1.Effect of Drag-reducing Polymers on Coronary Microcirculation in Experimental Canine Model
Xianghui CHEN ; Kai CUI ; Feng HU ; Daogang ZHA ; Jiancheng XIU ; Pingsheng WU ; Yili LIU
Chinese Circulation Journal 2015;(6):573-575
Objective: To test the feasibility of drag-reducing polymers (DRP) for improving coronary microcirculation in a canine model in order to provide the experimental basis for treating myocardial microcirculation dysfunction. Methods: A total of 8 dogs received open-chest surgery and they had intravenous injections, in turn, with adenosine (ADN), DRP 250 mg/L and DRP+ADN. The function y=A × (1-e-βt) was used to calculate the myocardium capillary volume (A value), capillary velocity (β value) and myocardial blood lfow (A ? β value) by myocardial contrast echocardiography. Results: With DRP infusion, the A value in experimental canine was similar to the baseline condition,P>0.05; while theβ value and A ? β value were signiifcantly increased as (0.57 ± 0.10) 1/s vs (0.23 ± 0.03) 1/s,P<0.01 and (11.51 ± 1.96) VI/s vs (5.15 ± 0.86) VI/s,P <0.05 respectively. With combined infusion of DRP+ADN, the β value and A ? β value were similar to the baseline condition, bothP>0.05. Conclusion: DRP improved coronary microcirculation primarily by modulating the β value in experimental canine model, and hopefully, this unique hemodynamics could provide a new approach for treating myocardial microcirculation dysfunction.
2.Free forearm flap and free iliac bone reconstruct the composite tissue defects of the floor of mouth and the lower part of face in the same period
Jin-cheng XU ; Bao-quan LU ; Quan-shun HUANG ; Jian-cheng LI ; Kai NG ZHA ; Sheng-kai LIA0 ; Tao XU
Chinese Journal of Microsurgery 2011;34(4):283-286
ObjectiveTo probe into the clinical efficiency of reconstruction to person who had composite tissue defect of the floor of mouth and the lower part of face with the free forearm flap and free iliac bone in the same term.MethodsBefore the surgery, the surgeon should carefully evaluate the scope and shape of defects in 11 cases who had the composite tissue defects of the floor of mouth and the lower part of face, to design the individual forearm flap, so that it matches with the defect region. During surgery, the first resumption of defects using titanium plates forming the basic shape of mandible and the occlusal relationship,then used to re-sawing to take modeling of the iliac bone,transplanted free iliac bone and fixed after the inside of the titanium plate, thereby restoring the continuity of mandible missing.ResultsFree forearm flap and free iliac bone all survived in 11 cases, the success rate of 100%. The patients were followed up for 6 to 12 months, although the shape of restoration areas were different levels of fat, but eating, swallowing and other oral function had been well improved, 7/11 could enter normal diet, 4/11 to enter liquid diet, At the same time, the patients in social activities can communicate in a language daily, sensory function of skin flap and facial appearance has been satisfactory recovery.ConclusionConformal free forearm flap and free iliac bone is an ideal way to reconstruct the composite tissue defects of the floor of mouth and the lower part of face in the same period, not only safe, practical prognostic effect, and also can significantly improve the patients quality of life, which is worthy of reference and use.
3.Structure kinetic model of Maackia amurensis cells in suspension culture.
Kai LUO ; Xue-Qiang ZHA ; Jian-Ping LUO
Chinese Journal of Biotechnology 2007;23(4):657-661
A structure kinetic model was established for describing the relationship among cell growth, genistein formation and substrate utilization in suspension culture of Maackia amurensis. In this model, sucrose uptake, structure components production, intermediate matter changes, cell respiration loss and secondary metabolite (genistein) production were all predicted. The parameter sensitivity test was indicated that intermediate matter self-catalysis rate constant (k(b1)), structure component synthesis rate constant (k(b2)) and secondary metabolite synthesis rate constant (k(p)) were the most sensitive parameters for this model. If k(b1), k(b2) or k(p) are changed by 10%, the range of the aim function value would be changed by 12.8%, 4.61% and 2.54%, respectively. Adjustment of the other parameters only aroused a change of less than 0.5% in the aim function value. The predicted values were in good agreement with those obtained experimentally.
Cell Culture Techniques
;
Cells, Cultured
;
Kinetics
;
Maackia
;
cytology
;
Models, Biological
4.Surgical treatment for Lisfranc injuries accompanied by the base crashing of the second metatarsal bone.
