1.Intraosseous Ganglion of Femoral Head: A Case Report.
Gun Il IM ; Joo Ho SHIN ; Min Ug KWON
The Journal of the Korean Orthopaedic Association 1998;33(3):637-640
Intraosseous ganglion is an uncommon benign tumor thought to be caused by an intramedullary metaplastic event. We recently experienced a case of intraosseous ganglion that occurred on the femoral head of a 65-year old man who complained of intermittent hip pain. Complete evaluation including bone scan, CT, MRI was done. His pain disappeared after curettage and bone graft was done on the lesion.
Aged
;
Bone Cysts*
;
Curettage
;
Head*
;
Hip
;
Humans
;
Magnetic Resonance Imaging
;
Transplants
2.A case of pseudoaneurysm of the sphenopalatine artery followingpanfacial bone fracture.
Hyung Joo KIM ; Min Ho SHIN ; Byung Do SUH
Korean Journal of Otolaryngology - Head and Neck Surgery 1992;35(6):930-935
No abstract available.
Aneurysm, False*
;
Arteries*
;
Fractures, Bone*
3.Surgical Treatment of the Closed Complete Rupture of Achilles Tendon.
Joo Chul IHN ; Byung Chul PARK ; Hee Soo KYUNG ; Shin Yoon KIM ; Seung Ho SHIN
The Journal of the Korean Orthopaedic Association 1997;32(7):1681-1686
Achilles tendon is the most powerful and the biggest tendon of the body and its rupture is frequently sports-related. Many authors reported the effects of mobilization, electricity, ultrasound and various drugs as factors influencing the injured tendon. We studied the effects of early passive mobilization after firm suture using plantaris tendon as tension suture material and reinforcing membrane on the repair of a ruptured Achilles tendon. From March 1992 to December 1995, twenty-two operations on the Achilles tendon were carried out in our hospital. 1. Fourteen patients were male and eight patients were female. The mean patient age was 38 years, ranging from 13 to 68 years. Average follow-up periods was 2 years and 7 months, ranging from 12 months to 3 years and 8 months. 2. The rupture site was 4.7cm proximal to the tendon insertion into the calcaneus on average. 3. We performed the operations with end to end suture technique. After approximation of the ruptured ends of the tendon with a No. 5 Ethibond tension suture using a modified Kessler stitch, placed plantaris tendon in a fascial needle and pass it circumferentially and distal plantaris tendon is fanned out and tacked over the repair. 4. Postoperative treatment was done as following protocol Short leg cast was done with equinus position for initial 3 weeks, and then cast was removed, hydrotherapy and passive exercises was employed. About 6 weeks after operation when the foot can be brought to right angle, a reverse 90degrees ankle stop short leg brace was applied for additional 6 weeks and partial weight bearing was aUowed. 5. Follow-up results were classified according to the Arner-Lindholm scale. We had 16 excellent results and 6 satisfactory results. After rigid suture it may be possible to introduce a regimen of progressive isometric stimulation and protected loading and streching combined with removable orthosis. Such early exercises are likely to improve the rate of rehabilitation over plaster immobilization.
Achilles Tendon*
;
Ankle
;
Braces
;
Calcaneus
;
Electricity
;
Exercise
;
Female
;
Follow-Up Studies
;
Foot
;
Humans
;
Hydrotherapy
;
Immobilization
;
Leg
;
Male
;
Membranes
;
Needles
;
Orthotic Devices
;
Rehabilitation
;
Rupture*
;
Suture Techniques
;
Sutures
;
Tendons
;
Ultrasonography
;
Weight-Bearing
4.Clinical Characteristics of Pulmonary Aspergillosis.
Ik Soo PARK ; Ho Joo YOON ; Dong Ho SHIN ; Sung Soo PARK ; Jung Hee LEE
Tuberculosis and Respiratory Diseases 1994;41(6):624-631
BACKGROUND: Genus of Aspergilli are ubiquitous saprophytic molds in nature, but its change from a saprophytic fungus to a pathogenic organism has occurred since the use of various antibiotics. The fungus affects the chronically ill and debilitated population. Recently frequency of the fungal infection is increasing in Korea with abuse of antibiotics and glucocorticoids. METHOD: We analyzed medical records of 52 patients with pulmonary aspergillosis seen at Hanyang University Hospital from 1980 to 1994. The results were as follows; RESULTS: 1) Ages ranged between second to eighth decades with majority(50%) in the fourth to fifth decades. The male to female ratio was 1.1:1. 2) Hemoptysis and productive cough, the leading symptoms, occurred in 42.3% and 25% respectively. 3) On chest X-ray fingings, the characteristic 'fungus ball' pattern were observed in 53.8% of the 52 cases. 4) Sputum culture for aspergilli were positive in 21.6% of the cases. We performed foe needle aspiration in 22 patients and the diagnostic yield was 100%. 5) Thirty-six patients had history of treatment with antituberculous drugs under diagnosis of pulmonary tuberculosis for an average of 27.3 months. But sputum analysis for acid-fast bacilli were positive in 5.6%(2cases of 36cases), and postoperative pathologic findings showed that 38.9% (12 cases of 28cases) were combined with tuberculosis. 6) Right upper and left upper lobes were predominantly involved(34.6% and 19.2% respectively) and lobectomies were performed in 21 cases. 7) Underlying diseases were present in 47 cases and 48.9% of them were pulmonary tuberculosis. CONCLUSION: These results showed that pulmonary aspergillosis usually develops in patients with open cavitary pulmonary tuberculosis. And we must consider the possibility of pulmonary aspergillosis in a patient with hemoptysis and cavitary lung lesion.
