1.Mushrooms: An Important Source of Natural Bioactive Compounds
Ji Won HA ; Juhui KIM ; Hyunwoo KIM ; Wonyoung JANG ; Ki Hyun KIM
Natural Product Sciences 2020;26(2):118-131
Mushrooms are known for their various attributes in the fields of nutrition and therapeutics. With exceptional taste, aroma, and nutritional value, they are considered ‘functional food’-improving health and providing nutritional benefits to the body. Mushrooms have also been widely applied therapeutically as they possess diverse bioactive compounds known as secondary metabolites. These secondary metabolites demonstrated diverse biological properties such as anticancer, anti-diabetic, immunomodulatory, antimicrobial, anti-inflammatory, antiviral, anti-allergic, and antioxidative activities. This review presents bioactive compounds from the field of mushroom metabolite research and discusses important findings regarding bioactive compounds identified during the last five years (2015 – 2019).
2.Development of an Automatic Pill Image Data Generation System
Juhui LEE ; Soyoon KWON ; Jong Hoon KIM ; Kwang Gi KIM
Healthcare Informatics Research 2023;29(1):84-88
Objectives:
Since the easiest way to identify pills and obtain information about them is to distinguish them visually, many studies on image processing technology exist. However, no automatic system for generating pill image data has yet been developed. Therefore, we propose a system for automatically generating image data by taking pictures of pills from various angles. This system is referred to as the pill filming system in this paper.
Methods:
We designed the pill filming system to have three components: structure, controller, and a graphical user interface (GUI). This system was manufactured with black polylactic acid using a 3D printer for lightweight and easy manufacturing. The mainboard controls data storage, and the entire process is managed through the GUI. After one reciprocating movement of the seesaw, the web camera at the top shoots the target pill on the stage. This image is then saved in a specific directory on the mainboard.
Results:
The pill filming system completes its workflow after generating 300 pill images. The total time to collect data per pill takes 21 minutes and 25 seconds. The generated image size is 1280 × 960 pixels, the horizontal and vertical resolutions are both 96 DPI (dot per inch), and the file extension is .jpg.
Conclusions
This paper proposes a system that can automatically generate pill image data from various angles. The pill observation data from various angles include many cases. In addition, the data collected in the same controlled environment have a uniform background, making it easy to process the images. Large quantities of high-quality data from the pill filming system can contribute to various studies using pill images.
3.Primary Lymphoma of Cervix
Ji Eun SHIM ; Juhui KIM ; Mi-Kyung KIM ; Yun Hwan KIM ; Seung Cheol KIM
The Ewha Medical Journal 2021;44(2):41-45
Lymphomas that originate from the female genital tract are very rare. Primary cervical lymphoma only accounts for less than 1% of all extra-nodal lymphomas. Clinical manifestations of primary cervical lymphoma can be nonspecific, vaginal bleeding being the most common symptom, and this makes timely diagnosis often difficult. Prognosis and optimal treatment have yet been established due to the rarity of the disease. In this article, a rare case of primary diffuse large B-cell lymphoma of cervix is reported with a review of the available literature.
4.Primary Lymphoma of Cervix
Ji Eun SHIM ; Juhui KIM ; Mi-Kyung KIM ; Yun Hwan KIM ; Seung Cheol KIM
The Ewha Medical Journal 2021;44(2):41-45
Lymphomas that originate from the female genital tract are very rare. Primary cervical lymphoma only accounts for less than 1% of all extra-nodal lymphomas. Clinical manifestations of primary cervical lymphoma can be nonspecific, vaginal bleeding being the most common symptom, and this makes timely diagnosis often difficult. Prognosis and optimal treatment have yet been established due to the rarity of the disease. In this article, a rare case of primary diffuse large B-cell lymphoma of cervix is reported with a review of the available literature.