Jie-feng HUANG ; Yang ZHENG ; Xin CHEN ; Kai ZHA ; Xi-wen DU ; Jun-jie CHEN ; Pei-jian TONG
China Journal of Orthopaedics and Traumatology 2015;28(2):171-173
OBJECTIVETo discuss the clinical effects of open reduction and internal fixation (ORIF) for treatment of patients with Lisfranc injury combined the second metatarsal base comminuted fracture.
METHODSFrom March 2007 to June 2012, 7 patients with Lisfranc injury combined the second metatarsal base comminuted fracture were treated including 5 males and 2 female aged from 22 to 51 years old (means 42 years), 4 of sprain and 3 of traffic injury. According Myerson classification, there was 1 case of type A, 3 of type B and 3 of type C. Kirschner wire was used to fix Lisfranc ligament placing from the medial cuneiform bone to the second metatarsal base during the operation. After the operation American Orthopaedic Foot and Ankle Society (AOFAS) criteria system were applied to evaluate the foot and ankle function. Preoperative and postoperative AP, lateral and oblique X-ray and CT scan were collected for radiographic evaluation.
RESULTSAll patients were followed up from 12 to 20 months (16.8 months in average). According to AOFAS criteria system, 3 cases were excellent result,3 good, 1 fair. All the wounds were primary healing without skin necrosis, infection, Kirschner loose,broken, or other complications.
CONCLUSIONKirschner wire had good clinical efficacy for fixing Lisfranc ligament injury with the second metatarsal base comminuted fracture, and could avoid arthrodesis.
Adult ; Bone Wires ; Female ; Humans ; Male ; Metatarsal Bones ; injuries ; surgery ; Middle Aged ; Tarsal Joints ; injuries ; surgery ; Wound Healing
5.Femoral revision of the hip: reason, type and different techniques
Shuo FENG ; Guo-Chun ZHA ; Kai-Jin GUO ; Xiang-Yang CHEN
Chinese Journal of Tissue Engineering Research 2018;22(15):2396-2406
BACKGROUND: Total hip arthroplasty has been widely used in clinical practice, and achieved good clinical efficacy. However, with the yearly increased number of patients receiving primary arthroplasty, the number of revision hip arthroplasty patients has increased. However, hip arthroplasty is one of the most difficult hip surgery, and it is challenging. OBJECTIVE: To review the causes of femoral revision of the hip arthroplasty, the classification of the femoral bone defect, and the type of prosthesis available in the clinical revision, and the clinical effect of the different prosthesis, so as to provide reference for femoral revision. METHODS: CNKI, Web of Science, and PubMed were searched for the literatures published between January 1975 and August 2017 with the key words of "Revision total hip arthroplasty, Femur revision, Cemented femoral revision, Cemenless femoral revision Reoperation, Porous-coated stems, Modular, tapered stem, Wagner SL revision Stem". RESULTS AND CONCLUSION: (1) A total of 1 041 articles were retrieved. After reading the abstract, unrelated and repeated studies were excluded. Finally, 109 studies were included. Of them, there were 106 English studies and 3 Chinese studies. Femoral revision was analyzed and summarized. (2) Femoral revision of the hip is still the future challenges facing the joint surgeon. We continue to strive to overcome the direction. Although the current material science and surgical technology are now rapidly developed, only the analysis of the reasons for the revision of the femoral side, identifying the femoral side bone defect classification, mastering the treatment of different defects and the application of the principle of prosthesis type, making reasonable femoral revision program is the key to success according to the patient's age and activity.
