1.Research on Optimization Plan for the Arrangement of Hospital Bed:Modeling and Empirical Analysis
Jun DAI ; Juntao LI ; Tao DU ; Yuqin CAI ; Dan FENG
Chinese Medical Equipment Journal 2003;0(11):-
Objective To find an efficient plan for the arrangement of the beds in hospital so that the beds-operating efficiency can be raised and the requirement of patients can be perfectly met. Methods According to the data analyzed via the method of mathematical statistics, optimizing model was built and automatic stimulation program was generated as well as conducted by matlab software. Results The characteristics of bed-occupation condition was acquired by data analysis, the result of optimizing model was stimulated by program and the most efficient plan emerges which was obviously better than the original FCFS (First Come First Serve) Plan. Conclusion The mathematical model built up is of great maneuverability in the practical situation to ameliorate the management efficiency of hospital beds considerably.
2.Detection of Human Chorionic Gonadotropin by Highly Sensitive Magnetic EnzymE-linked Chemiluminescent Immunoassay
Juntao LIU ; Ruping LIU ; Mixia WANG ; Chunxiu LIU ; Jinping LUO ; Xinxia CAI
Chinese Journal of Analytical Chemistry 2009;37(7):985-988
A highly sensitive magnetic enzymE-linked chemiluminescent immunoassay method was developed for the detection of human chorionic gonadotropin(HCG). The monoclonal antibody was covalently coupled on the surface of carboxylated magnetic beads to generate magnetic-biotargeting; Alkaline phosphatase(ALP) was utilized as a labeled reagent of another monoclonal antibody, whereas 3-(2-spimadamantane) 4-methoxy-4-(3-phosphoryloxy)phenyl-1,2-dioxetane(AMPPD) was utilized as the chemiluminescent substrate. Based on this concept, a highly sensitive chemiluminescent immunoassay method was established to test HCG. Then, several modifications were made to optimize the method, and the detection sensitivity and procedure were improved accordingly. The detection of the assay could be fulfilled within 60 min and the test result of HCG concentration was linear over the range of 0.15 150 IU/L with good relativity(r=0.960). The relative standard deviation(RSD) were below 5% and the sensitivity of this method was 0.15 IU/L. The proposed method with wide linear range, simple operation and fast detection showed good prospect in practical application on-site.
3.Comparison of the deep inferior epigastric perforator and pedicled transverse rectus abdominis myocutaneous flap
Liang LI ; Juntao LIU ; Haifeng CAI ; Wenlong ZHANG ; Pengju SHI ; Hongming ZHENG
Clinical Medicine of China 2015;31(10):895-898
Objective To compare the complication and cost-effectiveness of the deep inferior epigastric perforator(DIEP) flap and transverse rectus abdominis myocutaneous(TRAM) flap.Methods From January 2000 to December 2014,all patients who underwent DIEP flap and TRAM flap in the People's Hospital of Tangshan and the Affiliated Hospital of North China University of Science and Technology, were selected.Eleven patients underwent immediate breast reconstruction with TRAM flaps and 19 patients with DIEP flaps.The treatment cost,length of hospitalization, and complication in the two year after surgery for each group were compared.Results For the major complications,there were 5 cases appeared fat necrosis in TRAM group, and 1 case in DIEP group,the differences was statistically significant(P=0.016).One case appeared flap loss in TRAM group,and DIEP group was zero,both of the two group had no abdominal wall hernia, there was no significant difference (P > 0.05).For the minor complications, there were 4 cases appeared postoperative hematoma in TRAM group, and 1 case in DIEP group, the difference was statistically significant(P =0.047).Two cases appeared wound dehiscence in TRAM group,and DIEP group was 1 case, 1 case happened infection in TRAM group,there was no statistically significant difference(P>0.05).The treatment costs were (14 133.12±1 546.88)yuan for the TRAM group and (16 838.94± 3 006.05)yuan the DIEP group, the difference was statistically significant (P =0.010).The hospital stay was (17.28± 2.08)days for the pedicled TRAM group and (18.39±2.87) days for the DIEP group,the different was not statistically significant(P>0.05).Conclusion The DIEP flap has a better clinical outcomes,but more expensive.
