1.The fracture characteristics of glass fiber post and core on using different types of core resin materials.
Dong Wook SHIM ; June Sung SHIM ; Seok Hyung LEE ; Keun Woo LEE
The Journal of Korean Academy of Prosthodontics 2004;42(3):280-293
STATEMENT OF PROBLEM: Glass fiber post is one of recent developments to accommodate esthetic restoration for endodontically treated teeth. This has many advantages over conventional post system in physical properties, esthetic factor, risk of root and restoration fracture, adhesion to core, radiopacity, removal and retrievabilty, biocompatibility and chemical stability. PURPOSE: This in vitro study was to evaluate the most suitable type of resin core for the glass fiber post through surveying the fracture modes and the maximum load that fractures the tooth. MATERIAL AND METHODS: 50 sound maxillary premolars restored with glass fiber posts(ParaPost(R) Fiber White) and different types of resin cores(ParaCore, Z100(TM), Rebilda(R) and Admira(R)) were prepared and loaded to faiure in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with resin and those of metal cast and core. With the data, Wilcoxon rank sum test was used to validate the significance between the test groups, and Tukey's studentized range test was used to check if there is any significant statistical difference between each test group. Every analysis was approved with 95% reliance. RESULTS: On measuring the maximum fracture load of teeth specimens, there was a significant difference between the maximum fracture loads of the tooth specimens. ParaCore showed the highest mean maximum fracture load followed by Z100(TM). And, the distribution of fracture mode of tooth specimens showed generally Type D, the three parted fracture of the core around the post was mostly seen(62.5%), and specifically, ParaCore showed 90% and Z100(TM) showed 100% Type D fracture. CONCLUSION. Referring to the values of maximum fracture load and mean compressive fracture load, ParaCore and Z100(TM) had high values and are recommended as tooth colored resin core material for glass fiber post. CLINICAL IMPLICATIONS: This study was carried out intending to be of aid in selecting the appropriate resin core for the glass fiber post. The dual cure type composite resin ParaCore and light cure type composite resin Z100(TM) have good properties and are recommended as tooth colored resin core material for glass fiber post.
Bicuspid
;
Glass*
;
Humans
;
Risk Factors
;
Tooth
2.The level of buccal gingival margin around single and two adjacent implant restorations: a preliminary result.
Young Bum KIM ; June Sung SHIM ; Chong Hyun HAN ; Sun Jai KIM
The Journal of Advanced Prosthodontics 2009;1(3):140-144
STATEMENT OF PROBLEM: Little information is available about the buccal gingival level of multiple implant restorations. PURPOSE: This study was aimed to evaluate the relationship between width and height of buccal soft tissue around single and 2 adjacent implant restorations. MATERIAL AND METHODS: Four implant restoration groups (first and second molars, single second molars, posterior single restorations between teeth, and anterior single restorations between teeth) were randomly chosen from one dental institute. Each group comprised of 6 patients. After 6 months of function, silicone impressions were taken and stone models were fabricated for each restoration group. The stone models were cut in bucco-lingual direction at the most apical point of buccal gingival margin. The height and width of buccal supra-implant soft tissue were measured. One way ANOVA and Tukey HSD post hoc tests were performed to analyze the data obtained (P < .05). RESULTS: The most unfavorable width-height ratio was noted for the group, which was comprised of the second molar in the multiple adjacent (first and second molar) implant-supported restorations. The group also resulted in the shorter height of buccal supra-implant mucosa rather than that of anterior single implant restorations between natural teeth. CONCLUSION: To achieve a favorable level of buccal gingival margin, greater thickness of buccal supra-implant mucosa is required for the implant restorations without a neighboring natural tooth compared to the implant restorations next to a natural tooth.
Humans
;
Molar
;
Mucous Membrane
;
Silicones
;
Tooth
3.A new minimally invasive guided endodontic microsurgery by cone beam computed tomography and 3-dimensional printing technology
Jong Eun KIM ; June Sung SHIM ; Yooseok SHIN
Restorative Dentistry & Endodontics 2019;44(3):e29-
Endodontic microsurgery is defined as the treatment performed on the root apices of an infected tooth, which was unresolved with conventional root canal therapy. Recently, the advanced technology in 3-dimensional model reconstruction based on computed tomography such as cone beam computed tomography has opened a new avenue in application of personalized, accurate diagnosis and has been increasingly used in the field of dentistry. Nevertheless, direct intra-oral localization of root apex based on the 3-dimensional information is extremely difficult and significant amount of bone removal is inevitable when freehand surgical procedure was employed. Moreover, gingival flap and alveolar bone fenestration are usually required, which leads to prolonged time of surgery, thereby increasing the chance of trauma as well as the risk of infection. The purpose of this case report is to present endodontic microsurgery using the guide template that can accurately target the position of apex for the treatment of an anterior tooth with calcified canal which was untreatable with conventional root canal therapy and unable to track the position of the apex due to the absence of fistula.
