1.The comparative study of thermal inductive effect between internal connection and external connection implant in abutment preparation.
The Journal of Korean Academy of Prosthodontics 2007;45(1):60-70
STATEMENT OF PROBLEM: The cement-type abutment would be needed for the reduction of its body in order to correct the axis and to assure occlusal clearance. In the case of intraoral preparation, there is a potential risk that generated heat could be transmitted into the bone-implant interface, where it can cause deterioration of tissues around the implant and failed osseointegration. PURPOSE: The purpose of this study was to assess the difference of the heat transmitting effect on external and internal connection implant types under various conditions. MATERIAL AND METHOD: For evaluating the effects of alternating temperature, the thermocoupling wires were attached on 3 areas of the implant fixture surface corresponding to the cervical, middle, and apex. The abutments were removed 1mm in depth horizontally with diamond burs and were polished for 30 seconds at low speed with silicone points using pressure as applied in routine clinical practice. Obtained data were analyzed using Mann-Whitney rank-sum test and Wilcoxon / Kruskal-Wallis Tests. PESULT: Increased temperature on bone-implant interface was evident without air-water spray coolant both at high speed reduction and low speed polishing (p<.05). But, the difference between connection types was not shown. CONCLUSION: The reduction procedure of abutment without using proper coolant leads to serious damage of oral tissues around the implant irrespective of external and internal connection type.
Axis, Cervical Vertebra
;
Dental Instruments
;
Hot Temperature
;
Osseointegration
;
Silicones
2.Detachable zirconia prosthesis using Milled bar and ADDTOC attachment in partial edentulous mandible: A case report
The Journal of Korean Academy of Prosthodontics 2023;61(1):90-99
Implant overdentures are widely used as a treatment method to restore oral function in completely edentulous or partially edentulous patients with severe bone resorption. Using a milled bar, it is mechanically advantageous as the implant fixtures are splinted. Applying additional attachments to the bar has the advantage of dispersing the stress applied to the implant. In this case, a patient who used implant overdentures using 4 implants wanted to fabricate a new prosthesis due to repeated fractures of the denture and weakened retention. Milled bar with ADDTOC attachment and zirconia prosthesis were fabricated by CAD-CAM method and mechanically and aesthetically satisfactory results were obtained.
3.Retrievable SCP (screw-cement prosthesis) implant-supported fixed partial dentures in a fully edentulous patient: a case report.
Joo Hyeun KIM ; Bo Hyeok YUN ; Jung Eun JANG ; Jung Bo HUH ; Chang Mo JEONG
The Journal of Korean Academy of Prosthodontics 2012;50(4):318-323
Implant prostheses were classified into screw-retained prosthesis and cement-retained prosthesis by their method of retaining, and there is screw and cement retained implant prosthesis (SCRP) which has been made reflecting the strengths of these two. The advantages of the SCRP technique are easy retrievability and passive fit of implant prostheses. However, the occlusal screw holes of implant prostheses can be thought as a disadvantage with respect to esthetics and occlusion. Inappropriately positioned implants also limited the use of the SCRP technique. The present study is reporting about the case where nine implants (US II, OSSTEM, Seoul, Korea) were placed in maxilla and eight in mandible respectively in fully edentulous patients. Then, the cement-retained prosthesis was applied for the part in which the screw hole positioned improperly, and screw-retained prosthesis for properly positioned implants so that the combined screw-cement prosthesis has been produced where the satisfying result has shown in both function and esthetics. Three-year follow-up has been done for the patient.
Denture, Partial, Fixed
;
Esthetics
;
Follow-Up Studies
;
Humans
;
Mandible
;
Maxilla
;
Prostheses and Implants
4.Prenatal Diagnosis of Fetal Seizure: A Case Report.