4.Human Chorionicgonadotropin Measurement Method Based on Magnetic Nanoparticle Probes
Ruping LIU ; Juntao LIU ; Mixia WANG ; Jinping LUO ; Chunxiu LIU ; Xinxia CAI
Chinese Journal of Analytical Chemistry 2009;37(12):1749-1753
The magnetic nanoparticle probe was prepared by specifically connecting the streptavidin-conjugated magnetic nanoparticles and the antibody of analyte via the strong streptavidin-biotin interaction. Based on the magnetic nanoparticle probes, the concentration of human chorionicgonadotropin (HCG) was detected and a new CL method for of hormone was further established. The performances of the magnetic nanoparticle probes were characterized by UV-Vis spectrometry, transmission electron microscopy and dynamic light scattering. The experimental conditions that affected the chemiluminescence were optimized. The optimal concentrations of luminal and H_2O_2 were 2×10~(-4) mol/L and 8×10~(-4) mol/L, respectively, and optimal pH was 13. Under the optimized experiment conditions, a linear response of chemiluminescence intensity to HCG concentration was obtained with a correlation coefficients of 0.9924. The linear range was from 0.5 to 250 μg/L and wider than the conventional ELISA method (5-200 μg/L). The relative standard deviation was 3.8%. Correlation analysis showed that there was significant correlation between the method of magnetic nanoparticle probes and ELISA in 34 clinical samples. The proposed method with characters of sensitive, effective, fast response and wide detection range provided good application prospect in analysis of other ultra-micro protein.
5.An Analysis of Auditory Perception and Speech Ability Outcomes after Cochlear Implantation in Prelingually Deaf Children with Leukoencephalopathy
Zhibin ZHAO ; Hongyan JIANG ; Zheng FU ; Jie LIN ; Fei CAI ; Juntao LIANG ; Rong HAN
Journal of Audiology and Speech Pathology 2017;25(5):521-524
Objective To study the auditory perception and speech ability outcomes after cochlear implantation in prelingually deaf children with extremely severe neurosensory hearing loss and comorbid leukoencephalopathy.Methods Our study included 14 prelingually deaf children with leukoencephalopathy (confirmed by preoperative MRI scanning) who were treated with cochlear implantation in the Department of Otorhinolaryngology Head and Neck Surgery of Hainan Provincial People''s Hospital, including 8 males and 6 females of 1~6 yr with a mean age of 3.8 yr.Sixteen synchronous prelingually deaf children without central nervous system (CNS) diseases were also included as the control group, including 11 males and 5 females of 1~6 yr with a mean age of 4.4 yr.All the patients underwent pre-surgical assessments of audiology, radiology, speech ability and intelligence before cochlear implantation via transmastoid facial nerve recess approach was done, after which rehabilitation was provided at the Hainan Rehabilitation Center for Deaf Children.Categories of auditory performance (CAP) and speech intelligibility rate (SIR) were employed as the assessment criteria for the outcome of surgery, the scores of which at different timepoints after surgery were statistically compared through paired t-test between the two groups.Results All the patients gained post-surgical hearing and speech abilities to different degrees, whereas CAP and SIR scores both chronologically improved in the both groups.No statistical difference was revealed either in CAP or in SIR scores between the two groups at 6, 12 and 24 months after surgery (P>0.05).Conclusion Children with extremely severe neurosensory hearing loss can be reated with cochlear implantation even if they have comorbid leukoencephalopathy.The effects of auditory and speech rehabilitation for the same age patients with leukoencephalopathy are similar to those without leukoencephalopathy in 2 years after surgery.
