1.The observation of the artificial hip arthroplasty in the treatment of elderly patients with femoral neck fracture
Chinese Journal of Primary Medicine and Pharmacy 2012;19(10):1474-1475
ObjectiveTo investigate the effect of hip arthroplasty(THA or HHA) and routine internal fixation in the treatment of elderly patients with femoral neck fracture.Methods158 elderly patients with femoral neck fracture were randomly divided into 3 groups.55 cases of them(THA group) were treated with THA,60 cases of them ( HHA group) were treated with HHA,while 43 cases of them ( control group) were treated with internal fixation.Blood loss,operation time,and bed in time,as well as the range of movement (ROM) of hip,Harris score and VAS score were observed.ResultsOperation time and blood loss in THA group and HHA group were more than that in control group(P <0.05 ),and the operation time in control group was the least.Bed in time of THA group and HHA group were all less than that of control group significantly( P < 0.05 ).ROM of hip in THA and HHA group were larger than that in control group significantly(P <0.05).And the Harris score in THA group was more than that in other two groups (P < 0.05 ).ConclusionCompared with internal fixation,arthroplasty was more effective in the treatment of elderly patients with femoral neck fracture.
2.A Study of Hemorrheological Changes in Patients with Severe Viral Hepatitis
Yuming WANG ; Xianyu LI ; Juzheng XIANG ; Shiqi HU
Journal of Third Military Medical University 1983;0(04):-
This paper is to report the study of the microscopic and macroscopic he-morrheological changes and the conditions of the nail-fold microcirculation in 30 patients with severe viral hepatitis. Normal 'individuals, patients with acute icteric hepatitis, and those with chronic active hepatitis were employed as the controls.The changes observed in the patients with severe viral hepatitis were as follows: The reduced viscosity of the whole blood and the plasma viscosity increased markedly, the dispersion rate of the blood viscosity values increased as the clinical state of the patient became more severe, and the factors increasing the blood viscosity (namely, increase of the amount of immune globulin, pro-longation of the electrophoretic time of RBC, increase of RBC sedimentation rate), and the factors decreasing the blood viscosity (namely, decreases of he-matocrit reading, fibrinogen, and the aggregation ratio of platelets) existed simultaneously. The changes of the flow condition and velocity of the nail-fold microcirculation were in close correlation with the increase of blood viscosity and the severity of the disease.The causes and the mechanism of the above-mentioned changes were discussed.
3.Minimally invasive posterior reconstructive plating by parallel Kirschner wires for unstable posterior pelvic fractures
Chengming ZHU ; Zhanying SHI ; Juzheng HU ; Renchong WANG ; Jianming HE ; Yongbao QIN
Chinese Journal of Orthopaedic Trauma 2019;21(6):504-510
Objective To explore the clinical efficacy of minimally invasive posterior reconstructive plating by parallel Kirschner wires in the treatment of unstable posterior pelvic fractures.Methods From January 2013 to December 2016,29 patients with unstable posterior pelvic fracture were treated at Trauma Center,Liuzhou Workers' Hospital.They were 22 men and 7 women,aged from 19 to 65 years (mean,44.2 years).By the Tile classification,10 cases were classified as type B and 19 as type C.The delay from injury to surgery ranged from 4 to 14 days (mean,8.7 days).All the patients received minimally invasive posterior fixation with a U-shaped reconstructive plate and parallel Kirschner wires.The length of incision,intraoperative bleeding,operation time,quality of fracture reduction,curative effects and complications at the last follow-up were recorded.Results The length of intraoperative unilateral incision ranged from 2.3 to 3.4 cm (average,2.99 cm);the volume of intraoperative bleeding ranged from 47 to 88 mL (average,69.9 mL);the average operation time ranged from 17 to 34 min (average,25.2 min).One patient was lost to the follow-up.The other 28 patients were followed up for 14 to 26 months (average,18.3 months).The fracture healing time ranged from 8 to 15 months (average,10.1 months).According to the Matta criteria for fracture reduction,17 cases were rated as excellent at the last follow-up,9 as good,one as fair and one as poor,giving an excellent to good rate of 92.9%.According to the Pohlemann functional scoring,14 cases were rated as excellent,11 as good,2 as fair and one as poor,giving an excellent to good rate of 89.3%.Conclusion In the treatment of unstable posterior pelvic fractures,minimally invasive posterior reconstructive plating by parallel Kirschner wires presents advantages of high security,limited surgical trauma,good curative effects and limited postoperative complications.
