1.Safety study of different intensity anticoagulation therapy of warfarin in octogenarian patients with nonvalvular atrial fibrillation
Jun WU ; Yan GUO ; Junhong WANG ; Di XU
Chinese Journal of Geriatrics 2011;30(7):540-543
Objective To investigate the safety of different intensity anticoagulation therapy of warfarin in preventing thromboembolism in octogenarian patients with nonvalvular atrial fibrillation (NVAF). Methods The 130 patients with persistent or permanent NVAF were randomly divided into three groups: low-intensity warfarin group (35 cases, international normalized ratio, INR (1.5-2.0), moderate-intensity warfarin group (32 cases, INR 2.1-2.5) and aspirin control group (63 cases). The rate of hemorrhagic events and the effect on renal function were observed. Results The incidence of hemorrhage was the lowest in low-intensity warfarin group compared to the other groups with slight bleeding in one case. life-threatening bleeding in one case, severe bleeding in one case and slight bleeding in four cases occurred in moderate-intensity warfarin group. Life-threatening bleeding in three cases, severe bleeding in two cases and slight bleeding in six cases occurred in aspirin control group. There were significant differences in bleeding incidence among the three groups (χ2=5.13,P<0.05). The low-intensity warfarin group and moderate-intensity warfarin group were superior to the aspirin control group in the effect on renal function (P<0.05). Conclusions It is safe that the dose of warfarin is maintained at low anticoagulation intensity between INR 1.5 and 2.0 in octogenarians with NVAF.
2.The analysis of clinical application of home-made immobilization device in SBRT
Hui LIU ; Jun ZHANG ; Yahua ZHONG ; Junhong ZHANG ; Gong ZHANG ; Di DENG ; Kang TAN
Chinese Journal of Radiation Oncology 2013;22(6):501-503
Objective To evaluate the effect of home-made immobilization device with KV-CBCT in lung-SBRT and investigate its clinical use value.Methods Choosing 10 lung tumor patients (half centre type tumor;half peripheral type) random analysis the interfractional and intrafractional setup errors in the SBRT process by this fixed device with KV-CBCT.The concrete method is using Varian's KV-CBCT scans the patients before and after the SBRT each time,then make the registration between the reconstructed 3 d image and the planned CT image (both based on bone landmark),we then obtain the average setup errors in LR,AP and SI directions.Simultaneously,this research make contrastive analysis of setup errors among this fixed device and other fixed devices such as vacuum pad,phantom in body IMRT.All data make one-factor analysis of variance by SSPS 17.0.Results All the setup errors data was gaussian distribution,the centre type interfraction was at (0.01 ±0.32) cm (LR),(-0.08 ±0.38) cm (AP),(0.14 ±0.36) cm (SI) of the cross section,peripheral type interfraction was at (0.01 ± 0.32) cm (LR),(-0.08 ± 0.38) cm (AP),(0.14 ± 0.36) cm (SI) of the cross section (P =0.001).We found out that the average of lung tumor's setup error at all three directions have no significant difference-the largest was the AP directions (P =0.003),the second was the SI direction (P =0.003) and the smallest was the LR direction (P =0.001).The central type has no significant difference at three directions.Compare to the other fixed device,the average setup errors of our device are (0.09 ± 0.33) cm (LR),(-0.10 ± 0.44) cm (SI),(0.17 ±0.35) cm (AP) better than the report at present paper.As the interfraction setup error was small enough by using this fixed device while it has beyond the system algorithm,the registration software of system shows (0.0 ± 0.0 cm).Conclusions The range of lung tumor motion can be cut down obviously and enhance each placement accuracy,repeatability,on SBRT with home-made immobilization device.
3.Construction and Application of Intelligent Management System of Operating Room Pharmacy Based on Failure Mode and Effect Analysis Method
Junhong DI ; Zhou GENG ; Qi QIU
Herald of Medicine 2024;43(1):41-46
Objective To establish an intelligent management system of operating room pharmacy,to promote the standardized management of drugs in the operating room,and to provide reference and experience for medical institutions.Methods Based on the failure mode and effect analysis(FMEA)method,the risk identification and assessment of the operating room pharmacy workflow were carried out of the Second Affiliated Hospital of Soozhou University.According to the risk priority index(RPN)value,the failure mode that needs to be improved was determined,the causes of failure were analyzed,intervention measures were formulated,and the improvement effect was evaluated.Results A total of 12 failure modes were found in the workflow of the operating room pharmacy.After the intelligent medicine cabinet and corresponding management system were used,the RPN value decreased by 337 in total,with a decrease rate of 67.8%.The level of narcotic drug management,the timeliness of patient medication,and the satisfaction of medical staff were significantly improved.Conclusions The FMEA method can effectively identify the risk links of the operating room pharmacy.The construction and application of the intelligent operating room pharmacy management system have significantly improved the drug management level of the operating room and the quality of medical services.