1.Assessment of therapeutic clinical trials for proximal humeral fractures
Jonathan KOA ; Mohamad Y. FARES ; Mohammad DAHER ; Joseph A. ABBOUD
Clinics in Shoulder and Elbow 2024;27(2):237-246
Proximal humeral fractures (PHFs) are a common injury among the older population. An ideal therapeutic protocol has yet to be developed, and numerous clinical trials are being conducted to find the best therapeutic approach. The purpose of this study is to evaluate the current body of knowledge available via interventional clinical trials. In December 2022, interventional clinical trials relating to PHFs on Clinicaltrials.gov were screened. Trial characteristics included duration, status, intervention, phase, outcomes, location, and study design. Publications associated with each trial were searched on PubMed/Medline using the ClinicalTrials.gov registry number. The final dataset comprised 64 trials. The most common trial status was completed (36%). The majority did not have a Food and Drug Administration-defined phase (67%), was randomized (81%), involved a single facility (72%), used a parallel assignment intervention model (80%), and used an open-label approach (45%). Eleven trials were associated with a publication, and the publication rate was 17%. Average enrollment was 86 participants, and mean trial duration was 51.4 months. Europe/UK/Russia/Turkey participated in the most trials (70%). Most of the trials were initiated after 2010 (87.5%). Procedure-related interventions (55%) were most common. Disability/function was the most common primary outcome assessed (61%). The low publication rate and the multitude of trials conducted after 2010 highlight the urgency and need for trial results to be published to establish an ideal therapeutic protocol. Since the majority of the trials involved a single institution and an open-label approach, reinforcing blinding and establishing multi-centered trials can improve the validity of the clinical trial results.
2.InSpace Balloon for the Management of Massive Irreparable Rotator Cuff Tears:A Systematic Review and Meta-Analysis
Mohammad DAHER ; Adam PEARL ; Ziad ZALAQUETT ; Bassem T. ELHASSAN ; Joseph A. ABBOUD ; Mohamad Y. FARES ; Khaled J. SALEH
Clinics in Orthopedic Surgery 2023;15(5):834-842
Background:
The best course of action for massive irreparable rotator cuff tears (MIRCTs) is not universally agreed upon. Numerous surgical techniques have been discussed. The implantation of a biodegradable spacer into the subacromial area has been documented since 2012 by several authors. The implantation method is touted as being simpler, repeatable, and less invasive than other solutions that are now available. The purpose of this systematic review and meta-analysis, being the first of its kind, was to evaluate the literature to see the efficacy of InSpace balloon (ISB) implantation in the management of MIRCTs.
Methods:
Following Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines, and with 2 researchers assessing and analyzing each study separately, an extensive electronic search of the literature was conducted in the PubMed database from 1961 until July 27, 2022.
Results:
Fourteen studies were included in this systematic review and three in the meta-analysis. Eleven out of fourteen studies favored ISB use for MIRCTs, while only three were against its use. All spacers were arthroscopically implanted in the subacromial space. Three studies were included in the meta-analysis. The differences in the compared outcomes were statistically insignificant.
Conclusions
A controversy about the use of ISB remains in patients with MIRCTs. Both good and bad outcomes were reported.However, the majority of patients had good clinical outcomes across several grading scales, radiographic evidence of improved impingement, and self-report that they would redo the procedure in hindsight. To draw more solid conclusions and have statistically significant results in the meta-analysis, more randomized controlled trials and comparative studies comparing this device to other treatments are needed.
