1.Effect of skin color on the setup of surface optical system in radiotherapy
Haiyan PENG ; Huanli LUO ; Baozhong LIANG ; Kaijin MAO ; Yang HE ; Fu JIN
Chinese Journal of Radiation Oncology 2021;30(12):1297-1303
Objective:To investigate the sensitivity of the Catalyst HD in monitoring different skin colors, and assess the effect of skin color on the setup uncertainties using this system in radiotherapy.Methods:The standard cards guiding skin color and the cylinder model guiding quality control in radiotherapy were utilized to simulate the patients’ positioning. During the first monitoring, Catalyst HD was employed to acquire the image of the phantom as the reference image after conventional positioning (indoor laser+ phantom marking). When it was not the first monitoring, the couch was moved (-5 to 5 mm, step length of 2 mm) and Catalyst HD was adopted to obtain the surface image after conventional positioning. The bed deviation and corresponding setup errors monitored by Catalyst HD for different skin colors were recorded in the anterior-posterior (AP), superior-inferior (SI) and left-right (LR) direction, respectively.Results:During Catalyst HD monitoring, the integration time and gain were increased with the darker color. The logarithm of integration time and gain was significantly linearly negatively correlated with the same color ( R2>0.9). When the color difference with 1Y01SP was ΔE≤189, there was a significant correlation between the bed deviation and corresponding setup errors monitored by Catalyst HD in the SI and LR directions (R SI>0.5, R LR>0.5, R AP>0.9). The Catalyst HD monitoring was rapid and stable. When 218≤ΔE≤253, the correlation coefficients of them in the LR were R LR<0.3 and the Catalyst HD monitoring was stable. When 254≤ΔE≤285, the Catalyst HD failed to monitor stably. When ΔE>318, it failed to monitor this skin color. Conclusions:Gain, integration time and color have a certain correlation. The Catalyst HD can accurately monitor the setup errors within a specific range of skin color.
2.Clearance of HBsAg in patients with chronic hepatitis B treated by entecavir plus Peg IFNα-2b following initial entecavir monotherapy
Lingxiao JIN ; Qin NI ; Xuhong ZHAO ; Haizhen HUANG ; Junfeng YIN ; Jianghao HONG ; Jialiang MAO ; Dong YAN ; Kaijin XU
Chinese Journal of Clinical Infectious Diseases 2018;11(4):275-281
Objective To analyze the efficacy of entecavir (ETV) combined with Peg IFNα-2b in chronic hepatitis B ( CHB) patients with low levels HBsAg following initial ETV treatment.Methods Sixty-nine CHB outpatients achieving serum HBsAg <2 000 IU/mL and HBV DNA<100 IU/mL following initial ETV treatment in Pujiang People's Hospital and the First Affiliated Hospital of Zhejiang University School of Medicine from January 2014 to January 2016 were enrolled.Patients were randomly assigned in two groups: 39 patients in combination group received ETV (0.5 mg/d ) and Peg IFNα-2b (1.5 μg· kg-1· week -1, hypodermic injection), and 30 patients in ETV group received ETV (0.5 mg/d) alone.Serum HBsAg quantification, negative conversion rate of HBsAg and HBeAg , and levels of aminotransferase (ALT) were measured at baseline , 12th, 24th, 48th, 72th and 96th week after treatment.Results The levels of HBsAg in the combination group decreased gradually with the prolongation of therapy , which were lower than those in ETV group 24 week after treatment (Z=-2.566,P<0.05),and at 48th, 72th and 96th week (Z=-3.499,-3.825 and -3.864,P<0.01).Clearance of HBsAg appeared in the combination group at 24th week,the clearance rates were 7.70%(3/39) and 28.20%(11/39) at 24th and 96th week, respectively;while the clearance of HBsAg occurred in ETV group at 96th week, the clearance rate was only 3.30%(1/30).The negative conversion rates of HBsAg in combination group were higher than those in ETV group at 48th,72th and 96th week (P<0.05 or<0.01).In the combination group, there were 11 cases of clinical cure , 11 cases of clinical efficacy and 17 cases of clinical effectiveness , while there were 1, 1 and 28 cases in ETV group,respectively.The treatment effect of the combination group was better than that of ETV group(χ2=18.496,P<0.01).Serological conversion rates of HBeAg were 30.00%(6/20) and 65.00%(13/20) in combination group at 12th and 96th week, while those were 11.11%(2/18) and 22.22%(4/18) in ETV group at 48th and 96th week.There were significant differences in the HBeAg serological conversion rates at 12th, 24th, 72th and 96th week between two groups (P<0.05 or <0.01). The levels of ALT in combination group increased at 12th and 24th week, which had significant difference compared with ETV group (Z=-1.236 and -2.658,P<0.05), and the ALT levels gradually declined 48 week after treatment in combination group and there were no statistical differences between two groups at other time points.The ETV combined with Peg IFNα-2b and low baseline HBeAg levels were associated with the clearance rate of HBsAg (both P<0.01).Conclusions CHB patients with low HBsAg levels following initial ETV monotherapy can achieve high negative conversion rate of HBeAg and HBsAg with the combination treatment of ETV and Peg IFN α-2b.
