2.Comparison of the Clinical Manifestations and Prognosis of Henoch-Schonlein Purpura in Children with and without Abdominal Pain.
Sungwoo KIM ; Jungwon YOON ; Sujin JEONG
Korean Journal of Pediatric Gastroenterology and Nutrition 2011;14(4):359-367
PURPOSE: We compared the clinical manifestations and prognosis of Henoch-Schonlein Purpura (HSP) in children with and without abdominal pain to investigate the usefulness of endoscopy. METHODS: We retrospectively studied 185 HSP inpatients (group A [with abdominal pain] and group N [without abdominal pain]) who had been admitted to the BundangCHA hospital between 2001 and 2010. We compared clinical manifestations, laboratory findings and endoscopic and ultrasonographic findings. RESULTS: Of the 185 children, 112 (60.5%) had abdominal pain and 31 (16.8%) presented with abdominal pain before developing cutaneous purpura. Group A patients were older (6.9+/-3.5 vs. 5.3+/-3.3 years), had higher rates of positive results for stool occult blood (53.8%, p<0.001), and had longer hospital stays (5.2+/-4.2 vs. 3.6+/-2.5 days) than group N patients. Group A had a higher frequency of renal involvement than group N on admission (p=0.047). Ultrasonography showed small bowel wall thickening in 31 cases (43.7%) and increased Doppler flow in the bowel wall in 22 cases (31%) in Group A. Upper gastrointestinal endoscopy revealed HSP - related lesions in the stomach (25 cases) and duodenum (19 cases). The second portion of the duodenum was a more common lesion site than the duodenal bulb. Ultrasonography showed abnormalities in 13 of 19 patients with duodenal lesions. Recurrence was more common in Group A. CONCLUSION: These results suggest that recurrence and renal involvement are more common in HSP patients with abdominal pain. Upper gastrointestinal endoscopy could be a useful diagnostic tool for HSP patients who develop abdominal pain before cutaneous purpura.
Abdominal Pain
;
Child
;
Duodenum
;
Endoscopy
;
Endoscopy, Gastrointestinal
;
Humans
;
Inpatients
;
Length of Stay
;
Occult Blood
;
Prognosis
;
Purpura
;
Purpura, Schoenlein-Henoch
;
Recurrence
;
Retrospective Studies
;
Stomach
3.A Study on the Professional Self-concept, Self Efficacy and Job Satisfaction of Hemodialysis Unit Nurses.
Ji Hye LIM ; Shin Hwa LEE ; Jung Ah YOON ; Mi Young CHON
Korean Journal of Rehabilitation Nursing 2012;15(1):54-62
PURPOSE: The purpose of this study was to explore the level of professional self-concept, self-efficacy and job satisfaction among nurses who work at hemodialysis units. METHODS: With convenience sampling, 128 nurses working at hemodialysis settings in Chungcheong Province were participated in this study. Data were analyzed using SPSS/WIN 14.0 with descriptive statistics, t-test, ANOVA, and Pearson correlation coefficient. RESULTS: The mean scores were 2.68 for professional self-concept, 3.65 for self efficacy and 3.14 for job satisfaction. There were significant differences in professional self-concept according to age, religion, position and clinical experience. There was statistically significant difference in self-efficacy according to age. Also, there was statistically significant difference in job satisfaction according to age, marital status, hospital type, position, clinical experience, and the number of patients per nurse. Job satisfaction was positively correlated with professional self-concept and self-efficacy. CONCLUSION: These findings provided that interventions to enhance professional self-concept as well as the strategies to improve self-efficacy are very important.
Humans
;
Job Satisfaction
;
Marital Status
;
Renal Dialysis
;
Self Efficacy
4.Next-generation sequencing enables the discovery of more diverse positive clones from a phage-displayed antibody library.