6.Accuracy and influencing factor of artificial intelligence planning system in patients undergoing total hip arthroplasty
Kai ZHANG ; Zhuotao GUO ; Qiaoqiao MA ; Guochun ZHA ; Kaijin GUO
Chinese Journal of Tissue Engineering Research 2024;28(12):1863-1868
BACKGROUND:Artificial intelligence planning system can automatically establish a three-dimensional model and generate planning schemes,but its accuracy in predicting the prosthesis size has not been fully verified. OBJECTIVE:To investigate the accuracy of artificial intelligence planning system in predicting prosthesis size before total hip arthroplasty and its influence on clinical prognosis,and further analyze the risk factors affecting the accuracy of planning. METHODS:Clinical data of patients with unilateral initial total hip arthroplasty who were admitted to the Department of Orthopedics of Affiliated Hospital of Xuzhou Medical University from January 2021 to June 2022 were prospectively collected.The patients were randomly divided into the artificial intelligence planning system group(n=80)and the conventional template group(n=79).Intraoperative use of prostheses and preoperative planning of prosthesis matching were compared between the two groups.Postoperative follow-up Harris scores and the occurrence of complications such as leg length discrepancy,dislocation and prosthesis loosening were recorded in both groups.The effects of demographic indicators,preoperative diagnosis,and Dorr typing on the accuracy of femoral stem planning were explored using univariate and multivariate Logistic regression analyses. RESULTS AND CONCLUSION:(1)The prediction of the prosthesis size on the acetabular side and femoral side was 50%(40/80)and 55%(44/80)in the artificial intelligence planning system group,compared to 34%(27/79)and 37%(29/79)in the conventional template group,with statistically significant differences(P<0.05).(2)The artificial intelligence planning system group had an accuracy rate within one size difference for the acetabular and femoral side prostheses of 91%(73/80)and 86%(69/80),compared to 82%(65/79)and 72%(58/79)in the conventional template group,with differences statistically different only on the femoral side(P<0.05).(3)No dislocation or prosthesis loosening occurred in the two groups during postoperative follow-up.The difference in lower limb length between the artificial intelligence planning system and conventional template groups was(3.56±2.32)mm and(3.52±2.41)mm.At the last follow-up,the Harris scores of the artificial intelligence planning system and conventional template groups were(92.74±3.08)and(91.81±3.52),respectively;there was no significant difference in the above differences(P>0.05).(4)Univariate analysis results showed that preoperative diagnosis as developmental dysplasia of the hip and osteonecrosis of the femoral head,and Dorr type B and C femurs had a significant effect on the accuracy of predicted prosthesis size using an artificial intelligence planning system(P<0.05).(5)Multivariate logistic regression analysis showed that preoperative diagnosis of developmental dysplasia of the hip(OR=18.233,95%CI:2.662-124.888)was an independent risk factor for the prediction of femoral stem size by artificial intelligence planning system.(6)The artificial intelligence planning system has a higher accuracy in predicting prosthetic size than traditional two-dimensional templates,and there is not a significant difference in the risk of postoperative complications or joint function.The accuracy of the artificial intelligence planning system in patients with developmental dysplasia of the hip was low due to anatomical deformities and acetabular anatomical position reconstruction.
7.Morphological changes of bone in the progress of rat chronic fluorosis
Shu-ling, FAN ; Sheng-bin, BAI ; Wen, QIN ; Ya-lou NG ZHA ; Jin-jie, ZHONG ; Rong, CHEN ; Tian, LI ; Shu-mei, FENG ; Kai-tai, LIU ; Xue-gang, LUO ; Long, CHEN ; Li-bin, LIAO
Chinese Journal of Endemiology 2012;31(2):151-155
ObjectiveTo observe the morphological changes of bone in the progress of chronic fluorosis.MethodsWistar rats were randomly divided into three groups,30 rats in each group:normal control group,experimental group Ⅰ and experimental group Ⅱ according to body weight.Rats in normal control group drank distilled water freely.Experimental group Ⅰ and group Ⅱ drunk distilled water with sodium fluoride preparation of fluorine containing ion 100,150 mg/L solution for six months,respectively.Bone mineral density was detected by X-ray,bone morphological changes were observed under light microscope and bone histomorphometric parameters were calculated using image analysis software.ResultsThe bone mineral density values were different statistically between the three groups after feeding for 2 and 4 months(F =19.79,3.28,all P < 0.05).However no significant difference was found after feeding for 6 months(F =1.80,P > 0.05).The bone mineral density of experimental group Ⅰ (0.20 ± 0.03,0.21 ± 0.03) was significantly higher than that of the normal control group(0.17 ± 0.03,0.20 ± 0.04) after feeding for 2 and 4 months.The bone mineral density of experimental group Ⅱ (0.21 ± 0.02) was lower than that of normal control group(0.22 ± 0.03) after feeding for 6 months.The bone lamella in experimental group Ⅰ was arranged disorderly,the number of osteocytes increased with their nucleus atrophy and the osteoblasts were more than that of control grouo which arranged in layers observed under light microscooy.In exoerimental group Ⅱ,the bone lamella was bent deformation,the number of osteocytes had decreased with their nucleus shrinking or even disappeared and the number of osteoclasts had increased significantly observed under light microscopy.In experimental group Ⅰ,the mean trabecular density [(0.33 ± 0.03)%] increased and the mean trabecular separation,thickness [( 163.57 ± 1.99),(59.26 ± 7.18 ) μm] decreased compared with that of normal control group [(0.31 ± 0.02)%,(186.60 ± 2.90)μm,(86.42 ± 1.48)μm,all P < 0.05].In experimental group Ⅱ,the mean trabecular density[(0.26 ± 0.02)%] decreased,the mean trabecular thickness[(71.42 ± 10.77)μm] reduced compared with that of normal control group[(0.31 ± 0.02)%,(86.42 ± 1.48)μm].ConclusionsExcess fluoride can damage bone tissue.Low doses of fluoride can stimulate osteoblast activity and enhance osteogenesis.The activity of osteoblasts is great than that of osteoclasts.High doses of fluoride can stimulate both osteoblasts and osteoclasts activity,but mainly the activity of osteoclasts,and bone resorption increases.