Apicoectomy
;
Cone-Beam Computed Tomography
;
Dentistry
;
Diagnosis
;
Fistula
;
Humans
;
Microsurgery
;
Printing, Three-Dimensional
;
Root Canal Therapy
;
Tooth
4.The effect of different cooling rates and coping thicknesses on the failure load of zirconia-ceramic crowns after fatigue loading.
Yu Lung TANG ; Jee Hwan KIM ; June Sung SHIM ; Sunjai KIM
The Journal of Advanced Prosthodontics 2017;9(3):152-158
PURPOSE: The purpose of this study was to evaluate the influence of different coping thicknesses and veneer ceramic cooling rates on the failure load of zirconia-ceramic crowns. MATERIALS AND METHODS: Zirconia copings of two different thicknesses (0.5 mm or 1.5 mm; n=20 each) were fabricated from scanning 40 identical abutment models using a dental computer-aided design and computer-aided manufacturing system. Zirconia-ceramic crowns were completed by veneering feldspathic ceramics under different cooling rates (conventional or slow, n=20 each), resulting in 4 different groups (CONV05, SLOW05, CONV15, SLOW15; n=10 per group). Each crown was cemented on the abutment. 300,000 cycles of a 50-N load and thermocycling were applied on the crown, and then, a monotonic load was applied on each crown until failure. The mean failure loads were evaluated with two-way analysis of variance (P=.05). RESULTS: No cohesive or adhesive failure was observed after fatigue loading with thermocycling. Among the 4 groups, SLOW15 group (slow cooling and 1.5 mm chipping thickness) resulted in a significantly greater mean failure load than the other groups (P<.001). Coping fractures were only observed in SLOW15 group. CONCLUSION: The failure load of zirconia-ceramic crowns was significantly influenced by cooling rate as well as coping thickness. Under conventional cooling conditions, the mean failure load was not influenced by the coping thickness; however, under slow cooling conditions, the mean failure load was significantly influenced by the coping thickness.
Adhesives
;
Ceramics
;
Computer-Aided Design
;
Crowns*
;
Fatigue*
5.A study for the bonding strength of composite resin core to glass fiber post.
Tae Hyoung KIM ; June Sung SHIM ; Keun Woo LEE
The Journal of Korean Academy of Prosthodontics 2005;43(4):415-425
STATEMENT OF PROBLEM: Fracture of composite resin core will be occurred by progress of crack. Bonding interface of different materials has large possibility of starting point of crack line. Therefore, the bond strength of glass fiber post to composite resin core is important for prevention of fracture. Purpose: This in vitrostudy tried to find out how to get the higher strength of glass fiber post to composite resin core through surveying the maximum load that fractures the post and core complex. MATERIALS AND METHODS: 40 specimens made with glass fiber Posts(Style post(R), Metalor, Swiss) and composite resin core(Z-100(R), 3M, USA) were prepared and loaded to failure with push-out type shear-bond strength test in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with four different surface treatments. With the data, ANOVA test was used to validate the significance between the test groups, and Bonferroni method was used to check if there is any significant statistical difference between each test group. Every analysis was approved with 95% reliance. RESULTS: On measuring the maximum fracture load of specimens, both the treatments of sandblasted and acid-etched one statistically showed the strength increase rather than the control group(p<0.005). The scanning electric microscope revealed that sand blasting made more micro-retention form not only on the resin matrix but on the glass fiber, and acid-etching contributed to increase in surface retention form, eliminated the inorganic particles in resin matrix. Specimen fracture modes investigation represented that sand blasted groups showed lower bonding failure than no-sand blasted groups. CONCLUSION: Referring to the values of maximum fracture load of specimens, the bonding strength was increased by sand blasting and acid-etching.
Glass*
;
Silicon Dioxide
6.Abrasion resistance of denture base resin including vinyloligosilsesquioxane.
