1.Tissue-engineered bone with vascular bundles or sensory nerve tracts for repairing large bone defects
Junjun QIN ; Dong YIN ; Guoxian PEI ; Shan JIANG ; Siyuan CHEN ; Le WANG ; Tianwang MU ; Mingdong LI
Chinese Journal of Tissue Engineering Research 2017;21(8):1161-1166
BACKGROUND: Neuropeptides, a kind of endogenous active substance in nerve tissues, can modulate physiological functions of multiple body systems.OBJECTIVE: To observe the effects of vascular bundles or sensory nerve tracts implanted into tissue-engineered bone for rabbit large bone defects on the expression levels of calcitonin gene-related peptide (CGRP) and neuropeptide-Y.METHODS: Fifty-four New Zealand rabbits were enrolled to make model of large bone defects, and then, the animal models were randomly divided into three groups, including sensory nerve tract, vascular bundle, and control groups (n=18 per group), followed by implanted with sensory nerve tracts, vascular bundle, and tissue-engineered bone without sensory tracts or vascular bundle, respectively. The defected bone received gross and Masson staining at 4, 8 and 12 weeks after modeling, to compare the expression levels of CGRP and neuropeptide-Y in each group.RESULTS AND CONCLUSION: mRNA expression levels of CGRP and neuropeptide-Y in the sensory nerve tract and vascular bundle groups were significantly higher than those in the control group at different time points after modeling (P < 0.05). mRNA expression levels of CGRP and neuropeptide-Y in the tissue-engineered bone began to be increased and peaked at the 8th week, and then decreased (P < 0.05), which were the lowest at the 4th week (P < 0.05).Immunohistochemical staining results showed that CGRP was mainly found in the bridge, periosteum of newly born bones and around blood vessels; while neuropeptide-Y mainly localized in the medullary cavity and around blood vessels. These results indicate that the implantation of vascular bundle and sensory nerve tracts for bone defects can upregulate the expression levels of CGRP and neuropeptide-Y, and promote bone repair. However, sensory tract implantation may cause sensory impairment; thereafter, vascular bundle implantation is more suitable for ideal tissue-engineered construction to meet physical requirements.
2.Up-regulated release of vascular endothelial growth factor in tissue engineered bone with implanted vascular bundles: a model of femoral defect in rabbits
Le WANG ; Junjun QIN ; Siyuan CHEN ; Tianwang MU ; Shan JIANG ; Peiran ZHAO ; Dan JIN ; Guoxian PEI
Chinese Journal of Orthopaedic Trauma 2009;11(6):540-545
Objective To investigate whether tissue engineered bone with implanted vascular bun-dles can up-regulate release of vascular endothelial growth factor (VEGF) in models of femoral defect in rabbits.Methods Thirty-two rabbits were randomized into 2 even groups.In both groups, a segmental bone defect of 15 mm in length was made at the left femur before a tissue engineered bone was inserted into the defect.In the experimental group, a femoral vascular bundle was implanted into the tissue engineered bone.In the control group, there was no vascular implantation.At 2, 4, 8, and 12 weeks after implantation, samples were taken to determine new bone formation by histology and expression level of VEGF by immuno-histochemistry.Results The new bone formation was significantly higher in the experimental group at the end of 4, 8, and 12 weeks(P < 0.05) .The expression level of VEGF in the experimental group was also significantly higher than in the control group at all time points after operation, and the expression of VEGF peaked at 4 weeks.Conclusion Tissue engineered bone with vascular bundle implanted can up-regulate VEGF release in models of femoral defect in rabbits.
3.Correlation between metabolic syndrome and early neurological deterioration in patients with minor stroke or high-risk transient ischemic attack
Zuowei DUAN ; Haiyan LIU ; Jiang XU ; Junjun SHAN ; Xiu'e WEI
International Journal of Cerebrovascular Diseases 2021;29(9):666-670
Objective:To investigate the correlation between metabolic syndrome (MetS) and early neurological deterioration (END) in patients with acute minor ischemic stroke (MIS) and high-risk transient ischemic attack (TIA).Methods:Consecutive patients with acute MIS or high-risk TIA admitted to the Second Affiliated Hospital of Xuzhou Medical University between May 2018 and June 2020 were enrolled prospectively. MIS was defined as the National Institutes of Health Stroke Scale (NIHSS) score ≤3, high-risk TIA was defined as ABCD 2 score ≥4, and END was defined as the highest score of NIHSS within 72 h after admission increased by ≥1 compared with the baseline. Multivariate logistic regression analysis was used to determine the correlation between MetS or its component and END. Results:A total of 145 patients with acute MIS or high-risk TIA were enrolled, including 66 males (45.5%), aged 68.28±9.71 years. Fifty-two patients (35.9%) met the diagnostic criteria of MetS, and 46 (31.7%) developed END. Univariate analysis showed that there were significant differences in age, sex, atrial fibrillation, elevated blood glucose, MetS, fasting blood glucose and C-reactive protein between the END group and the non-END group (all P<0.05). Multivariate logistic regression analysis showed that MetS (odds ratio 2.637, 95% confidence interval 1.127-6.169) and high blood glucose (odds ratio 2.672, 95% confidence interval 1.052-6.789) were the independent risk factors for END within 72 h of admission in patients with acute MIS or high-risk TIA. Conclusion:MetS is significantly associated with END in patients with acute MIS or high-risk TIA.
