2.Restoration of E-cadherin by compound 8J protects against cisplatin-induced acute kidney injury by attenuating inflammation and programmed cell death
GAO LI ; LIU MING-MING ; LI JUN ; MENG XIAO-MING
Chinese Journal of Pharmacology and Toxicology 2017;31(10):967-967
OBJECTIVE E-cadherin is a major component of tubular adherent proteins which maintain intercellular contacts and cell polarity in epithelial tissue, it is involved in the pathological process of renal cell carcinoma and fibrotic diseases via epithelial- mesenchymal transition. Although we and others found that expression of E-cadherin was significantly down-regulated in kidney suffered acute kidney injury (AKI), its function in AKI was still unknown, which was explored in the current study. METHODS We disrupted E-cadherin or restored E-cadherin with compound 8J in cisplatin-stimulated tubular epithelial cell lines, the cell damage and inflammation were evaluated, additionally, the thera?peutic potential of E-cadherin restoration was also determined in vivo. RESULTS We found that cisplatin reduced E-cadherin expression both in mouse kidney and tubular epithelial cell lines (mTECs). Adminis?tration of compound 8J restored the level of E-cadherin, thereby increased cell viability while attenuating programmed cell death, which may be mediated by deactivation of RIPK/MLKL axis, reduced membrane translocation of phosphor-MLKL and decreased cleavage of caspase 3. Compound 8J also suppressed inflammatory response in cisplatin- treated mTECs, which was correlated with suppressed NF- κB phorsphorylation and promoter activity. In contrast, disruption of E-cadherin enhanced cell damage and inflammation. Treatment of compound 8J failed to further attenuate kidney damage in E- cadherin knockdown cells, indicating compound 8J protected against mTECs mainly through restoring E-cadherin. We also found that peritoneal injection of compound 8J protected against renal function and tubular damage by preventing NF-κB-driven renal inflammation and RIPK/MLKL-regulated programmed cell death, which was led by restoration of E-cadherin in cisplatin nephropathy. CONCLUSION More than a victim degraded after kidney injury, E-cadherin also has functional role in controlling tubule integrity, programmed cell death and renal inflammation. In this regard, restoration of E-cadherin by compound 8J should be considered as a novel therapeutic strategy for acute kidney injury.
3.Effects of fracture displacement and operation method on perioperative blood loss of femoral neck fractures
Ming GAO ; Haibin WANG ; Jun WANG ; Jie WEI
Chinese Journal of Orthopaedics 2016;(3):162-167
Objective To investigate the effects of fracture displacement and operation method on perioperative blood loss of femoral neck fractures. Methods From December 2013 to October 2014, 130 cases (58 males and 72 females, aged from 18 to 91 years, with an average age of 71.1±12.9 years) with femoral neck fractures were retrospectively analyzed for the periopera?tive blood loss. The degree of displacement was described according to Garden's grades. According to the degree of fracture dis?placement, the patients were divided into two groups:GardenⅠ-Ⅱgroup and Garden Ⅲ-Ⅳgroup, and patients' preoperative hidden blood loss was compared between two groups. According to the degree of fracture displacement and the method of opera?tion, the patients were divided into four groups:Group 1 indicates the group in which patients received cannulated screws fixation for Garden gradeⅠ-Ⅱ;Group 2 in which patients received hemiarthroplasty for Garden gradeⅠ-Ⅱ;Group 3 in which patients received cannulated screws fixation for Garden grade Ⅲ-Ⅳ; Group 4 in which patients received hemiarthroplasty for Garden grade Ⅲ-Ⅳ; and variation in the following four parameters was analyzed: the dominant blood loss, postoperative hidden blood loss, total hidden blood loss, total blood loss in the four different groups. Results For the Garden gradeⅢ-Ⅳfemoral neck frac?ture group, the preoperative hidden blood loss was significantly higher than that of the Garden gradeⅠ-Ⅱfemoral neck fracture group (t=2.267, P=0.001). The dominant blood loss volume, postoperative hidden blood loss volume, total hidden blood loss vol?ume and total blood loss volume of hemiarthroplasty groups (402.1 ± 36.8 ml, 641.3 ± 53.2 ml, 880.7 ± 61.7 ml, 1 246.1 ± 76.7 ml) were higher than those of the cannulated screws fixation group (45.8±34.9 ml, 301.9±50.6 ml, 436.6±58.6 ml, 478.5±72.9 ml). Conclusion The perioperative hidden blood loss is mainly related with the degree of fracture displacement, the greater the de?gree of fracture displacement, the more the preoperative hidden blood loss. While the dominant blood loss volume, postoperative hidden blood loss volume, total hidden blood loss volume and total blood loss volume are mainly related to the method of operation, the blood loss in which patients received hemiarthroplasty should be increased significantly.