Anti-Bacterial Agents
;
Aspergillus
;
Chronic Disease
;
Cough
;
Diagnosis
;
Female
;
Fungi
;
Glucocorticoids
;
Hemoptysis
;
Humans
;
Korea
;
Lung
;
Male
;
Medical Records
;
Needles
;
Pulmonary Aspergillosis*
;
Sputum
;
Thorax
;
Tuberculosis
;
Tuberculosis, Pulmonary
5.Changes of rotator Cuff using Ultrasonography in Frozen Shoulder
Chang Ju LEE ; Won Ho CHO ; Sung Kee CHANG ; In sung LEE ; Joo Ho SHIN
The Journal of the Korean Orthopaedic Association 1989;24(1):156-160
Although several histopathological changes have been developed in frozen shoulder, frozen shoulder is mostly accompanied by the changes of the rotator cuff which has the most important function in movement and has a role in stabilizing the shoulder joint. The changes of the rotator cuff in frozen shoulder have not been reported in Korea yet, but Simon reported that there was an attenuation of the rotator cuff in frozn shoulder. Accordingly, we observed the changes of the rotator cuff in frozen shoulder by ultrasonography, which has no rsdiation exposure and is non-invasive. The authors practiced the shoulder ultrasonography on 36 patients with a pain and limitation of motion in shoulder at the Dept. of Orthopedic Surgery, Hangang Sacred Heart Hospital, Hallym University, from March in 1988 to August in 1988. The results are as follows ;1) Ultrasonography is thought to contribute a great deal in detection of the changes of the rotator cuff, especially of the thickness of the rotstor cuff. 2) Among 36 patients, the thickness of the rotator cuff of 35 patients was 6.494+1.008 mm (M+SD) in the affected shoulder and 6.475+1.052 mm(M+SD) in the unaffected shoulder. In only one pstient, the thickness of the rotator cuff was 1.68+0.58 mm(M+SD) in the affected shoulder and 553+1.16mm(M+SD) in the unaffected shoulder. Theres no significant change in the thickness of the rotator cuff measured by ultrasonography in frozen shoulder. 3) Ultrasonography is an excellent diagnostic method in detecting the rupture of the rotator cuff in frozen shoulder.
Bursitis
;
Heart
;
Humans
;
Korea
;
Methods
;
Orthopedics
;
Rotator Cuff
;
Rupture
;
Shoulder
;
Shoulder Joint
;
Ultrasonography
6.Prosthetic Replacement for Severe Proximal Humeral Fractures
Hwa Jae JEONG ; Do Yung KIM ; Joo Ho SHIN ; Sang Ho SONG
The Journal of the Korean Orthopaedic Association 1995;30(5):1354-1360
The authors have reviewed 11 cases of prosthetic replacement for severe proximal humeral fractures which were treated from March 1989 to December 1993, paying particular attention to the range of motion attained after surgery and the factors which influence the limitation of shoulder motion. The results of this study were as follows: l. Among the 11 cases, 10 cases showed sttisfactory pain relief. 2. Active motion of the shoulder averaged 91° of forward flexion, 72.8° of abduction and 35° of external rotation. 3. The humeral offset averaged 30.9mm in normal shoulder and 18.9mm in affected shoulder. 4. In 6 cases which the humeral offset measured over 20mm, active motion averaged 104° of forward flexion and 83° of abduction and 5 cases showed satisfactory results. 5. In 5 cases which the humeral offset measured under 20mm, active motion averaged 104° of forward flexion and 83 of abduction and 5 cases showed unsatisfactory results. 6. Prosthetic replacements were performed within 1 week after injury in 7 cases and among these 5 cases showed satisfactory results. The range of motion after prosthetic replacement for severe proximal humeral fracture was disappointing. We concluded that limited range of motion is mainly due to reduced humeral offset and restoration of humeral offset by appropriate reattachment of greater tuberosity will allow better clinical result.
Range of Motion, Articular
;
Shoulder
;
Shoulder Fractures
7.Comparative Quantitative Study of Surfactant Protein C mRNA by Filter Hybridization and Solution Hybridization in Rats.