3.Anterior Shoulder Instability and Open Procedures:History, Indications, and Clinical Outcomes
Mohamad Y. FARES ; Peter BOUFADEL ; Mohammad DAHER ; Jonathan KOA ; Akshay KHANNA ; Joseph A. ABBOUD
Clinics in Orthopedic Surgery 2023;15(4):521-533
The shoulder, being the most mobile joint in the human body, is often susceptible to dislocations and subluxations more so than other joints. As such, shoulder instability constitutes a common complaint among patients worldwide, especially those who are young, participate in contact sports, and have increased innate flexibility in their joints. Management options in the setting of instability vary between conservative and surgical options that aim to mitigate symptoms and allow return of function. Surgical options can be arthroscopic and open, with a general shift among surgeons towards utilizing arthroscopic surgery in the past several decades. Nevertheless, open procedures still play a role in managing shoulder instability patients, especially those with significant bone loss, recurrent instability, coexisting shoulder pathologies, and high risk of failure with arthroscopic surgery. In these clinical settings, open procedures, like the Latarjet procedure, open Bankart repair, glenoid bone augmentation using iliac crest autograft or distal tibial allograft, and salvage options like glenohumeral arthrodesis and arthroplasty may show good clinical outcomes and low recurrence rates. Each of these open procedures possesses its own set of advantages and disadvantages and entails a specific set of indications based on published literature. It is important to cater treatment options to the individual patient in order to optimize outcomes and reduce the risk of complications. Future research on open shoulder stabilization procedures should focus on the long-term outcomes of recently utilized procedures, investigate different graft options for procedures involving bone augmentation, and conduct additional comparative analyses in order to establish concrete surgical management guidelines.
4.Evaluation of online video content related to reverse shoulder arthroplasty: a YouTube-based study
Mohamad Y. FARES ; Jonathan KOA ; Peter BOUFADEL ; Jaspal SINGH ; Amar S. VADHERA ; Joseph A. ABBOUD
Clinics in Shoulder and Elbow 2023;26(2):162-168
Reverse shoulder arthroplasty (RSA) has evolved continuously over recent years, with expanded indications and better outcomes. YouTube is one of the most popular sources globally for health-related information available to patients. Evaluating the reliability of YouTube videos concerning RSA is important to ensure proper patient education. Methods: YouTube was queried for the term “reverse shoulder replacement.” The first 50 videos were evaluated using three different scores: Journal of the American Medical Association (JAMA) benchmark criteria, the global quality score (GQS), and the reverse shoulder arthroplasty-specific score (RSAS). Multivariate linear regression analyses were conducted to determine the presence of a relationship between video characteristics and quality scores. Results: The average number of views was 64,645.78±264,160.9 per video, and the average number of likes was 414 per video. Mean JAMA, GQS, and RSAS scores were 2.32±0.64, 2.31±0.82, and 5.53±2.43, respectively. Academic centers uploaded the highest number of videos, and surgical techniques/approach videos was the most common video content. Videos with lecture content predicted higher JAMA scores whereas videos uploaded by industry predicted lower RSAS scores. Conclusions: Despite its massive popularity, YouTube videos provide a low quality of information on RSA. Introducing a new editorial review process or developing a new platform for patients’ medical education may be necessary. Level of evidence: Not applicable.
5.Online resources for information on shoulder arthroplasty: an assessment of quality and readability
Mohamad Y. FARES ; Jaspal SINGH ; Amar S. VADHERA ; Jonathan KOA ; Peter BOUFADEL ; Joseph A. ABBOUD
Clinics in Shoulder and Elbow 2023;26(3):238-244
Background:
Many patients use online resources to educate themselves on surgical procedures and make well-informed healthcare decisions. The aim of our study was to evaluate the quality and readability of online resources exploring shoulder arthroplasty.
Methods:
An internet search pertaining to shoulder arthroplasty (partial, anatomic, and reverse) was conducted using the three most popular online search engines. The top 25 results generated from each term in each search engine were included. Webpages were excluded if they were duplicates, advertised by search engines, subpages of other pages, required payments or subscription, or were irrelevant to our scope. Webpages were classified into different source categories. Quality of information was assessed by HONcode certification, Journal of the American Medical Association (JAMA) criteria, and DISCERN benchmark criteria. Webpage readability was assessed using the Flesch reading ease score (FRES).
Results:
Our final dataset included 125 web pages. Academic sources were the most common with 45 web pages (36.0%) followed by physician/private practice with 39 web pages (31.2%). The mean JAMA and DISCERN scores for all web pages were 1.96±1.31 and 51.4±10.7, respectively. The total mean FRES score was 44.0±11.0. Only nine web pages (7.2%) were HONcode certified. Websites specified for healthcare professionals had the highest JAMA and DISCERN scores with means of 2.92±0.90 and 57.96±8.91, respectively (P<0.001). HONcode-certified webpages had higher quality and readability scores than other web pages.
