1.A clinical analysis on unresectable stomach cancer.
Kab Seung JEON ; Eil Sung CHANG
Journal of the Korean Surgical Society 1991;40(5):571-580
No abstract available.
Stomach Neoplasms*
;
Stomach*
2.Reactivity Patterns of Various Anti-D Reagents in 14 Cases with Partial D.
Duck CHO ; Gyeong Ran CHOI ; Mee Juhng JEON ; Kab Soog KIM ; Jin Young SEO ; Myung Geun SHIN ; Soo Hyun KIM ; Seung Jung KEE ; Jong Hee SHIN ; Soon Pal SUH ; Dong Wook RYANG
The Korean Journal of Laboratory Medicine 2003;23(6):443-447
BACKGROUND: A weak D type resulted from a quantitative reduction of the RhD antigen, whereas a partial D type resulted from a qualitatively altered RhD protein. Based on different serological properties from a weak D type, a partial D type was suspected in cases with anti-D in their serum or if nonreactive to some reagents. Most Red Cross Blood Centers pay attention to donors in determining RhD typing with a monoclonal anti-D reagent. This study examined the reactivity patterns of 4 different monoclonal anti-D reagents in RhD typing and a weak D test in 14 cases with partial D. MATERIALS AND METHODS: We collected a total of 201, 847 samples from blood donors and screened out 649 samples as Rh-negative in RhD typing with monoclonal anti-D (Bioscot) and bromelin treatment applied to an automatic analyzer between October 2002 and March 2003. Further, we performed RhD typing and weak D test using the tube method with 4 commercially available monoclonal anti-D reagents. In 14 cases with different reactivity patterns, we performed a confirming test for partial D using a `ID-partial RhD-typing' (Diamed, Switzerland) set consisting of 6 monoclonal antibodies. RESULTS: Partial D(DFR) was observed in 92.9% (13/14) and a partial D(indeterminate) was observed in 7.1% (1/14). The red blood cells from 14 cases with partial D were not agglutinated with 4 various commercially available anti-D reagents. However, in subsequently performed weak-D tests, different reactivity to their anti-D reagents were shown, namely irresponsiveness (Dade Behring, 14/14, 100%), trace-to-1+ responsiveness (Ortho-clinical diagnostics, 13/14, 92.9%), trace-to-3+ responsiveness (Bioscot, 14/14, 100%), and 1+-to-3+ responsiveness (GreenCross, Korea, 14/14, 100%). CONCLUSIONS: Considering that the most partial D discovered in the Southwestern area of Korea was partial D(DFR), it is recommended that RhD typing and/or weak D tests in blood donors should be done using more than two anti-D reagents from different clones.
Antibodies, Monoclonal
;
Blood Donors
;
Bromelains
;
Clone Cells
;
Erythrocytes
;
Humans
;
Indicators and Reagents*
;
Korea
;
Red Cross
;
Tissue Donors