Eui JUNG ; Bo Yon LEE ; Chu Yeop HUH
Journal of Korean Medical Science 2008;23(5):906-908
A 35-yr-old woman carrying a 17-week-old fetus presented with right hydronephrosis and a single umbilical artery. Karyotyping was normal and targeted ultrasonography showed an otherwise normal fetus. After 28 weeks of gestation, the mother felt rapid, repetitive fetal movement and an ultrasound at 30 weeks of gestation revealed tonic clonic movements of the fetal trunk and extremities. At 36 weeks of gestation, an emergency repeat Cesarean section was performed because of a premature rupture of the membranes and a male infant weighing 4,295 gm was delivered. After birth, the infant continued to have movements suggestive of a generalized tonic clonic seizure. Brain computed tomography and magnetic resonance imaging revealed normal structures and an electroencephalography showed generalized suppression. Treatment with phenobarbital resulted in substantial improvement in the number of seizure episodes, however fine seizure-like movement continued in both of the hands, feet and in the tongue until the five-month follow-up. This is the first Korean report of a fetal seizure being diagnosed during the prenatal period.
Female
;
Fetal Diseases/*diagnosis/ultrasonography
;
Humans
;
Infant, Newborn
;
Karyotyping
;
Magnetic Resonance Imaging/methods
;
Male
;
Phenobarbital/pharmacology
;
Pregnancy
;
Prenatal Diagnosis/*methods
;
Seizures/*diagnosis
;
Tomography, X-Ray Computed/methods
;
Ultrasonography, Prenatal/*methods
5.A case of lipoleiomyoma in uterus.
Hyun Tai SHIN ; Hee Suk JUNG ; Jin Kee HONG ; Chu Yeop HUH ; Seung Bo KIM ; Jae Hyun LEE
Korean Journal of Obstetrics and Gynecology 1993;36(5):711-714
No abstract available.
Uterus*
6.Delayed Rupture of the Extensor Pollicis Longus Tendon Following Intramedullary Nailing of Radial Shaft Fracture.
Jin Yeong PARK ; Soon Ho HUH ; Bo Hyun JUNG
The Journal of the Korean Orthopaedic Association 2017;52(4):364-369
Delayed rupture of the extensor pollicis longus tendon mostly occur after plate fixation of distal radius fracture. However, delayed rupture of the extensor pollcis longus tendon following intramedullary nailing of radial shaft fracture is very rare. We report one case of delayed rupture of the extensor pollicis longus tendon following intramedullary nailing, presenting abnormal signs from adhesion of the extensor pollicis longus with extensor indicis at the nail insertion site.
Fracture Fixation, Intramedullary*
;
Radius Fractures
;
Rupture*
;
Tendon Injuries
;
Tendon Transfer
;
Tendons*
7.Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment
Jae-Won CHOI ; Sung-Ki CHAE ; Jung-Bo HUH
The Journal of Korean Academy of Prosthodontics 2021;59(2):173-180
Purpose:
The purpose of this study was to evaluate the retentive characteristics of the additional attachments used with implant bar attachment under repeated insertion/removal cycles.
Materials and methods:
The newly developed attachment and the commercially available attachment were investigated: ADD-Lock (AL), Locator blue (LB). Two fixtures were placed parallel to each other on the custom lower mounting, and patrix of each attachment was fixed to the fixture. Also, the matrix of each attachment was placed on the opposing upper mounting. A universal testing machine was used to measure the retentive force during initial, 100, 250, 500, 1000, 2000, and 2500 repeated insertion/removal cycles. Wear and deformation of the attachment s were observed by scanning electron microscopy (SEM).Mann-Whitney U test (α=.05) and wilcoxon signed-rank test (α=.05) were performed to compare retentive force between each group and before and after 2500 repeated insertion/removal cycles.
Results:
In terms of initial retentive force and retentive force after 2500 repeated insertion/removal cycles, the AL group (15.24 ± 1.46 N and 9.74 ± 1.16 N) showed significantly smaller values than the LB group (43.53 ± 12.39 N and 22.99 ± 4.77 N) (P <.05). Also, in the loss of retentive force, the AL group (5.50 ± 1.08 N, 36.08%) showed a smaller value than the LB group (20.54 ± 11.89 N, 47.19%) (P <.05). Based on SEM analysis, The AL group showed noticeable wear and deformation in the patrix and the LB group in the matrix.