Wonjun YANG ; Aerin YOON ; Sanghoon LEE ; Soohyun KIM ; Jungwon HAN ; Junho CHUNG
Experimental & Molecular Medicine 2017;49(3):e308-
Phage display technology provides a powerful tool to screen a library for a binding molecule via an enrichment process. It has been adopted as a critical technology in the development of therapeutic antibodies. However, a major drawback of phage display technology is that because the degree of the enrichment cannot be controlled during the bio-panning process, it frequently results in a limited number of clones. In this study, we applied next-generation sequencing (NGS) to screen clones from a library and determine whether a greater number of clones can be identified using NGS than using conventional methods. Three chicken immune single-chain variable fragment (scFv) libraries were subjected to bio-panning on prostate-specific antigen (PSA). Phagemid DNA prepared from the original libraries as well as from the Escherichia coli pool after each round of bio-panning was analyzed using NGS, and the heavy chain complementarity-determining region 3 (HCDR3) sequences of the scFv clones were determined. Subsequently, through two-step linker PCR and cloning, the entire scFv gene was retrieved and analyzed for its reactivity to PSA in a phage enzyme immunoassay. After four rounds of bio-panning, the conventional colony screening method was performed for comparison. The scFv clones retrieved from NGS analysis included all clones identified by the conventional colony screening method as well as many additional clones. The enrichment of the HCDR3 sequence throughout the bio-panning process was a positive predictive factor for the selection of PSA-reactive scFv clones.
Antibodies
;
Bacteriophages
;
Chickens
;
Clone Cells*
;
Cloning, Organism
;
Complementarity Determining Regions
;
DNA
;
Escherichia coli
;
Immunoenzyme Techniques
;
Mass Screening
;
Methods
;
Polymerase Chain Reaction
;
Prostate-Specific Antigen
;
Single-Chain Antibodies
5.Detrimental effects of lipopolysaccharide on the attachment and outgrowth of various trophoblastic spheroids on human endometrial epithelial cells
Wontae KIM ; Jungwon CHOI ; Hyejin YOON ; Jaewang LEE ; Jin Hyun JUN
Clinical and Experimental Reproductive Medicine 2021;48(2):132-141
Objective:
Lipopolysaccharide (LPS) from Gram-negative bacteria causes poor uterine receptivity by inducing excessive inflammation at the maternal-fetal interface. This study aimed to investigate the detrimental effects of LPS on the attachment and outgrowth of various types of trophoblastic spheroids on endometrial epithelial cells (ECC-1 cells) in an in vitro model of implantation.
Methods:
Three types of spheroids with JAr, JEG-3, and JAr mixed JEG-3 (JmJ) cells were used to evaluate the effect of LPS on early implantation events. ECC-1 cells were treated with LPS to mimic endometrial infection, and the expression of inflammatory cytokines and adhesion molecules was analyzed by quantitative real-time polymerase chain reaction and western blotting. The attachment rates and outgrowth areas were evaluated in the various trophoblastic spheroids and ECC-1 cells treated with LPS.
Results:
LPS treatment significantly increased the mRNA expression of inflammatory cytokines (CXCL1, IL-8, and IL-33) and decreased the protein expression of adhesion molecules (ITGβ3 and ITGβ5) in ECC-1 cells. The attachment rates of JAr and JmJ spheroids on ECC-1 cells significantly decreased after treating the ECC-1 cells with 1 and 10 μg/mL LPS. In the outgrowth assay, JAr spheroids did not show any outgrowth areas. However, the outgrowth areas of JEG-3 spheroids were similar regardless of LPS treatment. LPS treatment of JmJ spheroids significantly decreased the outgrowth area after 72 hours of coincubation.
Conclusion
An in vitro implantation model using novel JmJ spheroids was established, and the inhibitory effects of LPS on ECC-1 endometrial epithelial cells were confirmed in the early implantation process.
6.Detrimental effects of lipopolysaccharide on the attachment and outgrowth of various trophoblastic spheroids on human endometrial epithelial cells
Wontae KIM ; Jungwon CHOI ; Hyejin YOON ; Jaewang LEE ; Jin Hyun JUN
Clinical and Experimental Reproductive Medicine 2021;48(2):132-141
Objective:
Lipopolysaccharide (LPS) from Gram-negative bacteria causes poor uterine receptivity by inducing excessive inflammation at the maternal-fetal interface. This study aimed to investigate the detrimental effects of LPS on the attachment and outgrowth of various types of trophoblastic spheroids on endometrial epithelial cells (ECC-1 cells) in an in vitro model of implantation.
