs at risk were analyzed, and changes in the spatial location were evaluated by volume difference method and Dice similarity method. Comparison was made by paired t?test. Results There were significant differences in gross target volumes of primary tumor lesions ( GTV?T) and pelvic metastatic lymph nodes (GTV?N) before and during IMRT ( P= 0?? 000; P= 0?? 000). According to the evaluation by volume difference method, the average rate of change in GTV?T was (38.64±19?? 50)% with a range between 3?? 16%and 86?? 49%, while the average rate of change in GTV?N was (42.49± 25?? 68)% with a range between 2?? 79% and 87?? 42%. In the organs at risk, the bladder had the maximum rate of volume change, the average of which was (55.13±33?? 40)% with a range between 3?? 25% and 116?? 01%. According to the evaluation by Dice similarity method, the average Dice similarity coefficient for GTV?T was 0.50± 0?? 18 with a range between 0?? 10 and 0?? 85, while the average Dice similarity coefficient for GTV?N was 0.31±0?? 20 with a range between 0?? 00 and 0?? 71. The rectum had the minimum Dice coefficient in the organs at risk, the average of which was 0.57± 0?? 14 with a range between 0?? 18 and 0?? 76 . Conclusions For patients with cervical cancer to receive IMRT, since there are substantial changes in volume and spatial location of target areas and normal tissues before and during treatment, it is quite necessary to modify the treatment regimen in time in order to provide adequate doses for target areas and avoid overdose for organs at risk.
4.Dosimetric verification of volumetric modulated arc therapy in nasopharyngeal carcinoma using COMPASS 3D patient anatomy based system
Penggang BAI ; Qixin LI ; Kaiqiang CHEN ; Xiuchun ZHANG ; Yazhi WANG ; Xingwu HUANG
Chinese Journal of Radiological Medicine and Protection 2012;32(3):304-307
Objective To investigate the dosimetric performance of COMPASS system,a novel 3D quality assurance system for the verification of nasopharyngeal carcinoma volumetric modulated therapy (VMAT) treatment plan.Methods Eight VMAT treatment plans of nasopharyngeal carcinoma patients were performed with MasterPlan,a treatment planning system (TPS),and then these treatment plans were sent to the COMPASS and MOSAIQ system,a coherent control system,respectively.Comparison of the COMPASS reconstructed dose versus TPS dose was conducted by using the dose volume-based indices:dose received by 95% volume of target ( D95% ),mean dose ( Dmean ) and γ pass rate,dose to the 1% of the spinal cord and brain stem volume ( D1% ),mean dose of leaf and right parotid ( Dmean ),and the volume received 30 Gy for left and right parotid (V30).COMPASS can reconstruct dose with the real measured delivery fluence after detector commissioning.Results The average dose difference for the target volumes was within 1%,the difference for D95 was within 3% for most treatment plans,and the γ pass rate was higher than 95% for all target volumes.The average differences for the D1% values of spinal cord and brain stem were ( 4.3 ± 3.0) % and ( 5.9± 2.9 ) % respectively,and the average differences for the Dmean values of spinal cord and brain stem were ( 5.3 ± 3.0 ) % and ( 8.0 ± 3.5 ) % respectively.In general the COMPASS measured doses were all smaller than the TPS calculated doses for these two organs.The average differences of the Dmean values of the left and right parotids were( 6.1± 3.1 ) % and ( 4.7 ± 4.4 ) % respectively,and the average differences of the V30 values of the left and right parotids were (9.4 ± 7.5 ) % and (9.4 ± 9.9)% respectively.Conclusions An ideal tool for the VMAT verification,the patient anatomy based COMPASS 3D dose verification system can check the dose difference between the real delivery and TPS calculation directly for each individual organ,either target volumes or critical organs.
5.Role of potassium channel in remifentanil-induced prolongation of monophasic action potential duration in myocardium of rabbits
Yanqiu LIU ; Hong GAO ; Li AN ; Kaiqiang ZHANG ; Juan LONG ; Chao CHEN
Chinese Journal of Anesthesiology 2016;36(2):151-153
Objective To investigate the role of potassium channel in remifentanil-induced prolongation of monophasic action potential duration (MAPD) in the myocardium of rabbits.Methods Eighteen adult rabbit hearts successfully perfused in a Langendorff apparatus were randomly divided into 3 groups (n =6 each) using a random number table:control group (group C),remifentanil group (group R),and K+ channel blocker tetraethylammonium group (group T).After 15 min stabilization with K-H solution,group C was continuously perfused with K-H solution for 60 min,and R and T groups were perfused with KH solution containing 12 ng/ml remifentanil and 10 ng/ml tetraethylammonium,respectively,for 60 min.At 15 min of stabilization,and 15,30 and 60 min of perfusion,heart rate,MAPD of all the three layers of the myocardium in the anterior wall of the left ventricular was recorded.MAPD at 50% and 90% repolarization (MAPD50,MAPD90) were calculated.Results Compared with group C,heart rate was significantly decreased,MAPD50 and MAPD90 were prolonged in R and T groups (P <0.05).Conclusion The mechanism by which remifentanil prolongs MAPD in the myocardium of rabbits is associated with blockade of the potassium channels.