4.An epidemiologic study of diabetes mellitus in adolescents in Hanjiang district, Yangzhou
Yanling GAO ; Yan XU ; Jun ZHANG ; Feng SUN ; Ming YANG
Chinese Journal of Endocrinology and Metabolism 2008;24(6):643-644
The prevalence of diabetes mellitus and its relative risk factors in adolescents were investigated in Hanjiang district, Yangzhou. A total of 2 153 adolescents aged from 16 to 18 years old from 7 high schools were enrolled. The prevalence of diabetes mellitus and impaired fasting glucose was 6.13% and 16.12%, respectively. The independent risk factors are obesity or overweight.
5.Bone marrow mesenchymal stem cells transplanted into a rat model of Alzheimer’s disease:improvement in the learning and memory ability
Minglong GAO ; Yingdong ZHANG ; Na LI ; Jun QIAO ; Ming YU
Chinese Journal of Tissue Engineering Research 2016;20(14):2059-2065
BACKGROUND:Drug therapy can partly reduce and delay the progress of Alzheimer’s disease, but only 30%with the single drug treatment obtain clinical cure. OBJECTIVE:To study the therapeutic effect of bone marrow mesenchymal stem cel s transplantation for rats with Alzheimer’s disease. METHODS:Amyloidβ-protein was injected into the hippocampus of Sprague-Dawley rats to construct the model of Alzheimer’s disease. And bone marrow stromal stem cel s were transplanted into the hippocampus of the rat models. RESULTS AND CONCLUSION:At 2 weeks after modeling, compared with the control group, the escape latency in the model and experimental groups was significantly longer (P<0.05), which indicating that Alzheimer’s disease models were successful y established. At 4 weeks after cel transplantation, compared with the model group, the average escape latency in the experimental group was significantly decreased, but retention time on the platform quadrant was significantly prolonged (P<0.05). Besides, at 4 weeks after cel transplantation, expression of choline acetyltransferase in the experimental group was significantly higher than that in the model group (P<0.05). In conclusion, bone marrow mesenchymal stem cel s cannot only differentiate and survive in the hippocampus of rats with Alzheimer’s disease, but also improve the learning and memory ability.
6.Initial clinic verification of internal target volume generated with four-dimensional CT and deformable registration
Jun YANG ; Xingwang GAO ; Xiaowu DENG ; Ming CHEN ; Fugen ZHOU
Chinese Journal of Radiation Oncology 2013;(1):80-83
Objective To study preliminary the accuracy of clinical target volume (CTV) and internal target volume (ITV) automatically generated by an in-house deformable registration software on fourdimensional CT (4DCT),and evaluate its feasibility of clinical application.Methods Clinic treated one lung cancer patient and one liver cancer patient were selected for the study.CTV was delineated by radiation oncologist according to a single respiratory phase image of 4DCT scanning,and then deformed to the other phases and generated the CTVdefm on each phase image.Differences between the CTVdefm and CTVmanu were then compared.A composite ITVcopm was created by overlapping all the CTVdefm of 10 phases and compared with the ITVMIP which was contoured on the maximum intensity projection (MIP) CT images,including the shape,volume and geometric center position of the ITV contour.Results For the tested lung case,average volume difference between the CTVdefm and CTV was (-2.59 ± 5.02)% for the all 10 phases,and the vector departure of the two ITV centers was (1.04 ± 0.89) mm.The ITVcomp almost completely matched the ITVMIP on the tested liver case with a volume difference smaller the 1% and only 1.4 mm vector departure between their geometric centers.Conclusion The validity of the CTVdefm and ITVcomp gained from automatic deformation of manual delineation reference based on 4DCT images were preliminary evaluated and proved to be good enough for clinic planning.