Methods:
Three types of spheroids with JAr, JEG-3, and JAr mixed JEG-3 (JmJ) cells were used to evaluate the effect of LPS on early implantation events. ECC-1 cells were treated with LPS to mimic endometrial infection, and the expression of inflammatory cytokines and adhesion molecules was analyzed by quantitative real-time polymerase chain reaction and western blotting. The attachment rates and outgrowth areas were evaluated in the various trophoblastic spheroids and ECC-1 cells treated with LPS.
Results:
LPS treatment significantly increased the mRNA expression of inflammatory cytokines (CXCL1, IL-8, and IL-33) and decreased the protein expression of adhesion molecules (ITGβ3 and ITGβ5) in ECC-1 cells. The attachment rates of JAr and JmJ spheroids on ECC-1 cells significantly decreased after treating the ECC-1 cells with 1 and 10 μg/mL LPS. In the outgrowth assay, JAr spheroids did not show any outgrowth areas. However, the outgrowth areas of JEG-3 spheroids were similar regardless of LPS treatment. LPS treatment of JmJ spheroids significantly decreased the outgrowth area after 72 hours of coincubation.
Conclusion
An in vitro implantation model using novel JmJ spheroids was established, and the inhibitory effects of LPS on ECC-1 endometrial epithelial cells were confirmed in the early implantation process.
7.Clinical usefulness of procalcitonin/albumin and blood urea nitrogen/albumin ratios for the early detection of bacteremia
Sang Shin PYO ; Dae Wui YOON ; Hyunjung KIM ; Hiun Suk CHAE ; Hae Kyung LEE
Annals of Clinical Microbiology 2023;26(4):103-115
Background:
Early prediction of bacteremia is important because sepsis may develop if bacteremia is not treated in time. We aimed to determine whether blood tests are clinically useful in predicting gram-negative versus gram-positive bacteremia.
Methods:
We retrospectively analyzed the medical records of 16,569 patients who underwent blood culture testing among those who visited St. Mary’s Hospital of Uijeongbu, Catholic University from January 1, 2018 to December 31, 2018. After excluding 15,580 patients with insufficient data for analysis, the total study population was 989.
Results:
In the multivariable logistic regression analysis for gram-negative bacteremia, after adjusting for major variables, procalcitonin (odds ratio [OR] 1.02, P < 0.001), high-sensitivity C-reactive protein (OR 1.03, P = 0.010), and albumin (OR 0.55, P = 0.010) were significant. In the same model, lactic acid (OR 1.08, P = 0.010), blood urea nitrogen (BUN) (OR 1.02, P = 0.010), and albumin (OR 0.50, P = 0.005) were significant for gram-positive bacteremia.We constructed blood indicators by combining blood tests that were significant in multivariable logistic regression analysis. Comparing the area under the curve (AUC) of the receiver operating characteristic curve, the AUC of the procalcitonin/albumin ratio in gramnegative bacteremia was significantly higher than that of procalcitonin (0.846 vs. 0.837, P = 0.005), and the AUC of the BUN/albumin ratio in gram-positive bacteremia was significantly higher than that of BUN (0.709 vs. 0.679, P = 0.007).
Conclusion
The procalcitonin/albumin ratio is expected to be helpful in the early prediction of gram-negative bacteremia, whereas the BUN/albumin ratio in the early prediction of grampositive bacteremia.
8.Dosimetric Influence of Implanted Gold Markers in Proton Therapy for Prostate Cancer.
