1.A STUDY ON ACCUARACY AND DIMENSIONAL STABILITY ACCORDING TO IMPRESSION METHODS.
Jae Young LEE ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 1999;37(5):567-580
Accurate reproduction of intraoral tissue is essential in the fabrication of fixed prosthesis. This selection of impression material and method is very important. In this study, vinyl polysiloxane type impression material Panasil was used. Three impression methods ; one-step technique, individual tray technique, and individual tooth tray technique using the vinyl polysiloxane type bite registration material Futar Occlusion, were used to take horizontal and vertical impression. Improved stone models were fabricated. The amount of occlusal surface discrepaneies, interabutment distance discrepancies, amount of marginal defect were evaluated with the X-PLAN360d and photoscanning. The results were as follows. 1. There was no significant difference in occlusal surface according to the directions and techniques of impression taking. 2. There was no significant difference in interabutment distance discrepancies according to the directions and techniques of impression taking 3. There was no significant difference in marginal discrepancies according to the direction of impression taking but there was significant difference between one-step technique and individual tray technique, individual tooth tray technique (P<0.05). Taken together, these results suggest that individual tray technique and individual tooth tray technique are more accurate for impression taking than one-step technique.
Jaw Relation Record
;
Prostheses and Implants
;
Reproduction
;
Siloxanes
;
Tooth
2.A Study On The Color Stability Of Porcelain For Porcelain Fused To Metal Crown.
So Young RYU ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(1):73-84
Dental porcelain should have adequate strength and similar esthetics as natural teeth. Recently esthetics has become a high priority in clinical dentistry. Thus the evaluation of color stability of dental porcelain has become an important part in dental research. The purpose of this study was to evaluate the difference in color stability of 3 types of porcelain (Vintage, VMK 95, CERAMCO II). The porcelain were divided into groups by 2 types of treatment (Glazing or non-glazing and thermocycling or non-thermocycling). The porcelain wee dyed with methylene blue and distilled water, and then the color stability was evaluated with a spectrophotometer. The results were as follow ; 1. The color change of porcelain increased in the order of VMK 95, Vintage, CERAMCO II. But there was no significant difference. 2. The color change decreased in the glazing group compared to the non-glazing group(p<0.05). 3. The color change increased after thermocycling But there was no significant difference. 4. The color change according to dye method was significantly larger with methylene blue copared to distilled water(P<0.05).
Crowns*
;
Dental Porcelain*
;
Dental Research
;
Dentistry
;
Esthetics
;
Methylene Blue
;
Tooth
;
Water
3.Quantitative Changes of Immunoglobun Levels in the Serum of Allergic Dermatoses Patients.
Chung Ju LEE ; Soo Duk LIM ; Sung Hwan KIM
Korean Journal of Dermatology 1969;7(1):1-7
With development of immunochemical methods for anlysis of serum proteins, quantitative determination of serum immunoglobulin levels and purification of them have been made possible in recent years. There are numerous reports about immunoglobulin levels in various diseases. A search of the literature reveals very few reports of quantitative immunoglobulin determinations in allergic dermatoses. The present study was conducted to find quantitative changes of serum immunoglobulins in a few allergic dermatoses. To quantify the IgG, IgA and IgM, one hundred and two sera were analysed form 30 normal control group, 30 contact dermatitis patients, 12 stopic dermatitis patients and 30 urticaria patients by modified Oudin's capillary tube method. The results are as follows. 1.In contact dermatitis the IgG was significantly increased to compare with control group(p<0.01) 2.In atopic dermatitis the IgA was significantly increased to compare with control group(p<0.01) 3.In urticaria the IgG was increased (p<0.05) 4.The IgM has no differences between allergic dermatoses and control group.
Blood Proteins
;
Capillaries
;
Dermatitis
;
Dermatitis, Atopic
;
Dermatitis, Contact
;
Humans
;
Immunoglobulin A
;
Immunoglobulin G
;
Immunoglobulin M
;
Immunoglobulins
;
Skin Diseases*
;
Urticaria
4.A STUDY ON THE EFFECT OF UV LIGHT ABSORBER ON THE COLOR CHANGE OF MAXILLOFACIAL SILICONE.
