1.Investigation on efficacy against hepatocellular carcinoma of novel antisense oligonucleotide targeting IGF1R mRNA encapsulated with neutral cytidinyl/cationic lipid in vitro
Yang PU ; Jing GUAN ; Qian-yi HE ; Yue-jie ZHU ; De-lin PAN ; Zhu GUAN ; Zhen-jun YANG
Acta Pharmaceutica Sinica 2024;59(5):1441-1448
Antisense oligonucleotides are a type of gene therapy that targets mRNA and inhibits gene expression. They have been applied in the treatment of various diseases, but there are still problems with poor enzyme stability and high dosage
2.Nanomaterial-based Therapeutics for Biofilm-generated Bacterial Infections
Zhuo-Jun HE ; Yu-Ying CHEN ; Yang ZHOU ; Gui-Qin DAI ; De-Liang LIU ; Meng-De LIU ; Jian-Hui GAO ; Ze CHEN ; Jia-Yu DENG ; Guang-Yan LIANG ; Li WEI ; Peng-Fei ZHAO ; Hong-Zhou LU ; Ming-Bin ZHENG
Progress in Biochemistry and Biophysics 2024;51(7):1604-1617
Bacterial biofilms gave rise to persistent infections and multi-organ failure, thereby posing a serious threat to human health. Biofilms were formed by cross-linking of hydrophobic extracellular polymeric substances (EPS), such as proteins, polysaccharides, and eDNA, which were synthesized by bacteria themselves after adhesion and colonization on biological surfaces. They had the characteristics of dense structure, high adhesiveness and low drug permeability, and had been found in many human organs or tissues, such as the brain, heart, liver, spleen, lungs, kidneys, gastrointestinal tract, and skeleton. By releasing pro-inflammatory bacterial metabolites including endotoxins, exotoxins and interleukin, biofilms stimulated the body’s immune system to secrete inflammatory factors. These factors triggered local inflammation and chronic infections. Those were the key reason for the failure of traditional clinical drug therapy for infectious diseases.In order to cope with the increasingly severe drug-resistant infections, it was urgent to develop new therapeutic strategies for bacterial-biofilm eradication and anti-bacterial infections. Based on the nanoscale structure and biocompatible activity, nanobiomaterials had the advantages of specific targeting, intelligent delivery, high drug loading and low toxicity, which could realize efficient intervention and precise treatment of drug-resistant bacterial biofilms. This paper highlighted multiple strategies of biofilms eradication based on nanobiomaterials. For example, nanobiomaterials combined with EPS degrading enzymes could be used for targeted hydrolysis of bacterial biofilms, and effectively increased the drug enrichment within biofilms. By loading quorum sensing inhibitors, nanotechnology was also an effective strategy for eradicating bacterial biofilms and recovering the infectious symptoms. Nanobiomaterials could intervene the bacterial metabolism and break the bacterial survival homeostasis by blocking the uptake of nutrients. Moreover, energy-driven micro-nano robotics had shown excellent performance in active delivery and biofilm eradication. Micro-nano robots could penetrate physiological barriers by exogenous or endogenous driving modes such as by biological or chemical methods, ultrasound, and magnetic field, and deliver drugs to the infection sites accurately. Achieving this using conventional drugs was difficult. Overall, the paper described the biological properties and drug-resistant molecular mechanisms of bacterial biofilms, and highlighted therapeutic strategies from different perspectives by nanobiomaterials, such as dispersing bacterial mature biofilms, blocking quorum sensing, inhibiting bacterial metabolism, and energy driving penetration. In addition, we presented the key challenges still faced by nanobiomaterials in combating bacterial biofilm infections. Firstly, the dense structure of EPS caused biofilms spatial heterogeneity and metabolic heterogeneity, which created exacting requirements for the design, construction and preparation process of nanobiomaterials. Secondly, biofilm disruption carried the risk of spread and infection the pathogenic bacteria, which might lead to other infections. Finally, we emphasized the role of nanobiomaterials in the development trends and translational prospects in biofilm treatment.
