1.Relation of Cardiac Arrhythmias to Hypoxic Time and Lowest Oxygen Saturation in Patients with Obstructive Sleep Apnoea in an Asian Context: A Singapore Sleep Centre Study.
Adele Cw NG ; Wei Li NEO ; Mahalakshmi RANGABASHYAM ; Ying HAO ; Kah Leng HO ; Song Tar TOH
Annals of the Academy of Medicine, Singapore 2017;46(5):210-212
2.A tale of two tachycardias.
Colin YEO ; Jeremy CHOW ; Gerard LEONG ; Kah Leng HO
Singapore medical journal 2015;56(1):e10-3
A patient with non-ischaemic cardiomyopathy, and pre-existing atypical atrial flutter and left bundle branch block, developed broad complex tachycardia. In this unique and uncommon case of double tachycardia, we discuss the diagnostic approach of ventricular tachycardia in patients with broad complex tachycardia, and the use of different contemporary algorithms to help diagnose ventricular tachycardia and differentiate it from supraventricular tachycardia with aberrant conduction.
Algorithms
;
Atrial Flutter
;
complications
;
diagnosis
;
Bundle-Branch Block
;
physiopathology
;
Cardiomyopathies
;
complications
;
diagnosis
;
Diagnosis, Differential
;
Echocardiography
;
Electrocardiography
;
Humans
;
Male
;
Middle Aged
;
Tachycardia, Supraventricular
;
diagnosis
;
physiopathology
;
Tachycardia, Ventricular
;
diagnosis
;
physiopathology
3.Trends amongst implantable cardioverter defibrillator patients in a tertiary cardiac centre in Singapore from 2002 to 2011.
Daniel T T CHONG ; Boon Yew TAN ; Kah Leng HO ; Wee Siong TEO ; Chi Keong CHING
Annals of the Academy of Medicine, Singapore 2013;42(9):480-482
Aged
;
Cardiac Care Facilities
;
trends
;
Cardiac Resynchronization Therapy
;
trends
;
utilization
;
Cardiac Resynchronization Therapy Devices
;
trends
;
utilization
;
Death, Sudden, Cardiac
;
prevention & control
;
Defibrillators, Implantable
;
trends
;
utilization
;
Electric Countershock
;
trends
;
utilization
;
Female
;
Heart Failure
;
therapy
;
Humans
;
Male
;
Middle Aged
;
Retrospective Studies
;
Singapore
;
Stroke Volume
;
Tachycardia, Ventricular
;
therapy
;
Tertiary Care Centers
4.Initial experience of subcutaneous implantable cardioverter defibrillators in Singapore: a case series and review of the literature.
Tien Siang Eric LIM ; Boon Yew TAN ; Kah Leng HO ; Chuh Yih Paul LIM ; Wee Siong TEO ; Chi-Keong CHING
Singapore medical journal 2015;56(10):580-585
Transvenous implantable cardioverter defibrillators are a type of implantable cardiac device. They are effective at reducing total and arrhythmic mortality in patients at risk of sudden cardiac death. Subcutaneous implantable cardioverter defibrillators (S-ICDs) are a new alternative that avoids the disadvantages of transvenous lead placement. In this case series, we report on the initial feasibility and safety of S-ICD implantation in Singapore.
Adult
;
Death, Sudden, Cardiac
;
prevention & control
;
Defibrillators, Implantable
;
statistics & numerical data
;
Electrophysiology
;
Follow-Up Studies
;
Humans
;
Male
;
Middle Aged
;
Patient Safety
;
Prosthesis Implantation
;
Singapore
;
Tachycardia, Ventricular
;
Ventricular Fibrillation
5.Patient barriers to implantable cardioverter defibrillator implantation for the primary prevention of sudden cardiac death in patients with heart failure and reduced ejection fraction.
Laura Lihua CHAN ; Choon Pin LIM ; Soe Tin AUNG ; Paul QUETUA ; Kah Leng HO ; Daniel CHONG ; Wee Siong TEO ; David SIM ; Chi Keong CHING
Singapore medical journal 2016;57(4):182-187
INTRODUCTIONDevice therapy is efficacious in preventing sudden cardiac death (SCD) in patients with reduced ejection fraction. However, few who need the device eventually opt to undergo implantation and even fewer reconsider their decisions after deliberation. This is due to many factors, including unresolved patient barriers. This study identified the factors that influenced patients' decision to decline implantable cardioverter defibrillator (ICD) implantation, and those that influenced patients who initially declined an implant to reconsider having one.
METHODSA single-centre survey was conducted among 240 patients who had heart failure with reduced ejection fraction and met the ICD implantation criteria, but had declined ICD implantation.
RESULTSParticipants who refused ICD implantation were mostly male (84%), Chinese (71%), married (72%), currently employed (54%), and had up to primary or secondary education (78%) and monthly income of < SGD 3,000 (51%). Those who were more likely to reconsider their decision were aware that SCD was a consequence of heart failure with reduced ejection fraction, knowledgeable of the preventive role of ICDs, currently employed and aware that their doctor strongly recommended the implant. Based on multivariate analysis, knowledge of the role of ICDs for primary prophylaxis was the most important factor influencing patient decision.
CONCLUSIONThis study identified the demographic and social factors of patients who refused ICD therapy. Knowledge of the role of ICDs in preventing SCD was found to be the strongest marker for reconsidering ICD implantation. Measures to address this information gap may lead to higher rates of ICD implantation.