4.Oncologic outcomes of early stage cervical cancer performed operation by different laparoscopic surgical procedures: analysis of clinical data from mutiple centers
Kaijian LING ; Yanzhou WANG ; Hui ZHANG ; Xuyin ZHANG ; Junjun YANG ; Chengyan LUO ; Bin SONG ; Wenxi ZHANG ; Li DENG ; Gongli CHEN ; Yudi LI ; Qunying HU ; Yong CHEN ; Xin WANG ; Jun ZHANG ; Jingxin DING ; Tong REN ; Shan KANG ; Keqin HUA ; Yang XIANG ; Wenjun CHENG ; Zhiqing LIANG
Chinese Journal of Obstetrics and Gynecology 2020;55(9):617-623
Objective:To evaluate the oncologic outcomes of different laparoscopic radical hysterectomy.Methods:From January 2011 to December 2014, the laparoscopic operation cases of cervical cancer at stage Ⅰb1, Ⅰb2, Ⅱa1 and Ⅱa2, including the histologic subtypes of squamous-cell carcinoma, adenocarcinoma and adenosquamous carcinoma, were collected in five clinical centers. The data were divided into two groups according to the surgical procedures, that is, modified laparoscopic-vaginal radical hysterectomy (mLVRH) and total laparoscopic radical hysterectomy (TLRH). The overall survival rate (OS), disease-free survival rate (DFS) at 5 years were retrospectively analyzed in this study.Results:There were 674 cases in total, including 377 cases of mLVRH, 297 cases of TLRH. (1) The OS at 5 years: the mLVRH was 96.1% and the TLRH was 92.0%, and the mLVRH was higher than that of TLRH ( P=0.010). Stratify analysis, including stage of disease (Ⅰb1 and Ⅱa1), histologic subtypes (squamous-cell carcinoma, adenocarcinoma), lymph node metastasis, revealed that, ① Stage of disease: in stage Ⅰb1, the OS at five years of mLVRH was higher than that in TLRH group (98.6% vs 93.6%, P=0.012). In stage Ⅱa1, there was significant difference between the two groups, the OS at five years of mLVRH and TLRH were 93.6% and 77.6% ( P=0.007). ② Histologic subtypes: for the OS at five years of squamous-cell carcinoma, mLVRH and TLRH were 96.1% and 92.3%, and there was significant difference ( P=0.046); for adenocarcinoma, the OS at five years were 91.0% and 88.6%, and there was no difference between two groups ( P=0.230). ③ Lymph node metastasis: the mLVRH and TLRH with lymph node metastasis, the OS at five years were 98.6% and 96.4%; the mLVRH and TLRH without lymph node metastasis, the OS at five years were 89.3% and 80.8%. There were no significant differences between the two groups,respectively ( P=0.156, P=0.093). (2) The DFS at 5 years: there was no significant difference between mLVRH and TLRH (94.1% vs 90.9%, P=0.220). Stratify analysis for stage of disease, the mLVRH group was higher than that in the TLRH group in stage Ⅰb1 (97.0% vs 92.8%, P=0.039). However, for stage Ⅱa1, there was no significant difference between mLVRH and TLRH group (88.2% vs 75.8%, P=0.074). Conclusions:The results of this retrospective study indicated that different laparoscopy surgical procedures had diverse oncologic outcomes. The OS at 5 years of the mLVRH is superior to the TLRH. The DFS at 5 years in Ⅰb1 stage, the mLVRH is higher than the TLRH. Therefore, the modified laparoscopy is still an alternative surgery for early cervical cancer patients when following the principle of no-tumor-exposure.