8.Detection of fluoride ion concentration in osteoblasts in vitro by nuclear magnetic resonance spectroscopy
Jin-jie, ZHONG ; Jin-yi, ZHONG ; Jing-quan, LIU ; Sheng-bin, BAI ; Shu-ling, FAN ; Ya-lou NG ZHA ; Shu-mei, FENG ; Wen, QIN ; Long, CHEN ; Tian, LI ; Li-bin, LIAO ; Kai-tai, LIU
Chinese Journal of Endemiology 2012;31(2):147-150
ObjectiveTo detect the concentration and distribution of fluoride ions in osteoblasts exposed to fluoride in vitro culture,and to provide basic information for studying the effect of fluoride on osteoblast injury.MethodsIn vitro cultured osteoblasts were exposed to 0,5,10,20,40 mg/L fluoride for 3,10,30 d (n =6),respectively.Concentration and distribution of fluoride ions in the cytoplasm and the nucleus of these osteoblasts were determined by nuclear magnetic resonance spectroscopy.Results(①) After cultured for 3 d,fluoride ion content of the bone cytoplasm exposed to different concentrations of fluoride 0,5,10,20,40 mg/L were (0.83 ±0.65),(0.54 ± 0.23),(0.65 ± 0.77),(0.59 ± 0.87),(3.64 ± 1.21 )mg/L,respectively,and the values of exposed to 40 mg/L fluoride group was significantly higher than that of exposed to 0,5 mg/L groups (all P < 0.05).(②)after cultured for 10 d,the composition of the fluoride ion in cytoplasm of exposed to fluoride 10,20,40 mg/L groups were (4.03 ± 1.23),(3.66 ± 0.98),(6.26 ± 2.10)mg/L,respectively,which were higher than that of exposed to 0,5 mg/L groups [(0.78 ± 0.75),(2.69 ± 0.89)mg/L,respectively,all P < 0.05].Of fluoride 20,40 mg/L groups,the composition of the fluoride ion in nucleus were (1.63 ± 1.19),(2.17 ± 1.21 )mg/L,respectively,which were higher than that of 0,5 mg/L groups[(0.65 ± 0.46),(1.57 ± 0.33) mg/L,all P < 0.05].(③)After cultured for 30 d,of the exposed to fluoride 10,20,40 mg/L groups,the composition of the fluoride ion in cytoplasm were (3.99 ± 0.84),(4.33 ± 1.67),(5.80 ± 1.38)mg/L,respectively,which were higher than that of 0,5 mg/L groups[(0.88 ± 0.44),(2.84 ± 0.43)mg/L,all P < 0.05].The composition of the fluoride ion in nucleus of the fluoride 20,40 mg/Lgroups were (3.33 ± 1.46),(3.53 ± 1.22)mg/L,respectively,which were significantly higher than that of 0,5mg/L groups [(0.70 ± 0.66),(1.99 ± 0.76)mg/L,all P < 0.05].ConclusionsWhen osteoblasts are exposed to fluoride environment,fluoride ions enter into the osteoblasts quickly,and quickly accumulate in the nucleus,showing a special affinity between fluoride and bone tissue.Intracellular fluoride ions increase with the increase of contact time and exposure dose.