Jin Ho KIM ; Jang Won SOHN ; Seok Chul YANG ; Ho Joo YOON ; Dong Ho SHIN ; Sung Soo PARK
Tuberculosis and Respiratory Diseases 2001;51(6):517-529
BACKGROUND: Surfactant protein C(SP-C) is a hydrophobic 5,000 dalton molecule. SP-C has the primary roles in accelerating surface spreading of a surfactant phospholipid. The filter hypbridization and solution hybridization assays are both rapid and sensitive and can be used to measure the RNAs complementary to any cloned DNA sequence. METHODS: The authors measured the SP-C mRNA levels quantitatively using solution hybridization and filter hybridization assays to obtain a standard curve equation to quantify the mRNA of unknown samples comparatively. RESULTS: 1. The minimum level of the specimens by solution hybridization was 3 pg for SP-C mRNA. 2. The standard curve equation of the solution hybridization assay between the counts per minute(Y) and the SP-C mRNA transcript input(X) was Y=6.46 X+244. The correlation coefficient was 0.9. 3. The minimum detection level of specimens by filter hybridization was 0.1 ng for SP-C mRNA. 4. The standard curve equation of the filter hybridization assay between the counts per minute(Y) and SP-C mRNA transcript input(X) is Y=2541.6 X+252.7. The correlation coefficient was 0.99. CONCLUSION: A comparison of CPM/filter in the linear range allowed an accurate and reproducible estimation of the SP-C mRNA copy number. Filter hybridization and solution hybridization assays are both rapid and sensitive and can be used to measure the RNAs complementary to any cloned DNA sequence. It is ideally suited to situations where accurate quantitation of multiple samples is required.
Animals
;
Base Sequence
;
Clone Cells
;
Protein C*
;
Rats*
;
RNA
;
RNA, Messenger*
8.An Unusual Case of Metastatic Adenocarcinoma on the Scrotum with Swelling Originating from Gastric Cancer.
Won Joo KWON ; Min Seok KIM ; Yosub SHIN ; Eun Byul CHO ; Eun Joo PARK ; Kwang Ho KIM ; Kwang Joong KIM
Korean Journal of Dermatology 2017;55(4):264-282
No abstract available.
Adenocarcinoma*
;
Scrotum*
;
Stomach Neoplasms*
9.Median sternotomy for bilateral resection or plication of bullae.
Hee Chul PARK ; Suck Jun KONG ; Ho Seung SHIN ; Bung Joo KIM ; Ki Woo HONG
The Korean Journal of Thoracic and Cardiovascular Surgery 1991;24(2):182-189
No abstract available.
Sternotomy*
10.A STUDY ON THE BOND STRENGTH OF REINFORCED INDIRECT COMPOSITE RESINS TO DENTAL ALLOYS.
Dong Joo YOON ; Sang Wan SHIN ; yu Won SUH ; Ho Nam LIM
The Journal of Korean Academy of Prosthodontics 1999;37(5):620-639
Indirect composite resin are used as an popular effective esthetic material in prosthetic dentistry, often with metallic substructure that provides support for restorations. Recently, new indirect composite resins as a substitute of ceramic have been developed. These resins provide good esthetics, with a wide range of hue and chroma. And the flexural strength of those is in the range of 120-150MPa, which is higher than that of feldspathic ceramic, and similar tot hat of Dicor. Although it has many merits, one of the major clinical problems of composite resins is the bond failure between metal and resin due to insufficient interfacial bond strength. The purpose of this study was to evaluate shear bond strength of the reinforced indirect composite resin to dental alloys. Three different composite resin systems(Artglass . Sculpture , Targis ) as test groups and ceramic(VMK 68 ) as control group were bonded to Ni-Cr-Be alloy(Rexillium III ) and gold alloy(Dave 4). All specimens were stored at 37degrees C distilled water for 24 hours and the half of specimens were thermocycled 2000 times at temperature from 5degrees C to 60degrees C. The shear bond strengths of reinforced indirect composite resins to dental alloys were measured by using the universal testing machine, and modes of debonding were observed by stereoscope and scanning electron microscope. The results were as follows : 1. The shear bond strengths of reinforced indirect composit resins to dental alloys were approximately half those of ceramic to dental alloys(P<0.01). 2. There was no significant difference between the shear bond strength of several reinforced indirect composite resins to metal. 3. Alloy type did not affect on the shear bond strengths of resin to metal, but the shear bond strengths of ceramic to gold alloys were higher than those of ceramic to Ni-Cr alloys(P<0.05). 4. The shear bond strenghts of Artglass and Targis to gold alloys were significantly decreased after thermocycling treatment(P<0.01). 5. Sculpture showed cohesive, adhesive, and mixed failure modes, but Artglass and Targis showed adhesive or mixed failures. And ceramic showed cohesive and mixed failures.
Adhesives
;
Alloys
;
Ceramics
;
Composite Resins*
;
Dental Alloys*
;
Dentistry
;
Esthetics
;
Gold Alloys
;
Sculpture
;
Water