Cross-Sectional Studies ; Death, Sudden, Cardiac ; prevention & control ; Defibrillators, Implantable ; Female ; Heart Failure ; mortality ; physiopathology ; therapy ; Humans ; Male ; Middle Aged ; Primary Prevention ; methods ; Risk Factors ; Singapore ; epidemiology ; Stroke Volume ; physiology ; Survival Rate ; trends
6.Non-fluoroscopic navigation systems for radiofrequency catheter ablation for supraventricular tachycardia reduce ionising radiation exposure.
Jason SEE ; Jonah L AMORA ; Sheldon LEE ; Paul LIM ; Wee Siong TEO ; Boon Yew TAN ; Kah Leng HO ; Chee Wan LEE ; Chi-Keong CHING
Singapore medical journal 2016;57(7):390-395
INTRODUCTIONThe use of non-fluoroscopic systems (NFS) to guide radiofrequency catheter ablation (RFCA) for the treatment of supraventricular tachycardia (SVT) is associated with lower radiation exposure. This study aimed to determine if NFS reduces fluoroscopy time, radiation dose and procedure time.
METHODSWe prospectively enrolled patients undergoing RFCA for SVT. NFS included EnSiteTM NavXTM or CARTO® mapping. We compared procedure and fluoroscopy times, and radiation exposure between NFS and conventional fluoroscopy (CF) cohorts. Procedural success, complications and one-year success rates were reported.
RESULTSA total of 200 patients over 27 months were included and RFCA was guided by NFS for 79 patients; those with atrioventricular nodal reentrant tachycardia (AVNRT), left-sided atrioventricular reentrant tachycardia (AVRT) and right-sided AVRT were included (n = 101, 63 and 36, respectively). Fluoroscopy times were significantly lower with NFS than with CF (10.8 ± 11.1 minutes vs. 32.0 ± 27.5 minutes; p < 0.001). The mean fluoroscopic dose area product was also significantly reduced with NFS (NSF: 5,382 ± 5,768 mGy*cm2 vs. CF: 21,070 ± 23,311 mGy*cm2; p < 0.001); for all SVT subtypes. There was no significant reduction in procedure time, except for left-sided AVRT ablation (NFS: 79.2 minutes vs. CF: 116.4 minutes; p = 0.001). Procedural success rates were comparable (NFS: 97.5% vs. CF: 98.3%) and at one-year follow-up, there was no significant difference in the recurrence rates (NFS: 5.2% vs. CF: 4.2%). No clinically significant complications were observed in both groups.
CONCLUSIONThe use of NFS for RFCA for SVT is safe, with significantly reduced radiation dose and fluoroscopy time.
Adolescent ; Adult ; Aged ; Aged, 80 and over ; Catheter Ablation ; methods ; Child ; Female ; Fluoroscopy ; Humans ; Male ; Middle Aged ; Prospective Studies ; Radiation Dosage ; Radiation, Ionizing ; Tachycardia, Atrioventricular Nodal Reentry ; therapy ; Tachycardia, Supraventricular ; therapy ; Treatment Outcome ; Young Adult
7.Remote monitoring of patients with cardiac implantable electronic devices: a Southeast Asian, single-centre pilot study.
Paul Chun Yih LIM ; Audry Shan Yin LEE ; Kelvin Chi Ming CHUA ; Eric Tien Siang LIM ; Daniel Thuan Tee CHONG ; Boon Yew TAN ; Kah Leng HO ; Wee Siong TEO ; Chi Keong CHING
Singapore medical journal 2016;57(7):372-377
INTRODUCTIONRemote monitoring of cardiac implantable electronic devices (CIED) has been shown to improve patient safety and reduce in-office visits. We report our experience with remote monitoring via the Medtronic CareLink(®) network.
METHODSPatients were followed up for six months with scheduled monthly remote monitoring transmissions in addition to routine in-office checks. The efficacy of remote monitoring was evaluated by recording compliance to transmissions, number of device alerts requiring intervention and time from transmission to review. Questionnaires were administered to evaluate the experiences of patients, physicians and medical technicians.
RESULTSA total of 57 patients were enrolled; 16 (28.1%) had permanent pacemakers, 34 (59.6%) had implantable cardioverter defibrillators and 7 (12.3%) had cardiac resynchronisation therapy defibrillators. Overall, of 334 remote transmissions scheduled, 73.7% were on time, 14.5% were overdue and 11.8% were missed. 84.6% of wireless transmissions were on time, compared to 53.8% of non-wireless transmissions. Among all transmissions, 4.4% contained alerts for which physicians were informed and only 1.8% required intervention. 98.6% of remote transmissions were reviewed by the second working day. 73.2% of patients preferred remote monitoring. Physicians agreed that remote transmissions provided information equivalent to in-office checks 97.1% of the time. 77.8% of medical technicians felt that remote monitoring would help the hospital improve patient management. No adverse events were reported.
CONCLUSIONRemote monitoring of CIED is safe and feasible. It has possible benefits to patient safety through earlier detection of arrhythmias or device malfunction, permitting earlier intervention. Wireless remote monitoring, in particular, may improve compliance to device monitoring. Patients may prefer remote monitoring due to possible improvements in quality of life.
Aged ; Arrhythmias, Cardiac ; diagnosis ; Defibrillators, Implantable ; Female ; Follow-Up Studies ; Humans ; Male ; Middle Aged ; Monitoring, Physiologic ; methods ; Pacemaker, Artificial ; Patient Safety ; Pilot Projects ; Prospective Studies ; Quality of Life ; Remote Consultation ; methods ; Singapore ; Surveys and Questionnaires