Yun Seok SONG ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 1999;37(3):343-357
The color change of maxillofacial silicone has been attributed to certain environmental factors such as exposure to the UV component of natural sunlight, wetting and drying of the elastomer, and surface abrasion resulting from the application and removal of cosmetics. The purpose of this study was to evaluate the color change of maxillofacial silicone (Silastic MDX4-4210) according to type of pigment (cadmium yellow, titanium white, cosmetic red), and UV absorber application method after 200, 400, and 600 hours of 350nm UV light irradiation. The results were as follows. 1. According to type of pigments, after 200 hours cosmetic red showed significantly larger color change than cadmium yellow and titanium white, and after 400 and 600 hours color change significantly decreased in the order of cosmetic red, cadmium yellow, and titanium white (p<0.05). 2. In the cadmium yellow group, after 200 hours, the non-treatment group showed significantly larger color change, but after 400 and 600hours, color change significantly decreased in the order of non-treatment, surface application and mixed group (p<0.05). 3. In the titanium white group, there was no significant color change difference between the three groups after 200 and 400 hours, but after 600 hours, the mixed group showed significantly smaller color change than the non-treatment and surface application groups (p<0.05). 4. In the cosmetic red group, there was significant decrease in color change in the order non-treatment, surface application and mixed group (p<0.05). From the results above, the effect of UV light absorber differed according to the type of pigment, but mixing UV light aborber with maxillofacial silicone is thought to give superior resistance against UV light irradiation in the long run.
Cadmium
;
Elastomers
;
Silicones*
;
Sunlight
;
Titanium
;
Ultraviolet Rays*
5.Successful Extracorporeal Membrane Oxygenation Support for Acute Pulmonary Thromboembolism during Adult Liver Transplantation.
Ju Yong LIM ; Pil Je KANG ; Doo Hwan KIM
Korean Journal of Critical Care Medicine 2016;31(4):371-374
No abstract available.
Adult*
;
Extracorporeal Membrane Oxygenation*
;
Humans
;
Liver Transplantation*
;
Liver*
;
Pulmonary Embolism*
6.MARGINAL FIDELITY AND FRACTURE STRENGTH OF IN-CERAM CROWNS ACCORDING TO VARIOUS RESIN CEMENTS.
The Journal of Korean Academy of Prosthodontics 1998;36(6):888-899
In-Ceram system is one of contemporary esthetic all ceramic restorations and has relatively high flexural strength. The purpose of this study was to evaluate the marginal fidelity according to type of resin cement and measuring position, and to evaluate fracture strength according to type of resin cement. In this study, twenty seven In-Ceram crowns were fabricated on the metal master die of prepared maxillary right central incisor and devided into three groups. All specimens were cemented with Panavia 21 (group PV), Super-bond (group SB) and Lute-it (group LI) on the metal master die. After cementation, specimens were measured marginal gap between the margin of the In-Ceram crown and the finishing line of metal master die by using a stereomicroscope (SZ-ST, Olympus, Japan). Marginal gaps were recorded at the labial, lingual, mesial and distal measuring points on the metal master die. For the mesurement of fracture strength, lingual surfaces of cemented specimens were loaded at a distance of 1mm from incisal edge by using the Autograph S-2000 (Shimadzu, Japan). The results of marginal fidelity and fracture strength were statistically analyzed with the SPSS version 8.0 programs. The results of this study were as follows: 1. In comparison of marginal fidelity according to the measuring points, there was no significant difference. 2. The marginal fidelity according to the type of resin cement was decreased in order of group LI (63.75micrometer), SB (77.78micrometer), PV (86.53micrometer), and there was significant difference between group LI and PV (p<0.05). 3. The fracture strength according to the type of resin cement was showed descending order of group LI (60.00kg/cm2), SB (56.80kg/cm2), PV (56.11kg/cm2), but there was no significant difference.
Cementation
;
Ceramics
;
Crowns*
;
Incisor
;
Resin Cements*
7.A Study On The Tensile Strength Between Metal Denture Base And Relining Materials.