6.Effects of reactive by burn rat serum oxygen species on apoptosis of pulmonary microvascular endothelial cells induced.
Weixia CAI ; Peng JI ; Lei FAN ; Juntao HAN ; Xiaolong HU ; Shuyue WANG ; Xiaobing FANG ; Xiongxiang ZHU ; Dahai HU
Chinese Journal of Burns 2014;30(4):320-324
OBJECTIVETo observe the level of intracellular reactive oxygen species (ROS) in rats with severe burn and pulmonary microvascular endothelial cells (PMVECs) treated with serum of rat with burn injury, and to investigate the relationship between ROS and apoptosis of PMVECs.
METHODS(1) Twenty-four SD rats were divided into sham injury group ( n = 3) and burn group (n = 21) according to the random number table (the same grouping method below). Rats in burn group were inflicted with 30% TBSA full-thickness scald on the back, and rats in sham injury group were sham injured. Blood samples were collected from abdominal aorta at post injury hour 6, 12, 24, 36, 48, 60, 72 respectively from 3 rats of burn group. The serum content of ROS was assayed by ELISA. The same determination was performed in rats of sham injury group. (2) Five rats were subjected to scald injury as above, and burn serum was prepared 24 hours after injury. Another 5 rats without receiving any treatment were used to prepare normal serum. (3) Marginal pulmonary tissue was harvested from 20 SD young rats. Cells were cultured with tissue block method and indentified with immunohistochemical staining. The third passage of PMVECs in logarithmic phase were inoculated in 6-well plates and 12-well plates. PMVECs in both plates were divided into 4 groups: normal serum group, burn serum group, normal serum + MnTBAP group, and burn serum + MnTBAP group, with 3 wells in each group. Cells in the former 2 groups were respectively cultured with special nutrient solution of endothelial cells without serum added with 15% healthy rat serum or 15% burn rat serum. Cells in the latter 2 groups were cultured with the same culture conditions as in the former two groups correspondingly with addition of 100 µmol/L MnTBAP in the nutrient solution. After being cultured for 24 h, the content of ROS in PMVECs in 6-well plates was detected with flow cytometry. The apoptosis of PMVECs in 12-well plates was observed with acridine orange-ethidium bromide staining, and the apoptosis rate was calculated. Data were processed with one-way analysis of variance and LSD-t test.
RESULTS(1) The serum contents of ROS in rats of burn group were respectively (187 ± 21), (235 ± 22), (231 ± 25), (291 ± 20), (315 ±23) nmol/mL at post injury hour 24, 36, 48, 60, 72, which were significantly higher than that in sham injury group [(141 ± 19) nmol/mL, with t values respectively 7. 86, 9. 57, 13. 87, 14.98, 18.40, P values below 0.01]. (2) Primary cells grew slowly and showed a cobblestone appearance. After passages, cells grew with orderly distribution. The positive rate of coagulation factor VIII of cells was (96 ± 5)% , and thus they were identified as PMVECs. (3) In normal serum group, burn serum group, normal serum + MnTBAP group, and burn serum + MnTBAP group, the contents of ROS in PMVECs were respectively 798 ± 40, 1 294 ± 84, 763 ± 59, 926 ± 42 ( F =93.01, P <0.01), and the apoptosis rates of PMVECs were respectively (6.2 ± 1.3)%, (57.3 ± 6. 7)%, (3.7 ± 0. 8)%, (28.7 ± 5. 7)% (F = 224.50, P <0.01) after being cultured for 24 h. Compared with those of normal serum group, the content of ROS and apoptosis rate of PMVECs in burn serum group increased significantly (with t values respectively 10.40 and 49.06, P values below 0.01). The content of ROS and apoptosis rate of PMVECs in burn serum + MnTBAP group were significantly lower than those in burn serum group (with t values respectively 7.48 and 23.94, P values below 0.01).