3.Classification Method for Petroleum Pollutants Based on Inception-One-Dimensional Convolutional Neural Network and Infrared Spectroscopy
De-Ming KONG ; Shao-Wei HE ; Xin-Yi LI ; Jun-Yu ZHAO ; Xiao-Dong NING
Chinese Journal of Analytical Chemistry 2024;52(9):1287-1297
Infrared spectroscopy technology has many advantages such as high efficiency and non-destructiveness,and has an important research and application value in the field of petroleum pollutant classification and detection.In this study,a petroleum pollutant classification method by combing the discrete wavelet transform(DWT)algorithm and a one-dimensional convolutional neural network based on the Inception module(Inception-1D-CNN)was proposed.Firstly,the DWT algorithm was used to denoise the original infrared spectral data to eliminate the interference information caused by experimental environment,instrument error and manual operation.Then,the inception-1D-CNN model was used to obtain multi-scale infrared spectroscopy feature information,and then classify the petroleum pollutants.Experimental results showed that compared with preprocessing methods such as standard normal variable(SNV),adaptive iteratively reweighted penalized least squares(AirPLS),and Savitzky-Golay smoothing(S-G),the prediction accuracy of the DWT algorithm combined with the 1D-CNN model with a convolutional kernel size of 3×1 was 86.6%,which was 6.6%,6.6%and 3.3%higher,respectively.The prediction accuracy of DWT algorithm combined with 1D-CNN model with a convolutional kernel size of 5×1 was 93.3%,which was 10.0%,7.0%and 3.3%higher,respectively.The prediction accuracy of the DWT algorithm combined with the 1D-CNN model with a convolutional kernel size of 7×1 was 90.0%,which was 6.7%,10.0%and 3.4%higher,respectively.The prediction accuracy of the DWT algorithm combined with the inception-1D-CNN model was 100.0%,which was 10.0%,10.0%and 3.4%higher,respectively.Therefore,the DWT algorithm combined with the inception-1D-CNN model could accurately classify and predict petroleum pollutants,and provided a certain basis for the subsequent treatment of oil spills on the sea surface.
4.Clinical Efficacy of Bushen Yij ing Decoction for the Treatment of Xerophthalmia of Kidney Yang Deficiency Type and the Analysis of Th1/Th17 Cytokines
Wen-Jing HU ; Ting-Ting HU ; Zhang-Qing HE ; Wen-Fen CHEN ; De-Li ZENG ; Jun ZENG
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(5):1213-1219
Objective To investigate the clinical efficacy of Bushen Yijing Decoction for the treatment of xerophthalmia of kidney yang deficiency type and to observe its effect on serum Th1/Th17 cytokines.Methods From January 2021 to January 2023,a total of 96 patients with xerophthalmia of kidney yang deficiency type were selected as the study objects.According to the treatment methods,the patients were divided into observation group and control group,with 48 cases in each group.The control group was treated with Sodium Hyaluronate Eye Drops externally,and the observation group was given oral use of Bushen Yijing Decoction together with Sodium Hyaluronate Eye Drops externally.The course of treatment for the two groups covered 21 days.The changes of tear film break-up time(BUT),corneal fluorescein staining(FL)score,SchirmerⅠtest(SIT)value,serum Th1/Th17 cytokines,Ocular Surface Disease Index(OSDI)questionnaire scores,and 25-Item National Eye Institute Visual Function Questionnaire(NEI-VFQ-25)score in the two groups were observed before and after treatment.Moreover,the clinical efficacy and incidence of adverse reactions were compared between the two groups.Results(1)After 21 days of treatment,the total effective rate of the observation group was 95.83%(46/48),and that of the control group was 70.83%(34/48).The intergroup comparison(tested by chi-square test)showed that the clinical efficacy of the observation group was significantly superior to that of the control group(P<0.01).(2)After treatment,the ocular surface function indicators of BUT and SIT values in the two groups were higher and the FL values were lower than those before treatment(P<0.05).The increase of BUT and SIT values and the decrease of FL values in the observation group were significantly superior to those in the control group(P<0.01).(3)After treatment,the levels of serum cytokines of interleukin 17(IL-17),tumor necrosis factor alpha(TNF-α)and interferon gamma(IFN-γ)in the two groups were lower than those before treatment(P<0.05),and the decrease of serum IL-17,TNF-α and IFN-γ levels in the observation group was significantly superior to that in the control group(P<0.01).(4)After treatment,the questionnaire scores of OSDI in the two groups were lower and the NEI-VFQ-25 scores were higher than those before treatment(P<0.05).The decrease of OSDI scores and the increase of NEI-VFQ-25 scores in the observation group were significantly superior to those in the control group(P<0.01).(5)The incidence of adverse reactions in the observation group was 4.17%(2/48),and that in the control group was 8.33%(4/48).There was no significant difference between the two groups(P>0.05).Conclusion Bushen Yijing Decoction can enhance the clinical efficacy of xerophthalmia of kidney yang deficiency type,and the decoction is effective on alleviating the eye discomforts,improving the ocular surface function of patients,regulating the levels of Th1/Th17 cytokines,and relieving the inflammatory response without inducing severe adverse reactions while with high safety.