4.A comparative study of orthopaedic robot and O-arm navigation to pelvic fractures
Chengzhi YANG ; Zhanzhu HUANG ; Jingli TANG ; Dan ZHOU ; Jianming HE ; Juzheng HU ; Zhanying SHI
Chinese Journal of Orthopaedics 2021;41(19):1387-1395
Objective:By comparing the clinical effect of minimally invasive hollow screw internal fixation Assisted by orthopedic robot (TiRobot) and O-arm navigation in the treatment of pelvic fractures, and practicability and security of both treatments were evaluated.Methods:Retrospective analysis of data of 42 cases of Tile C type pelvic fractures was employed during June 2017 to June 2020. Among them, 32 cases, twenty-four men, eight women, aged 34±6.2 years (range 24-68 years), were treated with percutaneous screw fixation guided by O-arm X wire instrument. According to Tile classification, there were 3 cases of C1.1 type, 8 cases of C1.2 type and 21case of C1.3 type. According to the Denis classification of sacral fractures, 17 cases were in zone I, and 8 cases in zone II. Ten patients, eight males and two females, aged 36±5.2 years (range 19-62 years) were treated by percutaneous screw fixation assisted by orthopedic robot. According to Tile classification, there were 1 case of C1.1 type, 2 cases of C1.2 type and 7 cases of C1.3 type. According to the Denis classification of sacral fractures, there were 5cases in zone I, 2 cases in zone II. For those who got obviously displaced pelvic fractures, Starr frames were used and then internal fixation was used to fix pelvic anterior ring and posterior ring injury respectively. Based on the times of needle adjustments, intraoperative fluoroscopy time, good screw position and incidence of complications two groups were statistically analysed. Matta score was employed to evaluate the quality of fracture reduction, while the Majeed score was employed to evaluate the clinical efficacy. Through the two groups of cases guide needle adjustment times, intraoperative fluoroscopy time, screw position excellent and good rate and the incidence of complications, which were statistically analyzed.Results:All screw positions were confirmed by CT scan after operation. The average time required for each screw placement of the O-arm group was 7.36±2.63 s, of the robot group was 6.80±3.20 s, so difference was not statistically significant ( P<0.05). An average of screw adjustments per one screw was 1.56±0.02 times by O-arm, and by the robot group was 0.34±0.06 times, so differences between the two groups were statistically significant ( P>0.05). The average operating time of O-arm group was 53.86±15.06 min, while the robot group was 52.52±15.14 min, so differences between the two groups were not statistically significant ( P>0.05). Position distribution of screw placement in two groups, all screws in O-arm group of position evaluations were excellent, excellent rate was 100%, all screw position evaluations by robot were excellent, excellent rate was 100%, so difference in screw distribution between the two groups was not statistically significant ( P>0.05). All cases were followed up for 6-12 months. Fracture healing time: 34.6±8.6 weeks for O-arm group, 33.4±9.4 weeks for robot group. Comparison between the two groups was not statistically significant ( P>0.05). Majeed score of O-arm group was 55-87, including Excellence of 17 cases, goodness of 9, fairness of 6. The rate of excellence and goodness was 81.2%, while robot group was 76-95, and that were excellent 7 cases,1 good, and the excellent and good rate was 80%, there was no significant difference between Matta and Majeed score between the two groups ( P>0.05). The incidence of complications between the two groups were no statistically significant ( P>0.05). Conclusion:Orthopedic robot system and O-arm navigation system assisted by percutaneous hollow screw fixation treatment of pelvic anterior and posterior ring injury, which are accurate, safe, minimally invasive, can reduce radiation damage to patients and surgeons. The efficacy were satisfactory. Both treatments are ideal for minimally invasive treatment of pelvic fractures, and the orthopedic robot have advantages of being programmed, standardized, stable and it’s learning curve is shorter.