6.Clinical efficacy of SAS and QOL in cystitis glandularis after transurethral resection of bladder
Yaowu SU ; Jun ZHOU ; Kaiqiang CHEN ; Jianjun LU ; Weihua LIU ; Chunxia LIU
Chinese Journal of Biochemical Pharmaceutics 2017;37(4):125-127
Objective To investigate the clinical effects of transurethral resection of cystitis after gynecological cystitis after transurethral resection of bladder,and to observe the effect on patients' anxiety(SAS)and quality of life index(QOL).Methods The clinical data of 62 patients with cystitis glandularis admitted to hospital from January 2011 to December 2016 were retrospectively analyzed.The control group was treated with plasma ablation alone,with plasmakinetic resection of Kangfuxin liquid combined with gemcitabine intravesical therapy as the treatment group,31 cases in each group.Statistics of two groups of patients with clinical efficacy,followed up for 12 months,and the anxiety self-rating scale(SAS)was used to evaluate the anxiety of the two groups before and after treatment,QOL was used to evaluate the quality of life before and after treatment in two groups of patients.The recurrence rate of two groups were recorded.Results After treatment,the effective rate of the treatment group was 80.65%,slightly higher than the control group 77.42%,the difference was statistically significant(P<0.05),the SAS score in the treatment group was slightly higher than before treatment,but the difference was not statistically significant,the SAS score in the control group was significantly lower than before treatment,after treatment between the groups,the difference was statistically significant(P<0.05).The QOL index of the treatment group decreased slightly after treatment,but the difference was not statistically significant.The QOL index of the treatment group decreased significantly after treatment,and compared between the two groups after treatment,the difference was statistically significant(P<0.05).Follow-up of 12 months,the relapse rate in the treatment group was 11.11%,slightly lower than the control group 18.75%,the difference was statistically significant(P<0.05).Conclusion Compared to pure plasmapheresis,the use of postoperative intravesical instillation of bladder irrigation with the same effect,but the latter may increase the degree of anxiety in patients,thus affecting the quality of life of patients,so for the non-mandatory use of drugs treatment,surgery may be given priority to surgery alone.
7.The correlation between different CT scanning mode and the target volume of movement tumor
Junxin WU ; Yu WANG ; Penggang BAI ; Junjun ZHANG ; Qixin LI ; Kaiqiang CHEN
Chinese Journal of Radiation Oncology 2015;24(1):90-92
Objective To investigate change of the volume and the epicenter of target volume under different scan speed of the three-dimensional (3D) simulation computed tomography (CT) and determine the scan speed which close to ITV.Methods A dynamic phantom-QUASAR,with a 3 cm × 3 cm × 3 cm target cubic simulating respiratory motion was used.The phantom was set with three different amplitudes and breathing frequencies under different scan speed.The dynamic phantom was also scanned using simulation 4DCT as ITV was the standard.The length of the phantom was 12 cm,the scan time were 6.6 s,12.8 s,31.7 s.The volume and epicenter of the target identified from 3DCT images were calculated and compared to 4DCT images.The number of times of target length (30 ± 2) mm/total scan times was used to assese the accuracy.Results The total accuracy was 6.8%.For different scan speed,the accuracy were 13%,4% and 2%,respectively.The length of the epicenter of the target volume was (318.9 ±0.37) mm,(683.2 ±0.44) mm,(682.9 ± 0.66) mm under the 0.5 cm,1.0 cm and 2.0 cm,respectively.When the scan time was 31.7 s,the volume of the target from the 3DCT were close to ITV-10 mm,the frequency were 50%,78%,56% for three different amplitude.Conclusions This study shows that the images from the 3D simulation CT were the partial image of the breathing cycle,and the epicenters were diversed with the breathing amplitude and scan speed.The accuracy rate of the 3DCT reflects the real target is low.In addition,the epicenter of the target changed randomly.
8.Dosimetric comparison of three intensity-modulate radiation therapy treatment modules for nasopharyngeal carcinoma
Qixin LI ; Qi YUE ; Penggang BAI ; Kaiqiang CHEN ; Xiuchun ZHANG ; Shaojun LIN ; Yiyan QU
Chinese Journal of Radiological Medicine and Protection 2014;34(8):613-616
Objective To compare the dosimetric differences of fixed field intensity-modulated radiation therapy(IMRT),volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) for nasopharyngeal carcinoma (NPC) patients.Methods Eighteen NPC patients previously treated with VMAT were retrospectively included and re-planned using HT and IMRT (7 fields) techniques utilizing the same dose prescription and optimization objectives.The following parameters were compared across the three types of plans:homogeneity index (HI),conformity index (CI),maximum dose (Dmax) and mean dose (Dmean) of targets ; the Dmax and Dmean of organs at risk (OARs) ; the doses and volumes of volume of interest; the treatment delivery time and monitor units (MU).Results Clinically acceptable target coverage could be achieved by IMRT,VMAT and HT plans.The HT plans were the best yet IMRT plans were the worst in HI and CI of targets.IMRT imposed highest doses to OARs while HT deposited least doses to the spinal cord,brainstem and parotid.However,the VMAT plans displayed the lowest doses on optic nerves,chiasma and lens while highest doses were found in IMRT plans.The average delivery time per fraction of IMRT (8.0±0.5) min were more than that of HT (7.4 ±0.9) min and VMAT (3.9 ±0.1) min plans.The MUs of IMRT plans (711.4 ±78.7) were larger than that of VMAT plans (596.4 ±33.7).Conclusions Three types of plans can all achieve the clinical dosimetric demands,but HT has the best performance on CI and HI.VMAT is most efficient regarding the delivery time and total MUs.