CONCLUSIONSSerum content of ROS was increased in severely burned rats. Burn rat serum stimulation on PMVECs can lead to the increase of the intracellular ROS and induce apoptosis. However application of MnTBAP can scavenge ROS and reduce the apoptosis induced by burn rat serum.
Animals ; Apoptosis ; Burns ; blood ; therapy ; Endothelial Cells ; pathology ; Enzyme-Linked Immunosorbent Assay ; Lung ; blood supply ; Oxygen ; Rats ; Reactive Oxygen Species ; blood ; Serum ; metabolism
7.Application of Micro-Electro-Mechanical-System Probe and Low-power & Low-noise Single Chip Integration System in Neural Loop Researching
Jianhui SUN ; Xinxia CAI ; Juntao LIU ; Chunxing WANG ; Dengwang LI ; Zeyuan CHEN ; Chuanfu CHENG ; Jinhui WANG ; Dongmei HU
Chinese Journal of Analytical Chemistry 2017;45(4):611-619
A 8-channel neural signal′s simultaneous transducer detection micro system was developed to research the neural loop located at the brain hippocampus zone. The components of the system contained the neural probe manufactured with the Micro-electro-mechanical-systems (MEMS) technique based on silicon-on-insulator (SOI) substrate, biological low noise chopper-stabilization amplifier, low noise and intermediate speed SAR-ADC converter, reduced and low power ASK/FSK modulation radio transmitter. The micro system was applicable with the characters of small volume, interferences free, neural electrophysiology and neurotransmitter simultaneous detection, high sensitivity, high linearity, etc. The electrode resistance was optimized to 35.0 kΩ after depositing nanometer platinum black on the 4 electrophysiological sites on the Pt electrode. With the modification enzyme technique, nanomaterial enzyme membrane (Pt-mPD-GluOx) was directly fixed on the glutamate detection locus for selectively detecting special neural neurotransmitter matter. In addition, the electrochemistry measurement results indicated that the linear range of glutamate was 6-35 μmol/L with correlation coefficient of 0.97, the sensitivity was 0.0069 pA/(μmol/L). The current response error was less than 3.0 pA, which showed that the neural needle satisfied differential selection. Also, the logic/analog mixed signal 180-nm Application specific integrated circuit (ASIC ) technique (SmicRF180 nm 1Poly6M) was used to manufacture the transducer back-end disposing IC chip, and the test results provided some key parameters such as chopper-stabilization amplifier (equivalent in putting noise voltage ≤0.7 μV rms@1 kHz, gain of 71-82 dB, CMRR/PSRR>100 dB), SAR-ADC (ENOB is 12 bits, power consumption is 1.2 mW when maxmium conversion speed is 1 Msps, signal-noise-ratio is 60.9 dB, etc), and ASK/FSK modulation radio transmitter (the PA′s outputting power of 4-5 dBm, the radiation range of 10 meters). The micro neural transducer integrated system was convenient and wireless wearable for the research of brain hippocampus region.
8.Short-term clinical outcome of carbon ion radiotherapy for cutaneous malignant melanoma
Hongyi CAI ; Xiaohu WANG ; Liying GAO ; Hong ZHANG ; Juntao RAN ; Qiuning ZHANG ; Qiang LI ; Zhiqiang LIU ; Lin ZHAO ; Guoqing XIAO ; Xiaowen ZHANG
Chinese Journal of Radiation Oncology 2010;19(3):250-252
Objective To evaluate the toxicity and efficacy of carbon ion radiotherapy for cutaneous malignant melanoma. Methods Form December 2006 to May 2009, 13 patients with superficial malignant melanoma were treated with carbon ion radiotherapy in the Institute of Modern Physics, Chinese Academy of Sciences. The total dose was 60 -66 GyE in 6 -12 fractions within 6 -12 days. The disease was Stage Ⅱ_a in 2, Ⅱ_b in 3, Ⅱ_c in 5, and Ⅲ_c in 3 patients. The toxicities were assessed according to the Radiation Therapy Oncology Group (RTOG) criteria, and the efficacy was evaluated with WHO criteria. Results The median follow-up time was 13.5 months (range, 1 -25 months) and the follow-up rate was 100%. Of the 13 patients, 10(77%) achieved complete remission (CR), and 3(23%) partial remission (PR). The overall response rate (RR) was 100%, and the median survival time was 21.3 months (95% CI, 18. 1 -24.5 months). The grade 0, 1,2 and 3 skin reaction occurred in 3, 6, 2 and 2 patients, respectively. The hematologic toxicities were mild. Conclusions Carbon ion radiotherapy is a safe and effective treatment for cutaneous malignant melanoma.