5. Preliminary application of Starr reduction framecombined with O-arm navigation systemin the treatment ofcomplex pelvic fractures
Juzheng HU ; Zhanying SHI ; Renchong WANG ; Hao WU ; Haiwei YAN ; Zhanzhu HUANG ; Chunhua MAO ; Dan ZHOU ; You XIE
Chinese Journal of Orthopaedics 2019;39(13):817-825
Objective:
To investigate the feasibility and short term clinical efficacy of early minimally invasive treatment of complex pelvic trauma with Starr reduction frame combined with O-arm navigation system.
Methods:
From June 2017 to December 2018, thirty two patients with Tile C complex pelvic fractures were prospectively divided into two groups according to the random number table. The open treatment group included 17 cases (open reduction and internal fixation group; 10 males and 7 females, age 24-60 years, average 37±6.5 years; according to Tile classification, 8 cases of C1 type, 8 cases of C2 type and 1 case of C3 type; according to the Denis classification of sacral fractures, 9 cases in zone I, 6 cases in zone II and 2 cases in zone III). The combined treatment group included 15 cases (Starr reduction frame group combined with O-arm navigation system, 8 males and 7 females, age 32-57 years, average 40±5.2 years; according to Tile classification, 8 cases of C1 type, 6 cases of C2 type and 1 case of C3 type; according to the Denis classification of sacral fractures, 8 cases in zone I, 5 cases in zone II and 2 cases in zone III). The ilioinguinal and Stoppa approaches were used in the open treatment group, and the anterior and posterior ring injuries were fixed with reconstruction plate screws and hollow screws, respectively. In the combined treatment group, starr frame was used to assist reduction, combined with "O" arm navigation technique, infix internal fixation frame, superior pubic branch screw, sacroilium screw were used to fix the anterior and posterior ring injury. The quality of pelvic fracture reduction was evaluated by the Matta scoring system, and the Majeed score was used to evaluate the clinical efficacy.
Results:
All patients were followed up for 6 to 12 months. The hospitalization time (45±11 d), operation time (220.0±49.4 min) and fracture healing time (24.0±5.6 weeks) in the open treatment group were longer than those in the combined treatment group (21±9 d, 180.0±24.2 min, 16.1±3.8 weeks), and the intraoperative blood loss (820.0±140.4 ml) was significantly higher than that in the combined treatment group (24.0±10.4 ml)(
6.Design and finite element analysis of a new type of plate for hyperextension varus tibial plateau fractures
Zhongshuai LIANG ; Renchong WANG ; Lu ZHANG ; Juzheng HU ; Zhanying SHI ; You XIE ; Chunhua MAO
Chinese Journal of Tissue Engineering Research 2024;33(33):5283-5288
BACKGROUND:There is currently no anatomic locking plate suitable for the anteromedial platform,so the medial locking plate of the tibial plateau is usually placed forward to fix anteromedial compression fractures caused by hyperextension varus injury.Due to the inability of the locking screw to achieve vertical fixation of the fracture line,coupled with the influence of the patellar ligament,the clinical results are still unsatisfactory. OBJECTIVE:To compare the biomechanical performance of a new type of plate with traditional internal fixation methods in treating hyperextension varus tibial plateau fractures through finite element analysis. METHODS:CT data of 20 cases of hyperextension varus tibial plateau fractures were collected,and their morphological characteristics,such as medial posterior tibial slope,the medial articular fracture angle,surface area,and anterior cortical height were measured.A 24-year-old male volunteer with a height of 175 cm and a weight of 65 kg was selected,and his tibial CT data were imported into Mimics 21.0 software