5.Listeriosis in a Pregnant Woman and a Neonate
Ha Young YUN ; Juhui KIM ; Su Jin CHO ; Eun Ae PARK ; Young Ju KIM ; Sunwha PARK
The Ewha Medical Journal 2020;43(4):60-64
Listeriosis is an infectious disease caused by Listeria monocytogenes. It’s rare in healthy adults, it could be fatal in pregnant women. Listeriosis in pregnant women causes fever and flu-like symptoms, but could lead to fatal consequences. However, because there are few cases of listeriosis reported in Korea, the symptoms are ambiguous and the standard diagnostic tool has yet to be determined, making accurate diagnosis difficult. We present a case of a 35-year-old pregnant woman who had fever and headache. Initially, we didn’t find the cause of fever. However, after delivery, L. monocytogenes was detected in the neonatal gastric aspirate culture, blood cultures. The placenta and amniotic membrane showed acute suppurative inflammation and chorioamnionitis. The mother recovered after antibiotic treatment and delivery, but in the case of the newborn baby, the patient died despite treatment. We report a case of listeriosis in a pregnant woman and a neonate with literature review.
6.Design of Automatic Hand Sanitizer System Compatible with Various Containers
Juhui LEE ; Jin-Young LEE ; Sung-Min CHO ; Ki-Cheol YOON ; Young Jae KIM ; Kwang Gi KIM
Healthcare Informatics Research 2020;26(3):243-247
Objectives:
Demand for hand sanitizers has surged since the coronavirus broke out and spread around the world. Hand sanitizers are usually applied by squirting the sanitizer liquid when one presses a pump with one’s hand. This causes many people to come into contact with the pump handle, which increases the risk of viral transmission. Some hand sanitizers on the market are automatically pumped. However, because sanitizer containers and pump devices are designed to be compatible only between products produced by the same manufacturer, consumers must also repurchase the container for the liquid if they replace the hand sanitizer. Therefore, this paper suggests the design of an automatic hand sanitizer system compatible with various sanitizer containers.
Methods:
An automatic hand sanitizer system was designed, which will be presented in two stages describing the instrument structure and control parts. This work focused on using the elasticity of pumps and improving people’s access to devices.
Results:
We have designed an automatic hand sanitizer system that is compatible with various containers. When one moves one’s hand close to the device sensor, the hand sanitizer container is pumped once.
Conclusions
The automatic hand sanitizer device proposed in this paper is ultimately expected to contribute to contactless hand disinfection in public places and virus infection prevention. Additionally, it is economical and eco-friendly by decreasing waste emissions.
7.Clinical experience of robotic myomectomy for fertility preservation using preoperative magnetic resonance imaging predictor
So Yun PARK ; Juhui KIM ; Kyungah JEONG ; Sung Il JUNG ; Young Min HUR ; Eun Hye CHO ; Hye-Sung MOON ; Hye Won CHUNG
Obstetrics & Gynecology Science 2020;63(6):726-734
Objective:
This study aimed to demonstrate the use of preoperative magnetic resonance imaging (MRI) findings to select the optimal surgical technique between single-site (SS) and multi-site (MS) robotic myomectomy based on clinical experience, for the preservation of fertility.
Methods:
Ninety-eight patients who underwent SS or MS robotic myomectomy using the da Vinci® Si system after undergoing MRI were evaluated retrospectively. The correlation between preoperative MRI findings and the intraoperative or postoperative findings during robotic myomectomy for the preservation of fertility was analyzed. The reproductive outcome was investigated when the patient wished to conceive.
Results:
The mean age of the patients was 35.68±5.04 years and 80 patients (81.6%) were nulliparous. The total diameter of myomas on MRI was 106.75±54.52 mm. The number of resected myomas was 4.31±4.39 (range, 1–27), and the total weight of resected myomas was 293.11±281.13 (range, 30–1,260) g. Myomas with high signal intensity on MRI required less time for resection. MS robotic myomectomy was performed for an increased number and total diameter of a myoma or a deep-seated myoma. Postoperatively, all patients resumed normal menstruation. Of the 15 patients who wished to conceive, 12 (80%) conceived successfully. Of these, uterine dehiscence occurred in 1 patient and 10 patients underwent an uneventful cesarean section.