9.Research progress of systemic inflammatory response index in evaluating the prognosis of patients with digestive system malignant tumors
Zhiqiang NIU ; Zhiyong LAI ; Ming GAO ; Qingyao CHANG ; Jun XU
International Journal of Surgery 2021;48(2):132-136
The prognosis of malignant tumors of the digestive system is still a matter of close attention in the medical and health field. At present, evaluating the prognosis of patients with digestive system malignant tumors is mainly based on the TNM staging of the tumor after surgery. As one of the ten characteristics of cancer, inflammatory indicators have certain guiding significance for the prognosis and treatment of patients with malignant tumors of the digestive system. As a new type of inflammation index, the systemic inflammatory response index is significantly better than other traditional inflammatory indexes in evaluating the prognosis of patients with digestive system malignant tumors. This article reviews the related studies on the systemic inflammatory response index in evaluating the prognosis of digestive system malignant tumors.
10.C-arm X-ray machine displacement measurement of acetabular anteversion angle and abduction angle during total hip arthroplasty
Jun CHEN ; Peng FU ; Xugang WANG ; Jun ZHANG ; Ming GAO ; He HUANG ; Shougang WANG
Chinese Journal of Tissue Engineering Research 2016;20(39):5781-5787
BACKGROUND:In total hip arthroplasty, the accurate placement of the acetabulum is needed to guarantee the survival rate of the prosthesis and improve the prognosis. In order to ensure the accurate placement of the acetabulum, the accurate measurement of the abduction angle and the anteversion angle of the acetabulum is needed. OBJECTIVE:To investigate the application value of C-arm X-ray displacement measurement of acetabular anteversion angle and abduction angle in total hip arthroplasty. METHODS:Total y 63 cases undergoing total hip arthroplasty were divided into two groups according to their wil . Patients in the control group (n=30) were implanted with traditional acetabular prosthesis locator. Patients in the observation group (n=33) were implanted with acetabular prosthesis after C-arm X-ray displacement measurement. Acetabular anteversion angle, abduction angle and pelvic inclination were measured before, during and after arthroplasty. Acetabular anteversion angle and abduction angle were measured in both groups after arthroplasty. Pain score and hip function Harris score were recorded in both groups at different time points. RESULTS AND CONCLUSION:(1) No significant difference in acetabular anteversion angle, abduction angle and pelvic inclination was detected before, during and after arthroplasty (al P>0.05). (2) No significant difference in abduction angle was determined between the two groups after arthroplasty (P>0.05), but acetabular anteversion angle was significantly smal er in the observation group than in the control group (P<0.05). (3) At 7 days after arthroplasty, Visual Analog Scale scores were less in the observation group than in the control group (P<0.05). (4) Compared with that before arthroplasty, Harris score was significantly higher after arthroplasty in both groups (P<0.05). Harris score was higher in the observation group than in the control group at 3 and 12 months after arthroplasty (P<0.05). (5) Results indicated that during total hip arthroplasty, C-arm X-ray machine can measure acetabular anteversion angle and abduction angle, and effectively correct pelvic inclination, internal and external rotation, abduction and adduction, improve the accuracy of acetabular cup placement and the quality of replacement surgery, and improve the prognosis of the patients.