Jungwon KWAK ; Jungwook SHIN ; Jin Sung KIM ; Sung Yong PARK ; Dongho SHIN ; Myonggeun YOON ; Soah PARK ; Dongwook KIM ; Young Gyeung LIM ; Se Byeong LEE
Korean Journal of Medical Physics 2010;21(3):291-297
This study examined the dosimetric influence of implanted gold markers in proton therapy and the effects of their positions in the spread-out Bragg peak (SOBP) proton beam. The implanted cylindrical gold markers were 3 mm long and 1.2 mm in diameter. The dosimetric influence of the gold markers was determined with markers at various locations in a proton-beam field. Spatial dose distributions were measured using a three-dimensional moving water phantom and a stereotactic diode detector with an effective diameter of 0.5 mm. Also, a film dosimetry was performed using Gafchromic External Beam Treatment (EBT) film. The GEANT4 simulation toolkit was used for Monte-Carlo simulations to confirm the measurements and to construct the dose-volume histogram with implanting markers. Motion data were obtained from the portal images of 10 patients to investigate the effect of organ motions on the dosimetric influence of markers in the presence of a rectal balloon. The underdosed volume due to a single gold marker, in which the dose was less than 95% of a prescribed amount, was 0.15 cc. The underdosed volume due to the presence of a gold marker is much smaller than the target volume. However, the underdosed volume is inside the gross tumor volume and is not smeared out due to translational prostate motions. The positions of gold markers and the conditions of the proton-beam field give different impacts on the dose distribution of a target with implanted gold markers, and should be considered in all clinical proton-based therapies.
Film Dosimetry
;
Humans
;
Prostate
;
Prostatic Neoplasms
;
Proton Therapy
;
Protons
;
Tumor Burden
;
Water
9.Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases.
Dongwook KIM ; Myonggeun YOON ; Sung Yong PARK ; Se Byeong LEE ; Dong Ho SHIN ; Doohyeon LEE ; Jungwon KWAK ; Soah PARK ; Young Kyung LIM ; Jinsung KIM ; Jungwook SHIN ; Kwan Ho CHO
Korean Journal of Medical Physics 2008;19(2):89-94
TomoTherapy has a merit to treat cancer with Intensity modulated radiation and combines precise 3-D imaging from computerized tomography (CT scanning) with highly targeted radiation beams and rotating beamlets. In this paper, we comparing the dose distribution between TomoTherapy and linear accelerator based intensity modulated radiotherapy (IMRT) for 10 Head & Neck patients using TomoTherapy which is newly installed and operated at National Cancer Center since Sept. 2006. Furthermore, we estimate how the homogeneity and Normal Tissue Complication Probability (NTCP) are changed by motion of target. Inverse planning was carried out using CadPlan planning system (CadPlan R.6.4.7, Varian Medical System Inc. 3100 Hansen Way, Palo Alto, CA 94304-1129, USA). For each patient, an inverse IMRT plan was also made using TomoTherapy Hi-Art System (Hi-Art2_2_4 2.2.4.15, TomoTherapy Incorporated, 1240 Deming Way, Madson, WI 53717-1954, USA) and using the same targets and optimization goals. All TomoTherapy plans compared favorably with the IMRT plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Our results suggest that TomoTherapy is able to reduce the normal tissue complication probability (NTCP) further, keeping a similar target dose homogeneity.
Head
;
Humans
;
Imaging, Three-Dimensional
;
Neck
;
Organs at Risk
;
Particle Accelerators
;
Radiotherapy, Intensity-Modulated
10.Image Based Quality Assurance of Range Compensator for Proton Beam Therapy.
Jin Sung KIM ; Myonggeun YOON ; Dongwook KIM ; Young Kyung LIM ; Jungwon KWAK ; Soah PARK ; Dong Ho SHIN ; Jungwook SHIN ; Se Byeong LEE ; Sung Yong PARK ; Kwan Ho CHO
Korean Journal of Medical Physics 2008;19(1):35-41
The main benefit of proton therapy over photon beam radiotherapy is the absence of exit dose, which offers the opportunity for highly conformal dose distributions to target volume while simultaneously irradiating less normal tissue. For proton beam therapy two patient specific beam modifying devices are used. The aperture is used to shape the transverse extension of the proton beam to the shape of the tumor target and a patient-specific compensator attached to the block aperture when required and used to modify the beam range as required by the treatment plan for the patient. A block of range shifting material, shaped on one face in such a way that the distal end of the proton field in the patient takes the shape of the distal end of the target volume. The mechanical quality assurance of range compensator is an essential procedure to confirm the 3 dimensional patient-specific dose distributions. We proposed a new quality assurance method for range compensator based on image processing using X-ray tube of proton therapy treatment room. The depth information, boundaries of each depth of plan compensatorfile and x-ray image of compensator were analyzed and presented over 80% matching results with proposed QA program.
Humans
;
Proton Therapy
;
Protons