1.Coexistence of naturally-occuring anti-M in a M positive patient a case report.
Hyun Ok KIM ; Jin Ju KIM ; Oh Hun KWON
Korean Journal of Clinical Pathology 1993;13(1):121-124
No abstract available.
Humans
2.Coexistence of naturally-occuring anti-M in a M positive patient a case report.
Hyun Ok KIM ; Jin Ju KIM ; Oh Hun KWON
Korean Journal of Clinical Pathology 1992;12(1):121-124
No abstract available.
Humans
3.Comparison of three methods for inactivation IgM antibodies for determination of IgG anti-A or anti-B.
Hyun Ok KIM ; Hyon Sok CHO ; Kwang Soo PARK ; Oh Hun KWON ; Jin Ju KIM
Korean Journal of Blood Transfusion 1992;3(2):159-165
No abstract available.
Antibodies*
;
Immunoglobulin G*
;
Immunoglobulin M*
4.Platelet utilization in a university hospital.
Hyun Ok KIM ; Kwang Soo PARK ; Jin Ju KIM ; Oh Hun KWON
Korean Journal of Blood Transfusion 1991;2(2):169-174
No abstract available.
Blood Platelets*
5.A comparative study of three detection methods for antiplatelet antibodies -ELISA, PSIFT, LCT-.
Hyun Ok KIM ; Jin Ju KIM ; Hyon Suk KIM ; Oh Hun KWON ; Samuel Y LEE
Korean Journal of Blood Transfusion 1991;2(1):11-18
No abstract available.
Antibodies*
6.A STUDY ON THE FITNESS OF THE IPS EMPRESS CERAMIC CROWN ACCORDING TO MARGIN TYPE.
Tae Hun JU ; Sang Chun OH ; Jin Keun DONG
The Journal of Korean Academy of Prosthodontics 1998;36(6):846-857
The purpose of this study was to compare the fitness of the IPS Empress ceramic crowns according to margin type such as bevel, shoulder, rounded shoulder, shoulder with bevel, rounded shoulder with bevel and grooved bevel. After 10 experimental dies were constructed for each group, the IPS Empress ceramic crowns were fabricated on the dies, cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. Ltd., Japan) and embeded in clear epoxy resin. Each specimen was sectioned with a low speed diamond saw in both the faciopalatal and the mesiodistal direction. The cement film thickness was measured with a measuring microscope. The obtained results were as follows : 1. The fitness at the external margin was good in the following order: rounded shoulder(28.99), shoulder with bevel(31.33), grooved bevel(31.79), rounded shoulder with bevel(34.65), bevel(35.02) and shoulder(35.08). However there is no significant statistical difference. 2. The fitness at the internal margin of bevel(25.75), rounded shoulder(31.24), shoulder with bevel(32.07) and rounded shoulder with bevel(34.45) was better than that of shoulder(47.98). 3. The fitness at the axial surface of bevel(26.58) was better than that of shoulder(49.59). 4. The fitness at the central fossa was good in the following order: shoulder with bevel(38.88), grooved bevel(40.46) rounded shoulder with shoulder(46.29), shoulder(48.91), bevel(49.47) and rounded bevel(52.07). However there is no significant statistical difference. 5. Overall fitness of bevel(29.71), rounded shoulder(32.49) and shoulder with bevel(34.47) was better than that of shoulder(44.73).
Ceramics*
;
Crowns*
;
Diamond
;
Resin Cements
;
Shoulder
7.Massive transfusion in Severance hospital.
Mi Kyeong LEE ; Hyun Ok KIM ; Seong Geun HONG ; Oh Hun KWON ; Jin Ju KIM
Korean Journal of Blood Transfusion 1993;4(1):23-28
No abstract available.
8.Rupture of the Extensor Pollicis Longus Tendon at the Proximal Screw of Volar Plate Fixation for Distal Radius Fracture: A Case Report.