Conclusions
Web-based patient resources for shoulder arthroplasty information did not show high-quality scores and easy readability. When presenting medical information, sources should maintain a balance between readability and quality and should seek HONcode certification as it helps establish the reliability and accessibility of the presented information.Level of evidence: IV.
6.The 100 Most Impactful Articles on Total Shoulder Arthroplasty: An Altmetric Analysis
Mohamad Y. FARES ; Amar S. VADHERA ; Mohammad DAHER ; Peter BOUFADEL ; Jonathan KOA ; Jaspal SINGH ; Joseph A. ABBOUD
Clinics in Orthopedic Surgery 2024;16(3):441-447
Background:
To use the top 100 articles pertaining to total shoulder arthroplasty (TSA) to understand the impact that social media platforms have on the dissemination of shoulder research while highlighting bibliometric factors associated with Altmetric Attention Score (AAS) to offer insight into the impact that social media platforms have on the dissemination, attention, and citation of shoulder research publications.
Methods:
In June 2023, the Altmetric database was searched using the following PubMed MeSH terms: “total shoulder arthroplasty” or “TSA.” Articles with the highest AAS were screened to exclude other topics unrelated to TSA. The top 100 articles that met inclusion criteria were used in the final analysis. Bibliometric factors pertaining to each study were collected for further analysis of article characteristics in accordance with prior studies.
Results:
The Altmetric Database query yielded 1,283 studies. After applying our inclusion criteria, the top 118 articles with the highest AAS were identified. The mean AAS was 29.14 ± 42.35, with a range of 13 to 402. The included articles represented 27 journals, with 70 articles attributed to 2 journals: Journal of Shoulder and Elbow Surgery (JSES; 43%) and the Journal of Bone and Joint Surgery (JBJS; 16%). There was a significant increase in AAS for the presence of a conflict of interest (p = 0.042) and open access status (p < 0.01), but no association between the score and citation rate (p> 0.05).
Conclusions
Top articles on TSA, as defined by high AAS, mostly comprise original clinical research performed in the United States or Europe. The presence of a conflict of interest and open access status is associated with an increase in AAS, but there was no association between AAS score and citation rate.
7.Bilateral reverse shoulder arthroplasty versus bilateral anatomic shoulder arthroplasty: a meta-analysis and systematic review
Mohammad DAHER ; Mohamad Y. FARES ; Jonathan KOA ; Jaspal SINGH ; Joseph ABBOUD
Clinics in Shoulder and Elbow 2024;27(2):196-202
Background:
As the population is aging and indications are expanding, shoulder arthroplasty is becoming more frequent, especially bilateral staged replacement. However, surgeons are hesitant to use bilateral reverse prostheses due to potential limitations on activities of daily living.
Methods:
This meta-analysis was conducted to compare bilateral anatomic to bilateral reverse shoulder implants. PubMed, Cochrane, and Google Scholar (pages 1–20) were searched until April 2023. The clinical outcomes consisted of postoperative functional scores (American Shoulder and Elbow Surgeons [ASES], Single Assessment Numeric Evaluation [SANE], Physical Component Score [PCS], Mental Component Score, and Simple Shoulder Test), pain, and range of motion (external rotation and forward elevation). Three studies were included in this meta-analysis.
Results:
Bilateral anatomic implants had better postoperative functional outcomes and range of motion, but no significant difference was seen in postoperative pain when compared to the reverse prosthesis. Better ASES score, SANE score, and PCS as well as better external rotation and forward elevation were seen in the bilateral anatomic shoulder replacement group, but no significant difference in pain levels was seen between the two groups.
Conclusions
The results may be explained by the lower baseline seen in the reverse prosthesis group, which may be due to an older population and different indications. Nevertheless, more randomized controlled studies are needed to confirm these findings.Level of evidence: III.