to generate a 3D model.Then,internal fixation models were imported into SolidWorks 2017 software.New type of plate,medial locking plate,posterior medial locking plate,and 6.5 mm hollow screws fixed data models were established based on the measured morphological data.Ansys 17.0 software was used to load stress on the four fixation models and compare their biomechanical performance. RESULTS AND CONCLUSION:(1)With the increase of axial load,the peak stresses of different internal fixation models approximately increased proportionally.At 500 N,the peak stress values were as follows:screw group(6.973 7 MPa)
7.Treatment of acromioclavicular joint dislocation with double Endobutton internal fixation assisted by orthopaedic robot
Chengzhi YANG ; Renchong WANG ; Huizhen ZENG ; Xiangtao XIE ; Jian XU ; Jingli TANG ; Hao WU ; Bing LI ; Juzheng HU
Chinese Journal of Orthopaedics 2022;42(21):1423-1432
Objective:To investigate the early clinical effects of orthopedic surgery robot-assisted double Endobutton titanium plate internal fixation in the treatment of fresh acromioclavicular joint dislocation.Methods:Thirty-nine patients with fresh acromioclavicular joint dislocation were included from January 2020 to January 2022. A total of 19 patients were treated with double Endobutton suspension internal fixation assisted by the domestic third-generation orthopaedic surgical robot (TiRobot ? 2.0) Dimensity system. There were Rockwood type III in 11 cases, type IV in 8 cases. Twenty cases were treated with conventional incision double Endobutton internal fixation, with Rockwood type III in 13 cases, type V in 7 cases. The operation duration, blood loss volume, incision length and hospitalization time were compared between the two groups. The following CT parameters of acromioclavicular joint at 2 days and 1 year after operation, distance between distal inferior cortex of clavicle and subacromial cortex, distance between upper and lower endobuttons, horizontal distance between anterior edge of distal clavicle and anterior edge of acromion and diameter of coracoid process and diameter of clavicular tunnel were measured. The visual analogue score (VAS), Constant-Murley shoulder function score and shoulder abduction activity were also evaluated before and at 12 months after operation. Results:The follow-up duration was 10.8±2.4 months in the robot group and 11.5±3.1 months in the routine group. The VAS score of the robot group decreased from 5.3±2.1 to 0.3±0.2 at 12 months after operation ( t=10.46, P=0.014). The Constant-Murley score increased from 55.6±6.4 to 92.0±4.2. The range of shoulder abduction increased from 42.2°±5.4° to 172.6°±6.1° ( t=17.24, P<0.001). The operation duation of the robot group was 74.4±6.6 min, which was longer than that of the conventional group 61.7±7.2 min ( t=5.43, P=0.037). There was no significant difference in VAS score, Constant-Murley score, shoulder abduction activity or CT measurement between the two groups ( P>0.05). During the follow-up, two cases in the robot group had cortical osteolysis on the supraclavicular surface, one case in the conventional group had loss of reduction, one case in the supraclavicular cortical osteolysis, and 4 cases in the cortical defect on the side of the coracoid process tunnel. Conclusion:Orthopedic robot-assisted and conventional incision with double Endobutton titanium plate internal fixation in treating fresh acromioclavicular joint dislocation can achieve satisfied early clinical effects. Accurate establishment of clavicle and coracoid bone tunnel assisted by robot can overcome the defects of bone tunnel deviation in conventional incision operation and can prevent reduction and bone loss. However, robot-assisted and conventional incision Endobutton internal fixation could enlarge bone tunnel.