Dong Ju SHIN ; Seung Oh NAM ; Hun Sik CHO
Journal of the Korean Fracture Society 2013;26(4):338-342
As volar plate fixation of distal radius fracture becomes more common, reports of ruptured extensor pollicis longus tendon by a protruding distal screw tip are also increasing steadily. Authors have experienced a rare case of ruptured extensor pollicis longus tendon at the prominent proximal screw of fixed volar plate for distal radius fracture, and we report it herein with a review of the literature.
Radius Fractures
;
Radius
;
Rupture
;
Tendons
;
Palmar Plate*
9.A STUDY ON THE FRACTURE STRENGTH OF THE IPS-EMPRESS CERAMIC CROWN ACCORDING TO MARGIN TYPE.
Hyun soo KIM ; Tae Hun JU ; Sang Chun OH ; Jin Keun DONG
The Journal of Korean Academy of Prosthodontics 1997;35(2):296-307
The purpose of this study was to compare the fracture strength of the IPS-Empress ceramic crown according to margin types such as bevel, shoulder, ronuded shoulder, schouler with bevel, rounded shoulder with bevel and bevel with groove. After 10 metal dies were constructed for each group, the IPS-Empress ceramic crown were fabricated and each crown was cemented on each metal die with Bistite resin cement. The cemented each crown was cemented on each metal die with Bistirte resin cement. The cemented crowns mounted in the resting jig were inclined 30 degree and universal testing machine (Zwick 1456 41, Zwick Co., Germany) was used to measure the fracture strength. The obtained result were as follows : 1. The fracture strenght of the crown with reounded shoulder was the hightest of all. The mean fracture strength was 484N in rounded shoulder, 357N in bebel, 341N in rounded shoulder with bevel, 300N in shoulder with bevel, 280N in shoulder and 275N in bevel with groove. 2. The fracture strength of rounded shoulder was statistcally different from those of shoulder with bevel, shoulder and bevel with groove. 3. In the strain at fracture, there was no significant difference among each group. 4. The fracture mode of the crown was simila and most of fracture line began at the loading area and extended throught proximal surface perpendicularly to the margin, irrespective of margin type.
Ceramics*
;
Crowns*
;
Resin Cements
;
Shoulder
10.Genetic Abnormality and Localization of Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) in Patients with Nasal Polyps.
Yong Ju JANG ; Chung Hun OH ; Chul Hee LEE
Journal of Rhinology 2000;7(1):22-27
BACKGROUND AND OBJECTIVES: Cystic fibrosis transmembrane conductance regulator (CFTR) is a chloride channel protein, its kinetics and localization are altered in cystic fibrosis. The purpose of this study was to evaluate whether the nasal polyp patients without phenotypic manifestation of cystic fibrosis have any form of CFTR mutations and to characterize the localization of CFTR in the nasal polyp. MATERIALS AND METHODS: The study group consisted of 71 subjects with nasal polyp who underwent an intranasal operation, and 20 normal subjects. Peripheral blood of the study groups were screened for mutation on the exon 3, 4, and 7 of the CFTR gene using single-stranded DNA conformational polymorphism (SSCP). Immunohistochemical staining for CFTR was conducted on the nasal polyps of studied subjects and normal turbinates as the control. RESULTS: While in the nasal polyp group, SSCP screening revealed two cases of mutant band on the exon 3, the normal control group did not show mutant band in all exons screened. CFTR showed the typical apical distribution in the normal turbinate mucosa, whereas in the nasal polyp, regardless of an abnormal band in exon 3, CFTR demonstrated a heterogenous pattern of localization consisting of cytoplasmic labeling, perinuclear staining, and intermingled apical location. CONCLUSION: These results suggest that an altered localization of the CFTR in the nasal polyps, based not only on the CFTR mutation but also on the acquired inflammatory process, may have an important role in the formation of nasal polyps.
Chloride Channels
;
Cystic Fibrosis Transmembrane Conductance Regulator*
;
Cystic Fibrosis*
;
Cytoplasm
;
DNA, Single-Stranded
;
Exons
;
Humans
;
Immunohistochemistry
;
Kinetics
;
Mass Screening
;
Mucous Membrane
;
Nasal Polyps*
;
Polymorphism, Single-Stranded Conformational
;
Turbinates