Ran PARK ; June Sung SHIM ; Dong Hoo HAN
The Journal of Korean Academy of Prosthodontics 2003;41(5):626-639
STATEMENT OF PROBLEM: Recently, in attempts to reinforce the acrylic resin and to reduce the polymerization shrinkage, it has been reported that adding vinyloligo-silsesquioxane (vinyl-POSS) to PMMA significantly compensates for polymerization shrinkage and somewhat increases the fracture resistance. PURPOSE: There haven't been any studies on abrasion that can affect the adaptation of the denture in long-term use. In this study, abrasion resistance was compared between acrylic resin with vinyl-POSS and commercialized acrylic resin for denture base. In addition, the difference in abrasion resistance according to molding methods was compared. Material and method : Using PaladentR 20 including vinyl-POSS, PaladentR 20, Lucitone 199R, SR IvocapR, denture bases were fabricated using compression molding technique and continuous-pressure injection technique. Surface hardness and abrasion were measured for each group, and the worn surfaces were observed under a scanning electron microscope. RESULTS: 1. When surface hardness was measured for each material and molding technique, there was no statistically significant difference among the materials. (p<0.05) 2. When same denture base material and molding technique were used, the abrasion due to toothpaste solution was 5 times as severe as the abrasion due to soap solution. 3. When toothpaste solution was used, the abrasion decreased in the order of PaladentR 20, PaladentR 20 including vinyl-POSS, SR IvocapR, and Lucitone 199R. However, statistically significant difference was seen only among PaladentR 20, SR IvocapR, and Lucitone 199R.(p<0.05). 4. When soap solution was used, the abrasion was more severe in PaladentR 20 and including vinyl-POSS PaladentR 20 groups than in SR IvocapR and Lucitone 199R groups. (p<0.05). CONCLUSION: Addition of vinyl-POSS doesn't improve the abrasion resistance, and the abrasion resistance was similar to those of existing materials. Additional studies under different conditions are needed. For clinical application of vinyl-POSS, further investigations with different requirements and conditions are necessary.
Denture Bases*
;
Dentures*
;
Fungi
;
Hardness
;
Polymerization
;
Polymers
;
Polymethyl Methacrylate
;
Soaps
;
Toothpastes
7.Radiographic evaluation of the proximal bone level between two implants: A 3-year comparative study between Branemark and ITI implants in the mandibular posterior region.
Sang Hwa YI ; In Ho CHA ; June Sung SHIM ; Dong Hoo HAN
The Journal of Korean Academy of Prosthodontics 2004;42(4):458-470
STATEMENT OF PROBLEM: Branemark or ITI are two currently most widely used implant systems but with contrasting design, surgical and restoration methods. PURPOSE: The purpose of this study was to compare changes and its statistical significance in bone height and shape which may rise due to the differences between two implant systems. Also to analyse the effect of inter-implant distance on annual bone height changes. MATERIAL & METHOD: Those patients who were treated with two or more of either Branemark or ITI implants at posterior mandibular area at Yonsei University Dental Hospital, Implant Clinic were selected. At annual examination appointments, standardised radiographs using parallel technique were taken. Marginal bone and inter-implant crestal bone changes were measured and following results were obtained. RESULTS: 1) When ITI and Branemark system were compared, both annual marginal and inter-implant crestal bone height changes in ITI system in the first two years were smaller than Branemark and they were statistically significant. On the third year, however, there was no statistical difference between two implant systems on their annual bone level changes (p>0.05). 2) The Marginal and inter-implant crestal bone changes were compared when inter-implant distance was less than 4mm. Statistically significant bone level changes were noted on the first year only for ITI implants but in the first and second year for Branemark implants (p>0.05). 3) When comparing angulation changes between marginal bone and implant fixture, ITI system had smaller angulation changes but the annual changes were not statistically significant (p>0.05). CONCLUSION: Within the limitation of this study, it could be concluded that Branemark implant systems had more changes in marginal and inter-implant crestal bone level in the first and second year after loading with statistical significance. Further studies are recommended to see the effects of these bone loss during the first and second year after loading on the long term prognosis of Branemark Implants.
Appointments and Schedules
;
Humans
;
Prognosis
8.Clinical and radiographical evaluation of implant-supported fixed partial prostheses.