9.Molecular evolution of Culex flavivirus in Gansu province in 2011 and 2019
Bin LI ; Bing ZHA ; Shihong FU ; Xueping XU ; Sichao YING ; Kai NIE ; Xingzhou LI ; Huanyu WANG ; Guodong LIANG
Chinese Journal of Experimental and Clinical Virology 2022;36(2):183-188
Objective:To disclose the molecular genetic differences of Culex flavivirus among mosquitoes in Gansu province in 2011 and 2019.Methods:Reverse transcriptase-polymerase chain reaction (RT-PCR) was used to obtain the nucleotide sequences of Culex flavivirus genomes from mosquitoes in Gansu province in 2011 and 2019, and viral molecular biology and bioinformatics method were used to analyze the genetic differences of the viruses.Results:Nucleotide sequences of 10 strains of Culex flavivirus were obtained, including 8 strains (all from Culex pipiens pallens) obtained in 2011 and 2 strains ( from Culex tritaeniorhynchus and Anopheles sinensis) in 2019. Homology analysis of nucleotide and amino acid sequences of virus E gene showed that the nucleotide sequence similarity and amino acid similarity of viruses isolated from Gansu in 2019 and 2011 ranged from 98.3%-100% and 95.4%-97.3%, respectively. Phylogenetic analysis of Culex flavivirus E gene sequence showed that two strains of Culex flavivirus isolated in Gansu province in 2019 (GS1975 and GS1976) and eight strains of Culex flavivirus isolated in 2011 all belonged to group B of genotype 1 of Culex flavivirus. Further analysis found that GS1975 virus isolated in 2019 was in a common evolutionary cluster with viruses isolated from Liaoning (2010 and 2011) and Inner Mongolia (2018), while GS1976 virus isolated in 2019 formed a coevolutionary cluster with viruses isolated from Inner Mongolia (2018) and Gansu (2011). Conclusions:Although both Culex flaviviruses isolated in Gansu province in 2011 and 2019 are genotype 1 virus, the two viruses isolated in 2019 distributed in two different evolutionary clusters, suggesting that the local mosquito virus genome changes over time, therefore, long-term monitoring of molecular differences is needed to carry out.
10.Pharmacokinetic study of Noiiglutide injection,INS068 injection and the compound preparation in Chinese healthy subjects
Xiao-Dong XING ; Ji-Gang ZHANG ; Kai SHEN ; Ming-Jian ZHANG ; Yi-Xin ZHA ; Shu-Jing JIN ; Mei XU ; Wen-Yuan XUE ; Xue-Ying DING
The Chinese Journal of Clinical Pharmacology 2023;39(23):3449-3454
Objective To compare the pharmaceutics and drug interactions of noiiglutide injection,INS068 injection,HR17031 Injection,and noiiglutide+INS068 injection in healthy subjects Methods This was a single center,randomized,open-label,4-cycle,4-cohort trial.Healthy subjects were allocated to 4 groups randomly.HR17031(17 U/0.04 mg),INS068(17 U),noliglycopeptide(0.04 mg),and INS068(17 U)combined with noiiglutide(0.04 mg)were injected subcutaneously into the abdomenon on day 1,8,15 and 22 respectively.Venous blood was collected at different timing before and after administration,and the concentrations of noiiglutide in plasma and INS068 in serum were measured by HPLC-MS/MS method.Relevant pharmacokinetic parameters were calculated using the WinNonlin non compartment model.Results In HR17031,INS068,and INS068 combined with noiiglutide groups,the main pharmacokinetic parameters of INS068 in serum were calculated and listed as follows:Cmax were(19.50±4.06),(18.10±4.56)and(18.40±5.81)ng·mL-1,tmax was 12,10 and 8 h,t1/2 was(9.27±1.70),(11.00±2.81)and(11.0±3.18)h,AUC0-twere(505.00±62.20),(498.00±70.50)and(491.00±74.20)ng·mL-1·h.In HR17031,noiiglutide,and INS068 combined with noiiglutide groups,the main pharmacokinetic parameters of noiiglutide in plasma were calculated and listed as follows:Cmax were(3.61±0.82),(4.63±0.87)and(4.54±0.86)ng·mL-1,tmax was all 8.00 h,t1/2 was(10.50±1.61),(9.49±1.40)and(9.55±1.61)h,AUC0-twere(94.30±20.10),(106.00±20.20)and(105.00±19.00)ng·mL-1·h.Conclusion There was no significant difference in bioavailability of INS068 and noiiglutide in HR17031 compared with INS068 and noiiglutide whether combined or used alone.