9.Second trimester maternal serum screening for Down's syndrome in women of advanced maternal age: a multi-center prospective study
Qingwei QI ; Yulin JIANG ; Juntao LIU ; Xuming BIAN ; Yan LI ; Shiming Lü ; Baosheng ZHU ; He WANG ; Zhengfeng XU ; Xiaoying PAN ; Yan CAI
Chinese Journal of Obstetrics and Gynecology 2008;43(10):737-741
Objeetive To evaluate the performance characteristics of the second trimester double test for the detection of fetal Down's syndrome(DS)in women of advanced maternal age(AMA).Methods We undertook a prospective nation-wide multi-centered study and chose alpha-fetoprotein(AFP))and free β-subunit of human chorionic gonadotrophin(free β-hCG)as the serum markers.Between May 2004 and September 2006,12 centers participated in the collection and analysis of maternal serum AFP and free β-hCG.Patients with an iuereaged risk of DS(≥1/270)wero offered generic sunniocentesis.Follow up of the outcome of all pregnancies was obtained.Patients were divided into two groups,the AMA group and the non-AMA group and the screening efficiency Was evaluated in beth groups.Results A total of 66 132 singleton pregnancies were included in the study.and there were 36 10(5.46%)AMA women.The median maternal age of AMA women was 36.8years(35-47 years).At a cut-off of 1/270,in the AMA group,the number of positive cases screened was 727 and 22 cases of fetal DS were detected:the number of negative cases screened was 2883,and no fetal DS was found.In the non-AMA group,the number of positive cases screened was 4743 and 69 cases of fetal DS were detected:the number of negative cases screened was 57 779,and 6 cases of fetal DS were diagnosed postnatally.In AMA group,the detection rate(DR),false positive rate(FPR)and odds of being affected given a positive result(OAPR)were 100%,19.7%and 3.0%respectively.In the non-AMA group,the DR,FPR and OAPR were 92.0%.7.5%and 1.5%respectively.Conclusion The double-marker test using AFP and free β-hCG is an effective screen strategy for second-trimester detection of Down syndrome in AMA women.
10.Conventional quality control and evaluation of Leksell Icon Gamma Knife cone-beam CT
Juntao CAI ; Yunbo XU ; Peng LI
Chinese Journal of Radiological Medicine and Protection 2023;43(1):63-67
Objective:To analyze the conventional quality control result of Leksell Icon Gamma Knife cone-beam CT and evaluate long-term stability of cone-bem CT.Methods:QA TOOL Plus was used to verify the accuracy of cone-beam CT. The phantom Catphan 503 was scanned, and the image spatial resolution, contrast to noise ratio and homogeneity were analyzed.Results:The maximum deviation in image volume of cone-beam CT was 0.09-0.17 mm, which passed the accuracy test. At the scanning patterns with CT dose index of 2.5 and 6.3 mGy, the spatial resolution was very stable at 7 and 8 lp/cm respectively. The contrast noise ratio and uniformity meet the reference requirements.Conclusions:The conventional quality control results of Leksell Icon Gamma Knife cone-beam CT are stable in 12 months. In addition to referring to the manufacturer′s baseline value, the unified analysis and evaluation standard for Gamma Knife need to be further improved for the quality control of cone-beam CT.