Joon Seok LEE ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(1):1-11
Relining and rebasing are essential for long-term success and oral health in removable prosthodontics. Major features of failures between metal base and relining resins are adhesive failure due to lack of chemical bonding. The purpose of this study was to find a better metal primer and metal surface treatment method that enhance the bonding strength with relining resin materials. The surfaces of ticonium alloys were treated with 25micrometer sandblasting (Group A), stone wheel (Group B), stone wheel and EZ oxisor (Group C), 75micrometer sandblasting (Group D) and EZ oxisor application after 75micrometer sandblasting (Group E). They were subdivided into no primer application (Group I), MR bond application (Group II) and Metafast bonding liner (Group III). Then specimens were completed though being bonded with relining resins. The specimens were stored in 38degrees C water for 48 hours and tensile strength was measured using the universal testing machine. The results were as follows, 1. Primer application groups showed higher bond strength than no primer application group(p<0.05). 2. In comparison with primer application groups, MR bond group showed higher bond strength than Meta fast bonding liner application group(p<0.05). 3. In comparison with surface treatment methods. Bond strengths of group A and B were significantly different with group C, D, and E, and group C were significantly different with group D, and E in no primer application group(p<0.05). In primer application groups, group A, B, C were significantly different with group D and E(p<0.05). According to results of this study, Metal primer application and metal surface roughening were considered to be advantageous for relining of metal base dentures.
Adhesives
;
Alloys
;
Denture Bases*
;
Dentures*
;
Oral Health
;
Prosthodontics
;
Tensile Strength*
;
Water
8.A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY.
Duck Woo RYU ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(2):242-254
Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth' s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin, Futar' occlusion, Blu-mousse) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by X-PLAN360d to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference. 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less mar ginal discrepancy than groups with 0.5mm-marginal-vent-space(p<0.05). In summary, these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.
Humans
;
Jaw Relation Record
;
Prostheses and Implants
;
Tooth*
9.A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY.
Duck Woo RYU ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(2):242-254
Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth' s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin, Futar' occlusion, Blu-mousse) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by X-PLAN360d to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference. 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less mar ginal discrepancy than groups with 0.5mm-marginal-vent-space(p<0.05). In summary, these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.
Humans
;
Jaw Relation Record
;
Prostheses and Implants
;
Tooth*
10.THE ACCURACY ACCORDING TO THE VARIOUS DOWEL PINS OF WORKING CAST WITH REMOVABLE DIES.
The Journal of Korean Academy of Prosthodontics 1997;35(2):373-384
In this study, 4 types of dowel pin were used to fabricate removable dies using the Pindex system. The xomparison of interabutment distances between before and after sawing were conducted in each type of dowel pin, and the horizontal discrepancies in the interabutment distance according to the abutment location and the type of dowel pin were comparatively analyzed. Abutments LM(left molar), LP(left premolar), A(anterior), RP(right premolar), and RM(right molar) were used for measurement. The interabutment distances were measured between each abutment : LM-LP, LM-A, LM-RP, and LM-RM. The slide scanned image of each model was magnified on the computer screen and the measurements were conducted using the meeting point of the cross on the occlusal surface of each abutment. The results were as follows : 1. In the comparison of interabutment distances between before and after sawing in each type of dowel pin, there was no significant difference in World dowel pin(double), Bi-pin(double), Maxcel dowel pin(single). In the World dowel pin(single) there was no significant difference between LM-LPs, but in the other measurements (LM-As, LM-RPs, and LM-RMs) there was significant difference between before and after sawing(p<0.05). 2. In comparison of horizontal discrepancies of the measurement LM-LP(0.27+/-0.19mm)and the others : LM-A(0.46+/-0.20mm), LM-RP(0.38+/-0.25mm), LM-RM(0.45+/-0.22mm)(p<0.05). 3. In comparison of horizontal discrepancies of the measurment according to the type of dowel, there was no significant difference between each dowel. As a result when fabricating a removable die using the previously mentioned 4 types of dowel pins, it is thought that the horizontal discrepancy increased in proportion to the interabutment span length and does not depend on the type of dowel pin.