1.Can a Point-of-Care Troponin I Assay be as Good as a Central Laboratory Assay? A MIDAS Investigation.
W Frank PEACOCK ; Deborah DIERCKS ; Robert BIRKHAHN ; Adam J SINGER ; Judd E HOLLANDER ; Richard NOWAK ; Basmah SAFDAR ; Chadwick D MILLER ; Mary PEBERDY ; Francis COUNSELMAN ; Abhinav CHANDRA ; Joshua KOSOWSKY ; James NEUENSCHWANDER ; Jon SCHROCK ; Elizabeth LEE-LEWANDROWSKI ; William ARNOLD ; John NAGURNEY
Annals of Laboratory Medicine 2016;36(5):405-412
BACKGROUND: We aimed to compare the diagnostic accuracy of the Alere Triage Cardio3 Tropinin I (TnI) assay (Alere, Inc., USA) and the PathFast cTnI-II (Mitsubishi Chemical Medience Corporation, Japan) against the central laboratory assay Singulex Erenna TnI assay (Singulex, USA). METHODS: Using the Markers in the Diagnosis of Acute Coronary Syndromes (MIDAS) study population, we evaluated the ability of three different assays to identify patients with acute myocardial infarction (AMI). The MIDAS dataset, described elsewhere, is a prospective multicenter dataset of emergency department (ED) patients with suspected acute coronary syndrome (ACS) and a planned objective myocardial perfusion evaluation. Myocardial infarction (MI) was diagnosed by central adjudication. RESULTS: The C-statistic with 95% confidence intervals (CI) for diagnosing MI by using a common population (n=241) was 0.95 (0.91-0.99), 0.95 (0.91-0.99), and 0.93 (0.89-0.97) for the Triage, Singulex, and PathFast assays, respectively. Of samples with detectable troponin, the absolute values had high Pearson (R(P)) and Spearman (R(S)) correlations and were R(P)=0.94 and R(S)=0.94 for Triage vs Singulex, R(P)=0.93 and R(S)=0.85 for Triage vs PathFast, and R(P)=0.89 and R(S)=0.73 for PathFast vs Singulex. CONCLUSIONS: In a single comparative population of ED patients with suspected ACS, the Triage Cardio3 TnI, PathFast, and Singulex TnI assays provided similar diagnostic performance for MI.
Acute Coronary Syndrome/*diagnosis
;
Biomarkers/analysis
;
Emergency Service, Hospital
;
Humans
;
Laboratories/standards
;
Myocardial Infarction/diagnosis
;
*Point-of-Care Systems
;
Prospective Studies
;
Reagent Kits, Diagnostic
;
Sensitivity and Specificity
;
Troponin I/*analysis
2.Finding acute coronary syndrome with serial troponin testing for rapid assessment of cardiac ischemic symptoms (FAST-TRAC): a study protocol
W. Frank PEACOCK ; Alan S. MAISEL ; Christian MUELLER ; Stefan D. ANKER ; Fred S. APPLE ; Robert H. CHRISTENSON ; Paul COLLINSON ; Lori B. DANIELS ; Deborah B. DIERCKS ; Salvatore Di SOMMA ; Gerasimos FILIPPATOS ; Gary HEADDEN ; Brian HIESTAND ; Judd E. HOLLANDER ; Juan C. KASKI ; Joshua M. KOSOWSKY ; John T. NAGURNEY ; Richard M. NOWAK ; Donald SCHREIBER ; Gary M. VILKE ; Marvin A. WAYNE ; Martin THAN
Clinical and Experimental Emergency Medicine 2022;9(2):140-145
Objective:
To determine the utility of a highly sensitive troponin assay when utilized in the emergency department.
Methods
The FAST-TRAC study prospectively enrolled >1,500 emergency department patients with suspected acute coronary syndrome within 6 hours of symptom onset and 2 hours of emergency department presentation. It has several unique features that are not found in the majority of studies evaluating troponin. These include a very early presenting population in whom prospective data collection of risk score parameters and the physician’s clinical impression of the probability of acute coronary syndrome before any troponin data were available. Furthermore, two gold standard diagnostic definitions were determined by a pair of cardiologists reviewing two separate data sets; one that included all local troponin testing results and a second that excluded troponin testing so that diagnosis was based solely on clinical grounds. By this method, a statistically valid head-to-head comparison of contemporary and high sensitivity troponin testing is obtainable. Finally, because of a significant delay in sample processing, a unique ability to define the molecular stability of various troponin assays is possible.Trial registration ClinicalTrials.gov Identifier NCT00880802