1.Clinical efficacy of minimally invasive tendon blade technique in the treatment of moderate and severe gluteal muscle contracture.
Jia-Kai GAO ; Tao-Ran WANG ; Long BI ; Xiao-Chao CHEN ; Yan-Wu LIU ; Yao-Ping WU ; Xiang HE ; Zhi-Xia NIU
China Journal of Orthopaedics and Traumatology 2025;38(4):420-423
OBJECTIVE:
To investigate the clinical effect of minimally invasive technique in the treatment of moderate and severe gluteal muscle contracture.
METHODS:
A retrospective study was conducted on 85 patients (170 sides) with bilateral gluteal muscle contracture admitted from January 2016 to December 2019. All patients were treated with minimally invasive release of tendon knife. There were 32 males and 53 females, ranging in age from 15 to 37 years old, with an average age of (22.3±6.3) years old. Operation time, intraoperative blood loss, incision length, first postoperative ambulation time, complication rate, recurrence rate, and Harris hip score (HHS) were analyzed and evaluated.
RESULTS:
The average follow-up time was (16.2±4.6) months, ranging from 12 to 30 months. The operation time ranged from 7 to 15 min, with an average of (10.2±3.1) min. Intraoperative blood loss ranged from 2 to 20 ml, with an average of (8.4±2.2) ml. The incision length ranged from 0.6 to 2.0 cm, with an average of (0.8±0.3) cm. The time to postoperative ambulation ranged from 12 to 28 h, with an average of (20.0±3.2) h. All patients achieved primary wound healing without sciatic nerve injury or recurrence. HHS hip function scores ranged from 90 to 98, with an average score of (96.2±1.4). Complications included intraoperative tendon blade tip fracture in two cases (removed under fluoroscopic guidance) and subcutaneous hematoma in three cases-two resolved with compression and one with open evacuation.. Twenty-nine patients exhibited transient swaying gait postoperatively, of which 24 patients returned to normal after 4 weeks and 5 patients returned to normal after 6 weeks.
CONCLUSION
Minimally invasive tendon blade release is a safe and effective technique for treating gluteal muscle contracture, offering minimal trauma, rapid recovery, and excellent cosmetic and functional outcomes. However, it exhibits a low risk of blade tip fracture and sciatic nerve injury, warranting experienced surgical handling.
Humans
;
Male
;
Female
;
Adult
;
Minimally Invasive Surgical Procedures/methods*
;
Adolescent
;
Retrospective Studies
;
Buttocks/surgery*
;
Young Adult
;
Contracture/surgery*
;
Tendons/surgery*
;
Muscle, Skeletal/surgery*
2.Clinical analysis of treatment for lingual thyroglossal duct cyst with trans-oral robotic surgery.
Lanjun CAI ; Kai XU ; Chao HE ; Qimiao FENG ; Zheng LIU ; Xiang LU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1034-1037
Objective:To investigate the safety, feasibility and efficacy of trans-oral robotic surgery in the treatment of lingual thyroglossal duct cyst. Methods:The clinical data of 21 patients with lingual thyroglossal duct cyst underwent trans-oral robotic surgery from May 2017 to March 2025 were analyzed retrospectively. Results:The cysts in all 21 patients were successfully excised by trans-oral robotic surgery. The mean robotic set-up and exposure time, operation time, estimated intraoperative blood loss and recovery time for oral intake were (14.3±7.2) min ([range 5.0-32.0]min), (17.0±8.4) min (range[6.0-36.0]min), (8.4±5.9) mL (range[2.0-25.0]mL) and (2.1±2.2) days (range[0-7]days), respectively. No patients required tracheostomy, and no severe postoperative complications occurred. The patients were followed up for 2 to 96 months, with median follow-up time of 47 months, and 1 recurrence was observed. Conclusion:Excision of lingual thyroglossal duct cyst by trans-oral robotic surgery is safe and feasible, with rapid recovery and low recurrence rate, which is worth popularizing in clinical practice.