8.Clinical study of bone transport combined with bone graft and internal fixation at the docking site in the treatment of large segmental bone defect in lower limb
Juzheng HU ; Zhanying SHI ; Chengzhi YANG ; Renchong WANG ; Hao WU ; Chengming ZHU ; You XIE ; Chunhua MAO
Chinese Journal of Orthopaedics 2018;38(5):280-287
Objective To explore the feasibility and clinical value of Ilizarov bone transport technique combined with bone graft and internal fixation at the docking site in the treatment of large segmental bone defect of the lower limbs.Methods Thirty patients with large lower limbs bone defects were prospectively divided into two groups according to the random number table:pure bone transport group (Ilizarov bone transport technique alone,n=lS,10 males and 5 females,average age 34.4±4.6 years old,2 cases bone defect of femur,13 cases tibia,and the length of bone defect 6.2±2.4 cm),and combined bone transport group (Ilizarov bone transport technique with bone graft and internal fixation at the docking site,n=lS,12 males and 3 females with the average age of 33.8±5.2 years,1 case of bone defect and 14 tibia,and the length of bone defect 6.5±2.2 cm).The preoperative hospital for special surgery (HSS) knee functional scores,Baird-Jackson ankle function scores,external fixation time,external fixation index,bone union time,bone union index,postoperative ASAMI scores and incidence of complications were compared between the two groups.Results All patients were followed up for 9 to 24 months (mean 16.2 months).Pure bone transport group was followed up for 9 to 24 months (mean 16.2 months),and combined bone transport group was 10 to 24 months (mean 16.4 months).In pure bone transport group,the external fixation time was 17.6±5.4 months,and the bone union time was 11.2±3.1 months with the average bone union index 42.4±4.6 d/cm.While in combined bone transport group,the external fixation time of group B was 8.4± 2.1 months,and the bone union time was 7.2±2.1 months with the average bone union index 21.1±2.7 d/cm.The external fixation index of pure bone transport group was 32.4±2.1 d/cm,while in combined bone transport group it was 32.1±2.5 d/cm,and there was no significant difference between these two groups (t=0.812,P=0.884).According to the bone and function score of the ASAMI,in pure bone transport group,bone healing:excellent 6 cases,good 6 cases,fair 2 cases,poor 1 case,excellent rate was 80%.While in combined bone transport group:excellent in 8 cases,good 6 cases,fair 1 case,excellent rate was 93.3%.The difference between the two groups was statistically significant (X2=10.6,P=0.032).The lower limb function in pure bone transport group:excellent in 5 cases,good in 5,fair in 4,poor in 1,excellent rate was 66.7%;while in combined bone transport group:excellent in 6 cases,good in 7,fair in 2,excellent rate was 86.7%.There was also a significant difference in the incidence of complications between the two groups.Conclusion Both the pure Ilizarov bone transport technique and the Ilizarov technique with bone graft and internal fixation at the docking site could satisfactorily treat the large bone defect and shortening of the lower limb.But the latter technique had shorter healing time,higher healing rates,better limb function and fewer complications.
9.Treatment of acetabular anterior column fracture with percutaneous screw fixation with laser-assisted axial fluoroscopy
Juzheng HU ; Zhanying SHI ; Renchong WANG ; Hao WU ; You XIE ; Chunhua MAO ; Boyu LIU ; Jingli TANG ; Chengming ZHU ; Dan ZHOU ; Bing LI
Chinese Journal of Orthopaedics 2020;40(5):302-309
Objective:To investigate the feasibility and clinical efficacy of percutaneous screw fixation for acetabular anterior column fracture with laser-assisted axial fluoroscopy.Methods:Data of 20 patients (22 sided) with acetabular anterior column fracture treated by percutaneous screw fixation with laser-assisted axial fluoroscopy from January 2017 to December 2018 were retrospectively analyzed. There were 11 males and 9 females with an average of 42.1±3.2 years (range, 24-68 years). There were 7 cases of unilateral acetabular anterior column fracture, 2 cases of bilateral acetabular anterior column fracture (4 sides), 7 cases of anterior column with ipsilateral sacral fracture, and 4 cases of anterior column with sacroiliac joint injury. There were 3 hips of Area I, 6 Area II, 13 Area III of acetabular anterior column fractures according to Nakatani partition. The time from injury to surgery was 5 days (range, 3-11 days). All patients with acetabular anterior column fractures were fixed by percutaneous screw fixation with laser-assisted axial fluoroscopy, and patients with sacral fracture or sacroiliac joint injury were fixed by percutaneous sacroiliac screws with Starr frame-assisted reduction. The time of operation, the number of intraoperative fluoroscopy and the amount of intraoperative bleeding were recorded. Matta scoring criteria were used to assess fracture reduction quality, and hip function was assessed at the last follow-up according to the modified Merle D' Aubigné and Postel scoring system.Results:The average operative time was 22±10 min (range, 20-40 min) with an average times of intraoperative fluoroscopy of 30±8 times (range, 21-45 times), and the amount of intraoperative blood loss was 20±5 ml (range, 10-40 ml). 20 patients were followed up after operation for a period of 14±3.1 months (range, 12-18 months). The quality of postoperative fracture reduction was assessed according to the Matta acetabular fracture reduction criteria: anatomical reduction in 18 hips, satisfactory reduction in 2 hips, unsatisfactory reduction in 2 hips, with an excellent and good rate of 91% (20/22). The fracture healing time was 13±2.2 weeks (range, 11-16 weeks). At the lastest follow-up, hip function was assessed according to the modified Merle D' Aubigné and Postel scoring system: excellent 18, good 3, fair 1, and the satisfactory rate was 95%(21/22). No major neurological, vascular injury, wound infection and ectopic ossification were found during follow-up.Conclusion:Using laser-assisted axial fluoroscopy percutaneous screw to treat acetabular anterior column fracture, the operation is simple. And there is low risk to damage important blood vessels and nerves. This method can shorten the operation time of acetabular anterior column fracture, reduce the amount of blood loss during the operation, and the outcome is satisfactory.