9.Dosimetric comparison of combined intracavitary/interstitial brachytherapy planning using three different kinds of optimization methods in locally advanced cervical cancer
Kaiqiang CHEN ; Hongqiang YOU ; Qixin LI ; Xiaolei NI ; Wenjuan CHEN ; Xiuchun ZHANG ; Penggang BAI ; Ye CAO ; Jihong CHEN
Chinese Journal of Radiological Medicine and Protection 2018;38(3):215-219
Objective To compare and analyze the dosimetric discrepancy of combind intracavitary/interstitial brachytherapy using three different kinds of optimization method in locally advanced cervical cancer.Methods Totally 20 cases of locally advanced cervical cancer were selected and divided into three groups according to different optimization method which include manual optimization group (MO) based on graphical optimization,inverse planning simulated annealing (IPSA 1)based on simulated annealing optimization algorithm,IPSA 2 based on IPSA 1 with limitation on maximum dose of target.The dose volume histogram parameters of the targets (V200,V150,V100,D100,D90,HI) and the OARs(D0.1 cm3,D1 cm3 and D2 cm3) were analyzed.Results For CTV,compared with MO,there was no significantly statistical difference in D100between IPSA 1 and IPSA 2(P > 0.05).However,V200,V150,V100 and HI for ISPA1 were better than for ISPA2 (t =-3.422-9.910,P < 0.05).In addition,V100 and D100 in ISPA1 were better than in ISPA2 (t =7.238,5.032,P <0.05).For OARs,D0.1 cm3,D1 cm3 and D2 cm3 in rectum,bladder,sigmoid colon of both ISPA 1 and ISPA 2 were dramatically lower than those of MO (t =2.235 5.819,P < 0.05),without significantly statistical difference found between ISPA1 and ISPA2.Conclusions For combined intracavitary/interstitial brachytherapy in locally advanced cervical cancer,all treatment plans based on three different kinds of optimization methods can meet the clinical need.Moreover,inverse optimization can ensure dose coverage over target and reduce maximum dose of rectum,bladder and sigmoid colon.
10. The protective effect of Xuebijing on paraquat-induced HK-2 cells apoptosis and the underlying mechanisms
Xin TIAN ; Wanli ZHANG ; Lili HU ; Xingrong SHE ; Guangliang HONG ; Liming CHEN ; Kaiqiang CAO ; Zhongqiu LU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2018;36(1):1-6
Objective:
To investigate the protective effect and mechanism of Xuebijing (XBJ) on paraquat (PQ) -induced apoptosis in Human kidney cell line-2 (HK-2) cells.
Methods:
Routinely cultured HK-2 cells, (1) Cell growth inhibition experiment after PQ and XBJ intervention: PQ was divided into 0、200、400、800、1600 and 3200 μmol/L PQ groups, and the cell survival rate was detected after intervening 24、48 and 72 h. XBJ was divided into 0、5、10、20、40 mg/ml XBJ groups, and the cell survival rate was detected after intervening 24、48 and 72 h.To determine the rational drug concentration and the duration of action of XBJ and PQ. (2) PQ-induced HK-2 cell growth inhibition experiment antagonized by XBJ: The cells were divided into normal control group, PQ group (800 μmol/L) and PQ+XBJ group (The cells were pretreated with 5、10 and 20 mg/ml XBJ for 1 h, then cultured with PQ of 800 μmol/L) , After cultured 24 h、48 h and 72 h separately, the cell survival rate was detected. (3) HK-2 cells were divided into normal control group、PQ group (800 μmol/L PQ cultured for 24 h) 、PQ+XBJ group (pretreated with 10 mg/ml XBJ for 1 h, and then 800 μmol/L PQ cultured for 24 h) and XBJ group (10 mg/ml XBJ cultured 24 h). The apoptosis of cells was detected by flow cytometry. The protein expression of Bcl-2 and BAX in each group was detected by Western blotting. The expressions of caspase-3 and caspase-9 were detected by caspase-3 and caspase-9 activity kit active.
Results:
(1) PQ could significantly reduced the survival rate of HK-2 cells and showed time and concentration dependence. The survival rate of HK-2 cells was about 55% after 800 μmol/L PQ contacted 24 h, XBJ under 20 mg/ml was no significant effect on the survival rate of HK-2 cells after cultured 72 h. (2) Compared with the PQ group, the survival rate of HK-2 cells of PQ+XBJ group was significantly increased (