2.Diagnosis of Smith-Magenis Syndrome in a Patient with Mental Retardation and Sleep Disturbance Confirmed by Multiplex Ligation-dependent Probe Amplification.
Joowon OH ; Seungjae LEE ; Kyung A LEE ; Jongha YOO
Laboratory Medicine Online 2018;8(2):71-74
No abstract available.
Diagnosis*
;
Humans
;
Intellectual Disability*
;
Multiplex Polymerase Chain Reaction*
;
Smith-Magenis Syndrome*
3.Diagnostic Challenge: Primary Bone Marrow Diffuse Large B-cell Lymphoma Mimicking Systemic Autoimmune Diseases
Joowon OH ; Yoonjung KIM ; Seung Tae LEE ; Kyung A LEE
Laboratory Medicine Online 2019;9(4):242-245
No abstract available.
Autoimmune Diseases
;
B-Lymphocytes
;
Bone Marrow
;
Lymphoma, B-Cell
5.Performance Evaluation of Body Fluid Cellular Analysis Using the Beckman Coulter UniCel DxH 800, Sysmex XN-350, and UF-5000 Automated Cellular Analyzers
Jooyoung CHO ; Joowon OH ; Sang Guk LEE ; You Hee LEE ; Jaewoo SONG ; Jeong Ho KIM
Annals of Laboratory Medicine 2020;40(2):122-130
BACKGROUND:
Automated cellular analyzers are expected to improve the analytical performance in body fluid (BF) analysis. We evaluated the analytical performance of three automated cellular analyzers and established optimum reflex analysis guidelines.
METHODS:
A total of 542 BF samples (88 cerebrospinal fluid [CSF] samples and 454 non-CSF samples) were examined using manual counting and three automated cellular analyzers: UniCel DxH 800 (Beckman Coulter), XN-350 (Sysmex), and UF-5000 (Sysmex). Additionally, 2,779 BF analysis results were retrospectively reviewed. For malignant cell analysis, the receiver operating characteristic (ROC) curve was used, and the detection of high fluorescence-BF cells (HF-BFs) using the XN-350 analyzer was compared with cytology results.
RESULTS:
All three analyzers showed good agreement for total nucleated cell (TNC) and red blood cell (RBC) counts, except for the RBC count in CSF samples using the UniCel DxH 800. However, variable degrees of differences were observed during differential cell counting. For malignant cell analysis, the area under the curve was 0.63 for the XN-350 analyzer and 0.76 for manual counting. We established our own reflex analysis guidelines as follows: HF-BFs <0.7/100 white blood cells (WBCs) is the criterion for quick scans with 100× magnification microscopic examination as a rule-out cut-off, while HF-BFs >83.4/100 WBCs or eosinophils >3.8% are the criteria for mandatory double check confirmation with 1,000× magnification examination.
CONCLUSIONS
The three automated analyzers showed good analytical performances. Application of reflex analysis guidelines is recommended for eosinophils and HF-BFs, and manual confirmation is warranted.
6.Effects of Cold Agglutinin on the Accuracy of Complete Blood Count Results and Optimal Sample Pretreatment Protocols for Eliminating Such Effects.
John Hoon RIM ; Myung Hee CHANG ; Joowon OH ; Heon Yung GEE ; Jeong Ho KIM ; Jongha YOO
Annals of Laboratory Medicine 2018;38(4):371-374
No abstract available.
Blood Cell Count*
7.Guideline for Minimizing Radiation Exposure of Interventionalists during Fluoroscopy-Guided Interventional Procedures
Il Sang SHIN ; Yun Nah LEE ; Jun Kyu LEE ; Joo Seong KIM ; Sung Bum KIM ; Jiyoung KEUM ; Chang Hoon OH ; Kang Won LEE ; Joowon CHUNG ; Lyo Min KWON ; Nam Hee KIM ; Sang Soo LEE ; Byoung Kwan SON ; Miyoung CHOI
Korean Journal of Pancreas and Biliary Tract 2024;29(3):69-84
As fluoroscopy-guided interventional procedures gain popularity, the associated health threats from radiation exposure to interventionalists during these procedures are increasing. Therefore, an understanding of the potential risks of radiation and careful consideration on minimizing exposure to radiation during the procedures are of paramount importance. The Korean Pancreatobiliary Association has developed a clinical practice guideline to minimize radiation exposure during fluoroscopy-guided interventional procedures. This guideline provides recommendations to deal with the risk of radiation exposure to interventionalists who perform fluoroscopy-guided procedures, and emphasizes the importance of proper and practical approaches to avoid unnecessary radiation exposure.