Conclusion
Locator showed a higher initial retentive force than newly developed attachment, while the loss of retentive force was also higher. Both additional attachments are considered to have sufficient retentive force after repeated insertion/removal cycles.
8.Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment
Jae-Won CHOI ; Sung-Ki CHAE ; Jung-Bo HUH
The Journal of Korean Academy of Prosthodontics 2021;59(2):173-180
Purpose:
The purpose of this study was to evaluate the retentive characteristics of the additional attachments used with implant bar attachment under repeated insertion/removal cycles.
Materials and methods:
The newly developed attachment and the commercially available attachment were investigated: ADD-Lock (AL), Locator blue (LB). Two fixtures were placed parallel to each other on the custom lower mounting, and patrix of each attachment was fixed to the fixture. Also, the matrix of each attachment was placed on the opposing upper mounting. A universal testing machine was used to measure the retentive force during initial, 100, 250, 500, 1000, 2000, and 2500 repeated insertion/removal cycles. Wear and deformation of the attachment s were observed by scanning electron microscopy (SEM).Mann-Whitney U test (α=.05) and wilcoxon signed-rank test (α=.05) were performed to compare retentive force between each group and before and after 2500 repeated insertion/removal cycles.
Results:
In terms of initial retentive force and retentive force after 2500 repeated insertion/removal cycles, the AL group (15.24 ± 1.46 N and 9.74 ± 1.16 N) showed significantly smaller values than the LB group (43.53 ± 12.39 N and 22.99 ± 4.77 N) (P <.05). Also, in the loss of retentive force, the AL group (5.50 ± 1.08 N, 36.08%) showed a smaller value than the LB group (20.54 ± 11.89 N, 47.19%) (P <.05). Based on SEM analysis, The AL group showed noticeable wear and deformation in the patrix and the LB group in the matrix.
Conclusion
Locator showed a higher initial retentive force than newly developed attachment, while the loss of retentive force was also higher. Both additional attachments are considered to have sufficient retentive force after repeated insertion/removal cycles.
9.Implant-assisted overdenture using milled bar and ADDTOC in edentulous maxilla: A case report
Yong-Bum JO ; Chang-Mo JEONG ; Jung-Bo HUH ; Mi-Jung YUN ; So-Hyoun LEE ; Min-Jung KIM
The Journal of Korean Academy of Prosthodontics 2022;60(2):160-167
One of the treatment options for edentulous state patients with residual ridge resorption is implant overdenture using milled bar and attachment. It not only provides improved retention and stability but can also reduce the coverage of palatal surface. In addition, when a small number of implants are used, milled bar has the effect of being splinted between implant fixtures, which makes it mechanically advantageous under functions such as mastication. The patient in this case was a maxillary edentulous state patient with a considerable amount of residual alveolar bone resorption after removing the existing failed implants. Three implants were planted on both sides and an implant overdenture was fabricated using milled bar and ADD-TOC attachment.
10.Implant overdenture using milled bar and attachment in partially edentulous mandible: a case report
Min-Jung KIM ; Jung-Bo HUH ; Chang-Mo JEONG ; Mi-Jung YUN ; So-Hyoun LEE ; Yong-Bum JO
The Journal of Korean Academy of Prosthodontics 2022;60(1):71-79
Excessive crown height space increases can cause crestal bone loss and screw loosening after prosthesis is placed. Milled bar and implant overdenture can be used as a treatment method for partially edentulous patients who have severe alveolar bone loss and excessive crown height space. Milled bar can provide primary splinting effect and stability between implants. Also, milled bar with additional retention device such as Advanced Dental Device-Treatment Of Choice (ADD-TOC) and magnet can provide additional retention force for implant overdenture. In this case, the patient has a partially edentulous mandible that has severe alveolar bone loss and multiple number of teeth loss after excision due to leiomyosarcoma. Because of the long-term loss of mandibular molars, the opposing teeth were extruded. Maxillary left molars were corrected to the occlusal plane through molar intrusion, and mandibular left molar region were treated with implant overdenture, using milled bar with ADD-TOC and magnet after implant placement. The clinical result was satisfactory on the aspect of esthetic and masticatory function.