Humans
;
Thyroglossal Cyst/surgery*
;
Robotic Surgical Procedures/methods*
;
Retrospective Studies
;
Female
;
Male
;
Adult
;
Treatment Outcome
;
Middle Aged
;
Adolescent
3.Expression of CD88 in esophageal squamous cell carcinoma and relationship with epithelial-mesenchymal transition
Kunming XU ; Xiang LIU ; Kai ZHU ; Huayu LUO ; Linrui FAN ; Zhongyu ZHANG ; Hongzheng REN
Chinese Journal of Clinical and Experimental Pathology 2024;40(6):615-620
Purpose To study the relationshiPbetween CD88 expression and clinicopathologic features and epithelial-mesenchymal transition(EMT)in esophageal squamous cell carcinoma.Methods TCGA and TIMER database were used to analyze the expression level of CD88 in esophageal squamous cell carcinoma and adjaecnt esophageal squamous cell epithelium and its relationship with epithelial-mesenchymal transition.Par-affin specimens were collected from 199 patients with clinically diagnosed esophageal squamous cell carcinoma.Immunohisto-chemical EnVision method was used to detect the expression of CD88 and EMT-related proteins in esophageal squamous cell carcinoma and adjacent tissues,the relationship between CD88 expression and clinicopathological features,prognosis and EMT in ESCC tumors was analyzed.Results There were 86 cases with high CD88 expression and 113 cases with low CD88 expres-sion.The expression level of CD88 in esophageal squamous cell carcinoma was significantly higher than that of paracancerous tis-sue(P<0.001).The group with high CD88 expression had lower ESCC differentiation level(P<0.001)and higher T stage(P=0.03).The 5-year survival of patients with high CD88 ex-pression was significantly lower than that of patients with low CD88 expression(P=0.002).Cox univariate and multivariate analysis showed that CD88 expression was an independent prog-nostic factor for overall survival of patients with esophageal squa-mous cell carcinoma(P=0.013).The high expression of CD88 was negatively correlated with E-cadherin(r=-0.146,P=0.039),and positively correlated with vimentin(r=0.387,P=1.61e-08)and N-cadherin(r=0.304,P=1.3e-05).Con-clusion CD88 is highly expressed in esophageal squamous cell carcinoma.CD88 may affect the occurrence,development,in-vasion and metastasis of esophageal squamous cell carcinoma through EMT,and it might be used as a prognostic marker for e-sophageal squamous cell carcinoma patients.
4.Preparation of Polyethylenimine Modified Nickel Ferrite-Graphene Oxide Material and Its Application in Enrichment of Phosphopeptides
Kai-Na ZHANG ; Yuan LIU ; Xiang-Feng WANG ; Hai-Ling LIU ; Meng-Xia XIE
Chinese Journal of Analytical Chemistry 2024;52(5):664-673
The NiFe2O4-graphene oxide nanocomposite modified with polyethylenimine(GO@PEI-NiFe2O4)was prepared to purify and enrich phosphopeptides from biosamples.The Ni2+and Fe3+ions on its surface could coordinate with phosphate groups and then selectively adsorb phosphopeptides.PEI was conducive to the above combination due to its high hydrophilicity.The material showed good magnetic response properties and could be rapidly separated from samples with the aid of magnet.With tryptic digest of β-casein as sample,the enrichment property of the material to phosphopeptides was studied,which was compared with the results of GO@NiFe2O4,revealing the adsorption mechanism of GO@PEI-NiFe2O4.The static and dynamic binding properties of GO@PEI-NiFe2O4 were investigated using pTyr as a representative phosphopeptide,and the adsorption capacity was 36.2 μg/mg.The results showed that the material could remove the interference of nonphosphopeptides and effectively enrich phosphopeptides in complex matrix.After enrichment by GO@PEI-NiFe2O4,1535 phosphopeptides were identified from the tryptic digest of rat liver by mass spectrum and the enrichment effect of GO@PEI-NiFe2O4 greatly outperformed commercial Fe3+-IMAC kits.This work provided an efficient material for the enrichment of phosphopeptides,showing potential applications in phosphoproteomics research.
5.Prediction of Wind Turbine Lubricating Oil's Acid Value by Ordinary Least Square Method Based on Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy Through Higher-Order Derivative Combined with Angular Metric
Chun-Hui GE ; Yan-Jun LIU ; Meng-Shi CHEN ; Ce YANG ; Pei-Pei LIANG ; Zhi-Xiang YAO ; Kai ZHANG
Chinese Journal of Analytical Chemistry 2024;52(9):1254-1265,中插1-中插4
To address the key challenges in multivariate statistical modeling,a higher-order derivative approach combined with vector space angle multiplicative error correction was proposed for establishing an acid value prediction ordinary least squares(OLS)regression model based on attenuated total reflectance-Fourier transform infrared(ATR-FTIR)spectroscopy.By using acid values measured by potentiometric titration as reference,ATR-FTIR spectroscopy was utilized for direct calibration and prediction of acid values on 96 kinds of lubricating oil samples from a wind turbine.Firstly,the simulated hyperbolic(SH)method was employed to obtain accurate fourth derivative spectrum,resolving overlapping bands and enhancing spectral selectivity.Then,from the calibration set(48 samples),informative spectral regions were identified based on correlation coefficients.Next,the sample with the highest acid value was selected as the reference and1/(1+tan(θ/2))was used as the metric relation of the spectrum to suppress the multiplicity error caused by factors such as the change of effective optical path in ATR-FTIR spectroscopy.After pretreatment of the spectrum by the method of fourth-order derivative combined with angular quantity,the number of variables decreased from 1737 to 8,and the matrix condition number decreased from 1.85×1015 to 56.34,which effectively eliminated the collinearity issue for OLS regression.Direct OLS modeling on spectral preprocessed data achieved a determination coefficient of 0.981 for 47 validation samples,with a relative error range of-8.38%-8.22%,outperforming the commonly used partial least squares(PLS)method(Determination coefficient of 0.865,relative error of-27.82%-22.38%).It was proved that effective data preprocessing significantly improved the prediction accuracy of the model.Furthermore,when the number of calibration set was compressed to 25 and the number of validation set was expanded to 70,the model retained 8 variables with a condition number of 42.60,the determination coefficient of validation set was 0.972,and the relative error ranged from-10.80%to 12.31%.Comparing with the PLS method(Determination coefficient of 0.724,relative error of-34.26%-53.84%),the improvement was more obvious,which showed that the method could still have high prediction accuracy even with fewer modeling samples as well as robustness against multiplicative error interference.