8.Arthroscopic remplissage: history, indications, and clinical outcomes
Mohamad Y. FARES ; Mohammad DAHER ; Peter BOUFADEL ; Emil R. HAIKAL ; Jonathan KOA ; Jaspal SINGH ; Joseph A. ABBOUD
Clinics in Shoulder and Elbow 2024;27(2):254-262
Several surgical procedures have been proposed to address anterior glenohumeral instability, which is one of the most common complaints in the general population. The remplissage, first described in early 2000s, is a procedure performed simultaneously with the arthroscopic Bankart repair to correct large, engaging Hill-Sachs lesions (HSLs). This procedure stabilizes the joint by tenodesing the infraspinatus tendon into the HSL to fill and disengage the defect. This procedure gained popularity because it has relatively low risk and is able to improve shoulder stability while being less invasive than other bone-blocking procedures. The remplissage has become a valuable add-on technique that can substantially improve outcomes in unstable patients undergoing arthroscopic Bankart repair. Nevertheless, several studies in the literature have raised concerns regarding its efficacy in critically unstable patients and the potential range of motion limitations that can arise postoperatively. Additional comparative studies and trials should be conducted to appropriately establish the role of remplissage in treating anterior instability, especially in patients with critical bone loss.
9.Pyrocarbon hemiarthroplasty and the shoulder: biomechanical and clinical results of an emerging treatment option
Mohamad Y. FARES ; Jaspal SINGH ; Peter BOUFADEL ; Matthew R. COHN ; Joseph A. ABBOUD
Clinics in Shoulder and Elbow 2024;27(1):117-125
While shoulder hemiarthroplasty is still used to treat young patients with shoulder pathology, the use of this procedure has substantially declined in recent years due to its significant complication profile. Glenoid wear with arthrosis is one of the major postoperative complications following shoulder hemiarthroplasty, and efforts to prevent this complication led many scientists to explore alternative weight-bearing surfaces on arthroplasty implants to decrease joint wear and improve patient outcomes. Pyrolytic carbon, or pyrocarbon, is a material that has better biocompatibility, survivorship, strength, and wear resistance compared to the materials used in traditional shoulder hemiarthroplasty. Pyrocarbon implants have been used in orthopedics for over 50 years; recently, their utility in shoulder hemiarthroplasty has garnered much interest. The purpose behind the use of pyrocarbon in shoulder hemiarthroplasty is to decrease the risk of progressive glenoid wear, especially in young active patients in whom joint preservation is important. Promising survivorship and outcomes have been demonstrated by recent studies, including limited glenoid wear following pyrocarbon hemiarthroplasty. Nevertheless, these clinical studies have been limited to relatively small case series with limited long-term follow-up. Accordingly, additional research and comparative studies need to be conducted in order to properly assess the therapeutic efficacy and value of pyrocarbon hemiarthroplasty.
10.Patient-specific implants in reverse shoulder arthroplasty
Emil R HAIKAL ; Mohamad Y. FARES ; Joseph A. ABBOUD
Clinics in Shoulder and Elbow 2024;27(1):108-116
Reverse total shoulder arthroplasty (RTSA) is widely popular among shoulder surgeons and patients, and its prevalence has increased dramatically in recent years. With this increased use, the indicated pathologies associated with RTSA are more likely to be encountered, and challenging patient presentations are more likely to be seen. One prominent challenging presentation is RTSA patients with severe glenoid bone loss. Several techniques with varying degrees of invasiveness, including excessive reaming, alternate centerline, bone grafting, and patient-specific implants (PSIs), have been developed to treat patients with this presentation. PSI treatment uses a three-dimensional reconstruction of a computed tomography scan to design a prosthetic implant or component customized to the patient’s glenoid morphology, allowing compensation for any significant bone loss. The novelty of this technology implies a paucity of available literature, and although many studies show that PSIs have good potential for solving challenging shoulder problems, some studies have reported questionable and equivocal outcomes. Additional research is needed to explore the indications, outcomes, techniques, and cost-efficiency of this technology to help establish its role in current treatment guidelines and strategies.