3.Research progress of cognitive impairment in adults patients after infectious meningitis
Lin MAO ; Min XU ; Li WANG ; Liliang ZOU ; Yifan ZHAO ; Daming WANG ; Kaijin XU
Chinese Journal of Clinical Infectious Diseases 2022;15(3):228-234
Cognitive impairment after infectious meningitis seriously affects the activities of daily living for survivors. There has been lack of systematic researches on the cognitive impact of infectious meningitis so far, it is not clear how to early identify and evaluate the cognitive impairment after meningitis, how to properly carry out early rehabilitative intervention to improve the activities of daily living and to reduce the social and economic burden of patients. This article reviews the characteristics, evaluation methods and rehabilitative interventions of cognitive impairment in patients after infectious meningitis, to provide reference for clinical application.
4.Clinical application of Catalyst system in cervical cancer radiotherapy
Haiyan PENG ; Huanli LUO ; Kaijin MAO ; Yang HE ; Dengyan WANG ; Lifeng PENG ; Yiyu ZHU ; Xuechun WANG ; Qinghong MIN ; Fu JIN ; Ying WANG
Chinese Journal of Radiation Oncology 2019;28(3):198-202
Objective To evaluate the clinical application of Catalyst system in positioning patients during cervical cancer radiotherapy,and to analyze its correlation with the bladder volume and body mass index (BMI) of patients.Methods A total of 33 patients diagnosed with cervical cancer from July to December 2017 in our hospital were included in the study.All patients were auxiliary positioned by an optical surface imaging system (C-Pad Catalyst) before each treatment.The CBCT imaging was executed twice a week.The setup errors from Catalyst and CBCT in the anterior-posterior (AP),superior-inferior (SI) and leg-fight (LR) directions were recorded.Each patient's bladder volume and BMI were also recorded.Results The setup errors between Catalyst with masks and CBCT had the significant difference in SI (P<0.05) and LR (P<0.05).For Catalyst without masks,the setup errors with the bladder volume of 200-300 ml had the significant association in SI (R=-0.316,P<0.05).For the bladder volume of>300 ml,the setup errors for Catalyst with masks had the significant association in AP (R=-0.493,P<0.05),and that without masks had the significant association in SI and LR (R=0.335,P<0.05,R=-0.348,P<0.05).For patients of<25 kg/m2,setup errors for Catalyst with masks had the significant association with the BMI in LR (R=0.197,P<0.05);for ≥ 25 kg/m2,that with masks had the significant association in AP and SI (R =0.818,P<0.05;R=-0.498,P<0.05),that without masks had the significant association in AP and LR (R=0.652,P<0.05;R=-0.558,P<0.05).Conclusion Unlike CBCT system,the patient positioning by Catalyst system was easily affected by the bladder volume and BMI of patients.
5. The effect of age on skin elasticity and setup error in optical surface image-guided radiotherapy
Yang HE ; Jinyan LEI ; Haiyan PENG ; Huanli LUO ; Kaijin MAO ; Dengyan WANG ; Lifeng PENG ; Yiyu ZHU ; Qinghong MIN ; Xuechun WANG ; Huan TANG ; Qiang XIAO ; Ying WANG ; Fu JIN
Chinese Journal of Radiation Oncology 2020;29(1):47-51
Objective:
To investigate the correlation between skin elasticity and setup error in optical surface image-guided radiotherapy.
Methods:
The skin elasticity (R7) data of the head, chest and abdomen were extracted and analyzed its correlation with age by systematic literature review. Fifty-four patients diagnosed with nasopharyngeal carcinoma, breast cancer and cervical cancer were recruited in this study. Firstly, the patients were positioned based on the room laser and markers. Subsequently, the patient position was verified by the Varian On-Board Imager, and then C-Rad Catalyst was adopted to obtain surface images in two states (mask or non-mask) as reference images. In the subsequent fraction treatment, after initial positioning, the local calibration was performed by Catalyst, and setup errors in three directions were recorded. Meanwhile, the patient setup was verified by CBCT twice a week. The
6.Inhibitory effect of connexin43 protein on autophagy in cisplatin-resistant testicular cancer I-10 cells.
Min YUAN ; Shuying DONG ; Yanxue YAO ; Yunzheng MEN ; Kaijin MAO ; Xuhui TONG
Journal of Southern Medical University 2019;39(9):1089-1093
OBJECTIVE:
To investigate the effect of connexin43 (Cx43) protein on autophagy in cisplatin (DDP)-resistant testicular cancer I-10 cells.
METHODS:
The expression of Cx43 proteins in testicular cancer I-10 cells and I-10/DDP cells were detected with Western blotting. I-10/DDP cells were transfected with a full- length mouse Cx43 vector (mCx43) Lipofectamine, the empty vector or Lipofectamine (blank control group), and the changes in the expressions of LC3 and p62 proteins were determined with Western blotting. mCherry-GFP-LC3B transfection and transmission electron microscopy were used to analyze the changes in autophagy of the cells with Cx43 overexpression.
RESULTS:
Cx43 was significantly decreased in I-10/DDP cells compared with I-10 cells ( < 0.01). Transfection of the I-10/DDP cells with mCx43 vector resulted in significantly increased Cx43 expression in the cells ( < 0.01) and caused significantly decreased expression of LC3-Ⅱ ( < 0.01) and increased expression of p62 ( < 0.05) as compared with the negative control cells. Both transmission electron microscopy and mCherry-GFP-LC3B transfection showed that the number of autophagosomes was obviously reduced in mCx43-transfected cells as compared with the negative control cells.
CONCLUSIONS
Cx43 inhibits autophagy in cisplatin-resistant testicular cancer I-10 /DDP cells.
Animals
;
Autophagy
;
Cell Line, Tumor
;
Cisplatin
;
Connexin 43
;
metabolism
;
Drug Resistance, Neoplasm
;
Male
;
Mice
;
Testicular Neoplasms
;
metabolism
;
pathology