10. Minimal invasive subcutaneous internal fixator in treatment of anterior pelvic ring instability-analysis of effects and complications
Haiwei YAN ; Juzheng HU ; Ying YANG ; You XIE ; Zhanzhu HUANG ; Xiaosong CHENG ; Lu WEI ; Yansong FENG ; Boyu LIU ; Zhanying SHI
Chinese Journal of Orthopaedics 2019;39(13):826-832
Objective:
To investigate the incidence of complications following minimal invasive subcutaneous internal fixator (INFIX) for the treatment of anterior pelvic ring instability, and to analyze control measures.
Methods:
Data of 42 patients with anterior pelvic ring instability who were treated by anterior subcutaneous internal fixation in our hospital from January 2016 to December 2017 were retrospectively analyzed. There were 15 females and 27 males with an average age of 45.4 years (range, 18-67 years). There were 26 traffic injuries, 10 falling injuries, 3 crush injuries and 3 low energy injuries. According to Tile classification, 24 cases of B2 type, 16 cases of B3 type, 1 case of C1 type and 1 case of C2 type. According to Young-Burgess classification, there were 20 cases of LCI, 18 cases of LCII, 1 case of LCIII, 1 case of APCI, 1 case of APCII, and 1 case of VS. Fourteen cases were combined with limb fractures, and 11 cases were combined with thoracic or abdominal injuries requiring surgical treatment, while 16 cases were with brain injuries. For type APC2, LC1, and some LC2 fractures, fixation for the anterior pelvic ring is enough with INFIX technique alone. For some LC2, LC3, or VS fractures, the anterior and posterior ring were both fixed. Postoperative reduction was evaluated by Matta radiological criteria. Lateral thigh numbness and pain, quadriceps muscle power were recorded during follow-up, and clinical efficacy was evaluated by Majeed score at 6 months after operation.
Results:
All the 42 patients were followed up for 6 to 12 months, with an average of 9.3 months. Matta standard evaluation for fracture reduction showed that 28 cases were excellent, 14 cases good, and the excellent and good rate was 100%. The early complication rate (within 3 month after operation) was 23.8% (10/42) including 6 cases of lateral femoral cutaneous nerve injury and 2 cases of femoral nerve injury. The symptoms were obviously relieved after the treatment of nutrient nerve and hyperbaric oxygen; 1 case had incision infection which was healed after anti-infection therapy and internal plant removal; 1 case suffered from superior gluteal artery injury which was controlled by pressure hemostasis. Six months after surgery, no case had lost reduction. At 6 months follow-up, the Majeed score was 72-96, with an average of 84.96, of which 32 were excellent and 10 were good, thus the excellent and good rate was 100% (42/42).
Conclusion
INFIX is an effective internal fixation method for the treatment of unstable anterior pelvic ring injury. However, it has a high rate of early complications, among which nerve injury has the highest incidence.