1.A case of gastric teratoma.
Young Sup SHIN ; Hwa Ju KIM ; Sang Kyu PARK ; Ho Jin PARK ; Chang Hyun LEE ; Joung Ha SON ; Mi Kyung SHIN
Journal of the Korean Pediatric Society 1991;34(9):1311-1315
No abstract available.
Teratoma*
2.Standard Performance Measurements of GE AdvanceTM Positron Emission Tomography.
Ha Kyu JEONG ; Hee Joung KIM ; Hye Kyung SON ; Jung Kyun BONG ; Hai Jo JUNG ; Tae Joo JEON ; Jae Sam KIM ; Jong Doo LEE ; Hyung Sik YOO
Korean Journal of Nuclear Medicine 2001;35(2):100-112
PURPOSE: The purpose of this study was to establish optimal imaging acquisition conditions for the GE Advance(TM) PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. MATERIALS AND METHODS: Performance tests were carried out with 18FDG radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter fraction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. RESULTS: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was 225.8 kcps/micronCi/cc of trues. Activity at 50% deadtime was 4.6 Ci/cc, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice was 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). CONCLUSION: The results satisfied most acceptance criteria, indicating that the GE AdvanceTM PET system can be optimally used for clinical applications.
Electrons*
;
Fluorodeoxyglucose F18
;
Polymethyl Methacrylate
;
Polytetrafluoroethylene
;
Positron-Emission Tomography*
;
Radioactivity
;
Water
3.Analysis of gallstones which cause biliary symptoms or complication.
Sung Hee PYO ; Eun Kwang CHOI ; Myung Hwan KIM ; Dong Wan SOE ; Sung Koo LEE ; Sang Soo LEE ; Kyu Pyo KIM ; Ji Min HAN ; Hyun Young SON ; Jin Uk JOUNG ; Jong Ha PAK ; Tae Jun SONG ; Se Hwan LEE ; Young Il MIN
Korean Journal of Medicine 2003;65(4):412-421
BACKGROUND: Gallstone is one of the most common cause of acute abdominal pain and is increasingly managed by laparoscopic cholecystectomy. Silent gallstones are usually managed expectantly and are considered for surgery only if the characteristic biliary pain occurs. If predictors of stone-related complications such as acute cholecystitis, pancreatitis, and cholangitis can be identified, patients at high risk can be selectively referred for treatment regardless of symptoms development, while those at lower risk may be safely observed. The purpose of this study was to find out the predictors of stone-related complication or biliary pain in patients with gallbladder stones. METHODS: We collected clinical data retrospectively on patients who were diagnosed with gallstone at Asan Medical Center. Total gallstone number was classified into 1, 2~4, over 5. Diameter of the gallstones were subdivided into
Abdominal Pain
;
Cholangiopancreatography, Endoscopic Retrograde
;
Cholangitis
;
Cholecystectomy
;
Cholecystectomy, Laparoscopic
;
Cholecystitis
;
Cholecystitis, Acute
;
Chungcheongnam-do
;
Female
;
Gallbladder
;
Gallstones*
;
Humans
;
Logistic Models
;
Male
;
Pancreatitis
;
Retrospective Studies
;
Risk Factors