1.Measurement of Left Ventricular Diastolic Function with Color M-mode Echocardiography in Patients with Acute Coronary Syndrome.
Juyup HAN ; Yongwhi PARK ; Donghun YANG ; Youngbae SEO ; Hunsik PARK ; Shungchull CHAE ; Jaeeun JUN ; Ehyun PARK
Journal of the Korean Society of Echocardiography 2001;9(2):97-104
BACKGROUND: Color M-mode doppler echocardiography has been suggested as a new noninvasive technique for assessing left ventricular diastolic function. The present study was performed to define the feasibility and value of color M-mode echocardiography for the assessment of left ventricular diastolic function in patients with acute coronary syndrome. METHODS: Thirty six patients with acute myocardial infarcion and twenty three patients with unstable angina were included (M/F=41/18, 61+/-12.2 years). Doppler study was performed using ATL HDI-3000 within 24 hours after the attack. In color M-mode study, ROP was measured with 'Front wave method' and 'Baseline shift method'. The patients were grouped into three groups based on E/A ratio and deceleration time (DT) in transmitral flow and S/D ratio in pulmonary venous flow; Group I=Normal pattern (E/A>1, S/D>1, DT>140 ms), Group II=Impaired relaxation pattern (E/A<1, DT>140 ms) and Group III=Pseudonormal/Restrictive pattern (E/A>1.5, S/D<1, with or without DT< or =140 ms). RESULT: Twenty two, thirty four, and three patients were assigned to Group I, II, III, respectively. The ROP could be measured with 'Front wave method' in 50 patients (84.7%), but with 'Baseline shift method' only in 19 patients (32.2%). ROP with 'Front wave method' was 65+/-25.7, 61+/-35.6, 71+/-35.2 cm/sec in Group I, II, III, respectively. There was no statistically significant difference in the value of ROP between group I and II (p>0.05). CONCLUSION: The ROP seems not to reflect the diastolic function in acute coronary syndrome, although it is measurable with the 'Front wave method' in most cases. The measurement of the ROP with 'Baseline shift method' is not feasible in the patients with acute coronary syndrome.
Acute Coronary Syndrome*
;
Angina, Unstable
;
Deceleration
;
Echocardiography*
;
Echocardiography, Doppler
;
Humans
;
Relaxation
2.Complications of 2-D Echocardiography Guided Transfemoral Right Ventricular Endomyocardial Biopsy.
Juyup HAN ; Yongwhi PARK ; Hyunsang LEE ; Hyunjae KANG ; Hyungseop KIM ; Dong Heon YANG ; Hun Sik PARK ; Yongkeun CHO ; Shung Chull CHAE ; Jae Eun JUN ; Wee Hyun PARK
Journal of Korean Medical Science 2006;21(6):989-994
Endomyocardial biopsy (EMBx) is a useful tool for diagnosing various cardiac pathologies. However, the routine use of EMBx has not gained widespread acceptance due to the possible complications related to the EMBx. Thus, not much information is available on the complications related to the EMBx. We prospectively evaluated 90 consecutive patients who underwent 2-D echocardiography guided transfemoral right ventricular EMBx at Kyungpook National University Hospital between March 2002 and November 2005 to determine the incidence, nature and subsequent management of complications related to EMBx. The clinical diagnoses before the EMBx were arrhythmogenic right ventricular dysplasia in 54, dilated cardiomyopathy in 19, Brugada syndrome in 9, myocarditis in 6 and miscellaneous in 2 patients. The overall major complication rate was 5.6% and no procedure-related mortality occurred. Myocardial perforation (n=3), which was the most frequent complication, did not progress to cardiac tamponade requiring pericardiocentesis in any patient. Hemodynamically unstable ventricular tachycardia occurred in 1 patient. New and persistent right bundle branch block occurred in another. Our findings suggest that 2-D echocardiography guided transfemoral right ventricular EMBx is a relatively safe procedure.
Wounds, Penetrating/*etiology/ultrasonography
;
Treatment Outcome
;
Surgery, Computer-Assisted/methods
;
Middle Aged
;
Male
;
Humans
;
Heart Ventricles/injuries/*pathology/*ultrasonography
;
Heart Injuries/*etiology/ultrasonography
;
Female
;
Endocardium/injuries/pathology
;
Echocardiography/methods
;
Biopsy, Needle/*adverse effects
;
Arrhythmia/*etiology/*ultrasonography
3.Complications of 2-D Echocardiography Guided Transfemoral Right Ventricular Endomyocardial Biopsy.
Juyup HAN ; Yongwhi PARK ; Hyunsang LEE ; Hyunjae KANG ; Hyungseop KIM ; Dong Heon YANG ; Hun Sik PARK ; Yongkeun CHO ; Shung Chull CHAE ; Jae Eun JUN ; Wee Hyun PARK
Journal of Korean Medical Science 2006;21(6):989-994
Endomyocardial biopsy (EMBx) is a useful tool for diagnosing various cardiac pathologies. However, the routine use of EMBx has not gained widespread acceptance due to the possible complications related to the EMBx. Thus, not much information is available on the complications related to the EMBx. We prospectively evaluated 90 consecutive patients who underwent 2-D echocardiography guided transfemoral right ventricular EMBx at Kyungpook National University Hospital between March 2002 and November 2005 to determine the incidence, nature and subsequent management of complications related to EMBx. The clinical diagnoses before the EMBx were arrhythmogenic right ventricular dysplasia in 54, dilated cardiomyopathy in 19, Brugada syndrome in 9, myocarditis in 6 and miscellaneous in 2 patients. The overall major complication rate was 5.6% and no procedure-related mortality occurred. Myocardial perforation (n=3), which was the most frequent complication, did not progress to cardiac tamponade requiring pericardiocentesis in any patient. Hemodynamically unstable ventricular tachycardia occurred in 1 patient. New and persistent right bundle branch block occurred in another. Our findings suggest that 2-D echocardiography guided transfemoral right ventricular EMBx is a relatively safe procedure.
Wounds, Penetrating/*etiology/ultrasonography
;
Treatment Outcome
;
Surgery, Computer-Assisted/methods
;
Middle Aged
;
Male
;
Humans
;
Heart Ventricles/injuries/*pathology/*ultrasonography
;
Heart Injuries/*etiology/ultrasonography
;
Female
;
Endocardium/injuries/pathology
;
Echocardiography/methods
;
Biopsy, Needle/*adverse effects
;
Arrhythmia/*etiology/*ultrasonography