Ji Young SEO ; June Sung SHIM ; Jae Hoon LEE ; Keun Woo LEE
The Journal of Korean Academy of Prosthodontics 2006;44(4):394-403
Statement of problem: A conventional 3-unit fixed partial denture design with a pontic between two retainers is the most commonly used. However, in cases where the mental nerve is in close proximity to the second premolar, a cantilever design can be considered. As such, logical and scientific evidence is lacking for the number and position of implants to be placed for partially edentulous patients, and no clear-cut set of treatment principles currently exist. Purpose: The purpose of this study was to evaluate prognosis of implant-supported fixed partial dentures, and to compare changes in bone level which may rise due to the different factors. Material and method: The present study examined radiographical marginal bone loss in patients treated with implant-supported fixed partial dentures(87 prostheses supported by 227 implants) and evaluated the influence of the span of the pontic, type of the opposing dentition. Clinical complications were studied using a retrospective method. Within the limitation of this study, the following result were drawn. Result: 1. Seven of a total of 227 implants restored with fixed prostheses failed, resulting in a 96.9% success rate. 2. Complications encountered during recall appointments included dissolution of temporary luting agent (17 cases), porcelain fracture (8 cases), loosened screws (5 cases), gingival recession (4 cases), and gingival enlargement (1 case). 3. Marginal bone loss, 1 year after prosthesis placement, was significant(P<0.05) in the group that underwent bone grafting, however no difference in annual resorption rate was observed afterwards. 4. Marginal bone loss, 1 year post-placement, was greater in cantilever-type prostheses than in centric pontic protheses(P<0.05). 5. Marginal bone loss was more pronounced in posterior regions compared to anterior regions(P<0.05). 6. The degree of marginal bone loss was proportional to the length of the pontic(P<0.05). Conclusion: The success rate of implant-supported fixed partial dentures, including marginal bone loss, was satisfactory in the present study. Factors influencing marginal bone loss included whether bone graft was performed, location of the pontic(s), location of the surgical area in the arch, pontic span. Long-term evaluation is necessary for implant-supported fixed partial dentures, as are further studies on the relationship between functional load and the number of implants to be placed.
Appointments and Schedules
;
Bicuspid
;
Bone Transplantation
;
Dental Cements
;
Dental Porcelain
;
Dentition
;
Denture, Partial, Fixed
;
Gingival Recession
;
Humans
;
Logic
;
Prognosis
;
Prostheses and Implants*
;
Retrospective Studies
;
Transplants
9.Interalveolar ridge crest relation analysis and rehabilitation of edentulous patient using dental CAD software: A case report.
Youngsun HONG ; Jong Eun KIM ; June Sung SHIM
The Journal of Korean Academy of Prosthodontics 2019;57(1):31-36
As the number of elderly population increases, the proportion of edentulous patients is increasing, and the demand for traditional dentures will also increase. Arranging the artificial teeth according to the relationship and shape of the upper and lower alveolar ridge is an important factor increasing the stability of the denture. This case is a 79 year old female patient who wishes to make denture covered by national health insurance for psychological and economical reasons. With the alveolar bone severely atrophic, the dental CAD software was used for accurate diagnosis and the posterior teeth were arranged in a cross bite according to the interalveolar crest line angle by the program. After completion, the denture showed adequate stability and maintenance in periodic examinations and treatment, and the patient also expressed high satisfaction.
Aged
;
Alveolar Process
;
Denture, Complete
;
Dentures
;
Diagnosis
;
Female
;
Humans
;
Malocclusion
;
National Health Programs
;
Rehabilitation*
;
Tooth
;
Tooth, Artificial
10.Evaluation of Mechanical Properties of Threedimensional Printed Flexible Denture Resin according to Post-polymerization Conditions: A Pilot Study
Sang-Yub LEE ; Jung-Hwa LIM ; June-Sung SHIM ; Jong-Eun KIM
Journal of Korean Dental Science 2022;15(1):9-18
Purpose:
The purpose of this study was to evaluate whether three-dimensional (3D)-printed flexible denture resin has suitable mechanical properties for use as a thermoplastic denture base resin material.
Materials and Methods:
A total of 96 specimens were prepared using the 3D printed flexible denture resin (Flexible Denture). Specimens were designed in CAD software (Tinkercad) and printed through a digital light-processing 3D printer (Asiga MAX UV). Post-polymerization process was conducted according to air exposure or glycerin immersion at 35°C or 60°C and for 30 or 60 minutes. The maximum flexural strength, elastic modulus, 0.2% offset yield strength, and Vickers hardness of 3D-printed flexible denture resin were assessed.Result: The maximum flexural strength ranged from 64.46±2.03 to 84.25±4.32 MPa, the 0.2% offset yield strength ranged from 35.28±1.05 to 46.13±2.33 MPa, the elastic modulus ranged from 1,764.70±64.66 to 2,179.16±140.01 MPa, and the Vickers hardness ranged from 7.01±0.40 to 11.45±0.69 kg/mm2 .
Conclusion
Within the limits of the present study, the maximum flexural strength, 0.2% offset yield strength, elastic modulus, and Vickers hardness are sufficient for clinical use under the post-polymerization conditions of 60°C at 60 minutes with or without glycerin precipitation.