5. Dorsal-and-medial hybrid approach versus medial-to-lateral approach in laparoscopic right hemicolectomy with complete mesocolic excision:A prospective comparative study
Zheng-hao CAI ; Hai-shan LIU ; Junjun MA ; Min-hua ZHENG
Chinese Journal of Practical Surgery 2019;39(12):1310-1315
OBJECTIVE: To compare dorsal-and-medial hybrid approach and medial-to-lateral approach in laparoscopic right hemicolectomy with complete mesocolic excision(CME). METHODS: Patients undergone laparoscopic right hemicolectomy in Department of Gastrointestinal Surgery in Ruijin Hospital Affiliated to Shanghai Jiaotong University School of Medicine from July 2017 to April 2018 were prospectively included.Patients were divided into two groups:dorsal group and medial group. Clinical and pathological data were collected and compared between the two groups. RESULTS: There were 35 patients in medial group and 40 patients in dorsal group. No significant differences were found between the two groups in baseline characteristics,perioperative outcomes and pathological results. No significant difference was found between the two groups in length of bowel(24 cm vs. 22 cm),A line distance(9.8 cm vs.9.4 cm),B line distance(9.0 cm vs. 8.5 cm),area of mesentery(112.4 cm~2 vs. 109.0 cm~2),total lymph node count(19 vs.19),lymph node adequate ratio(97.1% vs. 97.5%)and CME ratio(80% vs. 85%). Obesity was found to be an independent risk factor of CME ratio(P=0.019). CONCLUSION: Dorsal-and-medial hybrid approach and medial-to-lateral approach are comparable in safety,feasibility and effectiveness in laparoscopic right hemicolectomy with complete mesocolic excision. Randomized clinical trials with larger sample size are needed.
6.Dosimetric verification of stereotactic body radiotherapy treatment plan via ArcCHECK-3DVH system.
Shulin CHENG ; Dongyong SHAN ; Ke CAO ; Shizhen BIN ; Junjun ZHANG ; Tian TANG
Journal of Central South University(Medical Sciences) 2021;46(5):475-480
OBJECTIVES:
To study the feasibility of ArcCHECK-3DVH system in dosimetric verification for stereotactic body radiaotherapy (SBRT) with flattening filter free (FFF) model.
METHODS:
SBRT treatment plans for 57 patients were introduced into ArcCHECK phantom and recalculated. The calculated dose distribution of treatment planning system and the measured dose distribution of ArcCHECK phantom were compared by γ analysis. Then the 3 dimensional dose distribution of target and organs at risk was reconstructed by 3DVH software. The reconstructed dose and calculated dose with treatment planning system (TPS) were compared, and the dose volume γ pass rate and deviation of dose volume parameters to the target and organs at risk were quantitatively valuated.
RESULTS:
Based on the threshold criteria (3%, 3 mm, 10%), namely the deviation of measuring points between the planned value and the measured value was less than 3%, and the proportion of points with similar values in the plane or sphere with the center of the point and the radius of 3 mm was 10%, the relative and absolute dose pass rates of SBRT treatment plans in ArcCHECK system via γ analysis were greater than 95%. Based on the stricter threshold criteria (2%, 2 mm, 10%), the relative and absolute dose pass rates of SBRT treatment plan in ArcCHECK system via γ analysis were about 93%. In 3DVH dose verification, the γ pass rate of target and organs at risk was exceed 97%, and the deviations in 3DVH of the target and organs at risk were less than ±5%.
CONCLUSIONS
The ArcCHECK-3DVH system in dose verification can provide more comprehensive dose distribution information to reasonably evaluate the SBRT plan, with more significance for guiding clinical treatment.
Humans
;
Phantoms, Imaging
;
Quality Assurance, Health Care
;
Radiometry
;
Radiosurgery
;
Radiotherapy Dosage
;
Radiotherapy Planning, Computer-Assisted
;
Radiotherapy, Intensity-Modulated
7.Dosimetric verification of flattening filter free model based on TrueBeam accelerator using ArcCheck system.
Yuxing ZHU ; Dongyong SHAN ; Shizhen BIN ; Junjun ZHANG ; Ji ZHANG ; Xiaoming LIU ; Ke CAO ; Shulin CHENG
Journal of Central South University(Medical Sciences) 2018;43(8):864-868
To study the feasibility of ArcCheck verification system in dosimetric verification for stereotactic radiotherapy (SRT) the stereotactic radiotherapy (SRT) with flattening filter free (FFF) model.
Methods: A total of 76 cases under SRT treatment plans were introduced into ArcCheck phantom and recalculated. Threshold criteria was set as (3%, 3 mm, 10%) or (2%, 2 mm, 10%). The calculated dose distribution and the measured dose distribution of ArcCheck phantom were compared by means of distance to agree (DTA) and Gamma analysis method respectively.
Results: Based on the threshold criteria (3%, 3 mm, 10%), the relative and absolute mean pass rates of SRT treatment plans by DTA and Gamma analysis were greater than 95%. Based on the threshold criteria (2%, 2 mm, 10%), the relative and absolute mean pass rates of SRT treatment plan by DTA and Gamma analysis were about 90%. The dose pass rate of Gamma analysis method was slightly higher than that of DTA analysis method (P<0.001).
Conclusion: The ArcCheck verification system is a rapid and accurate method for SRT dose verification, and discrepancies are found in different analysis methods.
Feasibility Studies
;
Humans
;
Phantoms, Imaging
;
Radiosurgery
;
methods
;
Radiotherapy Dosage
;
Radiotherapy Planning, Computer-Assisted
;
Radiotherapy, Intensity-Modulated