5.Clinical characterization and prediction modeling of lung cancer patients with high energy metabolism
Jiang-Shan REN ; Jun-Mei JIA ; Ping SUN ; Mei PING ; Qiong-Qiong ZHANG ; Yan-Yan LIU ; He-Ping ZHAO ; Yan CHEN ; Dong-Wen RONG ; Kang WANG ; Hai-Le QIU ; Chen-An LIU ; Yu-Yu FAN ; De-Gang YU
Medical Journal of Chinese People's Liberation Army 2024;49(9):1004-1010
Objective To analyze the clinical characteristics of high energy metabolism in lung cancer patients and its correlation with body composition,nutritional status,and quality of life,and to develop a corresponding risk prediction model.Methods Retrospectively analyzed 132 primary lung cancer patients admitted to the First Hospital of Shanxi Medical University from January 2022 to May 2023,and categorized into high(n=94)and low energy metabolism group(n=38)based on their metabolic status.Differences in clinical data,body composition,Patient Generated Subjective Global Assessment(PG-SGA)scores,and European Organization for Research and treatment of Cancer(EORTC)Quality of Life Questionnaire-Core 30(QLQ-C30)scores were compared between the two groups.Logistic regression was used to identify the risk factors for high energy metabolism in lung cancer patients,and a risk prediction model was established accordingly;the Hosmer-Lemeshow test was used to assess the model fit,and the ROC curve was used to test the predictive efficacy of the model.Results Of the 132 patients with primary lung cancer,94(71.2%)exhibited high energy metabolism.Compared with low energy metabolism group,patients in high-energy metabolism group had a smoking index of 400 or higher,advanced disease staging of stage Ⅲ or Ⅳ,and higher levels of IL-6 level,low adiposity index,low skeletal muscle index,and malnutrition(P<0.05),and lower levels of total protein,albumin,hemoglobin level,and prognostic nutritional index(PNI)(P<0.05).There was no significant difference in age,gender,height,weight,BMI and disease type between the two groups(P>0.05).Logistic regression analysis showed that smoking index≥400,advanced disease stage,IL-6≥3.775 ng/L,and PNI<46.43 were independent risk factors for high energy metabolism in lung cancer patients.The AUC of the ROC curve for the established prediction model of high energy metabolism in lung cancer patients was 0.834(95%CI 0.763-0.904).Conclusion The high energy metabolic risk prediction model of lung cancer patients established in this study has good fit and prediction efficiency.
6.A comparative study of chronic obstructive pulmonary disease models in rats established by exposure to cigarette smoke and motor vehicle exhaust
De-Fu LI ; Yuan-Yuan YE ; Hong-Ping ZHANG ; Run-Hua HOU ; Yao-Jun HE ; Chun-Yun ZHANG ; Jie-Ying HU ; Rui CHEN
Medical Journal of Chinese People's Liberation Army 2024;49(9):1038-1044
Objective To compare the fidelity of chronic obstructive pulmonary disease(COPD)models established using two methods:exposure to cigarette smoke(CS)and exposure to motor vehicle exhaust(MVE)in rats.Methods Twenty-four male SD rats were randomly divided into control,CS-exposed(CS),and MVE-exposed(MVE)groups,with 8 rats per group.Rats in CS and MVE groups were exposed to CS or MVE,respectively,to induce COPD models.After COPD model established,lung function of each group was assessed.Bronchoalveolar lavage fluid(BALF)was collected to measure inflammatory cell counts,levels of inflammatory cytokines interleukin-6(IL-6)and tumor necrosis factor(TNF)-α,and expression levels of mucin 5AC(MUC5AC).Lung tissue sections were stained with hematoxylin and eosin(HE)to observe pulmonary tissue and airway pathological changes.Periodic acid-Schiff(PAS)staining was used to detect goblet cell hyperplasia in airways.Results Compared with control group,rats in CS and MVE groups showed significantly increased inspiratory resistance(RI),total lung capacity(TLC),and lung static compliance(Cchord)(P<0.05),while expiratory flow parameters FEV50/FVC were significantly decreased(P<0.05).Compared with MVE group,rats in CS group had significantly higher RI,TLC,and Cchord(P<0.05),and lower FEV50/FVC(P<0.05).HE staining of lung tissues showed that mean linear intercept(MLI)was significantly higher in both CS and MVE groups compared with control group(P<0.05),with CS group having higher MLI than MVE group(P<0.05).BALF analysis revealed that white blood cells,neutrophils,macrophages,lymphocytes,IL-6,and TNF-α levels were significantly higher in both CS and MVE groups compared with control group(P<0.05),and inflammatory cell counts,IL-6,and TNF-α levels were higher in CS group compared with MVE group(P<0.05).PAS staining of lung tissues indicated that goblet cells in large airways were significantly increased in both CS and MVE groups compared with control group(P<0.05),with CS group showing higher goblet cell counts than MVE group(P<0.05).Expression levels of MUC5AC in BALF were significantly higher in both CS and MVE groups compared with control group(P<0.05),with CS group having significantly higher MUC5AC levels than MVE group(P<0.05).Conclusions Exposure to CS or MVE can establish a rat model of COPD,with CS exposure better mimicking characteristics of acute exacerbation of COPD compared to MVE exposure.