6.Effect of light pattern on dopamine transporter in the guinea pig retina
Jingjing WANG ; Kai LI ; Kaidi XIANG ; Jun CHEN ; Linlin DU ; Jinliuxing YANG ; Sichen LIU ; Ling WANG ; Xiangui HE
Chinese Journal of Experimental Ophthalmology 2024;42(4):309-314
Objective:To study the distribution and changes of dopamine transporter (DAT) in guinea pig eyes under different light patterns.Methods:Thirty-six 3-week-old white ordinary-grade guinea pigs were randomly selected and divided into groups of 10 000 lx, 5 000 lx, and 500 lx, with 12 guinea pigs in each group exposed to strong light, medium strong light, and normal light, respectively.Each group was randomly divided into 3 subgroups, with 4 guinea pigs in each subgroup.The 3 subgroups of 500 lx group received light exposure for 5, 20, and 40 minutes, respectively.The 3 subgroups of 5 000 lx group received light exposure for 2, 4, and 40 minutes, respectively.The 3 subgroups of 10 000 lx group received light exposure for 2, 5, and 20 minutes, respectively.After light treatment, each group of guinea pigs was injected with 99mTc-TRODAT-1 for SPECT DAT imaging, and image data were collected by Micro-SPECT.The region of interest (ROI) of guinea pig retinas was analyzed using Micro-CT software.The counts of ROI were expressed as Sum, which reflected the relative distribution or density of DAT.The DAT density between experimental and control eyes of guinea pigs after light exposure, the differences in DAT density between guinea pig eyes under different light intensities, the differences in DAT density between guinea pig eyes after different light durations, and the cumulative and interactive effects of light intensity and light duration on DAT aggregation in guinea pigs were compared.Another 3 guinea pigs were selected, and after light exposure, the 3 guinea pigs' eyes underwent continuous image acquisition for 6 hours at 20-minute intervals, and 18 images per guinea pig were acquired to analyze the trend of DAT density in guinea pig eyes over time.This study was approved by the Ethics Committee of Shanghai General Hospital (No.2020SQ196). Results:The DAT density (Sum value) of experimental eyes at 500, 5 000, and 10 000 lx were 5 598.97±3 159.38, 8 636.78±2 503.16, and 7 407.39±2 053.41, respectively, significantly higher than 4 388.89±2 902.90, 5 981.92±3 057.44, and 5 091.32±2 039.36 of control eyes ( t=5.31, 4.69, 11.80; all at P<0.001). At 500 lx, there was a statistically significant difference in DAT density between the experimental and control eyes of guinea pigs at different light exposure durations ( F=14.01, P<0.01), while no significant difference was found at other light intensities at different light exposure durations (both at P>0.05). When the light exposure time was 5 minutes, the difference in DAT density between the experimental and control eyes of guinea pigs was significantly greater in the 10 000 lx group than in the 500 lx group ( t=-13.22, P<0.001). There was no statistically significant difference between different groups at other light exposure durations (all at P>0.05). No cumulative or interactive effects of light intensity and light duration were found on the differences in DAT density (all at P>0.05). Continuous scanning after illumination showed that DAT density in guinea pig retinas first increased to a peak over time and then gradually returned to normal values. Conclusions:Light, even under moderate or normal light levels, can cause an increase in the secretion of DAT in the retina and stimulate the production of DAT.Light intensity and duration have no cumulative or interactive effects on the distribution and density of retinal DAT.
7.Status of wearable flexible monitoring devices based on organic field effect transistors in biomedical field
Kai GUO ; Cui-Zhi TANG ; Bo SUN ; Duan-Qiang XIAO ; Yuan-Biao LIU ; En-Xiang JIAO ; Jie GONG ; Hai-Jun ZHANG
Chinese Medical Equipment Journal 2024;45(1):93-100
The working principle and development of flexible semiconductor devices based on organic field effect transistor(OFET)technology were introduced.The current research status of OFET-based wearable flexible monitoring devices were reviewed,including biomechanical monitoring devices,tattoo biomonitoring devices and cellular detection devices and etc.The deficiencies of OFET-based wearable flexible monitoring devices were analyzed,and it's pointed out that miniaturization,personalization and diversification were the directions for the development of the future OFET-based wearable flexible moni-toring devices.[Chinese Medical Equipment Journal,2024,45(1):93-100]
8.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
9.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
10.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.

Result Analysis
Print
Save
E-mail