Conclusion
SS or MS robotic myomectomy can be recommended for patients who wish to conserve fertility. However, the optimal surgical technique should be selected based on preoperative MRI findings to predict an effective surgical process and the successful preservation of fertility.
8.Association between Thyroid Function and Heart Rate Monitored by Wearable Devices in Patients with Hypothyroidism
Ki-Hun KIM ; Juhui LEE ; Chang Ho AHN ; Hyeong Won YU ; June Young CHOI ; Ho-Young LEE ; Won Woo LEE ; Jae Hoon MOON
Endocrinology and Metabolism 2021;36(5):1121-1130
Background:
Heart rate (HR) monitored by a wearable device (WD) has demonstrated its clinical feasibility for thyrotoxicosis subjects. However, the association of HR monitored by wearables with hypothyroidism has not been examined. We assessed the association between serum thyroid hormone concentration and three WD-HR parameters in hypothyroid subjects.
Methods:
Forty-four subjects scheduled for radioactive iodine therapy (RAI Tx) after thyroid cancer surgery were included. Thirty subjects were prepared for RAI Tx by thyroid hormone withdrawal (hypothyroidism group) and 14 subjects by recombinant human thyrotropin (control group). Three WD-HR parameters were calculated from the HR data collected during rest, during sleep, and from 2:00 AM to 6:00 AM, respectively. We analyzed the changes in conventionally measured resting HR (On-site rHR) and WDHR parameters relative to thyroid hormone levels.
Results:
Serum free thyroxine (T4) levels, On-site rHR, and WD-HR parameters were lower in the hypothyroid group than in the control group at the time of RAI Tx. WD-HR parameters also reflected minute changes in free T4 levels. A decrease in On-site rHR and WD-HR parameters by one standard deviation (On-site rHR, approximately 12 bpm; WD-HR parameters, approximately 8 bpm) was associated with a 0.2 ng/dL decrease in free T4 levels (P<0.01) and a 2-fold increase of the odds ratio of hypothyroidism (P<0.01). WD-HR parameters displayed a better goodness-of-fit measure (lower quasi-information criterion value) than On-site rHR in predicting the hypothyroidism.
Conclusion
This study identified WD-HR parameters as informative and easy-to-measure biomarkers to predict hypothyroidism.
9.Clinical experience of robotic myomectomy for fertility preservation using preoperative magnetic resonance imaging predictor
So Yun PARK ; Juhui KIM ; Kyungah JEONG ; Sung Il JUNG ; Young Min HUR ; Eun Hye CHO ; Hye-Sung MOON ; Hye Won CHUNG
Obstetrics & Gynecology Science 2020;63(6):726-734
Objective:
This study aimed to demonstrate the use of preoperative magnetic resonance imaging (MRI) findings to select the optimal surgical technique between single-site (SS) and multi-site (MS) robotic myomectomy based on clinical experience, for the preservation of fertility.
Methods:
Ninety-eight patients who underwent SS or MS robotic myomectomy using the da Vinci® Si system after undergoing MRI were evaluated retrospectively. The correlation between preoperative MRI findings and the intraoperative or postoperative findings during robotic myomectomy for the preservation of fertility was analyzed. The reproductive outcome was investigated when the patient wished to conceive.
Results:
The mean age of the patients was 35.68±5.04 years and 80 patients (81.6%) were nulliparous. The total diameter of myomas on MRI was 106.75±54.52 mm. The number of resected myomas was 4.31±4.39 (range, 1–27), and the total weight of resected myomas was 293.11±281.13 (range, 30–1,260) g. Myomas with high signal intensity on MRI required less time for resection. MS robotic myomectomy was performed for an increased number and total diameter of a myoma or a deep-seated myoma. Postoperatively, all patients resumed normal menstruation. Of the 15 patients who wished to conceive, 12 (80%) conceived successfully. Of these, uterine dehiscence occurred in 1 patient and 10 patients underwent an uneventful cesarean section.
Conclusion
SS or MS robotic myomectomy can be recommended for patients who wish to conserve fertility. However, the optimal surgical technique should be selected based on preoperative MRI findings to predict an effective surgical process and the successful preservation of fertility.