7.Interpretation of the 2023"Guidelines for parenteral nutrition in preterm infants:the American Society for Parenteral and Enteral Nutrition"
Xin-Yu ZHANG ; Yang HE ; Jun TANG ; Jia-Jie YU ; Jun-Jie YING ; De-Zhi MU
Chinese Journal of Contemporary Pediatrics 2024;26(8):795-802
The"Guidelines for parenteral nutrition in preterm infants:the American Society for parenteral and enteral nutrition"were developed by the American Society for Parenteral and Enteral Nutrition and published in the Journal of Parenteral and Enteral Nutrition in September 2023.The guidelines provide recommendations on 12 key clinical questions regarding parenteral nutrition(PN)for preterm infants.In comparison to similar guidelines,this set offers more detailed perspectives on PN for preterm infants.It presents evidence-based recommendations for the commencement time,nutrient dosage,and composition of PN,considering primary outcomes such as growth and development,as well as secondary outcomes like sepsis,retinopathy of prematurity,parenteral nutrition-related liver disease,and jaundice.This article aims to interpret the guidelines to provide a reference for colleagues in the field.
8.pH and GSH dual-responsive silybin nano-micelles for inhibition of breast cancer activity and metastasis in vitro
Ling-yu JIA ; Dan-li HAO ; Jia-ying YANG ; Ran XIE ; Ge-jing DE ; Hong YI ; Chen ZANG ; Yu ZHAO ; Qing-he ZHAO ; Yan-jun CHEN
Acta Pharmaceutica Sinica 2023;58(9):2785-2793
The clinical tumor therapy was greatly challenged due to the complex characteristics of tumor microenvironment, however, which also provide arena for novel therapeutic strategies. In this study, poly(2-ethyl-2-oxazoline)-poly(lactic acid)-SS-poly(
9.Epidemiological Survey of Hemoglobinopathies Based on Next-Generation Sequencing Platform in Hunan Province, China.
Hui XI ; Qin LIU ; Dong Hua XIE ; Xu ZHOU ; Wang Lan TANG ; De Guo TANG ; Chun Yan ZENG ; Qiong WANG ; Xing Hui NIE ; Jin Ping PENG ; Xiao Ya GAO ; Hong Liang WU ; Hao Qing ZHANG ; Li QIU ; Zong Hui FENG ; Shu Yuan WANG ; Shu Xiang ZHOU ; Jun HE ; Shi Hao ZHOU ; Fa Qun ZHOU ; Jun Qing ZHENG ; Shun Yao WANG ; Shi Ping CHEN ; Zhi Fen ZHENG ; Xiao Yuan MA ; Jun Qun FANG ; Chang Biao LIANG ; Hua WANG
Biomedical and Environmental Sciences 2023;36(2):127-134
OBJECTIVE:
This study was aimed at investigating the carrier rate of, and molecular variation in, α- and β-globin gene mutations in Hunan Province.
METHODS:
We recruited 25,946 individuals attending premarital screening from 42 districts and counties in all 14 cities of Hunan Province. Hematological screening was performed, and molecular parameters were assessed.
RESULTS:
The overall carrier rate of thalassemia was 7.1%, including 4.83% for α-thalassemia, 2.15% for β-thalassemia, and 0.12% for both α- and β-thalassemia. The highest carrier rate of thalassemia was in Yongzhou (14.57%). The most abundant genotype of α-thalassemia and β-thalassemia was -α 3.7/αα (50.23%) and β IVS-II-654/β N (28.23%), respectively. Four α-globin mutations [CD108 (ACC>AAC), CAP +29 (G>C), Hb Agrinio and Hb Cervantes] and six β-globin mutations [CAP +8 (C>T), IVS-II-848 (C>T), -56 (G>C), beta nt-77 (G>C), codon 20/21 (-TGGA) and Hb Knossos] had not previously been identified in China. Furthermore, this study provides the first report of the carrier rates of abnormal hemoglobin variants and α-globin triplication in Hunan Province, which were 0.49% and 1.99%, respectively.
CONCLUSION
Our study demonstrates the high complexity and diversity of thalassemia gene mutations in the Hunan population. The results should facilitate genetic counselling and the prevention of severe thalassemia in this region.
Humans
;
beta-Thalassemia/genetics*
;
alpha-Thalassemia/genetics*
;
Hemoglobinopathies/genetics*
;
China/epidemiology*
;
High-Throughput Nucleotide Sequencing
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail